Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Lab Chip ; 24(3): 492-504, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-38164805

RESUMO

The COVID-19 pandemic increased demands for respiratory disease testing to facilitate treatment and limit transmission, demonstrating in the process that most existing test options were too complex and expensive to perform in point-of-care or home scenarios. Lab-based molecular techniques can detect viral RNA in respiratory illnesses but are expensive and require trained personnel, while affordable antigen-based home tests lack sensitivity for early detection in newly infected or asymptomatic individuals. The few home RNA detection tests deployed were prohibitively expensive. Here, we demonstrate a point-of-care, paper-based rapid analysis device that simultaneously detects multiple viral RNAs; it is demonstrated on two common respiratory viruses (COVID-19 and influenza A) spiked onto a commercial nasal swab. The automated device requires no sample preparation by the user after insertion of the swab, minimizing user operation steps. We incorporated lyophilized amplification reagents immobilized in a porous matrix, a novel thermally actuated valve for multiplexed fluidic control, a printed circuit board that performs on-device lysis and amplification within a cell-phone-sized disposable device. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) products are visualized via fluorescent dyes using a modified cell phone, resulting in detection of as few as 104 viral copies per swab across both pathogens within 30 minutes. This integrated platform could be commercialized in a form that would be inexpensive, portable, and sensitive; it can readily be multiplexed to detect as many as 8 different RNA or DNA sequences, and adapted to any desired RNA or DNA detection assays.


Assuntos
COVID-19 , Ácidos Nucleicos , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Pandemias , Técnicas de Amplificação de Ácido Nucleico , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/genética , RNA Viral/análise , Sensibilidade e Especificidade , Teste para COVID-19
2.
PLoS One ; 18(4): e0284424, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37099532

RESUMO

Recent advances in electronics and microfluidics have enabled several research groups to develop fully integrated, sample-to-result isothermal nucleic acid amplification test (NAAT) platforms for the point of care. However, high component counts and costs have limited translation of these platforms beyond the clinic to low-resource settings-including homes. Many NAATs include complex, multi-component heater electronics based on flex circuits or multiple printed circuit boards (PCBs) to support essential NAAT steps such as lysis, sample deactivation, and nucleic acid amplification. In contrast, current commercial assays for home use, such as those for pregnancy or ovulation that include electronics, typically have just one onboard PCB. This work describes a generalizable strategy to integrate all heaters and the electronics needed to control them onto a single low-cost, USB-powered PCB. We built a multiplexable disposable NAAT ("MD NAAT") platform that applies these principles, integrating small-area heaters that heat small regions to near-boiling (for pathogen lysis and deactivation) and large-area heaters (for amplification) on the same PCB. We show that both classes of heaters have high intra-board and inter-device reproducibility despite only heating a NAAT cartridge from below. We validated the small-area heaters by lysing methicillin-resistant Staphylococcus aureus (MRSA) cells and the large-area heaters by performing two types of isothermal NAATs (isothermal strand displacement amplification (iSDA) and loop-mediated isothermal amplification (LAMP)). These results demonstrate the merit of integrating NAAT heaters and control electronics onto a single printed circuit board and are a step toward translating NAATs to the home.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Ácidos Nucleicos , Staphylococcus aureus Resistente à Meticilina/genética , Reprodutibilidade dos Testes , Técnicas de Amplificação de Ácido Nucleico/métodos , Sistemas Automatizados de Assistência Junto ao Leito
3.
Cureus ; 14(8): e28038, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36120268

RESUMO

Morel-Lavallée lesions (MLL) occur following closed degloving injuries in trauma and appear as subcutaneous fluid collections. These lesions provide a diagnostic dilemma due to their resemblance to other subcutaneous lesions, including post-traumatic or post-procedural hematomas, and malignant entities such as soft tissue sarcomas. Magnetic resonance imaging (MRI) remains the diagnostic test of choice to diagnose MLL. Here we present a single case of MLL in a 40-year-old female who sustained an injury to her left thigh months earlier after falling through a pier as well as a review of literature on the diagnostic findings typically seen in this type of injury.

4.
Sci Rep ; 12(1): 14618, 2022 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-36028745

RESUMO

The simplest point-of-care assays are usually paper and plastic devices that detect proteins or nucleic acids at low cost and minimal user steps, albeit with poor limits of detection. Digital assays improve limits of detection and analyte quantification by splitting a sample across many wells (or droplets), preventing diffusion, and performing analyte amplification and detection in multiple small wells. However, truly digital nucleic acid amplification tests (NAATs) require costly consumable cartridges that are precisely manufactured, aligned, and operated to enable low detection limits. In this study, we demonstrate how to implement near-digital NAATs in low-cost porous media while approaching the low limits of detection of digital assays. The near-digital NAAT was enabled by a paper membrane containing lyophilized amplification reagents that automatically, passively meters and distributes a sample over a wide area. Performing a NAAT in the paper membrane while allowing diffusion captures many of the benefits of digital NAATs if the pad is imaged at a high spatial resolution during amplification. We show that the near-digital NAAT is compatible with a low-cost paper and plastic disposable cartridge coupled to a 2-layer rigid printed circuit board heater (the MD NAAT platform). We also demonstrate compatibility with biplexing and imaging with mobile phones with different camera sensors. We show that the near-digital NAAT increased signal-to-noise ratios by ~ 10×, improved limits of detection from above 103 copies of methicillin-resistant Staphylococcus aureus genomic DNA to between 100 and 316 copies in a biplexed reaction containing 105 copies of co-amplifying internal amplification control DNA, and reduced time-to-result from 45 min of amplification to 15-20 min for the positive samples.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Ácidos Nucleicos , DNA , Técnicas de Amplificação de Ácido Nucleico , Plásticos
5.
Analyst ; 145(21): 6875-6886, 2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-32820749

RESUMO

Nucleic acid amplification test (NAAT)-based point-of-care (POC) devices are rapidly growing for use in low-resource settings. However, key challenges are the ability to store the enzyme-based reagents in dry form in the device and the long-term stability of those reagents at elevated temperatures, especially where ambient temperatures could be as high as 45 °C. Here, we describe a set of excipients including a combination of trehalose, polyethylene glycol and dextran, and a method for using them that allows long-term dry storage of enzyme-based reagents for an isothermal strand displacement amplification (iSDA) reaction in a porous matrix. Various porous materials, including nitrocellulose, cellulose, and glass fiber, were tested. Co-dried reagents for iSDA always included those that amplified the ldh1 gene in Staphylococcus aureus (a polymerase and a nicking enzyme, 4 primers, dNTPs and a buffer). Reagents also either included a capture probe and a streptavidin-Au label required for lateral flow (LF) detection after amplification, or a fluorescent probe used for real-time detection. The reagents showed the best stability in a glass fiber matrix when stored in the presence of 10% trehalose and 2.5% dextran. The reagents were stable for over a year at ∼22 °C as determined by lateral flow detection and gel electrophoresis. The reagents also exhibited excellent stability after 360 h at 45 °C; the assay still detected as few as 10 copies of ldh1 gene target by lateral flow detection, and 50 copies with real-time fluorescence detection. These results demonstrate the potential for incorporation of amplification reagents in dry form in point-of-care devices for use in a wide range of settings.


Assuntos
Ácidos Nucleicos , Sistemas Automatizados de Assistência Junto ao Leito , Indicadores e Reagentes , Técnicas de Amplificação de Ácido Nucleico , Testes Imediatos , Porosidade
6.
Anal Chem ; 92(19): 13066-13072, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-32813501

RESUMO

Nucleic acid amplification tests (NAATs) are common in laboratory and clinical settings because of their low time to result and exquisite sensitivity and specificity. Laboratory NAATs include onboard positive controls to reduce false negatives and specialized hardware to enable real-time fluorescence detection. Recent efforts to translate NAATs into at-home tests sacrifice one or more of the benefits of laboratory NAATs, such as sensitivity, internal amplification controls (IACs), or time to result. In this manuscript, we describe a mobile-phone-based strategy for real-time imaging of biplexed NAATs in paper. The strategy consisted of: (1) using mobile phones with multipass excitation and emission filters on the flash and camera to image the signal from distinct fluorophore-labeled probe types in a biplexed NAAT in a glass fiber membrane; and (2) analyzing the differential fluorescence signal between the red and green color channels of phone images to overcome a strong evaporation-induced optical artifact in heated glass fiber pads due to changes in the refractive index. We demonstrated that differential fluorescence imaging enabled low limits of detection (316 copies of methicillin-resistant Staphylococcus aureus DNA) in our lab's "MD NAAT" platform, even in biplexed isothermal strand displacement amplification reactions containing 100k copies of coamplifying IAC DNA templates. These results suggest that two-fluorophore mobile phone imaging may enable translating the benefits of extant laboratory-based, real-time NAATs to the point of care.


Assuntos
Telefone Celular , DNA Bacteriano/análise , Fluorescência , Staphylococcus aureus Resistente à Meticilina/química , Técnicas de Amplificação de Ácido Nucleico , Imagem Óptica , Tamanho da Partícula , Porosidade , Propriedades de Superfície , Fatores de Tempo
7.
Lab Chip ; 19(5): 885-896, 2019 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-30724293

RESUMO

Influenza is a viral respiratory tract infection responsible for up to 5 million cases of severe infection and nearly 600 000 deaths worldwide each year. While treatments for influenza exist, diagnostics for the virus at the point of care are limited in their sensitivity and ability to differentiate between subtypes. We have developed an integrated two-dimensional paper network (2DPN) for the detection of the influenza virus by the surface glycoprotein, hemagglutinin. The hemagglutinin assay was developed using proteins computationally designed to bind with high affinity to the highly-conserved sialic acid binding site. The integrated 2DPN uses a novel geometry that allows automated introduction of an enzymatic amplification reagent directly to the detection zone. This assay was integrated into a prototype device and demonstrated successful detection of clinically relevant virus concentrations spiked into 70 µL of virus-free pediatric nasal swab samples. Using this novel geometry, we found improved assay performance on the device (compared to a manually-operated dipstick method), with a sensitivity of 4.45 × 102 TCID50 per mL on device.


Assuntos
Glicoproteínas de Hemaglutininação de Vírus da Influenza/análise , Influenza Humana/diagnóstico , Técnicas de Diagnóstico Molecular/instrumentação , Humanos , Papel , Sistemas Automatizados de Assistência Junto ao Leito
8.
Anal Chem ; 90(11): 6967-6974, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29715012

RESUMO

Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low-contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15×. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10× better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.


Assuntos
Telefone Celular , Fluorescência , Imunoensaio , Vírus da Influenza A/isolamento & purificação , Imagem Óptica , Telefone Celular/instrumentação , Desenho de Equipamento , Imunoensaio/instrumentação , Fibras Ópticas , Imagem Óptica/instrumentação , Testes Imediatos
9.
Anal Chem ; 89(22): 12023-12029, 2017 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-29048155

RESUMO

Porous media made of nitrocellulose and glass fiber are common "paper" substrates for lateral flow assays, microfluidic paper analytical devices and other point-of-care diagnostic assays. Such assays commonly use optical labels such as gold nanoparticles, latex beads, or fluorescent nanoparticles to visualize the presence of analytes. Fluorescent labels are commonly used in bioassays to enhance sensitivity, but autoluminescence of the paper substrate worsens signal-to-noise ratios of fluorescence-based assays. To date, there exists no systematic investigation of autoluminescence wavelengths or lifetimes of porous membranes used in lateral flow assays. In response, we quantified the autoluminescence of commonly used porous materials across the visible spectrum via excitation-emission spectroscopy and time-resolved fluorescence spectroscopy, and demonstrate that autoluminescence is solely due to autofluorescence with lifetimes of about 5 ns in the visible spectrum. Counterintuitively, we found that spectroscopy alone does not provide sufficient information to select candidate paper substrates for fluorophore-labeled assays. Therefore, we developed a simple quantitative framework to select a low-fluorescence substrate that minimizes both the overlap of paper and fluorophore emission spectra and the fluorescence intensity on an imaging system of interest (such as a gel imager). Use of this framework was shown to lower the limit of detection of an influenza A nucleoprotein immunoassay by over 50%. The tools developed in this manuscript enable assay developers to screen appropriate, low-fluorescence porous substrates and enhance the sensitivity of membrane-based fluorescence assays.


Assuntos
Fluorescência , Imunoensaio , Vírus da Influenza A/química , Imagem Óptica , Papel , Proteínas Virais/análise , Ouro/química , Nanopartículas Metálicas/química , Porosidade , Propriedades de Superfície
10.
Nat Biotechnol ; 35(7): 667-671, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28604661

RESUMO

Many viral surface glycoproteins and cell surface receptors are homo-oligomers, and thus can potentially be targeted by geometrically matched homo-oligomers that engage all subunits simultaneously to attain high avidity and/or lock subunits together. The adaptive immune system cannot generally employ this strategy since the individual antibody binding sites are not arranged with appropriate geometry to simultaneously engage multiple sites in a single target homo-oligomer. We describe a general strategy for the computational design of homo-oligomeric protein assemblies with binding functionality precisely matched to homo-oligomeric target sites. In the first step, a small protein is designed that binds a single site on the target. In the second step, the designed protein is assembled into a homo-oligomer such that the designed binding sites are aligned with the target sites. We use this approach to design high-avidity trimeric proteins that bind influenza A hemagglutinin (HA) at its conserved receptor binding site. The designed trimers can both capture and detect HA in a paper-based diagnostic format, neutralizes influenza in cell culture, and completely protects mice when given as a single dose 24 h before or after challenge with influenza.


Assuntos
Glicoproteínas de Hemaglutininação de Vírus da Influenza/química , Glicoproteínas de Hemaglutininação de Vírus da Influenza/ultraestrutura , Modelos Químicos , Simulação de Acoplamento Molecular , Engenharia de Proteínas/métodos , Multimerização Proteica , Sítios de Ligação , Ligação Proteica
11.
Anal Chem ; 89(12): 6608-6615, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28499086

RESUMO

Influenza is a ubiquitous and recurring infection that results in approximately 500 000 deaths globally each year. Commercially available rapid diagnostic tests are based upon detection of the influenza nucleoprotein, which are limited in that they are unable to differentiate by species and require an additional viral lysis step. Sample preprocessing can be minimized or eliminated by targeting the intact influenza virus, thereby reducing assay complexity and leveraging the large number of hemagglutinin proteins on the surface of each virus. Here, we report the development of a paper-based influenza assay that targets the hemagglutinin protein; the assay employs a combination of antibodies and novel computationally designed, recombinant affinity proteins as the capture and detection agents. This system leverages the customizability of recombinant protein design to target the conserved receptor-binding pocket of the hemagglutinin protein and to match the trimeric nature of hemagglutinin for improved avidity. Using this assay, we demonstrate the first instance of intact influenza virus detection using a combination of antibody and affinity proteins within a porous network. The recombinant head region binder based assays yield superior analytical sensitivity as compared to the antibody based assay, with lower limits of detection of 3.54 × 107 and 1.34 × 107 CEID50/mL for the mixed and all binder stacks, respectively. Not only does this work describe the development of a novel influenza assay, it also demonstrates the power of recombinant affinity proteins for use in rapid diagnostic assays.


Assuntos
Glicoproteínas de Hemaglutininação de Vírus da Influenza/análise , Orthomyxoviridae/isolamento & purificação , Papel , Anticorpos Monoclonais/imunologia , Ouro/química , Glicoproteínas de Hemaglutininação de Vírus da Influenza/imunologia , Humanos , Nanopartículas Metálicas/química , Modelos Moleculares
12.
Anal Chem ; 89(11): 5776-5783, 2017 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-28445636

RESUMO

A prototype of a self-contained, automated, disposable device for chemically amplified protein-based detection of influenza virus from nasal swab specimens was developed and evaluated in a clinical setting. The device required only simple specimen manipulation without any dedicated instrumentation or specialized training by the operator for interpretation. The device was based on a sandwich immunoassay for influenza virus nucleoprotein; it used an enzyme-labeled antibody and a chromogenic substrate to provide an amplified visible signal, in a two-dimensional paper network format. All reagents were stored within the device. Device performance was assessed at Seattle Children's Hospital; clinical staff collected nasal swab samples from 25 patients and then operated test devices on site to detect influenza A and B in those specimens. The total test time from device initiation to result was approximately 35 min. Device performance for influenza A detection was ∼70% accurate using in-house qRT-PCR influenza A as a gold-standard comparison. The ratio of valid to total completed device runs yielded a success rate of 92%, and the negative predictive value for both the influenza A and B assay was 81%. The ability to diagnose respiratory infections rapidly and close to the patient was well received by hospital staff, inspiring further optimization of device function.


Assuntos
Influenza Humana/diagnóstico , Manejo de Espécimes/métodos , Proteínas Virais/análise , Testes Diagnósticos de Rotina/instrumentação , Humanos , Imunoensaio/instrumentação , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Nucleoproteínas/análise , Fatores de Tempo
13.
Methods Enzymol ; 589: 383-411, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28336071

RESUMO

The design of appropriate diagnostic assays for the point of care requires development of suitable biosensors, detection methods, and diagnostic platforms for sensitive, quantitative detection of biological analytes. Protein targets in particular are especially challenging to detect quantitatively and sensitively due to the lack of amplification strategies akin to nucleic acid amplification. However, recent advances in transducer and biosensor design, new detection labels, and paper-based microfluidics may realize the goal of sensitive, fast, portable, and low-cost protein detection. In this review, we discuss the biochemistry, optics, and engineering advances that may be leveraged to design such a sensitive protein diagnostic assay. The binding kinetics, mechanisms of binding in porous networks, and potential transducers are explained in detail. We discuss the relative merits of various optical detection strategies, potential detection labels, optical readout approaches, and image-processing techniques that are amenable to point-of-care use. To conclude, we present a systematic analysis of potential approaches to enhance the sensitivity of paper-based assays. The assay development framework presented here provides bioassay developers a strategy to methodically enhance the sensitivity and point-of-care suitability of protein diagnostics.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Analíticas Microfluídicas/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Proteínas/análise , Animais , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Papel
14.
Lab Chip ; 16(19): 3777-87, 2016 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-27549897

RESUMO

The prototype demonstrated here is the first fully integrated sample-to-result diagnostic platform for performing nucleic acid amplification tests that requires no permanent instrument or manual sample processing. The multiplexable autonomous disposable nucleic acid amplification test (MAD NAAT) is based on two-dimensional paper networks, which enable sensitive chemical detection normally reserved for laboratories to be carried out anywhere by untrained users. All reagents are stored dry in the disposable test device and are rehydrated by stored buffer. The paper network is physically multiplexed to allow independent isothermal amplification of multiple targets; each amplification reaction is also chemically multiplexed with an internal amplification control. The total test time is less than one hour. The MAD NAAT prototype was used to characterize a set of human nasal swab specimens pre-screened for methicillin-resistant Staphylococcus aureus (MRSA) bacteria. With qPCR as the quantitative reference method, the lowest input copy number in the range where the MAD NAAT prototype consistently detected MRSA in these specimens was ∼5 × 10(3) genomic copies (∼600 genomic copies per biplexed amplification reaction).


Assuntos
Técnicas de Amplificação de Ácido Nucleico/métodos , Desenho de Equipamento , Humanos , Staphylococcus aureus Resistente à Meticilina/genética , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Nariz/microbiologia , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Papel , Fatores de Tempo
15.
J Microbiol Methods ; 128: 80-87, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27424294

RESUMO

Nucleic acid sample preparation has been an especially challenging barrier to point-of-care nucleic acid amplification tests in low-resource settings. Here we provide a head-to-head comparison of methods for lysis of, and nucleic acid release from, several pathogenic bacteria and viruses-methods that are adaptable to point-of-care usage in low-resource settings. Digestion with achromopeptidase, a mixture of proteases and peptidoglycan-specific hydrolases, followed by thermal deactivation in a boiling water bath, effectively released amplifiable nucleic acid from Staphylococcus aureus, Bordetella pertussis, respiratory syncytial virus, and influenza virus. Achromopeptidase was functional after dehydration and reconstitution, even after eleven months of dry storage without refrigeration. Mechanical lysis methods proved to be effective against a hard-to-lyse Mycobacterium species, and a miniature bead-mill, the AudioLyse, is shown to be capable of releasing amplifiable DNA and RNA from this species. We conclude that point-of-care-compatible sample preparation methods for nucleic acid tests need not introduce amplification inhibitors, and can provide amplification-ready lysates from a wide range of bacterial and viral pathogens.


Assuntos
DNA Bacteriano/isolamento & purificação , DNA Viral/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Bordetella pertussis/isolamento & purificação , Mycobacterium/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico , Orthomyxoviridae/isolamento & purificação , Vírus Sinciciais Respiratórios/isolamento & purificação , Staphylococcus aureus/isolamento & purificação
16.
Anal Bioanal Chem ; 408(5): 1335-46, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26427504

RESUMO

To enable enhanced paper-based diagnostics with improved detection capabilities, new methods are needed to immobilize affinity reagents to porous substrates, especially for capture molecules other than IgG. To this end, we have developed and characterized three novel methods for immobilizing protein-based affinity reagents to nitrocellulose membranes. We have demonstrated these methods using recombinant affinity proteins for the influenza surface protein hemagglutinin, leveraging the customizability of these recombinant "flu binders" for the design of features for immobilization. The three approaches shown are: (1) covalent attachment of thiolated affinity protein to an epoxide-functionalized nitrocellulose membrane, (2) attachment of biotinylated affinity protein through a nitrocellulose-binding streptavidin anchor protein, and (3) fusion of affinity protein to a novel nitrocellulose-binding anchor protein for direct coupling and immobilization. We also characterized the use of direct adsorption for the flu binders, as a point of comparison and motivation for these novel methods. Finally, we demonstrated that these novel methods can provide improved performance to an influenza hemagglutinin assay, compared to a traditional antibody-based capture system. Taken together, this work advances the toolkit available for the development of next-generation paper-based diagnostics.


Assuntos
Proteínas de Transporte/metabolismo , Cromatografia de Afinidade/métodos , Colódio/metabolismo , Proteínas Imobilizadas/metabolismo , Papel , Proteínas Recombinantes/metabolismo , Estreptavidina/metabolismo , Anticorpos/química , Anticorpos/metabolismo , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Proteínas de Transporte/química , Colódio/química , Proteínas Imobilizadas/química , Proteínas Recombinantes/química , Estreptavidina/química
17.
Analyst ; 140(22): 7540-9, 2015 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-26393240

RESUMO

We present a method of rapid isothermal amplification of DNA without initial heat denaturation of the template, and methods and probes for (a) real-time fluorescence detection and (b) lateral flow detection of amplicons. Isothermal strand displacement amplification (iSDA) can achieve >10(9)-fold amplification of the target sequence in <20 minutes at 49 °C, which makes it one of the fastest existing isothermal DNA amplification methods. iSDA initiates at sites where DNA base pairs spontaneously open or transiently convert into Hoogsteen pairs, i.e. "breathe", and proceeds to exponential amplification by repeated nicking, extension, and displacement of single strands. We demonstrate successful iSDA amplification and lateral flow detection of 10 copies of a Staphylococcus aureus gene, NO.-inducible l-lactate dehydrogenase (ldh1) (Richardson, Libby, and Fang, Science, 2008, 319, 1672-1676), in a clean sample and 50 copies in the presence of high concentrations of genomic DNA and mucins in <30 minutes. We also present a simple kinetic model of iSDA that incorporates competition between target and primer-dimer amplification. This is the first model that quantitates the effects of primer-dimer products in isothermal amplification reactions. Finally, we demonstrate the multiplexing capability of iSDA by the simultaneous amplification of the target gene and an engineered internal control sequence. The speed, sensitivity, and specificity of iSDA make it a powerful method for point-of-care molecular diagnosis.


Assuntos
Proteínas de Bactérias/genética , DNA Bacteriano/genética , L-Lactato Desidrogenase/genética , Staphylococcus aureus Resistente à Meticilina/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Infecções Estafilocócicas/diagnóstico , Proteínas de Bactérias/isolamento & purificação , DNA Bacteriano/isolamento & purificação , Humanos , Isoenzimas/genética , Isoenzimas/isolamento & purificação , L-Lactato Desidrogenase/isolamento & purificação , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/economia , Sistemas Automatizados de Assistência Junto ao Leito/economia , Infecções Estafilocócicas/microbiologia , Fatores de Tempo
18.
Artigo em Inglês | MEDLINE | ID: mdl-26236229

RESUMO

Deep brain stimulation (DBS) in the pedunculopontine tegmental nucleus (PPTg) has been proposed to alleviate medically intractable gait difficulties associated with Parkinson's disease. Clinical trials have shown somewhat variable outcomes, stemming in part from surgical targeting variability, modulating fiber pathways implicated in side effects, and a general lack of mechanistic understanding of DBS in this brain region. Subject-specific computational models of DBS are a promising tool to investigate the underlying therapy and side effects. In this study, a parkinsonian rhesus macaque was implanted unilaterally with an 8-contact DBS lead in the PPTg region. Fiber tracts adjacent to PPTg, including the oculomotor nerve, central tegmental tract, and superior cerebellar peduncle, were reconstructed from a combination of pre-implant 7T MRI, post-implant CT, and post-mortem histology. These structures were populated with axon models and coupled with a finite element model simulating the voltage distribution in the surrounding neural tissue during stimulation. This study introduces two empirical approaches to evaluate model parameters. First, incremental monopolar cathodic stimulation (20 Hz, 90 µs pulse width) was evaluated for each electrode, during which a right eyelid flutter was observed at the proximal four contacts (-1.0 to -1.4 mA). These current amplitudes followed closely with model predicted activation of the oculomotor nerve when assuming an anisotropic conduction medium. Second, PET imaging was collected OFF-DBS and twice during DBS (two different contacts), which supported the model predicted activation of the central tegmental tract and superior cerebellar peduncle. Together, subject-specific models provide a framework to more precisely predict pathways modulated by DBS.

20.
Lab Chip ; 15(6): 1432-44, 2015 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-25606810

RESUMO

Failure to utilize valving and automation techniques has restricted the complexity of fluidic operations that can be performed in paper microfluidic devices. We developed a toolkit of paper microfluidic valves and methods for automatic valve actuation using movable paper strips and fluid-triggered expanding elements. To the best of our knowledge, this is the first functional demonstration of this valving strategy in paper microfluidics. After introduction of fluids on devices, valves can actuate automatically after a) a certain period of time, or b) the passage of a certain volume of fluid. Timing of valve actuation can be tuned with greater than 8.5% accuracy by changing lengths of timing wicks, and we present timed on-valves, off-valves, and diversion (channel-switching) valves. The actuators require ~30 µl fluid to actuate and the time required to switch from one state to another ranges from ~5 s for short to ~50 s for longer wicks. For volume-metered actuation, the size of a metering pad can be adjusted to tune actuation volume, and we present two methods - both methods can achieve greater than 9% accuracy. Finally, we demonstrate the use of these valves in a device that conducts a multi-step assay for the detection of the malaria protein PfHRP2. Although slightly more complex than devices that do not have moving parts, this valving and automation toolkit considerably expands the capabilities of paper microfluidic devices. Components of this toolkit can be used to conduct arbitrarily complex, multi-step fluidic operations on paper-based devices, as demonstrated in the malaria assay device.


Assuntos
Dispositivos Lab-On-A-Chip , Papel , Antígenos de Protozoários/análise , Automação , Concentração de Íons de Hidrogênio , Proteínas de Protozoários/análise , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA