Vet Anaesth Analg ; 48(3): 297-304, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33610477

RESUMO

OBJECTIVE: To compare values of haemoglobin concentration (SpHb), arterial haemoglobin saturation (SpO2) and calculated arterial oxygen content (SpOC), measured noninvasively with a pulse co-oximeter before and after in vivo adjustment (via calibration of the device using a measured haemoglobin concentration) with those measured invasively using a spectrophotometric-based blood gas analyser in anaesthetized dogs. STUDY DESIGN: Prospective observational clinical study. ANIMALS: A group of 39 adult dogs. METHODS: In all dogs after standard instrumentation, the dorsal metatarsal artery was catheterised for blood sampling, and a pulse co-oximeter probe was applied to the tongue for noninvasive measurements. Paired data for SpHb, SpO2 and SpOC from the pulse co-oximeter and haemoglobin arterial oxygen saturation (SaO2) and arterial oxygen content (CaO2) from the blood gas analyser were obtained before and after in vivo adjustment. Bland-Altman analysis for repeated measurements was used to evaluate the bias, precision and agreement between the pulse co-oximeter and the blood gas analyser. Data are presented as mean differences and 95% limits of agreement (LoA). RESULTS: A total of 39 data pairs were obtained before in vivo adjustment. The mean invasively measured haemoglobin-SpHb difference was -2.7 g dL-1 with LoA of -4.9 to -0.5 g dL-1. After in vivo adjustment, 104 data pairs were obtained. The mean invasively measured haemoglobin-SpHb difference was -0.2 g dL-1 with LoA of -1.1 to 0.6 g dL-1. The mean SaO2-SpO2 difference was 0.86% with LoA of -0.8% to 2.5% and that between CaO2-SpOC was 0.66 mL dL-1 with LoA of -2.59 to 3.91 mL dL-1. CONCLUSIONS: Before in vivo adjustment, pulse co-oximeter derived values overestimated the spectrophotometric-based blood gas analyser haemoglobin and CaO2 values. After in vivo adjustment, the accuracy, precision and LoA markedly improved. Therefore, in vivo adjustment is recommended when using this device to monitor SpHb in anaesthetised dogs.


Assuntos
Hemoglobinas , Oximetria , Animais , Gasometria/veterinária , Cães , Hemoglobinas/análise , Oximetria/veterinária , Oxigênio , Reprodutibilidade dos Testes , Tecnologia
2.
Vet Anaesth Analg ; 44(3): 492-501, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28528758

RESUMO

OBJECTIVE: To assess agreement between noninvasive blood pressure (NIBP) oscillometrically-derived values from a multiparameter monitor (Datex Ohmeda S/5 Compact) with those obtained by invasive blood pressure (IBP) measurement in anaesthetised horses undergoing elective surgery. STUDY DESIGN: Prospective clinical study. ANIMALS: A total of 40 healthy adult horses. METHODS: Horses were anaesthetised with various anaesthetic protocols (based on clinical requirements). Depending on positioning, cannulation of the facial or lateral metatarsal artery was performed for IBP measurement. The cannula was connected via a transducer to the monitor. An appropriately sized NIBP cuff was placed around the tail base and connected to the same monitor. Systolic (SAP), mean (MAP) and diastolic (DAP) arterial blood pressures were continuously recorded from the invasive system, and at 3 minute intervals from the oscillometric system, throughout the surgical procedure using a Datex iCollect program. An appropriate arithmetic correction factor was applied to the oscillometric results where the cuff was not level with the heart. Assessment of the degree of agreement between invasive and noninvasive readings at each time point was performed using a modified Bland-Altman analysis. RESULTS: While in many horses there was relatively close correlation between the values obtained over time, there was substantial variability in individual animals which resulted in wide Bland-Altman limits of agreement. The oscillometric device over-reads by approximately 32, 23 and 22 mmHg, and under-reads by 26, 17 and 19 mmHg for SAP, MAP and DAP, respectively, compared with the IBP values. However, using the mean difference and standard deviation, the device conforms to American College of Veterinary Internal Medicine (ACVIM) standards. CONCLUSIONS AND CLINICAL RELEVANCE: Oscillometric blood pressure measurement using the Datex Ohmeda S/5 Compact multiparameter monitor conforms to ACVIM standards when the NIBP cuff is placed on the tail. However, because of the wide variability in measurements, we cannot recommend this technique to guide therapy in anaesthetised adult horses.


Assuntos
Anestesia/veterinária , Determinação da Pressão Arterial/veterinária , Monitores de Pressão Arterial/veterinária , Oscilometria/veterinária , Anestesia/métodos , Animais , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/normas , Monitores de Pressão Arterial/normas , Procedimentos Cirúrgicos Eletivos/veterinária , Cavalos , Medicação Pré-Anestésica/métodos , Medicação Pré-Anestésica/veterinária , Estudos Prospectivos