Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Acta Oncol ; 61(2): 223-230, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34632922

RESUMO

BACKGROUND: The Danish Breast Cancer Group (DBCG) Proton Trial randomizes breast cancer patients selected on high mean heart dose (MHD) or high lung dose (V20Gy/V17Gy) in the photon plan between photon and proton therapy. This study presents the proton plans and adaptation strategy for the first 43 breast cancer patients treated with protons in Denmark. MATERIAL AND METHODS: Forty-four proton plans (one patient with bilateral cancer) were included; 2 local and 42 loco-regional including internal mammary nodes (IMN). Nineteen patients had a mastectomy and 25 a lumpectomy. The prescribed dose was either 50 Gy in 25 fractions (n = 30) or 40 Gy in 15 fractions (n = 14) wherefrom five received simultaneous integrated boost to the tumor bed. Using 2-3 en face proton fields, single-field optimization, robust optimization and a 5 cm range shifter ensured robustness towards breathing motion, setup- and range uncertainties. An anatomical evaluation was performed by evaluating the dose after adding/removing 3 mm and 5 mm tissue to/from the body-outline and used to define treatment tolerances for anatomical changes. RESULTS: The nominal and robust criteria were met for all patients except two. The median MHD was 1.5 Gy (0.5-3.4 Gy, 50 Gy) and 1.1 Gy (0.0-1.5 Gy, 40 Gy). The anatomical evaluations showed how 5 mm shrinkage approximately doubled the MHD while 5 mm swelling reduced target coverage of the IMN below constraints. Ensuring 3-5 mm robustness toward swelling was prioritized but not always achieved by robust optimization alone emphasizing the need for a distal margin. Twenty-eight patients received plan adaptation, eight patients received two, and one received five. CONCLUSION: This proton planning strategy ensured robust treatment plans within a pre-defined level of acceptable anatomical changes that fulfilled the planning criteria for most of the patients and ensured low MHD.


Assuntos
Neoplasias da Mama , Terapia com Prótons , Radioterapia de Intensidade Modulada , Neoplasias da Mama/radioterapia , Feminino , Humanos , Mastectomia , Órgãos em Risco , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
2.
Clin Transl Radiat Oncol ; 27: 126-131, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33659716

RESUMO

BACKGROUND AND PURPOSE: Adjuvant radiotherapy of internal mammary nodes (IMN) improves survival in high-risk early breast cancer patients but inevitably leads to more dose to heart and lung. Target coverage is often compromised to meet heart/lung dose constraints. We estimate heart and lung dose when target coverage is not compromised in consecutive patients. These estimates are used to guide the choice of selection criteria for the randomised Danish Breast Cancer Group (DBCG) Proton Trial. MATERIALS AND METHODS: 179 breast cancer patients already treated with loco-regional IMN radiotherapy from 18 European departments were included. If the clinically delivered treatment plan did not comply with defined target coverage requirements, the plan was modified retrospectively until sufficient coverage was reached. The choice of selection criteria was based on the estimated number of eligible patients for different heart and lung dose thresholds in combination with proton therapy capacity limitations and dose-response relationships for heart and lung. RESULTS: Median mean heart dose was 3.0 Gy (range, 1.1-8.2 Gy) for left-sided and 1.4 Gy (0.4-11.5 Gy) for right-sided treatment plans. Median V17Gy/V20Gy (hypofractionated/normofractionated plans) for ipsilateral lung was 31% (9-57%). The DBCG Radiotherapy Committee chose mean heart dose ≥ 4 Gy and/or lung V17Gy/V20Gy ≥ 37% as thresholds for inclusion in the randomised trial. Using these thresholds, we estimate that 22% of patients requiring loco-regional IMN radiotherapy will be eligible for the trial. CONCLUSION: The patient selection criteria for the DBCG Proton Trial are mean heart dose ≥ 4 Gy and/or lung V17Gy/V20Gy ≥ 37%.

3.
Radiother Oncol ; 150: 121-127, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32544606

RESUMO

BACKGROUND AND PURPOSE: This study presents Danish consensus guidelines for delineation of the heart and cardiac substructures across relevant Danish Multidisciplinary Cancer Groups. MATERIAL AND METHODS: Consensus guidelines for the heart and cardiac substructures were reached among 15 observers representing the radiotherapy (RT) committees of four Danish Multidisciplinary Cancer Groups. The guidelines were validated on CT scans of 12 patients, each with five independent contour sets. The Sørensen-Dice similarity coefficient (DSC), the distance between the centers of the arteries and the mean surface distance were used to evaluate the inter-observer variation. RESULTS: National guidelines for contouring the heart and cardiac substructures were achieved. The median DSC was 0.78-0.96 for the heart and the four cardiac chambers. For the four substructures of the left ventricle, the median DSC was 0.35-0.57. The coronary arteries were contoured in ten segments, with the best agreement for the left anterior descending coronary artery segments, with a median distance between the arteries ranging from 2.4-4.4 mm. The median variation was 3.7-12.8 mm for the right coronary artery segments and 3.7-6.2 mm for the left circumflex coronary artery segments, with the most pronounced inter-observer variation in the distal segment for all three coronary arteries. CONCLUSION: National guidelines for contouring the heart and cardiac substructures were developed across relevant Danish Multidisciplinary Cancer Groups, where RT dose to the heart is of concern. The inter-observer contour overlap was best for the heart and chambers and decreased for smaller structures.


Assuntos
Neoplasias , Planejamento da Radioterapia Assistida por Computador , Dinamarca , Coração/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Tórax
4.
Acta Oncol ; 57(1): 107-112, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29202666

RESUMO

INTRODUCTION: The current study evaluates the data quality achievable using a national data bank for reporting radiotherapy parameters relative to the classical manual reporting method of selected parameters. METHODS: The data comparison is based on 1522 Danish patients of the DBCG hypo trial with data stored in the Danish national radiotherapy data bank. In line with standard DBCG trial practice selected parameters were also reported manually to the DBCG database. Categorical variables are compared using contingency tables, and comparison of continuous parameters is presented in scatter plots. RESULTS: For categorical variables 25 differences between the data bank and manual values were located. Of these 23 were related to mistakes in the manual reported value whilst the remaining two were a wrong classification in the data bank. The wrong classification in the data bank was related to lack of dose information, since the two patients had been treated with an electron boost based on a manual calculation, thus data was not exported to the data bank, and this was not detected prior to comparison with the manual data. For a few database fields in the manual data an ambiguity of the parameter definition of the specific field is seen in the data. This was not the case for the data bank, which extract all data consistently. CONCLUSIONS: In terms of data quality the data bank is superior to manually reported values. However, there is a need to allocate resources for checking the validity of the available data as well as ensuring that all relevant data is present. The data bank contains more detailed information, and thus facilitates research related to the actual dose distribution in the patients.


Assuntos
Neoplasias da Mama/radioterapia , Bases de Dados Factuais , Controle de Qualidade , Dinamarca , Fracionamento da Dose de Radiação , Feminino , Humanos , Radioterapia Adjuvante , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA