Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
JACC Asia ; 3(2): 301-309, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37181397

RESUMO

Background: The distribution of radiation exposure on the body surface of interventional echocardiographers during structural heart disease (SHD) procedures is unclear. Objectives: This study estimated and visualized radiation exposure on the body surface of interventional echocardiographers performing transesophageal echocardiography by computer simulations and real-life measurements of radiation exposure during SHD procedures. Methods: A Monte Carlo simulation was performed to clarify the absorbed dose distribution of radiation on the body surface of interventional echocardiographers. The real-life radiation exposure was measured during 79 consecutive procedures (44 transcatheter edge-to-edge repairs of the mitral valve and 35 transcatheter aortic valve replacements [TAVRs]). Results: The simulation demonstrated high-dose exposure areas (>20 µGy/h) in the right half of the body, especially the waist and lower body, in all fluoroscopic directions caused by scattered radiation from the bottom edge of the patient bed. High-dose exposure occurred when obtaining posterior-anterior and cusp-overlap views. The real-life exposure measurements were consistent with the simulation estimates: interventional echocardiographers were more exposed to radiation at their waist in transcatheter edge-to-edge repair than in TAVR procedures (median 0.334 µSv/mGy vs 0.053 µSv/mGy; P < 0.001) and in TAVR with self-expanding valves than in those with balloon-expandable valves (median 0.067 µSv/mGy vs 0.039 µSv/mGy; P < 0.01) when the posterior-anterior or the right anterior oblique angle fluoroscopic directions were used. Conclusions: During SHD procedures, the right waist and lower body of interventional echocardiographers were exposed to high radiation doses. Exposure dose varied between different C-arm projections. Interventional echocardiographers, especially young women, should be educated regarding radiation exposure during these procedures. (The development of radiation protection shield for catheter-based treatment of structural heart disease [for echocardiologists and anesthesiologists]; UMIN000046478).

3.
J Radiat Res ; 64(2): 379-386, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36702614

RESUMO

Catheterization for structural heart disease (SHD) requires fluoroscopic guidance, which exposes health care professionals to radiation exposure risk. Nevertheless, existing freestanding radiation shields for anesthesiologists are typically simple, uncomfortable rectangles. Therefore, we devised a new perforated radiation shield that allows anesthesiologists and echocardiographers to access a patient through its apertures during SHD catheterization. No report of the relevant literature has described the degree to which the anesthesiologist's radiation dose can be reduced by installing radiation shields. For estimating whole-body doses to anesthesiologists and air dose distributions in the operating room, we used a Monte Carlo system for a rapid dose-estimation system used with interventional radiology. The simulations were performed under four conditions: no radiation shield, large apertures, small apertures and without apertures. With small apertures, the doses to the lens, waist and neck surfaces were found to be comparable to those of a protective plate without an aperture, indicating that our new radiation shield copes with radiation protection and work efficiency. To simulate the air-absorbed dose distribution, results indicated that a fan-shaped area of the dose rate decrease was generated in the area behind the shield, as seen from the tube sphere. For the aperture, radiation was found to wrap around the backside of the shield, even at a height that did not match the aperture height. The data presented herein are expected to be of interest to all anesthesiologists who might be involved in SHD catheterization. The data are also expected to enhance their understanding of radiation exposure protection.


Assuntos
Exposição à Radiação , Proteção Radiológica , Humanos , Anestesiologistas , Método de Monte Carlo , Proteção Radiológica/métodos , Imagens de Fantasmas , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA