1.
Technol Cancer Res Treat ; 11(3): 249-55, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22417057

RESUMO

We aimed to compare dosimetric characteristics of conventional linear accerator-based treatment plans to those created using the robotic CyberKnife® (CK) treatment planning system for patients with early-stage lung cancer. Eight early-stage lung cancer patients treated with stereotactic body radiotherapy (SBRT) using a conventional linac-based (LIN) system were included in this study. New treatment plans were created for the patients with the CK treatment planning system in order to compare the two platforms' dosimetric characteristics. Planning computed tomographies (CT) were obtained in three phases: free-breathing, full exhalation and inhalation. The three GTVs were then added together for internal target volume (ITV) with LIN, whereas no ITV was used for CK. Planning target volumes (PTV) were constituted by adding 5-mm margin to GTV and ITV. Treatment plan was 54 Gy in three fractions. Five-field, seven-field, and dynamic-conformal arc planning techniques were used in LIN plans. Plans were compared according to dose heterogenity (D(max)-maximum dose), volume of 54 Gy (V54) and 27 Gy isodose (V27), conformity index (CI(54) and CI(27)) and lung volumes. PTVs were significantly smaller in CK plans (p=0.012). D(max) was significantly lower in ARC plans (p=0.01). Among all plans, CK had significantly tightest isodose shell received 54 Gy and 27 Gy (p=0.0001). Among LIN plans, V54 was significantly (p=0.03) smaller in ARC plans; but no difference was observed for V27 values. LIN plans have better plan quality (CI(27) and CI(54)) than CK. No statistically significant difference was observed for lung volumes. CK plans had superior V54 and V27 values compared to LIN plans due to smaller PTV. LIN plans had better CI(27) and CI(54) values. Advantages of LIN treatment were no neccessity for fiducial marker use, which may cause pneumothorax, and significantly shorter beam-on treatment times. Both CK and LIN methods are suitable for lung SBRT.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Robótica/métodos , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Aceleradores de Partículas , Radioterapia de Intensidade Modulada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA