Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 6199, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39043667

RESUMO

Nanoporous carbons with tailorable nanoscale texture and long-range ordered structure are promising candidates for energy, environmental and catalytic applications, while the current synthetic methods do not allow elaborate control of local structure. Here we report a salt-assisted strategy to obtain crystalline nanocarbon from direct carbonization of metal-organic frameworks (MOFs). The crystalline product maintains a highly ordered two-dimensional (2D) stacking mode and substantially differs from the traditional weakly ordered patterns of nanoporous carbons upon high-temperature pyrolysis. The MOF-derived crystalline nanocarbon (MCC) comes with a high level of nitrogen and oxygen terminating the 2D layers and shows an impressive performance as a carbocatalyst in Fenton-like reaction for water purification. The successful preparation of MCC illustrates the possibility to discover other crystalline heteroatom-doped carbon phases starting from correctly designed organic precursors and appropriate templating reactions.

2.
Rev Esp Enferm Dig ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38832596

RESUMO

The inverted hyperplastic polyp (IHP) is known as hyperplastic gastric mucosa growth into submucosa and endoscopically presented as sessile or pedunculated submucosa lesion. It occurs in between 3.1% to 20.1% of cases, while its malignant transformation rate is just 0.02%. A male underwent esophagogastroduodenoscopy (EGD) and discovered a submucosal lesion with a pinhole-like orifice in the fundus. And endoscopic ultrasound (EUS) showed it was a heterogenous hypoechoic lesion located in the submucosa. After endoscopic resection, the pathological findings and immunohistochemical staining revealed it was inverted hyperplastic polyp (IHP) with adenocarcinoma. The measurement of the cancerous IHP depth of invasion is controversial. Thus, how to define the depth of lesion invasion in this patient needs to be seriously considered. To manage IHP with adenocarcinoma better, the depth of lesion invasion cancerous IHP needs to be seriously considered.

4.
Angew Chem Int Ed Engl ; 63(21): e202400230, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38520070

RESUMO

Hydrogels hold great promise as electrolytes for emerging aqueous batteries, for which establishing a robust electrode-hydrogel interface is crucial for mitigating side reactions. Conventional hydrogel electrolytes fabricated by ex situ polymerization through either thermal stimulation or photo exposure cannot ensure complete interfacial contact with electrodes. Herein, we introduce an in situ electropolymerization approach for constructing hydrogel electrolytes. The hydrogel is spontaneously generated during the initial cycling of the battery, eliminating the need of additional initiators for polymerization. The involvement of electrodes during the hydrogel synthesis yields well-bonded and deep infiltrated electrode-electrolyte interfaces. As a case study, we attest that, the in situ-formed polyanionic hydrogel in Zn-MnO2 battery substantially improves the stability and kinetics of both Zn anode and porous MnO2 cathode owing to the robust interfaces. This research provides insight to the function of hydrogel electrolyte interfaces and constitutes a critical advancement in designing highly durable aqueous batteries.

5.
Adv Mater ; 36(21): e2313610, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38348791

RESUMO

Zinc-iodine batteries have the potential to offer high energy-density aqueous energy storage, but their lifetime is limited by the rampant dendrite growth and the concurrent parasite side reactions on the Zn anode, as well as the shuttling of polyiodides. Herein, a cation-conduction dominated hydrogel electrolyte is designed to holistically enhance the stability of both zinc anode and iodine cathode. In this hydrogel electrolyte, anions are covalently anchored on hydrogel chains, and the major mobile ions in the electrolyte are restricted to be Zn2+. Specifically, such a cation-conductive electrolyte results in a high zinc ion transference number (0.81) within the hydrogel and guides epitaxial Zn nucleation. Furthermore, the optimized Zn2+ solvation structure and the reconstructed hydrogen bond networks on hydrogel chains contribute to the reduced desolvation barrier and suppressed corrosion side reactions. On the iodine cathode side, the electrostatic repulsion between negative sulfonate groups and polyiodides hinders the loss of the iodine active material. This all-round electrolyte design renders zinc-iodine batteries with high reversibility, low self-discharge, and long lifespan.

6.
Dig Dis Sci ; 69(4): 1411-1420, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38418684

RESUMO

BACKGROUND AND AIMS: The impact of submucosal injection during cold snare polypectomy (CSP) remains uncertain. We conducted an evidence-based comparison of conventional CSP (C-CSP) and CSP with submucosal injection (SI-CSP) for colorectal polyp resection. METHODS: PubMed, Embase, and the Cochrane Library databases were searched for randomized controlled trials (RCTs) comparing C-CSP with SI-CSP. Major outcomes included the rates of complete resection, en bloc resection, polyp retrieval, and adverse events, as well as the duration of polypectomy. Data were analyzed by using a random-effects model. RESULTS: A total of seven RCTs were included. Complete resection rates for all polyps (RR 0.98; 95% CI 0.93-1.03), polyps ≤ 10 mm (RR 0.99; 95% CI 0.96-1.02) and polyps > 10 mm (RR 0.92; 95% CI 0.69-1.12) were not substantially different between C-CSP and SI-CSP groups. En bloc resection rate (RR 0.93; 95% CI 0.79-1.09) and polyp retrieval rate (RR 1.00; 95% CI 0.99-1.01) were also not significantly different between the two groups. The SI-CSP group required a prolonged polypectomy time than the C-CSP group (SMD - 0.89; 95% CI -1.29 to -0.49). Adverse events were rare in both groups. CONCLUSIONS: SI-CSP is not an optimal substitute for CSP in the resection of colorectal polyps, particularly diminutive and small polyps.


Assuntos
Pólipos do Colo , Colonoscopia , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/métodos , Mucosa Intestinal/cirurgia , Mucosa Intestinal/patologia , Resultado do Tratamento , Injeções , Ressecção Endoscópica de Mucosa/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos
7.
Small Methods ; 8(8): e2301316, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38161269

RESUMO

Due to their high energy density and cost-effectiveness, lithium-sulfur batteries (LSBs) are considered highly promising for the next generation of energy storage technologies. However, the soluble lithium-polysulfides (LiPSs) notorious for causing the shuttle effect and the sluggish redox kinetics have hindered their practical commercialization. To tackle these challenges, a heterostructural catalyst featuring NiS-NiCo2O4 interfaces is developed, which serves as an interlayer for LSBs. These interfacial sites leverage the advantages of polar NiCo2O4 and conductive NiS, enabling smooth Li+ diffusion, rapid electron transport, and effective immobilization of LiPSs. This synergistic approach promotes the conversion of sulfur species, resulting in a high discharge capacity of 526 mAh g-1 at 3 C for cells with the NiS-NiCo2O4 interlayer. Additionally, remarkable cycling stability is achievable with an areal sulfur loading of ≈5.0 mg cm-2. It is believed that this research paves the way for practical applications of LSBs.

8.
Angew Chem Int Ed Engl ; 63(8): e202318470, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38179860

RESUMO

The practical implementation of aqueous zinc-iodine batteries (ZIBs) is hindered by the rampant Zn dendrites growth, parasite corrosion, and polyiodide shuttling. In this work, ionic liquid EMIM[OAc] is employed as an all-round solution to mitigate challenges on both the Zn anode and the iodine cathode side. First, the EMIM+ embedded lean-water inner Helmholtz plane (IHP) and inert solvation sheath modulated by OAc- effectively repels H2 O molecules away from the Zn anode surface. The preferential adsorption of EMIM+ on Zn metal facilitates uniform Zn nucleation via a steric hindrance effect. Second, EMIM+ can reduce the polyiodide shuttling by hindering the iodine dissolution and forming an EMIM+ -I3 - dominated phase. These effects holistically enhance the cycle life, which is manifested by both Zn || Zn symmetric cells and Zn-I2 full cells. ZIBs with EAc deliver a capacity decay rate of merely 0.01 ‰ per cycle after over 18,000 cycles at 4 A g-1 , and lower self-discharge and better calendar life than the ZIBs without ionic liquid EAc additive.

10.
World J Gastroenterol ; 29(47): 6138-6147, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38186680

RESUMO

BACKGROUND: Superficial esophageal squamous cell carcinoma (ESCC) is defined as cancer infiltrating the mucosa and submucosa, regardless of regional lymph node metastasis (LNM). Endoscopic resection of superficial ESCC is suitable for lesions that have no or low risk of LNM. Patients with a high risk of LNM always need further treatment after endoscopic resection. Therefore, accurately assessing the risk of LNM is critical for additional treatment options. AIM: To analyze risk factors for LNM and develop a nomogram to predict LNM risk in superficial ESCC patients. METHODS: Clinical and pathological data of superficial ESCC patients undergoing esophagectomy from January 1, 2009 to January 31, 2016 were collected. Logistic regression analysis was used to predict LNM risk factors, and a nomogram was developed based on risk factors derived from multivariate logistic regression analysis. The receiver operating characteristic (ROC) curve was used to obtain the accuracy of the nomogram model. RESULTS: A total of 4660 patients with esophageal cancer underwent esophagectomy. Of these, 474 superficial ESCC patients were enrolled in the final analysis, with 322 patients in the training set and 142 patients in the validation set. The prevalence of LNM was 3.29% (5/152) for intramucosal cancer and increased to 26.40% (85/322) for submucosal cancer. Multivariate logistic analysis showed that tumor size, invasive depth, tumor differentiation, infiltrative growth pattern, tumor budding, and lymphovascular invasion were significantly correlated with LNM. A nomogram using these six variables showed good discrimination with an area under the ROC curve of 0.789 (95%CI: 0.737-0.841) in the training set and 0.827 (95%CI: 0.755-0.899) in the validation set. CONCLUSION: We developed a useful nomogram model to predict LNM risk for superficial ESCC patients which will facilitate additional decision-making in treating patients who undergo endoscopic resection.


Assuntos
Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Humanos , Carcinoma de Células Escamosas do Esôfago/cirurgia , Neoplasias Esofágicas/cirurgia , Metástase Linfática , Nomogramas , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA