Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Microbiol Spectr ; 11(3): e0314822, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37071009

RESUMO

Population-based HIV Impact Assessments (PHIAs) are national household (HH) surveys that provide HIV diagnosis and CD4 testing with an immediate return of results. Accurate CD4 results improve HIV-positive participants' clinical care and inform the effectiveness of HIV programs. Here, we present CD4 results from the PHIA surveys that were conducted in 11 countries in sub-Saharan Africa between 2015 and 2018. All of the HIV-positive participants and 2 to 5% of the HIV-negative participants were offered Pima CD4 (Abbott, IL, USA) point-of-care (POC) tests. The quality of the CD4 test was ensured by conducting instrument verification, comprehensive training, quality control, a review of testing errors and an analysis of unweighted CD4 data by HIV status, age, gender, and antiretroviral (ARV) treatment status. Overall, CD4 testing was completed for 23,085 (99.5%) of the 23,209 HIV-positive and 7,329 (2.7%) of the 270,741 negative participants in 11 surveys. The instrument error rate was 11.3% (range, 4.4% to 15.7%). The median CD4 values among HIV-positive and HIV-negative participants (aged 15+) were 468 cells/mm3 (interquartile range [IQR], 307 to 654) and 811 cells/mm3 (IQR, 647 to 1,013), respectively. Among the HIV-positive participants (aged 15+), those with detectable ARVs had higher CD4 values (508 cells/mm3) than those with undetectable ARVs (385.5 cells/mm3). Among the HIV-positive participants (aged 15+), 11.4% (2,528/22,253) had a CD4 value of less than 200 cells/mm3, and approximately half of them (1,225/2,528 = 48.5%) had detectable ARVs, whereas 51.5% (1,303/2,528) had no detectable ARVs (P < 0.0001). We successfully implemented high quality POC CD4 testing using Pima instruments. Our data come from nationally representative surveys in 11 countries and provide unique insights regarding the CD4 distribution among HIV-positive individuals as well as the baseline CD4 values among HIV-negative individuals. IMPORTANCE The manuscript describes CD4 levels among HIV-positive individuals and baseline CD4 levels among HIV-negative individuals from 11 sub-Saharan countries, thereby highlighting the importance of CD4 markers in the context of the HIV epidemic. Despite increased ARV access in each country, advanced HIV disease (CD4 < 200 cells/mm3) persists among approximately 11% of HIV-positive individuals. Therefore, it is important that our findings are shared with the scientific community to assist with similar implementations of point-of-care testing and to conduct a review of HIV programmatic gaps.


Assuntos
Infecções por HIV , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Antirretrovirais/uso terapêutico , Contagem de Linfócito CD4 , HIV , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Testes Imediatos , Indicadores de Qualidade em Assistência à Saúde
2.
PLOS Glob Public Health ; 2(7): e0000466, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36962526

RESUMO

BACKGROUND: The Nigeria AIDS Indicator and Impact Survey (NAIIS), a cross-sectional household survey, was conducted in 2018 with primary objectives to estimate HIV prevalence, HIV-1 incidence, and status of UNAIDS 90-90-90 cascade. We conducted retrospective analysis of the performance of HIV rapid tests and the national HIV testing algorithm used in Nigeria. METHODS: The national algorithm included Determine HIV-1/2 as test 1 (T1), Unigold HIV-1/2 as test 2 (T2), and StatPak HIV-1/2 as the tie-breaker test (T3). Individuals reactive with T1 and either T2 or T3 were considered HIV-positive. HIV-positive specimens from the algorithm were further confirmed for the survey using supplemental test Geenius HIV-1/2. If Geenius did not confirm HIV-positive status, HIV-1 Western blot was performed. We calculated the concordance between tests and positive predictive value (PPV) of the algorithm on unweighted data. RESULTS: Of 204,930 participants (ages ≥18 months) 5,103 (2.5%) were reactive on T1. Serial testing of T1 reactive specimens with T2 or if needed by tiebreaker T3 identified 2958 (1.44%) persons as HIV-positive. Supplemental testing confirmed 2,800 (95%) as HIV-positive (HIV-1 = 2,767 [98.8%]; HIV-2 = 5 [0.2%]; dual infections = 22 [0.8%]). Concordance between T1 and T2 was 56.6% while PPV of the national algorithm was 94.5%. CONCLUSIONS: Our results show high discordant rates and poor PPV of the national algorithm with a false-positive rate of about 5.5% in the NAIIS survey. Considering our findings have major implications for HIV diagnosis in routine HIV testing services, additional evaluation of testing algorithm is warranted in Nigeria.

3.
J Acquir Immune Defic Syndr ; 87(Suppl 1): S17-S27, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34166309

RESUMO

BACKGROUND: Conducting HIV surveys in resource-limited settings is challenging because of logistics, limited availability of trained personnel, and complexity of testing. We described the procedures and systems deemed critical to ensure high-quality laboratory data in the population-based HIV impact assessments and large-scale household surveys. METHODS: Laboratory professionals were engaged in every stage of the surveys, including protocol development, site assessments, procurement, training, quality assurance, monitoring, analysis, and reporting writing. A tiered network of household, satellite laboratories, and central laboratories, accompanied with trainings, optimized process for blood specimen collection, storage, transport, and real-time monitoring of specimen quality, and test results at each level proved critical in maintaining specimen integrity and high-quality testing. A plausibility review of aggregate merged data was conducted to confirm associations between key variables as a final quality check for quality of laboratory results. RESULTS: Overall, we conducted a hands-on training for 3355 survey staff across 13 surveys, with 160-387 personnel trained per survey on biomarker processes. Extensive training and monitoring demonstrated that overall, 99% of specimens had adequate volume and 99.8% had no hemolysis, indicating high quality. We implemented quality control and proficiency testing for testing, resolved discrepancies, verified >300 Pima CD4 instruments, and monitored user errors. Aggregate data review for plausibility further confirmed the high quality of testing. CONCLUSIONS: Ongoing engagement of laboratory personnel to oversee processes at all levels of the surveys is critical for successful national surveys. High-quality population-based HIV impact assessments laboratory data ensured reliable results and demonstrated the impact of HIV programs in 13 countries.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , HIV-1 , Ensaio de Proficiência Laboratorial/normas , Países em Desenvolvimento , Monitoramento Epidemiológico , Inquéritos Epidemiológicos , Humanos , Pessoal de Laboratório/educação , Pessoal de Laboratório/normas , Controle de Qualidade
4.
J Clin Virol ; 37(3): 199-205, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16973409

RESUMO

BACKGROUND: Quantification of HIV-1 RNA remains difficult to implement in Africa. Simple and inexpensive tests for antiretroviral treatment (ART) monitoring are needed. OBJECTIVE: To evaluate an HIV-1 p24 ELISA, which combines efficient virus disruption, heat-denaturation and signal amplification, in a West African setting. STUDY DESIGN: Eighty-six HIV-1 infected patients from Abidjan, Côte d'Ivoire, were tested for p24, HIV-1 RNA, and CD4+ count at baseline, and twice within 8 months after ART initiation. RESULTS: All patients responded to ART with a minimal HIV-1 RNA drop of 0.5 log(10) at first follow-up. Forty-one (47.7%) then rebounded >0.5 log(10) or persisted above 1000 copies/mL by week 24. The predicted baseline concentration of p24 corresponding to 100,000 copies/mL of HIV-1 RNA, above which ART is recommended, was 4546 fg/mL (95% confidence interval 3148-6566). A prediction model of virologic failure, occurring after an initial response to ART, correctly classified 84% of patients using baseline p24, p24 change on therapy, and achievement of undetectable p24 as explanatory variables. The model and further bootstrap evaluation suggested a good ability to discriminate between sustained or failing virologic response to ART. CONCLUSION: HIV-1 p24 and RNA based-ART monitoring in a low-resource country dominated by HIV-1 CRF02 AG appeared comparable.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/virologia , HIV-1/genética , RNA Viral/sangue , Antirretrovirais/uso terapêutico , Linfócitos T CD4-Positivos/virologia , Côte d'Ivoire , Feminino , Proteína do Núcleo p24 do HIV/imunologia , Infecções por HIV/sangue , Infecções por HIV/tratamento farmacológico , Humanos , Masculino , Valor Preditivo dos Testes , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA