Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Med Case Rep ; 12(1): 350, 2018 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-30470244

RESUMO

BACKGROUND: Partial anomalous pulmonary venous return is a rare congenital cardiac anomaly that usually involves the right pulmonary vein and an atrial septal defect. Isolated partial anomalous pulmonary venous return with an intact atrial septum is even rarer, and this condition is usually treated surgically in younger patients. We describe isolated partial anomalous pulmonary venous return in a 65-year-old woman who was treated by caval division with pericardial patch baffling through a surgically created atrial septal defect and reconstruction of the superior vena cava using a prosthetic graft. CASE PRESENTATION: A 65-year-old Asian woman who presented with exertional dyspnea was diagnosed with isolated partial anomalous pulmonary venous return. The surgical indications and strategy were controversial because of the rarity of this pathology. She had an indication for surgery because she was symptomatic and had a high ratio of pulmonary to systemic blood flow. We considered that surgical procedures should avoid postoperative stenosis of a reconstructed flow tract, sinus node dysfunction, and thrombogenesis. We created a caval division with pericardial patch baffling through a surgically created atrial septal defect and reconstructed the superior vena cava using a prosthetic graft for the isolated partial anomalous pulmonary venous return. She has since remained free of exertional dyspnea, arrhythmia, and thrombotic complications. This surgical strategy is safe and effective for treating isolated partial anomalous pulmonary venous return in older symptomatic adults. CONCLUSIONS: The long-term outcome of surgical repair of partial anomalous pulmonary venous return with an intact atrial septum in our patient, a symptomatic 65-year-old woman, was excellent.


Assuntos
Septo Interatrial/patologia , Cardiopatias Congênitas/cirurgia , Veias Pulmonares/cirurgia , Veia Cava Superior/cirurgia , Idoso , Implante de Prótese Vascular , Dispneia , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Humanos , Veias Pulmonares/anormalidades , Resultado do Tratamento , Veia Cava Superior/anormalidades
2.
Kyobu Geka ; 69(6): 443-6, 2016 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-27246128

RESUMO

This case report describes emergency thoracic endovascular aortic repair (TEVAR) of a ruptured Kommerell's diverticulum associated with a type B acute aortic dissection in a patient with a right aortic arch. A 64-year-old male was admitted with symptoms of sudden paraplegia and shock. The computed tomography imaging showed right aortic arch anomaly, with mirror image branching of the major arteries. The aorta was dissected from the origin of the right subclavian artery to the terminal aorta, with a thrombosed false lumen. Rupture was found in a 6.3 cm aneurysm located in the distal arch, which was diagnosed as Kommerell's diverticulum. We performed emergency TEVAR, and the aneurysm was successfully excluded using deployment of a Gore Tag stent-graft. At 3 months' follow-up, the patient was doing well and showed shrinkage of the aneurysm was confirmed. TEVAR is considered to be a suitable procedure for an emergency aortic catastrophe even in patients with aortic anomaly.


Assuntos
Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Divertículo/cirurgia , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Divertículo/diagnóstico por imagem , Divertículo/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Ruptura Espontânea/complicações , Ruptura Espontânea/diagnóstico por imagem , Ruptura Espontânea/cirurgia , Tomografia Computadorizada por Raios X
3.
Innovations (Phila) ; 10(4): 268-72; discussion 272, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26360979

RESUMO

OBJECTIVE: The gastroepiploic artery (GEA) has been used as an alternative arterial in situ graft for coronary artery bypass grafting (CABG). However, because of the large individual differences and the spastic nature of the GEA, caution has to be exercised during harvesting. We evaluated the usefulness of fasudil, a Rho kinase inhibitor, as a vasodilator for right GEA (RGEA) graft after harvesting, compared with the conventional agents papaverine and verapamil-nitroglycerin. METHODS: Between June 2009 and January 2013, 30 patients with ischemic heart disease who underwent isolated CABG using RGEA graft were randomly assigned to fasudil (n = 10), papaverine (n = 10), or verapamil-nitroglycerin (n = 10) group. Fasudil (2.67 mmol/L), papaverine (1.0 mmol/L) mixed with heparinized blood, or verapamil-nitroglycerin (30 µmol/L each) was injected intraluminally into the RGEA graft after harvesting. Right GEA graft free flow (GFF), hemodynamic changes, and histopathology of RGEA were evaluated. RESULTS: Intraluminal injection of fasudil increased GFF significantly (P < 0.001) and markedly from 41.5 ± 31.5 mL/min at baseline to 149.3 ± 46.7 mL/min after injection. Papaverine increased GFF (P < 0.001) from 40.0 ± 35.8 to 64.9 ± 33.7 mL/min, and verapamil-nitroglycerin also increased GFF (P < 0.001) from 38.8 ± 32.1 to 79.0 ± 35.2 mL/min. The GFF was significantly higher (P = 0.001) in the fasudil group than in the other two groups. Histopathologically, fasudil treatment markedly increased the diameter of RGEA graft, while maintaining integrity of the multiple elastic lamellae. Blood pressure did not change significantly after drug injection in all groups. CONCLUSIONS: Fasudil is more potent than papaverine or verapamil-nitroglycerin in increasing GFF of RGEA graft for CABG.


Assuntos
1-(5-Isoquinolinasulfonil)-2-Metilpiperazina/análogos & derivados , Artéria Gastroepiploica/transplante , Inibidores de Proteínas Quinases/administração & dosagem , Vasodilatadores/administração & dosagem , Quinases Associadas a rho/antagonistas & inibidores , 1-(5-Isoquinolinasulfonil)-2-Metilpiperazina/administração & dosagem , Idoso , Ponte de Artéria Coronária/normas , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Feminino , Artéria Gastroepiploica/cirurgia , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/cirurgia , Nitroglicerina/administração & dosagem , Papaverina/administração & dosagem , Resultado do Tratamento , Verapamil/administração & dosagem , Verapamil/farmacologia
4.
Ann Thorac Surg ; 99(6): 2254, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26046896
5.
Transplant Direct ; 1(9): e33, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27500233

RESUMO

BACKGROUND: A novel subzero nonfreezing heart preservation method has been developed. It uses a refrigerating device that generates a variable magnetic field, allowing the whole organ to be cooled simultaneously to a supercooled state without the use of cryoprotectant. As a fundamental experiment for heart preservation, we verified whether this novel method is able to suppress anaerobic metabolism and reduce damage in the hearts of large animals. METHODS: Twelve porcine hearts were collected and preserved for 12 hours using a simple immersion method. The hearts were divided into 2 groups: 6 underwent nonfreezing preservation at -3°C in a variable magnetic field (subzero group), and 6 underwent conventional preservation at 4°C (conventional group). The quantity of anaerobic metabolism and the degree of ultrastructural change in the 2 groups were evaluated and compared. RESULTS: The concentration of adenosine triphosphate in the myocardial tissue was significantly greater in the subzero group than in the conventional group (21.06±5.87 µmol/g vs 5.96±3.41 µmol/g; P < 0.05). The accumulated lactate concentration was significantly lower in the subzero group than in the conventional group (6.58±2.28 µmol/g vs 11.15±3.74 µmol/g; P < 0.05). The Flameng score, an index of ultrastructural changes to the mitochondria, was significantly lower in the subzero group than in the conventional group (1.28±0.40 vs 2.73±0.30; P < 0.05). CONCLUSIONS: Subzero nonfreezing preservation using a variable magnetic field resulted in a remarkable suppression of anaerobic metabolism and myocardial protection in porcine hearts.

6.
Ann Thorac Surg ; 98(3): 1096-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25193197

RESUMO

The presence of isolated accessory mitral valve tissue (AMVT) is extremely rare in adults. We successfully performed robot-assisted resection of dual AMVT that was attached to the papillary muscle and anterior mitral leaflet. Echocardiography was invaluable for identifying the most suitable approach. The short-axis view on echocardiography revealed the precise location where the AMVT was attached. The robotic operation enabled fine visualization; we clearly observed the AMVT and removed its entire extra structure. The patient recovered well and was discharged 3 days after the operation. To the best of our knowledge, this is the first report of successful robotic AMVT resection.


Assuntos
Valva Mitral/anormalidades , Valva Mitral/cirurgia , Robótica , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Masculino
7.
J Thorac Cardiovasc Surg ; 148(1): 304-10, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24472314

RESUMO

OBJECTIVE: It is important for coronary active perfusion systems to avoid myocardial ischemia during off-pump coronary artery bypass grafting. We have developed a new concept for a perfusion system to pump blood based on changes in helium gas volume. This system uses a conventional intra-aortic balloon pump to activate the perfusion pump. Our study used basic and animal experiments to investigate the most suitable system for coronary perfusion using this new concept. METHODS: A conventional intra-aortic balloon pump was used to supply power. A device for perfusion was developed with a balloon placed inside a stiff syringe barrel. The device was connected to the helium gas line of the intra-aortic balloon pump. Changes in flow with changes in augmentation level were noted when volumes outside and within the balloon were changed. Six pigs with occlusion of the left anterior descending artery were used for system validation, with monitoring to identify changes in hemodynamics and cardiac enzyme levels. RESULTS: In the basic experiment, an 80-mL outside volume and 3.0-mL inner volume resulted in the greatest percentage change in flow rate with respect to changes in augmentation. In the animal experiment, the new coronary active perfusion system prevented myocardial ischemia during coronary occlusion. CONCLUSIONS: We clarified the most suitable method for our new coronary active perfusion system. Using this system, safe anastomosis was consistently performed in animal experiments. Clinically, off-pump coronary artery bypass may potentially be performed more safely and easily using this new system.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/instrumentação , Circulação Coronária , Oclusão Coronária/cirurgia , Vasos Coronários/fisiopatologia , Balão Intra-Aórtico/instrumentação , Perfusão/instrumentação , Animais , Velocidade do Fluxo Sanguíneo , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Oclusão Coronária/diagnóstico , Oclusão Coronária/fisiopatologia , Modelos Animais de Doenças , Desenho de Equipamento , Frequência Cardíaca , Fluxo Sanguíneo Regional , Suínos , Fatores de Tempo
8.
Ann Thorac Surg ; 97(3): 845-50, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24286636

RESUMO

BACKGROUND: The radial artery (RA) is a useful conduit for coronary artery bypass grafting (CABG) but is susceptible to vasospasm during harvesting. We evaluated the usefulness of fasudil, a Rho kinase inhibitor, in dilating the RA graft and increasing graft free flow (GFF) compared with the conventional graft-dilating agents papaverine and verapamil-nitroglycerin (VG). METHODS: Between June 2012 and January 2013, 45 patients with ischemic heart disease who underwent isolated CABG using the RA were enrolled and randomly assigned to fasudil (n = 15), papaverine (n = 15), or VG (n = 15). Fasudil (2.67 mmol/L), papaverine (1.0 mmol/L) mixed with heparinized blood, or VG (30 µmol/L each of verapamil and nitroglycerin) was injected intraluminally into the RA graft after harvesting. Main outcome measures were RA GFF, hemodynamic changes, and histopathologic examination of the RA. RESULTS: In the fasudil group, GFF increased significantly (p < 0.001) from 36.8 ± 20.4 at baseline to 148.0 ± 88.3 mL/min after injection. GFF increased significantly (p < 0.001) from 36.0 ± 19.0 to 72.3 ± 36.7 mL/min in the papaverine group and increased significantly (p < 0.001) from 39.5 ± 23.3 to 64.3 ± 29.9 mL/min in the VG group. The GFF was significantly higher (p = 0.001) in fasudil-treated RA than in papaverine- or VG-treated RA. Histopathologically, RA graft diameter was markedly increased after fasudil injection, and the structure of the multiple elastic lamellae was intact. Blood pressure did not change significantly after drug injection in all groups. CONCLUSIONS: Fasudil exhibited a very potent vasodilatory effect on the RA compared with conventional papaverine or VG, resulting in increased GFF. This agent is useful for dilating RA grafts in CABG.


Assuntos
1-(5-Isoquinolinasulfonil)-2-Metilpiperazina/análogos & derivados , Ponte de Artéria Coronária , Artéria Radial/efeitos dos fármacos , Vasodilatadores/farmacologia , 1-(5-Isoquinolinasulfonil)-2-Metilpiperazina/farmacologia , Idoso , Feminino , Humanos , Masculino , Nitroglicerina/farmacologia , Papaverina/farmacologia , Verapamil/farmacologia
9.
Circ J ; 78(2): 399-402, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24334565

RESUMO

BACKGROUND: The aim of this study was to assess the outcome of robot-assisted minimally invasive direct coronary artery bypass grafting (MIDCAB), which is also termed "ThoraCAB". METHODS AND RESULTS: From 2005 to 2013, 35 consecutive patients underwent MIDCAB via a small thoracotomy on a beating heart. Before performing MIDCAB, the internal thoracic arteries (ITAs) were endoscopically harvested through 3 ports using the da Vinci Surgical System in a completely skeletonized fashion. Distal anastomosis was hand-sewn using a vacuum stabilizer, and a coronary artery active perfusion system was used to prevent myocardial ischemia during anastomosis. Successful robot-assisted ITA harvesting was achieved in all patients. There was an average of 1.7±0.8 grafts (range, 1-3 grafts) per patient. No patient needed mechanical ventilation for more than 24h. There were no deaths, strokes or myocardial infarctions, and none of the patients required conversion to median sternotomy. CONCLUSIONS: Robot-assisted ITA harvesting is safe and feasible. ThoraCAB is a relatively simple procedure and allows multivessel bypass grafting after a small thoracotomy. Therefore, it is expected that ThoraCAB will become the standard procedure for minimally invasive coronary revascularization and will be used in totally endoscopic CABG in the future.


Assuntos
Ponte de Artéria Coronária , Procedimentos Cirúrgicos Minimamente Invasivos , Procedimentos Cirúrgicos Robóticos , Idoso , Ponte de Artéria Coronária/instrumentação , Ponte de Artéria Coronária/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos
10.
Thorac Cardiovasc Surg ; 62(3): 261-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23344753

RESUMO

Thoracic reconstruction in patients with pectus excavatum with concomitant cardiac or aortic surgery poses a major clinical challenge. The report describes two cases of adult patients undergoing simultaneous surgical correction of cardiac disease and sternal deformity using one of two different techniques: a sterno-turnover method preserving the rectus muscle or a sternal elevation method with A-O plates.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Tórax em Funil/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Valva Mitral/cirurgia , Procedimentos Ortopédicos , Adulto , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico , Feminino , Tórax em Funil/complicações , Tórax em Funil/diagnóstico , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Masculino , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
11.
Ann Thorac Surg ; 96(2): 543-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23773733

RESUMO

BACKGROUND: The internal thoracic artery (ITA) is a very useful conduit for coronary artery bypass artery (CABG), with excellent long-term patency. With the purpose to dilate the ITA graft and increase graft free flow (GFF) intraoperatively, we evaluated the usefulness of intraluminal injection of fasudil, a Rho-kinase inhibitor, in comparison to the conventional graft dilating agent, papaverine. METHODS: Between June 2011 and January 2012, 30 patients with ischemic heart disease who underwent isolated CABG using ITA were enrolled. The patients were randomly assigned to 2 groups: the fasudil group (n = 15) in which fasudil solution 0.9 mg/dL was injected into the ITA, and the papaverine group (n = 15) in which papaverine solution (0.4 mg/mL) mixed with heparinized blood was used. Outcome measures were left ITA GFF, heart rate, and mean blood pressure during flow measurements, and histopathologic examination of the ITA. RESULTS: In the fasudil group, GFF increased significantly (p < 0.01) from 19.7 ± 15.2 mL/minute at baseline to 66.9 ± 31.7 mL/minute after fasudil injection. In the papaverine group, GFF increased significantly (p < 0.01) from 22.9 ± 17.3 mL/minute at baseline to 44.8 ± 26.7 mL/minute after papaverine injection. Blood pressure and heart rate did not change significantly after drug injection in both groups. The GFF was significantly higher (p = 0.038) in fasudil-treated ITA than in papaverine-treated ITA. Histopathologically, the diameter of the ITA was markedly increased after fasudil injection. Elastica van Gieson staining showed that the multiple elastic lamellae structure was intact. CONCLUSIONS: Fasudil exhibited very potent vasodilatory effect on the ITA compared with conventional papaverine resulting in increased GFF. This agent is a useful graft dilating agent.


Assuntos
1-(5-Isoquinolinasulfonil)-2-Metilpiperazina/análogos & derivados , Ponte de Artéria Coronária , Artéria Torácica Interna/efeitos dos fármacos , Papaverina/farmacologia , Vasodilatadores/farmacologia , 1-(5-Isoquinolinasulfonil)-2-Metilpiperazina/farmacologia , Idoso , Ponte de Artéria Coronária/métodos , Feminino , Humanos , Masculino , Artéria Torácica Interna/cirurgia
12.
Asian Cardiovasc Thorac Ann ; 21(1): 14-21, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23430415

RESUMO

OBJECTIVE: To evaluate the changes in cerebral blood flow during awake off-pump coronary artery bypass grafting and compare with the changes during off-pump coronary artery bypass grafting under general anesthesia, using continuous monitoring of regional cerebral oxygen saturation. METHODS: The study population comprised 3 groups of patients who had undergone off-pump coronary artery bypass grafting with thoracic epidural anesthesia, general anesthesia, or a combination of the two. Regional brain oxygen saturation, determined with a near-infrared oxygen monitor, and mean arterial pressure during surgery were calculated and compared among the 3 groups. RESULTS: Patients who had undergone awake off-pump coronary artery bypass grafting with thoracic epidural anesthesia had a significantly higher cerebrovascular impairment ratio, and the EuroSCORE was high. No significant differences were observed among the 3 groups in terms of the relationship between mean arterial pressure during surgery and regional brain oxygen saturation. It is suggested that there were no differences in cerebral blood flow and mean arterial pressure changes among the 3 groups. CONCLUSIONS: Awake off-pump coronary artery bypass grafting is a safe surgical technique for patients with history of cerebral infarction or impaired cerebral blood flow. Awake off-pump coronary artery bypass grafting is a less invasive procedure that allows efficient management of intraoperative cerebral blood flow, and can be equally effective as a percutaneous coronary intervention.


Assuntos
Anestesia Epidural , Anestesia Geral , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Ponte de Artéria Coronária sem Circulação Extracorpórea , Monitorização Intraoperatória/métodos , Oxigênio/sangue , Espectroscopia de Luz Próxima ao Infravermelho , Vigília , Idoso , Pressão Arterial , Biomarcadores/sangue , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco
15.
Kyobu Geka ; 64(6): 503-5, 2011 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-21682051

RESUMO

Primary cardiac tumors are relatively rare. No therapeutic guidelines have been established for the surgical indications of such cases. This creates therapeutic dilemmas, especially when the patient is asymptomatic. We describe the robot-assisted resection of an asymptomatic right atrial lipoma. A 63-year-old female was diagnosed to have a round mobile lipoma, measuring 27 mm in diameter in the right atrium near the junction with the inferior vena cava (IVC). Although she was asymptomatic, a surgical resection was indicated since the lipoma could cause an embolism or IVC obstruction due to its morbidity and potential to enlarge. Surgery was performed using the da Vinci Surgical System. A right-sided approach was used through 4 ports. The tumor was resected with a small portion of the right atrial wall. The total operation time was 214 minutes, and the total pump time was 84 minutes. The operation was performed while the heart was beating.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Átrios do Coração , Neoplasias Cardíacas/cirurgia , Lipoma/cirurgia , Robótica , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
16.
Eur J Cardiothorac Surg ; 40(4): 788-93, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21459602

RESUMO

OBJECTIVE: The ultimate goal of minimally invasive coronary artery bypass grafting (CABG) is day surgery. We evaluated the potential of a new awake CABG protocol using only epidural anesthesia in realizing day surgery. METHODS: Seventy-two patients who underwent awake off-pump CABG (OPCAB) in our institute from March 2003 were studied. One day before surgery, an epidural catheter was placed at the Th1-2 interspace. On the day of surgery, local anesthetics were delivered via the catheter to provide a level of epidural block from C6 to Th8. Among 1260 patients who underwent OPCAB under general anesthesia (GA) during this study period, 67 of them who matched for age and gender with the awake OPCAB group were selected as controls (GA group). Postoperative fast-track recovery was evaluated. RESULTS: In 67 of the 72 patients (93%), awake OPCAB under consciousness and spontaneous breathing was fully accomplished. Five patients had to be administered GA. Ten patients (14.9%) were able to leave the operating room in a wheelchair. The time to drink water, the time to walk, and hospital stay were significantly shorter in awake OPCAB group than in the GA group. There were no operative and postoperative complications or deaths. CONCLUSIONS: Despite the presence of severe preoperative comorbidities in this series, good surgical outcome was obtained. Almost all the patients were able to drink water and walk very soon after surgery, suggesting the potential of this protocol as one-day or day surgery. Awake OPCAB is a promising modality of ultra-minimally invasive cardiac surgery.


Assuntos
Anestesia Epidural/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Doença das Coronárias/cirurgia , Idoso , Anestesia Epidural/efeitos adversos , Anestesia Geral , Dióxido de Carbono/sangue , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Doença das Coronárias/patologia , Estudos de Viabilidade , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Oxigênio/sangue , Pressão Parcial , Período Pós-Operatório , Vértebras Torácicas , Resultado do Tratamento
17.
Surg Today ; 41(3): 399-401, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21365423

RESUMO

A 40-year-old woman who was diagnosed to have systemic lupus erythematosus developed complications of cerebral infarction and alveolar hemorrhage. Close examination revealed severe aortic insufficiency, and she was diagnosed with Libman-Sacks syndrome. Due to progressive dilatation of the left ventricle and her easily fatigued state, surgery was performed. On pathological examination, holes of 4-mm and 5-mm diameter were detected in the left coronary and noncoronary cusps of the aortic valve, respectively. The morphology of the valve lesions showed a characteristic shape of such huge holes.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/métodos , Lúpus Eritematoso Sistêmico/complicações , Adulto , Valva Aórtica , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Seguimentos , Humanos , Lúpus Eritematoso Sistêmico/diagnóstico , Ruptura Espontânea , Índice de Gravidade de Doença , Síndrome , Tomografia Computadorizada por Raios X
18.
Ann Thorac Surg ; 91(2): 619-20, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21256336

RESUMO

We report a technique of injecting a high concentration of potassium chloride into the aorta root to resolve refractory ventricular tachycardia after aortic declamping, which occurs occasionally in open heart surgeries. Using this technique, normal sinus rhythm can be restored without the need for defibrillation and aortic clamping.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Cloreto de Potássio/administração & dosagem , Instrumentos Cirúrgicos/efeitos adversos , Taquicardia Ventricular/tratamento farmacológico , Fibrilação Ventricular/tratamento farmacológico , Idoso , Aorta , Ponte Cardiopulmonar/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Miocárdio/metabolismo , Soluções , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia
19.
J Thorac Cardiovasc Surg ; 141(5): 1265-9, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20947100

RESUMO

OBJECTIVE: This study applied a computer-controlled mechanical stapler to vascular end-to-end anastomosis to achieve an automatic aortic anastomosis between the aorta and an artificial graft. In this experimental study, we created a mechanical end-to-end anastomotic model and assessed the strength of the anastomotic site under high pressure. METHODS: We used a computer-controlled circular stapler named iDrive (Power Medical Interventions, Covidien plc, Dublin, Ireland) for the anastomosis between the porcine aorta and an artificial graft. Then the mechanically stapled group (group A) and the manually sutured group (group B) were compared 10 times, and we assessed the differences at several levels of pressure. RESULTS: To use a mechanical stapler in vascular anastomosis, some special preparations of both the aorta and the artificial graft are necessary to narrow the open end before the procedures. To solve this problem, we established a specially designed purse-string suture for both and finally established end-to-end vascular anastomosis. The anastomosis speed of group A was statistically significantly faster than that of group B (P < .01). The group A anastomotic sites also showed significantly more tolerance to high pressure than those of group B. CONCLUSIONS: The computer-controlled stapling device enabled reliable anastomosis of the aorta and the artificial graft. This study showed that mechanical vascular anastomosis with the iDrive was sufficiently strong and safe relative to manual suturing.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Cirurgia Assistida por Computador/instrumentação , Grampeadores Cirúrgicos , Grampeamento Cirúrgico/instrumentação , Técnicas de Sutura , Anastomose Cirúrgica , Animais , Automação , Implante de Prótese Vascular/efeitos adversos , Desenho de Equipamento , Teste de Materiais , Modelos Animais , Pressão , Cirurgia Assistida por Computador/efeitos adversos , Grampeamento Cirúrgico/efeitos adversos , Suínos
20.
Innovations (Phila) ; 6(5): 311-5, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22436707

RESUMO

OBJECTIVE: : The continuous suture technique has numerous advantages as simple, quick, and effective for aortic valve replacement; however, it is technically difficult. We have modified the continuous suture technique and evaluated our new technique in patients with aortic stenosis. METHODS: : Between July 2007 and May 2010, 86 patients with aortic valve stenosis underwent aortic valve replacement alone or with other concomitant cardiac procedures including mitral valve surgery in our hospital. The patients were randomly divided into two groups: group A (n = 43) in which the continuous suture technique with some modifications was used and group B (n = 43) in which the conventional interrupted suture technique was used. There were no statistical differences between two groups in age, sex, body surface area, concomitant cardiac procedures, blood loss, and postoperative extubation time. RESULTS: : The aortic cross-clamp time, cardiopulmonary bypass time, operation time, and hospital stay were significantly shorter in group A than that in group B, and the valve size was significantly larger in group A. No perivalvular leak was detected in postoperative echocardiograms. All patients recovered satisfactorily without complications associated with suture technique or prosthesis. During follow-up of 4 to 38 months, there were no clinically significant complications in group A, while one patient in group B developed perivalvular leakage requiring reoperation 3 months after surgery. CONCLUSIONS: : Our modified continuous suture method is useful for aortic valve replacement in patients with aortic stenosis and beneficial for the patients because the procedure is less invasive and a larger valve can be implanted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA