Int J Implant Dent ; 10(1): 15, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509336

RESUMO

PURPOSE: This study aimed to clarify the effects of surface modification of titanium (Ti) implants by low-temperature atmospheric pressure plasma treatment on wound healing and cell attachment for biological sealing in peri-implant soft tissue. METHODS: Hydrophilization to a Ti disk using a handheld low-temperature atmospheric pressure plasma device was evaluated by a contact angle test and compared with an untreated group. In in vivo experiments, plasma-treated pure Ti implants using a handheld plasma device (experimental group: PL) and untreated implants (control group: Cont) were placed into the rat upper molar socket, and samples were harvested at 3, 7 and 14 days after surgery. Histological evaluation was performed to assess biological sealing, collagen- and cell adhesion-related gene expression by reverse transcription quantitative polymerase chain reaction, collagen fiber detection by Picrosirius Red staining, and immunohistochemistry for integrins. RESULTS: In in vivo experiments, increased width of the peri-implant connective tissue (PICT) and suppression of epithelial down growth was observed in PL compared with Cont. In addition, high gene expression of types I and XII collagen at 7 days and acceleration of collagen maturation was recognized in PL. Strong immunoreaction of integrin α2, α5, and ß1 was observed at the implant contact area of PICT in PL. CONCLUSIONS: The handheld low-temperature atmospheric pressure plasma device provided hydrophilicity on the Ti surface and maintained the width of the contact area of PICT to the implant surface as a result of accelerated collagen maturation and fibroblast adhesion, compared to no plasma application.


Assuntos
Implantes Dentários , Ratos , Animais , Titânio , Temperatura , Propriedades de Superfície , Tecido Conjuntivo/patologia , Colágeno , Cicatrização
2.
Dent Mater J ; 42(5): 633-640, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37423721

RESUMO

Titanium is a biocompatible material commonly used for dental treatments. However, the detailed mechanism underlying the weak biological activity of titanium has not been elucidated. We investigated both the inflammatory responses and T cell activation induced by solid titanium in the gingiva in mice. Both titanium and nickel wire implantation promoted neutrophil infiltration into the gingiva on day 2. Nickel, but not titanium, wire implantation enhanced proinflammatory cytokine expression and dendritic cell activity in gingival tissue by day 2. Nickel wire implantation enhanced the activity of T cells in draining lymph nodes on day 5. Moreover, T cell and neutrophil infiltration and elevated proinflammatory cytokine expression in the gingival tissue were still observed on day 5. However, no such augmented biological responses were observed after titanium wire implantation. These findings suggest that, unlike nickel, solid titanium does not induce sufficient inflammatory responses leading to T cell activation in gingival tissue.


Assuntos
Níquel , Titânio , Camundongos , Animais , Gengiva , Materiais Biocompatíveis , Teste de Materiais
3.
Sci Rep ; 13(1): 3442, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859576

RESUMO

The lineage of periodontal ligament (PDL) stem cells contributes to alveolar bone (AB) and cementum formation, which are essential for tooth-jawbone attachment. Leptin receptor (LepR), a skeletal stem cell marker, is expressed in PDL; however, the stem cell capacity of LepR+ PDL cells remains unclear. We used a Cre/LoxP-based approach and detected LepR-cre-labeled cells in the perivascular around the root apex; their number increased with age. In the juvenile stage, LepR+ PDL cells differentiated into AB-embedded osteocytes rather than cementocytes, but their contribution to both increased with age. The frequency of LepR+ PDL cell-derived lineages in hard tissue was < 20% per total cells at 1-year-old. Similarly, LepR+ PDL cells differentiated into osteocytes following tooth extraction, but their frequency was < 9%. Additionally, both LepR+ and LepR- PDL cells demonstrated spheroid-forming capacity, which is an indicator of self-renewal. These results indicate that both LepR+ and LepR- PDL populations contributed to hard tissue formation. LepR- PDL cells increased the expression of LepR during spheroid formation, suggesting that the LepR- PDL cells may hierarchically sit upstream of LepR+ PDL cells. Collectively, the origin of hard tissue-forming cells in the PDL is heterogeneous, some of which express LepR.


Assuntos
Ligamento Periodontal , Receptores para Leptina , Células-Tronco , Diferenciação Celular , Células do Tecido Conjuntivo
4.
Odontology ; 111(3): 630-639, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36460825

RESUMO

The purpose of this study was to investigate the process and derivation of the distribution of the sensory nerves that appear in the extraction socket and surrounding alveolar bone following tooth extraction. The right mandibular first molar of rats and periodontal ligament were extracted as a single mass, and the mandible was harvested after days 1, 3, 5, and 7 after extraction. Serial sections of 7 µm thickness were prepared for the proximal root (Section A), buccolingual root (Section B), and centrifugal root (Section C) of the first molar. H-E staining and immunohistochemical staining with anti-S100 antibody and anti-NF-L antibody were carried out. The presence of nerve fiber bundles in the blood clot was already evident on post-extraction day 3, and on post-extraction day 7. On day 3, the number of axons in Sections B and C had greatly decreased, indicating that, after extraction, the connection between peripheral nerve tissue and the trigeminal ganglion was temporarily markedly reduced in the region of the alveolar branch. Although the myelin sheaths were regenerating on day 5, the majority of the axons of the alveolar branches extending from the inferior alveolar nerve were seen to be extremely thin and scattered, despite their further regeneration. The above results suggest that the newly myelinated nerves are actually derived from the bone marrow to the extraction socket, so few nerves, rather than being derived from the alveolar branches that had innervated the extracted tooth.


Assuntos
Bainha de Mielina , Ligamento Periodontal , Animais , Ratos , Axônios , Nervo Mandibular , Dente Molar
5.
J Prosthet Dent ; 129(6): 878-886, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34688477

RESUMO

STATEMENT OF PROBLEM: The buccal bone in an edentulous maxilla loses thickness over time because of physiological changes. However, the dimensional changes of the buccal bone in an edentulous maxilla with an implant-supported fixed dental prosthesis are unknown. PURPOSE: The purpose of this retrospective clinical study was to evaluate cone beam computed tomography (CBCT) images of the dimensional changes of the buccal bone in edentulous maxillae with complete arch telescopic-retained implant-supported fixed dental prostheses (CTI-FDPs) after 6 years by using a professional retrieval system. MATERIAL AND METHODS: This study included 17 participants with edentulous maxillae who had been provided with CTI-FDP with 121 taper joint implants. A three-dimensional radiographic analysis by using CBCT was performed at implant insertion (0 years) and after 6 years. Vertical and horizontal bone measurement values were evaluated. During horizontal bone thickness measurement, 4 different levels, 0, 2, 4, and 6 mm apical to the implant shoulder, were evaluated as bone value (BV)0mm, BV2mm, BV4mm, and BV6mm, respectively. The BVs were compared with the Wilcoxon signed-rank test and Kruskal-Wallis test (α=.05). In addition, the Spearman rank correlation coefficient was used to identify 0yBV factors that influence the 6yBVs. A nonlinear regression analysis was used to clarify the slopes of 0yBVs and 6yBV0mm. RESULTS: Significant decreases in vertical and horizontal BVs were found between 0 years and 6 years (P<.05). However, no significant difference was observed in bone loss at 6 years at any of the vertical and horizontal measurement points (P≥.05). When 0yBVs related to 6yBV0mm were analyzed, 0yBV0mm and 0yBV2mm showed strong correlations with 6yBV0mm (|r|≥.7). In the regression analysis, a 0yBV0mm of 0.58 mm and 0yBV2mm of 0.78 mm could be critical factors associated with a 6yBV0mm of 0 mm. A 6yBV0mm of 0yBV0mm more than 0.58 mm was significantly higher than a 6yBV0mm of 0yBV0mm less than 0.58 mm (P<.001). Moreover, a 6yBV0mm of 0yBV2mm more than 0.78 mm was significantly higher than a 6yBV0mm of 0yBV2mm less than 0.78 mm (P<.001). CONCLUSIONS: The buccal bone in an edentulous maxilla with fixed implant-supported prostheses lost significant vertical and horizontal bone thicknesses after 6 years. At implant insertion, both a 0.58-mm buccal bone on the platform and a 0.78-mm buccal bone at 2 mm apical to the implant shoulder are necessary for longer term maintenance of bone on the platform of implants specifically supporting CTI-FDPs.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Estudos Retrospectivos , Planejamento de Prótese Dentária , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Seguimentos , Prótese Dentária Fixada por Implante , Implantação Dentária Endóssea/métodos
6.
Int J Implant Dent ; 8(1): 17, 2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35411479

RESUMO

PURPOSE: Many points concerning the structure of osseointegration and the surrounding jaw bone remain unclear, and its optimal histological form has yet to be identified. The aim of this study was to clarify the structural characteristics of peri-implant jaw bone on the micro- and nano-scales by quantitatively evaluating bone quality. METHODS: Five samples of human mandibular bone containing dental implants and one dentate sample that had been in place for some years while the donors were still alive were collected. Bulk staining was performed, and 100-µm-thick polished specimens were prepared. The osteon distributions in peri-implant bone and mandibular cortical bone were measured, after which alignment analysis of biological apatite (BAp) crystallites and anisotropy analysis of collagen fiber orientation using second-harmonic generation imaging were carried out. RESULTS: Osteons in the vicinity of the implant body ran parallel to it. In the cortical bone at the base of the mandible, however, most osteons were oriented mesiodistally. The preferential alignment of BAp crystallites was generally consistent with osteon orientation. The orientation of collagen fibers in peri-implant jaw bone resembled the concentric rings seen in normal cortical bone, but there were also fibers that ran orthogonally across these concentric fibers. CONCLUSIONS: These results suggest that the mechanical strain imposed by implants causes the growth of cortical bone-like bone in areas that would normally consist of cancellous bone around the implants, and that its structural characteristics are optimized for the load environment of the peri-implant jaw bone.


Assuntos
Implantes Dentários , Apatitas , Cadáver , Colágeno/química , Humanos , Mandíbula/diagnóstico por imagem , Osseointegração
7.
Bull Tokyo Dent Coll ; 63(1): 23-30, 2022 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-35173084

RESUMO

This report describes long-term implant treatment in a patient with chronic periodontitis. The patient was a 59-year-old man who attended our facility requesting a dental implant. An initial examination revealed generalized gingival inflammation and subgingival calculus. Clinical examination revealed 55.3% of sites with a probing depth (PD) of >4 mm and 41.3% of sites with bleeding on probing. Radiographic examination revealed vertical bone resorption in #23, #33, #33, #35, and #47. Initial periodontal therapy consisting of plaque control, scaling and root planing, and tooth extraction was subsequently performed based on a clinical diagnosis of severe chronic periodontitis. Open flap debridement was performed for teeth with a PD >5 mm (#21, #22, #23, 333, #34, #35 and #47). After confirming the stability of the periodontal tissue, 3 implants were first placed in the maxilla (#25, #26, and #27). Final prostheses comprising a screw retaining-type implant superstructure were then placed (#25, #26, and 327). Following reevaluation, the patient was placed on supportive periodontal therapy. At 15 years after the first visit, the periodontal and implant conditions have remained stable. These results indicate that periodontal treatment before implantation and subsequent maintenance yield a clinically favorable and long-lasting outcome.


Assuntos
Perda do Osso Alveolar , Periodontite Crônica , Implantes Dentários , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/cirurgia , Periodontite Crônica/cirurgia , Raspagem Dentária , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Aplainamento Radicular , Resultado do Tratamento
8.
J Prosthodont ; 31(3): 190-195, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34859538

RESUMO

Owing to the satisfactory esthetic and functional outcomes of implant surgery for the anterior teeth, some dentists consider it the gold standard treatment. However, the risk of developing peri-implantitis is positively associated with the long-term use of the implant. This necessitates the development of an implant design that reduces the risk of peri-implantitis, especially considering the long-term use of implants in young patients. This case report describes a new approach for an implant surgery using a two-stage implant in a 28-year-old woman. Her clinical course was satisfactory during the 4-year postoperative follow-up period; no inflammation was noted in the surrounding tissues. The two-stage implants allow for the removal of an implant body from an infected area and its replacement with a new abutment if peri-implantitis develops in the future.


Assuntos
Implantes Dentários , Peri-Implantite , Dente , Adulto , Implantes Dentários/efeitos adversos , Estética Dentária , Feminino , Humanos , Inflamação , Peri-Implantite/etiologia , Peri-Implantite/terapia
9.
J Biomed Mater Res A ; 110(4): 899-908, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34850541

RESUMO

Many of genes specifically expressed in peri-implant soft tissue (PIST) selected by microarray analysis are involved in the inflammatory response. This study investigated the gene expression and localization of PIST-specific inflammatory markers in PIST during wound healing. Pure titanium implants were implanted into the rat upper mandibular socket to create PIST. Samples were harvested from PIST as an experimental group, and tooth extracted area of oral mucosa tissue (OMT) and healthy periodontal tissue (PT) as control groups. The gene expressions of four standard inflammatory markers and nine PIST-specific inflammatory markers including chemokine (C-X-C motif) ligand 2 (CXCL2) during wound healing were examined. Immunoreactions of CXCL2 and immune cells in PIST and control tissues were compared. During wound healing, gene expression of PIST-specific inflammatory markers was higher in PIST than in OMT (p < .05), but there were no significant differences in the expression of standard inflammatory markers. The molecule CXCL2 was expressed locally at the implant-connective tissue interface, and localization of immune cells closely matched the CXCL2 expression pattern. In PIST, seven of PIST-specific inflammatory markers were expressed specifically and strongly during wound healing and their expression was maintained until the end of healing. Furthermore, CXCL2 expression was due to the creation of the implant-connective tissue interface, and it established a unique defense mechanism in PIST that was not apparent in OMT or PT.


Assuntos
Implantes Dentários , Titânio , Animais , Quimiocina CXCL2 , Tecido Conjuntivo , Mucosa Bucal , Periodonto , Ratos , Titânio/farmacologia , Cicatrização
10.
Int J Implant Dent ; 7(1): 105, 2021 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-34613503

RESUMO

OBJECTIVE: The mechanisms underlying the onset and progression of peri-implantitis are similar to those of periodontitis, and the causative bacteria are believed to similar. Previous studies support an association between peri-implantitis and periodontal pathogen. Thus, we investigated the bacterial flora of peri-implantitis patients in comparison to those of healthy implant and periodontitis patients. MATERIALS AND METHODS: In total, 70 patients visiting Tokyo Dental College Chiba Hospital were divided into four groups: healthy, periodontitis, healthy implant, and peri-implantitis. For each group, the following five periodontal pathogens were detected using real-time polymerase chain reaction: Porphyromonas gingivalis, Aggregatibacter actinomycetemcomitans, Tannerella forsythia, Treponema denticola, and Prevotella intermedia. RESULTS: The average copy number of total bacteria was significantly higher in the periodontitis group than in the other groups. P. gingivalis was detected in the periodontitis and peri-implantitis groups at levels as high as 18.92% and 12.29%, respectively, and P. intermedia was found in the peri-implantitis group at a rate of 2.06%. Nevertheless, periodontal pathogens were generally detected at lower levels in the peri-implantitis group than in the periodontitis group. CONCLUSION: We found lower bacterial counts in the peri-implantitis group relative to the periodontitis group. Our results suggest that the peri-implant tissue is less resistant to bacteria, so even a small number of bacteria can be a risk factor for peri-implantitis and the causative agent of peri-implantitis can be bacteria other than periodontal pathogen.


Assuntos
Peri-Implantite , Aggregatibacter actinomycetemcomitans , Humanos , Prevotella intermedia , Reação em Cadeia da Polimerase em Tempo Real , Treponema denticola
11.
Int J Implant Dent ; 7(1): 89, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34467429

RESUMO

BACKGROUND: There are many unclear points regarding local structural characteristics of the bone surrounding the implant reflecting the mechanical environment. PURPOSE: The purpose of this study is to quantitatively evaluate bone quality surrounding implants placed into the femurs of mice in an unloading model, and to determine the influence of the mechanical environment on bone quality. METHODS: Twenty 12-week-old male C57BL6/NcL mice (n = 5/group) were used as experimental animals. The mice were divided into two groups: the experimental group (n = 10) which were reared by tail suspension, and the control group (n = 10) which were reared normally. An implant was placed into the femur of a tail-suspended mouse, and after the healing period, they were sacrificed and the femur was removed. After micro-CT imaging, Villanueva osteochrome bone stain was performed. It was embedded in unsaturated polyester resin. The polymerized block was sliced passing through the center of the implant body. Next, 100-µm-thick polished specimens were prepared with water-resistant abrasive paper. In addition to histological observation, morphometric evaluation of cancellous bone was performed, and the anisotropy of collagen fibers and biological apatite (BAp) crystals was analyzed. RESULTS: As a result, the femoral cortical bone thickness and new peri-implant bone mass showed low values in the tail suspension group. The uniaxial preferential orientation of BAp c-axis in the femoral long axis direction in the non-implant groups, but biaxial preferential orientation of BAp c-axis along the long axis of implant and femoral long axis direction were confirmed in new bone reconstructed by implant placement. Collagen fiber running anisotropy and orientation of BAp c-axis in the bone surrounding the implant were not significantly different due to tail suspension. CONCLUSIONS: From the above results, it was clarified that bone formation occurs surrounding the implant even under extremely low load conditions, and bone microstructure and bone quality adapted to the new mechanical environment are acquired.


Assuntos
Implantes Dentários , Animais , Densidade Óssea , Osso e Ossos , Fêmur/diagnóstico por imagem , Masculino , Camundongos , Cauda
12.
Bull Tokyo Dent Coll ; 62(3): 193-200, 2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34393146

RESUMO

One serious complication in implant surgery is displacement of the implant body into the surrounding tissue. This occurs only rarely in the mandible, however. This report describes a case of an implant body displacing into the medullary cavity of the mandible and discusses this in reference to the literature. The patient was a 72-year-old woman who was referred to our department at Tokyo Dental College Chiba Hospital (now Chiba Dental Center) by her regular dentist after an implant inserted in the left mandible in 2010 showed loosening in October 2016. Panoramic X-rays obtained at the initial examination revealed that 2 implants had been inserted into the left mandible, one on top of the other. Removal of both was recommended to prevent infection at the implant site and any potential effects on the alveolar nerve. In the absence of subjective symptoms other than implant loosening, however, the patient did not consent to this proposal. Therefore, only the broken abutment was removed. The patient was instructed to contact us immediately should infection or any other symptoms appear once the mucosa had healed, and the dental clinic that had referred her to us was requested to make her a set of dentures. To our knowledge, only 11 reports have been published to date describing displacement of an implant body into the mandible, and these address a total of just 20 cases. The possibility that an implant body in the mandible may become displaced must be kept in mind during treatment.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Idoso , Implantação Dentária Endóssea/efeitos adversos , Implantes Dentários/efeitos adversos , Prótese Dentária Fixada por Implante , Feminino , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Tóquio
13.
PLoS One ; 16(4): e0249526, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33831057

RESUMO

Extracellular vesicles (EVs) in body fluids constitute heterogenous populations, which mirror their diverse parental cells as well as distinct EV-generation pathways. Various methodologies have been proposed to differentiate EVs in order to deepen the current understanding of EV biology. Equilibrium density-gradient centrifugation has often been used to separate EVs based on their buoyant densities; however, the standard conditions used for the method do not necessarily allow all EVs to move to their equilibrium density positions, which complicates the categorization of EVs. Here, by prolonging ultracentrifugation time to 96 h and fractionating EVs both by floating up or spinning down directions, we allowed 111 EV-associated protein markers from the whole saliva of three healthy volunteers to attain equilibrium. Interestingly, the determined buoyant densities of the markers drifted in a specimen-specific manner, and drift patterns differentiated EVs into at least two subclasses. One class carried classical exosomal markers, such as CD63 and CD81, and the other was characterized by the molecules involved in membrane remodeling or vesicle trafficking. Distinct patterns of density drift may represent the differences in generation pathways of EVs.


Assuntos
Biomarcadores/metabolismo , Centrifugação com Gradiente de Concentração/métodos , Vesículas Extracelulares/metabolismo , Saliva/metabolismo , Adulto , Humanos
14.
Clin Oral Implants Res ; 32(7): 818-827, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33754378

RESUMO

OBJECTIVES: This study compared full-arch screw-retained implant-supported fixed dental prostheses (FSI-FDPs) and full-arch telescopic-retained implant-supported fixed dental prostheses with a professional retrieval system (FTI-FDPs) on marginal bone loss (MBL), the risk indicators and peri-implantitis rate after 7-13 years. MATERIAL AND METHODS: Sixty five edentulous patients were treated with 86 prostheses and 592 implants. The FSI-FDP group comprised 26 patients (32 prostheses, 202 implants), and the FTI-FDP group comprised 39 patients (54 prostheses, 390 implants). MBL and the risk indicators of MBL ≥1 mm were assessed. Peri-implantitis rates at 13 years were also calculated. RESULTS: Full-arch screw-retained implant-supported fixed dental prostheses and FTI-FDP implants exhibited comparable mean MBLs of 0.60 ± 0.51 and 0.41 ± 1.03 mm, respectively. MBL ≥1 mm was noted for 25% of FSI-FDP implants and 6.9% of FTI-FDP implants. Superstructure-abutment connection (screw retention:FSI-FDPs >telescopic retention:FTI-FDPs) and implant-abutment connection (External butt joint, Internal butt joint >Morse taper joint) were associated with MBL ≥1 mm. Peri-implantitis rates at the implant level were 3.99% (95%CI = 3.93-20.5) in FSI-FDP group and 3.85% (95%CI = 3.85-34.3) in FTI-FDP group with no significance. CONCLUSIONS: It was concluded that FSI-FDP and FTI-FDP implants exhibited comparable MBL; however, the risk of MBL ≥1 mm in FTI-FDPs was lower than in FSI-FDPs. Besides, implant-abutment connection was the risk indicator of MBL ≥1 mm. In peri-implantitis rate, FSI-FDPs and FTI-FDPs behave similarly.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Parafusos Ósseos , Estudos de Casos e Controles , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante/efeitos adversos , Falha de Restauração Dentária , Humanos , Estudos Retrospectivos
15.
Dent Mater J ; 40(4): 885-893, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33692224

RESUMO

The objective of this study was to clarify the fatigue behavior of hollow yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) specimens assuming its use for two-piece implants. The fatigue properties of a solid specimen (which simulated a one-piece implant) and 3 types of hollow specimens (which simulated two-piece implants) were evaluated. Specimens were either solid with a diameter of 4.0 mm (S) or hollow with an inner diameter of 3.0 mm and outer diameters of 4.0 mm (H0.5), 4.5 mm (H0.75), or 5.0 mm (H1.0). For each group, 25 specimens were prepared followed by blast and acid etch treatment. Static fracture and cyclic fatigue tests were conducted by modifying the methods provided in ISO6872. Fracture modes were determined by observing the surfaces under a scanning electron microscope. As a result, the cyclic fatigue load of S and H1.0 were similar, and hollow specimens with outer diameters greater than 0.75 mm displayed the ability to withstand molar occlusal forces.


Assuntos
Ítrio , Zircônio , Análise do Estresse Dentário , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície
16.
Sci Rep ; 11(1): 4498, 2021 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-33627733

RESUMO

Streptococci are associated with dental plaque formation as the early-colonizing bacteria that adhere to titanium (CpTi) and zirconia (TZP) implant abutment surfaces. Effective prevention of peri-implantitis may be possible by removing streptococci as target. This study aimed to evaluate the effects of 2% NaF on the prevention of streptococcal adhesion to CpTi and TZP. After immersion in 2% NaF for 90 min, surface characterization of mirror-polished CpTi and TZP disks were assesed using XPS, EPMA, and SEM. S. sanguinis, S. gordonii, and S. oralis were used as the streptococcal bacterial strains. After 24 h culture, bacterial adhesion was evaluated using an ATP-bioluminescent assay and SEM. In XPS, EPMA, and SEM analyses, fluoride was detected on the CpTi and TZP surfaces after 2% NaF immersion with no signs of localization, and no corrosion on the CpTi disks. Based on the adhesion assay, the adherences of S. sanguinis, S. gordonii, and S. oralis were significantly lower with NaF than without NaF in CpTi (p = 0.005, 0.001, and 0.001, respectively) and TZP (p = 0.003, 0.002, and 0.001). This was also confirmed by SEM. In conclusion, 2% NaF reduced the adhesion of streptococci to the CpTi and TZP surfaces.


Assuntos
Aderência Bacteriana/efeitos dos fármacos , Fluoreto de Sódio/química , Streptococcus/fisiologia , Titânio/química , Zircônio/química , Adesão Celular/fisiologia , Corrosão , Peri-Implantite/prevenção & controle , Propriedades de Superfície
17.
Sci Rep ; 11(1): 3326, 2021 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-33558596

RESUMO

Oral fluids (OFs) contain small extracellular vesicles (sEVs or exosomes) that carry disease-associated diagnostic molecules. However, cells generate extracellular vesicles (EVs) other than sEVs, so the EV population is quite heterogeneous. Furthermore, molecules not packaged in EVs can also serve as diagnostic markers. For these reasons, developing a complete picture of particulate matter in the oral cavity is important before focusing on specific subtypes of EVs. Here, we used differential centrifugation to fractionate human OFs from healthy volunteers and patients with oral squamous cell carcinoma into 5 fractions, and we characterized the particles, nucleic acids, and proteins in each fraction. Canonical exosome markers, including CD63, CD9, CD133, and HSP70, were found in all fractions, whereas CD81 and AQP5 were enriched in the 160K fraction, with non-negligible amounts in the 2K fraction. The 2K fraction also contained its characteristic markers that included short derivatives of EGFR and E-cadherin, as well as an autophagosome marker, LC3, and large multi-layered vesicles were observed by electronic microscopy. Most of the DNA and RNA was recovered from the 0.3K and 2K fractions, with some in the 160K fraction. These results can provide guideline information for development of purpose-designed OF-based diagnostic systems.

18.
Dent Mater J ; 40(1): 235-244, 2021 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-32999259

RESUMO

The objective of this study was to investigate the effects of eccentric cyclic loading on implant components using the internal joint system with titanium and zirconia abutments. Abutments were made of either pure titanium (Ti group) or zirconia (TZP group). Cyclic loading test was conducted according to the specifications of ISO 14801. Loading condition was at 2 points assuming axial load and eccentric load. The reverse torque value reduced after the eccentric load and reduced more in the TZP group than the Ti group. Marginal gap changed after eccentric loading, and was greater in the TZP group. In the TZP group, changes in configuration were observed in the implant body, and Ti was detected on the abutment surface. From the above, the eccentric load may have worse effects than axial loads. It was suggested that the TZP group was clinically disadvantageous compared to the Ti group.


Assuntos
Projeto do Implante Dentário-Pivô , Titânio , Dente Suporte , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Zircônio
19.
Bull Tokyo Dent Coll ; 61(3): 161-168, 2020 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-32801259

RESUMO

Dental treatment improves the experience of eating by healing illnesses in the oral cavity or through the installation of special devices. However, mastication can often prove difficult for short periods of time after dental treatment, potentially limiting the types of food that can be consumed. Therefore, we proposed a highly nutritious meal strategy for dental outpatients (hereafter, "easy-to-eat meals"). We previously reported patients' subjective assessment of these easy-to-eat meals as determined through a questionnaire survey. The purpose of the present study was to investigate how differences in age affected such assessments. The study participants comprised patients scheduled to undergo dental treatment. They were divided into 2 groups: one of patients aged above and one of those aged below 70 years. All were required to consume provided easy-to-eat meals at the dental hospital directly after treatment and then answer a questionnaire. The questionnaire included items on patient satisfaction with the meals, taste, portion size, convenience, reduction in discomfort, and whether they would consume them again. The format of the questionnaire was a visual analog scale (VAS), ranging from 0 (negative) to 10 (positive). Portion size was to be rated on a scale from 0 ("Not enough") to 10 ("Too much"), with 5 being "Just right". Correlations between the questionnaire items were investigated to determine how they influenced each other. The VAS average for "Reduction in discomfort" was 8.45±1.39 in the non-elderly group and 6.07±2.92 in the elderly group, and the difference was significant (p=0.02); the VAS average for "Taste" was 6.49±2.32 in the non-elderly group and 4.91±0.98 in the elderly group, and the difference was significant (p=0.04). The results of this study suggest that providing such meal plans as nutritional guidance after dental treatment can influence quality of life in elderly patients.


Assuntos
Pacientes Ambulatoriais , Qualidade de Vida , Idoso , Humanos , Mastigação , Refeições , Pessoa de Meia-Idade , Inquéritos e Questionários
20.
PLoS One ; 15(6): e0234524, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32579584

RESUMO

The purpose of this study was to evaluate the adherence of streptococci to disks of titanium (commercially pure titanium: CpTi) and zirconia (tetragonal zirconia polycrystals: TZP). CpTi and yttria-stabilized TZP disks with a mirror-polished surface were used as specimens. The arithmetic mean surface roughness (Ra and Sa) and the surface wettability of the experimental specimens were measured. For analyzing the outermost layer of the experimental specimens, X-ray photoelectron spectroscopy (XPS) analysis was performed. Streptococcus sanguinis, S. gordonii, S. oralis, and S. mutans were used as streptococcal bacterial strains. These bacterial cultures were grown for 24 h on CpTi and TZP. The number of bacterial adhesions was estimated using an ATP-bioluminescent assay, and scanning electron microscope (SEM) observation of the adhered bacterial specimens was performed. No significant differences in surface roughness or wettability were found between CpTi and TZP. In XPS analyses, outermost layer of CpTi included Ti0 and Ti4+, and outermost layer of TZP included Zr4+. In the cell adhesion assay, the adherences of S. sanguinis, S. gordonii, and S. oralis to TZP were significantly lower than those to CpTi (p < 0.05); however, significant difference was not observed for S. mutans among the specimens. The adherence to CpTi and TZP of S. mutans was significantly lower than that of S. sanguinis, S. gordonii, and S. oralis. These results were confirmed by SEM. S. sanguinis, S. gordonii, and S. oralis adhered less to TZP than to CpTi, but the adherence of S. mutans was similar to both surfaces. S. mutans was less adherent compare with the other streptococci tested in those specimens.


Assuntos
Aderência Bacteriana/efeitos dos fármacos , Streptococcus sanguis/efeitos dos fármacos , Titânio/química , Zircônio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Streptococcus sanguis/química , Streptococcus sanguis/ultraestrutura , Propriedades de Superfície/efeitos dos fármacos , Ítrio/química