Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 38(4): 1784-1790, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38286838

RESUMO

BACKGROUND AND AIMS: This retrospective study aimed to compare the short- and long-term outcomes of endoscopic submucosal dissection and laparoscopic and endoscopic cooperative surgery in patients with superficial non-ampullary duodenal epithelial tumors. PATIENTS AND METHODS: We investigated consecutive patients with SNADETs > 10 mm in size who underwent ESD (ESD group) or LECS (LECS group) between January 2015 and March 2021. The data was used to analyze the clinical course, management, survival status, and recurrence between the two groups. RESULTS: A total of 113 patients (100 and 13 in the ESD and LECS groups, respectively) were investigated. The rates of en bloc resection and curative resection were 100% vs. 100% and 93.0% vs. 77.0% in the ESD and LECS groups, respectively, with no significant difference. The ESD group had shorter resection and suturing times than the LECS group, but there were no significant difference after propensity score matching. There were also no differences in the rates of postoperative adverse event (7.0% vs. 23.1%; P = 0.161). The 3-year overall survival (OS) rate was high in both the ESD and LECS groups (97.6% vs. 100%; P = 0.334). One patient in the ESD group experienced recurrence due to liver metastasis; however, no deaths related to SNADETs were observed. CONCLUSION: ESD and LECS are both acceptable treatments for SNADETs in terms of a high OS rate and a low long-term recurrence rate, thereby achieving a comparable high rate of curative resection. Further studies are necessary to compare the outcomes of ESD and LECS for SNADETs once both techniques are developed further.


Assuntos
Ressecção Endoscópica de Mucosa , Laparoscopia , Neoplasias Epiteliais e Glandulares , Humanos , Estudos Retrospectivos , Ressecção Endoscópica de Mucosa/métodos , Resultado do Tratamento , Laparoscopia/métodos
2.
Jpn J Clin Oncol ; 54(2): 137-145, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-37869773

RESUMO

BACKGROUND AND OBJECTIVE: Several endoscopic resection methods have been developed as less invasive treatments for superficial non-ampullary duodenal epithelial tumours. This study aimed to compare outcomes of conventional endoscopic mucosal resection and underwater endoscopic mucosal resection for superficial non-ampullary duodenal epithelial tumours, including resection depth and rate of the muscularis mucosa contained under the lesion. METHODS: This single-centre retrospective cohort study conducted from January 2009 to December 2021 enrolled patients who underwent conventional endoscopic mucosal resection and underwater endoscopic mucosal resection for superficial non-ampullary duodenal epithelial tumours and investigated their clinicopathological outcomes using propensity score matching. RESULTS: Of the 285 superficial non-ampullary duodenal epithelial tumours, 98 conventional endoscopic mucosal resections and 187 underwater endoscopic mucosal resections were included. After propensity score matching, 64 conventional endoscopic mucosal resections and 64 underwater endoscopic mucosal resections were analysed. The R0 resection rate was significantly higher in underwater endoscopic mucosal resection cases than in conventional endoscopic mucosal resection cases (70.3% vs. 50.0%; P = 0.030). In the multivariate analysis, a lesion diameter > 10 mm (odds ratio 7.246; P = 0.001), being in the 1st-50th treatment period (odds ratio 3.405; P = 0.008), and undergoing conventional endoscopic mucosal resection (odds ratio 3.617; P = 0.016) were associated with RX/R1 resection. Furthermore, in underwater endoscopic mucosal resection cases, the R0 rate was significantly higher for lesions diameter ≤10 mm than >10 mm, and was significantly higher in the 51st-treatment period than in the 1st-50th period. Conventional endoscopic mucosal resection and underwater endoscopic mucosal resection cases showed no significant difference in resection depth and muscularis mucosa containing rate. CONCLUSIONS: Underwater endoscopic mucosal resection may be more acceptable than conventional endoscopic mucosal resection for superficial non-ampullary duodenal epithelial tumours ≤ 10 mm. A steep early learning curve may be acquired for underwater endoscopic mucosal resection. Large multicentre prospective studies need to be conducted to confirm the effectiveness of underwater endoscopic mucosal resection.


Assuntos
Carcinoma , Neoplasias Duodenais , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Endoscopia , Neoplasias Duodenais/patologia
3.
Dig Endosc ; 36(2): 215-220, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37983598

RESUMO

Conventional clip closure of mucosal defects after duodenal endoscopic submucosal dissection decreases the incidence of delayed adverse events, but may result in incomplete closure, depending on size or location. This study aimed to assess the effectiveness of the underwater clip closure method for complete duodenal defect closure without the difficulties associated with conventional closure methods. We investigated 19 patients with 20 lesions who underwent endoscopic submucosal dissection of the duodenum and subsequent mucosal defect closure in underwater conditions at our facility between February 2021 and January 2022. The success rate of the underwater clip closure method was defined as the complete endoscopic closure of the mucosal defect; a success rate of 100% was achieved. The median resected specimen size was 34.3 mm, the median procedure time for mucosal defect closure was 14 min, and the median number of clips used per patient was 12. No delayed adverse events were observed. The underwater clip closure method is a feasible option for complete closure of mucosal defects, regardless of the size or location of a duodenal endoscopic submucosal dissection.


Assuntos
Ressecção Endoscópica de Mucosa , Humanos , Ressecção Endoscópica de Mucosa/métodos , Duodeno/cirurgia , Técnicas de Fechamento de Ferimentos , Mucosa Intestinal/cirurgia , Instrumentos Cirúrgicos , Resultado do Tratamento , Estudos Retrospectivos
4.
Environ Int ; 180: 108199, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37713971

RESUMO

Accurate quantification of infectious contaminants on environmental surfaces, particularly infectious viruses, is essential for contact transmission risk assessment; however, difficulties in recovering viruses from surfaces using swabs complicates this quantification process. Herein, we identified the factors that significantly affected virus recovery rates and developed an ideal swab method that yielded the highest rate of virus recovery. We comprehensively analyzed the effects of swab type (cotton/polyester), swab water content (wet/dry conditions), surface material, and surface area on the rates of viral RNA and infectious virus recovery. The virus recovery rate was significantly lower than the viral RNA recovery rate (P < 0.01), indicating difficulty in the quantification of infectious viruses. The virus recovery rate was significantly higher under wet conditions than that under dry conditions (P < 0.006), and the virus recovery rate obtained using cotton swabs was significantly higher than that using polyester swabs (P < 0.0001). Furthermore, the virus recovery rate had a strong negative correlation (correlation coefficient >0.8) with the target surface area. The maximum surface area where the virus recovery rate was ≥10% (MSA-10%) was identified as the maximum quantifiable area. For influenza virus recovery, MSA-10% on polyvinyl chloride (PVC) sheet, PVC leather, stainless steel, silicone, glass, and polycarbonate surfaces was 66.7, 193, 60.2, 144, 105, and 15.6 cm2, respectively. For feline calicivirus recovery, MSA-10% on PVC sheet, PVC leather, stainless steel, silicone, glass, and polycarbonate surfaces was 210, 111, 2120, 250, 322, and 180 cm2, respectively. The most accurate and ideal method for quantifying infectious viruses on environmental surfaces with the highest recovery rates meets three specifications: "wet conditions," "the use of cotton swabs," and "a target surface area of approximately 10 cm2.

5.
Dig Endosc ; 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37682639

RESUMO

OBJECTIVES: Cold snare polypectomy (CSP)-dedicated snares (DSs) may have a higher resection ability than conventional snares. However, a model that can accurately and objectively evaluate and compare the resection ability of each snare has yet to be determined, and characteristics of snare parts that increase resection ability remain unknown. Therefore, we elucidated DSs' resection ability and all characteristics of the parts required for acquiring high resection ability. METHODS: An ex vivo model for evaluating resection ability was generated using human colons obtained from forensic autopsy specimens. The force required to resect a 15 mm wide human colonic mucosa (FRR) was measured using this model; if the FRR is small, the resection ability is high. Next, after measuring the stiffness of each snare part, the correlation between the stiffness and resection ability was analyzed. RESULTS: The force required to resect using SnareMaster Plus, Micro-Tech Cold Snare, Captivator Cold, Exacto Cold Snare, or Captivator II was 13.6 ± 1.0, 12.5 ± 1.2, 7.4 ± 1.2, 6.5 ± 1.0, and 28.7 ± 3.7 N, respectively. All DSs had significantly lower FRR than the conventional snare (Captivator II) and had higher resection ability (P < 0.001). A negative correlation was found between FRR and sheath or wire spindle stiffness, with correlation coefficients of 0.72 (P = 0.042) or 0.94 (P < 0.001), respectively. Moreover, 1 × 7 type wire rings had significantly higher friction coefficients than 1 × 3 type wire rings (P < 0.002). CONCLUSION: Sheath and wire spindle stiffness should be increased to increase resection ability; 1 × 7 type wire rings may be suitable for CSP-snare parts.

6.
Microbiol Spectr ; : e0238122, 2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36840603

RESUMO

The environmental stability of human coronavirus OC43 (HCoV-OC43) on the surface of human skin and the effectiveness of disinfectant against HCoV-OC43, which are important to prevent contact transmission, have not been clarified in previous studies. Using previously generated models, we evaluated HCoV-OC43 stability and disinfection effectiveness. Then we compared the results with those for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The median survival time of HCoV-OC43 on the surface of human skin was 24.6 h (95% confidence interval, 19.7 to 29.6 h), which was higher than that of SARS-CoV-2 (10.8 h). Although the in vitro disinfectant effectiveness evaluation showed that HCoV-OC43 has a higher ethanol resistance than SARS-CoV-2, HCoV-OC43 on the skin surface was completely inactivated by a minimum of 50% ethanol within 5 s (the log reduction values were >4.0). Moreover, 1.0% chlorhexidine gluconate and 0.2% benzalkonium chloride showed relatively high disinfectant effectiveness, and the log reduction values when these disinfectants were applied for 15 s were >3.0. HCoV-OC43 is highly stable on the skin surface, which may increase the risk of contact transmission. Although HCoV-OC43 has relatively high ethanol resistance, appropriate hand hygiene practices with current alcohol-based disinfectants sufficiently reduce the risk of contact transmission. IMPORTANCE This study revealed the environmental stability of HCoV-OC43 and disinfectant effectiveness against HCoV-OC43, which had not been demonstrated in previous studies. HCoV-OC43 is highly stable on the surface of human skin, with a survival time of approximately 25 h. High stability of HCoV-OC43 may increase the risk of contact transmission. Furthermore, the in vitro disinfectant effectiveness evaluation showed that HCoV-OC43, which is classified as an envelope virus, has a relatively high ethanol resistance. This finding suggests that disinfectant effectiveness may vary greatly depending on the virus and that each virus targeted for infection control should be evaluated individually. HCoV-OC43 on the skin surface was rapidly inactivated by 50% ethanol, which suggests that appropriate hand hygiene practices with current alcohol-based disinfectants can sufficiently reduce the risk of HCoV-OC43 contact transmission.

7.
Clin J Gastroenterol ; 15(5): 881-885, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35917108

RESUMO

Gastric mucosa-associated lymphoid tissue (MALT) lymphomas have various endoscopic appearances. We report a case of Helicobacter pylori-negative gastric MALT lymphoma with a protruding morphology similar to that of submucosal tumors. A 51-year-old man with a protruding tumor in the gastric cardia was referred to our hospital. Biopsy specimens showed no malignant epithelial tumors or lymphoid hyperplasia. Endoscopic submucosal dissection was performed and the patient was diagnosed with gastric MALT lymphoma. Lymphoma cells were present in the lamina propria mucosae and the submucosa under the non-atrophic fundic gland mucosa, with a feature of homogenous and monotonous growths, which was speculated to have resulted in a protruding morphology similar to that of submucosal tumors. Endoscopic submucosal dissection can be an alternative diagnostic option for gastric MALT lymphoma when the initial pathological diagnosis based on biopsy specimens is difficult.


Assuntos
Ressecção Endoscópica de Mucosa , Infecções por Helicobacter , Helicobacter pylori , Linfoma de Zona Marginal Tipo Células B , Neoplasias Gástricas , Ressecção Endoscópica de Mucosa/efeitos adversos , Mucosa Gástrica/patologia , Mucosa Gástrica/cirurgia , Infecções por Helicobacter/complicações , Humanos , Linfoma de Zona Marginal Tipo Células B/diagnóstico por imagem , Linfoma de Zona Marginal Tipo Células B/cirurgia , Linfoma não Hodgkin , Masculino , Pessoa de Meia-Idade , Estômago/patologia , Neoplasias Gástricas/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA