Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 14(5): e0216445, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31050689

RESUMO

Atlantoaxial instability (AAI)/subluxation commonly occurs in small breed dogs. Ventral stabilization techniques using screws and/or pins and a plate or, more commonly, polymethylmethacrylate are considered to provide the most favorable outcome. However, the implantation of screws of sufficient sizes for long-term stability becomes challenging in toy breed dogs (e.g. <2 kg). We herein report the application of 3D printing technology to implant trajectory planning and implant designing for the surgical management of AAI in 18 dogs. The use of our patient-specific drill guide templates resulted in overall mean screw corridor deviations of less than 1 mm in the atlas and axis, which contributed to avoiding iatrogenic injury to the surrounding structures. The patient-specific titanium plate was effective for stabilizing the AA joint and provided clinical benefits to 83.3% of cases (15/18). Implant failure requiring revision surgery occurred in only one case, and the cause appeared to be related to the suboptimal screw-plate interface. Although further modifications are needed, our study demonstrated the potential of 3D printing technology to be effectively applied to spinal stabilization surgeries for small breed dogs, allowing for the accurate placement of screws and minimizing peri- and postoperative complications, particularly at anatomical locations at which screw corridors are narrow and technically demanding.


Assuntos
Articulação Atlantoaxial/cirurgia , Fixadores Internos , Luxações Articulares , Instabilidade Articular , Impressão Tridimensional , Animais , Cães , Feminino , Luxações Articulares/cirurgia , Luxações Articulares/veterinária , Instabilidade Articular/cirurgia , Instabilidade Articular/veterinária , Masculino
2.
J Vet Med Sci ; 75(10): 1379-81, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23719692

RESUMO

A 12-week-old female Wire-haired miniature dachshund presented with non-progressive ataxia and hypermetria. Due to the animal's clinical history and symptoms, cerebellar malformations were suspected. Computed tomography (CT) and magnetic resonance imaging (MRI) detected bilateral ventriculomegaly, dorsal displacement of the cerebellar tentorium, a defect in the cerebellar tentorium and a large fluid-filled cystic structure that occupied the regions where the cerebellar vermis and occipital lobes are normally located. The abovementioned cystic structure and the defect in the cerebellar tentorium were comparable to those seen in humans with Dandy-Walker syndrome. However, the presence of the cystic structure in the occipital lobe region was unique to the present case. During necropsy, the MRI findings were confirmed, but the etiology of the condition was not determined.


Assuntos
Síndrome de Dandy-Walker/veterinária , Doenças do Cão/fisiopatologia , Imageamento por Ressonância Magnética/veterinária , Animais , Síndrome de Dandy-Walker/diagnóstico , Síndrome de Dandy-Walker/fisiopatologia , Doenças do Cão/diagnóstico , Cães , Evolução Fatal , Feminino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA