Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Curr Probl Surg ; 61(10): 101559, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39266126

RESUMO

PURPOSE: Our aim was to develop practical training for laparoscopic surgery using Thielembalmed cadavers. Furthermore, in order to verbalize experts' motion characteristics and provide objective feedback to trainees, we initiated motion capture analyses of multiple surgical instruments simultaneously during the cadaveric trainings. In the present study, we report our preliminary results. METHODS: Participants voluntarily joined the present cadaveric simulation trainings, and performed laparoscopic radical nephrectomy. After the trainings, scores for tissue similarity (face validity) and impression of educational merit (content validity) were collected from participants based on a 5-point Likert scale (tissue similarity: 5: very similar, 3: average, 1: very different; educational merit: 5: very high, 3: average, 1: very low). In addition, after the additional IRB approval, we started motion capture (Mocap) analyses of 6 surgical instruments (scissors, vessel sealing system, grasping forceps, clip applier, right-angled forceps, and suction), using an infrared trinocular camera (120-Hz location record). Mocap-metrics were compared according to the previous surgical experiences (experts: ≧50 laparoscopic surgeries, intermediates: 10-49, novices: 0-9), using the Kruskal-Wallis test. RESULTS: A total of 9 experts, 19 intermediates, and 15 novices participated in the present study. In terms of face validity, the mean scores were higher than 3, other than for the Vena cava(mean score of 2.89). Participants agreed with the training value (usefulness for future skill improvement: mean score of 4.57). In terms of Mocap analysis, faster speed-related metrics (e.g., velocity, the distribution of tip velocity, acceleration, and jerk) in the scissors and vessel sealing system, a shorter path length of grasping forceps, and fewer dimensionless squared jerks, which indicated more purposeful motion of 4 surgical instruments (vessel sealing system, grasping forceps, clip applier and suction), were observed in the more experienced group. CONCLUSIONS: The Thiel-embalmed cadaver provides an excellent training opportunity for complex laparoscopic procedures with participants' high level of satisfaction, and may become a promising tool for a better objective understanding of surgical dexterity. In order to enrich formative feedback to trainees, we are now proceeding with Mocap analysis.


Assuntos
Cadáver , Competência Clínica , Embalsamamento , Laparoscopia , Nefrectomia , Treinamento por Simulação , Humanos , Laparoscopia/educação , Nefrectomia/educação , Nefrectomia/métodos , Treinamento por Simulação/métodos , Embalsamamento/métodos , Masculino , Feminino
2.
PLoS One ; 19(6): e0305693, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38917181

RESUMO

This study developed and validated a surgical instrument motion measurement system for skill evaluation during practical laparoscopic surgery training. Owing to the various advantages of laparoscopic surgery including minimal invasiveness, this technique has been widely used. However, expert surgeons have insufficient time for providing training to beginners due to the shortage of surgeons and limited working hours. Skill transfer efficiency has to be improved for which there is an urgent need to develop objective surgical skill evaluation methods. Therefore, a simple motion capture-based surgical instrument motion measurement system that could be easily installed in an operating room for skill assessment during practical surgical training was developed. The tip positions and orientations of the instruments were calculated based on the marker positions attached to the root of the instrument. Because the patterns of these markers are individual, this system can track multiple instruments simultaneously and detect exchanges. However due to the many obstacles in the operating room, the measurement data included noise and outliers. In this study, the effect of this decrease in measurement accuracy on feature calculation was determined. Accuracy verification experiments were conducted during wet-lab training to demonstrate the capability of this system to measure the motion of surgical instruments with practical accuracy. A surgical training experiment on a cadaver was conducted, and the motions of six surgical instruments were measured in 36 cases of laparoscopic radical nephrectomy. Outlier removal and smoothing methods were also developed and applied to remove the noise and outliers in the obtained data. The questionnaire survey conducted during the experiment confirmed that the measurement system did not interfere with the surgical operation. Thus, the proposed system was capable of making reliable measurements with minimal impact on surgery. The system will facilitate surgical education by enabling the evaluation of skill transfer of surgical skills.


Assuntos
Competência Clínica , Laparoscopia , Laparoscopia/educação , Humanos , Instrumentos Cirúrgicos , Movimento (Física) , Cadáver , Nefrectomia/educação , Nefrectomia/métodos
3.
Front Neurol ; 14: 1296902, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38333185

RESUMO

Based on the average human body size in China and the THUMS AM50 finite element model of the human body, the Kriging interpolation algorithm was used to model the Chinese 50th percentile human body, and the biological fidelity of the model was verified. We built three different types of passenger vehicle models, namely, sedan, sports utility vehicle (SUV), and multi-purpose vehicle (MPV), and used mechanical response analysis and finite element simulation to compare and analyze the dynamic differences and head injury differences between the Chinese 50th percentile human body and the THUMS AM50 model during passenger vehicle collisions. The results showed that there are obvious differences between the Chinese mannequin and THUMS in terms of collision time, collision position, invasion speed, and angle. When a sedan collided with the mannequins, the skull damage to the Chinese human body model was more severe, and when a sedan or SUV collided, the brain damage to the Chinese human body was more severe. The abovementioned results suggest that the existing C-NCAP pedestrian protection testing regulations may not provide the best protection for Chinese human bodies, and that the regulations need to be improved by combining collision damage mechanisms and the physical characteristics of Chinese pedestrians. This thorough investigation is positioned to shed light on the fundamental biomechanics and injury mechanisms at play. Furthermore, the amalgamation of clinically rooted translational and engineering research in the realm of traumatic brain injury has the potential to establish a solid foundation for discerning preventive methodologies. Ultimately, this endeavor holds the potential to introduce effective strategies aimed at preventing and safeguarding against traumatic brain injuries.

4.
J Cogn Psychother ; 2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33397786

RESUMO

Family accommodation is a phenomenon that has been associated with worse treatment outcome of patients with obsessive-compulsive disorder (OCD) and greater severity of symptoms and levels of functional impairment. Yet, there are no Chinese scales to assess family accommodation in OCD among family members. The present study aimed to illustrate the steps of translation and cross-cultural adaptation of the Chinese versions of the Family Accommodation Scale (FAS). After obtaining authorization of the developers, the Chinese versions of the FAS were translated and adapted from the English versions based on a standard protocol, following six steps: forward translation, pilot administration, language adjustment and cultural adaptation, back-translation, review and minor edit, and final approval of the developer. Thirty-five pairs of patients and corresponding relatives with different education levels were administered the FAS in the pretest stage. This study found that the semantic, idiomatic, and conceptual equivalence were obtained between the Chinese versions and original English scales, and the Chinese versions of FAS were well translated and culturally adapted. We also found that the Chinese versions of the FAS can be easily understood by people of different socioeconomic statuses.

5.
ACS Appl Mater Interfaces ; 12(38): 43009-43017, 2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32856459

RESUMO

Flexible and stretchable strain sensors are vital for emerging fields of wearable and personal electronics, but it is a huge challenge for them to possess both wide-range measurement capability and good sensitivity. In this study, a highly stretchable strain sensor with a wide strain range and a good sensitivity is fabricated based on smart composites of carbon black (CB)/wrinkled Ecoflex. The sensor exhibits a maximum recoverable strain of up to 500% and a high gauge factor of 67.7. It has a low hysteresis, a fast signal response (as short as 120 ms), and a high reproducibility (up to 5000 cycles with a strain of 150%). The sensor is capable of detecting and capturing wide-range human activities, from speech recognition and pulse monitoring to vigorous motions. It is also applicable for real-time monitoring of robot movements and vehicle security crash in an anthropomorphic field. More importantly, the sensor is successfully used to send signals of a volunteer's breathing data to a local hospital in real time through a big data cloud platform. This research provides the feasibility of using a strain sensor for wearable Internet of things and demonstrates its exciting prospect for healthcare applications.


Assuntos
Big Data , Computação em Nuvem , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica , Tamanho da Partícula , Fuligem/química , Propriedades de Superfície
6.
Sensors (Basel) ; 20(7)2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-32290183

RESUMO

Due to the complex visual environment, such as lighting variations, shadows, and limitations of vision, the accuracy of vacant parking slot detection for the park assist system (PAS) with a standalone around view monitor (AVM) needs to be improved. To address this problem, we propose a vacant parking slot detection method based on deep learning, namely VPS-Net. VPS-Net converts the vacant parking slot detection into a two-step problem, including parking slot detection and occupancy classification. In the parking slot detection stage, we propose a parking slot detection method based on YOLOv3, which combines the classification of the parking slot with the localization of marking points so that various parking slots can be directly inferred using geometric cues. In the occupancy classification stage, we design a customized network whose size of convolution kernel and number of layers are adjusted according to the characteristics of the parking slot. Experiments show that VPS-Net can detect various vacant parking slots with a precision rate of 99.63% and a recall rate of 99.31% in the ps2.0 dataset, and has a satisfying generalizability in the PSV dataset. By introducing a multi-object detection network and a classification network, VPS-Net can detect various vacant parking slots robustly.

7.
Acta Bioeng Biomech ; 22(3): 117-129, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33518731

RESUMO

PURPOSE: The purpose of the current study was to investigate whether an isolated human body lower limb FE model could predict leg kinematics and biomechanical response of a full body Chinese pedestrian model in vehicle collisions. METHODS: A human body lower limb FE model representing midsize Chinese adult male anthropometry was employed with different upper body weight attachments being evaluated by comparing the predictions to those of a full body pedestrian model in vehicle-to-pedestrian collisions considering different front-end shapes. RESULTS: The results indicate that upper body mass has a significant influence on pedestrian lower limb injury risk, the effect varies from vehicle front-end shape and is more remarkable to the femur and knee ligaments than to the tibia. In particular, the upper body mass can generally increase femur and knee ligaments injury risk, but has no obvious effect on the injury risk of tibia. The results also show that a higher attached buttock mass is needed for isolated pedestrian lower limb model for impacts with vehicles of higher bonnet leading edge. CONCLUSIONS: The findings of this study may suggest that it is necessary to consider vehicle shape variation in assessment of vehicle pedestrian protection performance and leg-form impactors with adaptive upper body mass should be used for vehicles with different front-end shapes, and the use of regional leg-form impactor modeling the local anthropometry to evaluate the actual lower limb injury of pedestrians in different countries and regions.


Assuntos
Acidentes de Trânsito , Povo Asiático , Corpo Humano , Perna (Membro)/fisiopatologia , Modelos Biológicos , Pedestres , Fenômenos Biomecânicos , Fêmur/fisiopatologia , Análise de Elementos Finitos , Humanos , Joelho/fisiopatologia , Traumatismos da Perna/fisiopatologia , Ligamentos/fisiopatologia , Tíbia/fisiopatologia
8.
Traffic Inj Prev ; 17(4): 430-3, 2016 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-26508539

RESUMO

OBJECTIVE: Crash test dummies are full-scale anthropomorphic test devices (ATDs) that simulate the dimensions, weight proportions, and articulation of the human body and are used to measure human injury potential in vehicle crashes. The Hybrid III dummy family, which is widely used currently, takes selected percentiles of anthropometry dimensions of U.S. adults as design references. The objective of this study was to assess the difference in anthropometry between Chinese adults and the currently used dummy. METHODS: Based on the Chinese National Physical Fitness Surveillance of the year 2000, 2005, 2010 and National Standard of China GB/T 10000-1988, a series of anthropometric parameters for Chinese adults were obtained, and data analysis was conducted between Chinese adults and ATDs that are currently used. RESULTS: The comparison revealed distinct anthropometric difference between ATDs and Chinese adults. Based on the latest data, median Chinese females were about 2.6% lower in stature and about 8.03% lower in body weight than the ATD design targets. Similarly, median Chinese males were about 3.48% shorter and weighed 11.89% less than the ATD design targets. CONCLUSIONS: Although the anthropometric differences between Chinese adults and the Hybrid III ATD specifications were modest and growing smaller, it is advisable to take the differences in anthropometry between ATDs and Chinese adults into consideration when developing new vehicles in China to provide effective protection specifically for Chinese occupants.


Assuntos
Antropometria , Povo Asiático , Manequins , Adulto , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA