Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
bioRxiv ; 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39229222

RESUMO

Electrophysiological recordings of neurons in deep brain regions using optogenetic stimulation are essential to understanding and regulating the role of complex neural activity in biological behavior and cognitive function. Optogenetic techniques have significantly advanced neuroscience research by enabling the optical manipulation of neural activities. Because of the significance of the technique, constant advancements in implantable optrodes that integrate optical stimulation with low-noise, large-scale electrophysiological recording are in demand to improve the spatiotemporal resolution for various experimental designs and future clinical applications. However, robust and easy-to-use neural optrodes that integrate neural recording arrays with high-intensity light emitting diodes (LEDs) are still lacking. Here, we propose a neural optrode based on Gallium Nitride (GaN) on sapphire technology, which integrates a high-intensity blue LED with a 5x2 recording array monolithically for simultaneous neural recording and optogenetic manipulation. To reduce the noise interference between the recording electrodes and the LED, which is in close physical proximity, three metal grounding interlayers were incorporated within the optrode, and their ability to reduce LED-induced artifacts during neural recording was confirmed through both electromagnetic simulations and experimental demonstrations. The capability of the sapphire optrode to record action potentials has been demonstrated by recording the firing of mitral/tuft cells in the olfactory bulbs of mice in vivo. Additionally, the elevation of action potential firing due to optogenetic stimulation observed using the sapphire probe in medial superior olive (MSO) neurons of the gerbil auditory brainstem confirms the capability of this sapphire optrode to precisely access neural activities in deep brain regions under complex experimental designs.

2.
Micromachines (Basel) ; 15(8)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39203610

RESUMO

GaN Schottky diodes show great potential in high-power terahertz frequency multipliers. The thermal characteristics of GaN Schottky diodes with single and double-row anode arrangements are described in this paper. The temperature distribution inside the Schottky diode is discussed in detail under the coupling condition of Joule heat and solid heat transfer. The effects of different substrates and substrate geometric parameters on the thermal characteristics of the Schottky diode chips with single and double-row anode arrangements are systematically analyzed. Compared with that of the chip with single-row anode arrangement, the maximum temperature of the chip with double-row anode arrangement can be reduced by 40 K at the same conditions. For chips with different substrates, chips with diamond substrates can withstand greater power dissipation when reaching the same temperature. The simulation results are instructive for the design and optimization of Schottky diodes in the terahertz field.

3.
ACS Omega ; 9(30): 33119-33129, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39100334

RESUMO

Optogenetics-based integrated photoelectrodes with high spatiotemporal resolution play an important role in studying complex neural activities. However, the photostimulation artifacts caused by the high level of integration and the high impedance of metal recording electrodes still hinder the application of photoelectrodes for optogenetic studies of neural circuits. In this study, a neural optrode fabricated on sapphire GaN material was proposed, and 4 µLEDs and 14 recording microelectrodes were monolithically integrated on a shank. Poly(3,4-ethylenedioxythiophene)/polystyrenesulfonate and multiwalled carbon nanotubes (PEDOT:PSS-MWCNT) and poly(3,4-ethylenedioxythiophene) and graphene oxide (PEDOT-GO) composite films were deposited on the surface of the recording microelectrode by electrochemical deposition. The results demonstrate that compared with the gold microelectrode, the impedances of both composite films reduced by more than 98%, and the noise amplitudes decreased by 70.73 and 87.15%, respectively, when exposed to light stimulation. Adjusting the high and low levels, we further reduced the noise amplitude by 48.3%. These results indicate that modifying the electrode surface by a polymer composite film can effectively enhance the performance of the microelectrode and further promote the application of the optrode in the field of neuroscience.

4.
Front Chem ; 10: 810837, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35155366

RESUMO

Lung cancer is a fatal tumor threatening human health. It is of great significance to explore a diagnostic method with wide application range, high specificity, and high sensitivity for the detection of lung cancer. In this study, data fusion and wavelet transform were used in combination with Fourier transform infrared (FTIR) spectroscopy and Raman spectroscopy to study the serum samples of patients with lung cancer and healthy people. The Raman spectra of serum samples can provide more biological information than the FTIR spectra of serum samples. After selecting the optimal wavelet parameters for wavelet threshold denoising (WTD) of spectral data, the partial least squares-discriminant analysis (PLS-DA) model showed 93.41% accuracy, 96.08% specificity, and 90% sensitivity for the fusion data processed by WTD in the prediction set. The results showed that the combination of FTIR spectroscopy and Raman spectroscopy based on data fusion and wavelet transform can effectively diagnose patients with lung cancer, and it is expected to be applied to clinical screening and diagnosis in the future.

5.
Front Oncol ; 11: 753791, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34660320

RESUMO

Lung cancer is the leading cause of cancer-related death in the world. Early diagnosis has great significance for the survival of patients with lung cancer. In this paper, attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy combined with chemometrics was used to study the serum samples from patients with lung cancer and healthy people. The results of spectral band area comparison showed that the concentrations of protein, lipid and nucleic acids molecules in serum of patients with lung cancer were increased compared with those in healthy people. The original spectra were preprocessed to improve the accuracy of principal component regression (PCR) and partial least squares-discriminant analysis (PLS-DA) models. PLS-DA results for first derivative spectral data in nucleic acids (1250-1000cm-1) band showed 80% sensitivity, 91.89% specificity and 87.10% accuracy with high R c 2 of 0.8949 and R v 2 of 0.8153, low RMSEC of 0.3136 and RMSEV of 0.4180. It is shown that ATR-FTIR spectroscopy combined with chemometrics might be developed as a simple method for clinical screening and diagnosis of lung cancer.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 263: 120181, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34311164

RESUMO

Liver cancer is the most common fatal malignant tumor in the world. Early diagnosis of liver cancer can improve the survival rate of the patients with liver disease. In this paper, Fourier transform infrared (FTIR) spectroscopy combined with curve fitting and chemometrics was used to distinguish the serum from patients from that of healthy people. The curve fitting results in protein range of 1700-1600 cm-1 showed that there were differences in the secondary structure of protein in serum between the patients with liver cancer and healthy people. Principal component analysis (PCA) in lipid range of 2900-2800 cm-1 could distinguish the serum of patients with liver cancer from that of healthy people. The first two principal components PC1 and PC2 explained 95% of the total data variance. The sensitivity and specificity of partial least squares discriminant analysis (PLS-DA) in lipid range of 2900-2800 cm-1 reached 92.85% and 95.23% respectively. It is shown that FTIR spectroscopy might be developed as an effective method for the diagnosis of liver cancer.


Assuntos
Neoplasias Hepáticas , Análise Discriminante , Análise de Fourier , Humanos , Análise dos Mínimos Quadrados , Neoplasias Hepáticas/diagnóstico , Análise de Componente Principal , Espectroscopia de Infravermelho com Transformada de Fourier
7.
Nan Fang Yi Ke Da Xue Xue Bao ; 26(6): 760-3, 2006 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-16793594

RESUMO

OBJECTIVE: To investigate the effects of motilin agonists on intracellular Ca(2+) mobilization in primary cultured rat myenteric neurons. METHODS: Motilin-induced and erythromycin-induced intracellular Ca(2+) signaling was studied in primary cultures of rat myenteric neurons using the radiometric Ca(2+) indicator Furo3/AM with a laser confocal microscope. RESULTS: In Hank's solution, 10(-8), 10(-7), and 10(-6) mol/L motilin could elevate intracellular Ca(2+) concentration ([Ca(2+)]i) to the peak levels of 10.6-/+2.1, 15.9-/+1.2, and 30.6-/+3.7 respectively with their relative percentage change in fluorescent intensity of (40.1-/+6.3)%, (63.0-/+11.2)%, and (100.8-/+18.4)% respectively, indicating the dose-dependent effect of motilin on [Ca(2+)]i. In Hank's solution, 10 microg/ml erythromycin could induce the elevation of [Ca(2+)]i to the average peak of 23.2-/+5.6 with the relative percentage change in fluorescent intensity of (82.8-/+13.0)%. When pretreated with the antibody against motilin receptor in Hank's solution, the effect of 10 microg/ml erythromycin was almost inhibited completely. CONCLUSION: Motilin can increase [Ca(2+)]i, and erythromycin also has this effect by binding to motilin receptor.


Assuntos
Cálcio/metabolismo , Eritromicina/farmacologia , Motilina/farmacologia , Neurônios/efeitos dos fármacos , Receptores dos Hormônios Gastrointestinais/agonistas , Receptores de Neuropeptídeos/agonistas , Animais , Animais Recém-Nascidos , Sinalização do Cálcio/efeitos dos fármacos , Células Cultivadas , Relação Dose-Resposta a Droga , Microscopia Confocal , Plexo Mientérico/citologia , Plexo Mientérico/metabolismo , Neurônios/citologia , Neurônios/metabolismo , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA