Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 20(1): 366, 2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32943044

RESUMO

BACKGROUND: Post-implantation visual outcomes in patients with the Argus II Retinal Prosthesis is dependent on a multitude of factors including the positioning of the electrode array on the retina. The purpose of this study is to determine whether the average electrode array-retina gap distance correlates with objective visual function outcomes and sensitivity detection thresholds in patients implanted with the Argus II Retinal Prosthesis. METHODS: Five patients with implantation of the Argus II Retinal Prosthesis were enrolled in this single-institution retrospective study. Patient demographics were collected from medical records. Visual function data (Square Localization [SL] and Direction of Motion [DOM]) and Optical Coherence Tomography (Cirrus HD-OCT) images were extracted retrospectively from the Argus II Retinal Prosthesis Post-Approval study. Visual function tests were performed with the device OFF and ON at each study visit. Electrode array-retina gap distances were measured at each of the array's 60 electrodes using the Cirrus HD-OCT software in both the nasotemporal and superoinferior planes. Data was obtained at baseline, and post-operative month 1, month 3, month 6, and year 1. Sensitivity detection thresholds were obtained at the initial programming visit and each reprogramming session. RESULTS: Three patients performed significantly better in SL visual function testing with the device ON. Patients that worsened in visual function testing with the device ON in both SL and DOM testing had a statistically significant decrease in performance. The electrode array-retina gap distance was found to effect performance in SL testing in a patient-dependent manner. No effect was found between the electrode-array gap distance and DOM testing or sensitivity detection threshold. CONCLUSION: Our results demonstrate that the electrode array-retina gap distance may affect visual function outcomes in SL testing in certain patients with the Argus II Retinal Prosthesis, and the direction and magnitude of this effect is likely patient-dependent. Furthermore, complete apposition between the electrode array and retina may not always be necessary to achieve optimal visual outcomes.


Assuntos
Retinose Pigmentar , Próteses Visuais , Eletrodos Implantados , Humanos , Implantação de Prótese , Retina/diagnóstico por imagem , Retina/cirurgia , Retinose Pigmentar/cirurgia , Estudos Retrospectivos
2.
Ophthalmology ; 126(6): 856-865, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30278196

RESUMO

PURPOSE: To investigate the natural history of dark adaptation (DA) function as measured by the change in rod intercept time (RIT) over 4 years and to correlate RIT change with age-related macular degeneration (AMD) severity. DESIGN: Longitudinal, single-center, observational study. PARTICIPANTS: A total of 77 participants aged ≥50 years with a range of AMD severities. METHODS: Participants each contributing a single study eye to the analysis were assigned into person-based AMD severity groups based on fundus characteristics (drusen, pigmentary changes, late AMD, and subretinal drusenoid deposits [SDDs]). The DA function was assessed in study eyes at baseline and 3, 6, 12, 18, 24, 36, and 48 months. Mean change in DA function over time was calculated using the slope of linear regression fits of longitudinal RIT data. Patient-reported responses on a Low Luminance Questionnaire (LLQ) were obtained at baseline and yearly. Nonparametric statistical testing was performed on all comparisons. MAIN OUTCOME MEASURE: The RIT, defined as the time taken after a photobleach for visual sensitivity to recover detection of a 5×10-3 cd/m2 stimulus (a decrease of 3 log units), was monitored in study eyes over 4 years, and the mean rate of change was computed. RESULTS: Longitudinal analysis of 65 study eyes followed on the standard testing protocol (mean age, 71±9.3 years; 49% were female) revealed that higher rates of RIT prolongation were correlated with AMD severity group assignment at baseline (P = 0.026) and with severity group assignments at year 4 (P = 0.0011). Study eyes that developed SDD during follow-up demonstrated higher rates of RIT prolongation relative to those that did not (P < 0.0001). Overall, higher rates of RIT prolongation were significantly correlated with greater 4-year decreases in LLQ scores (total mean score, P = 0.0032). CONCLUSIONS: Longitudinal decline in DA function, which correlated with patient-reported functional deficits, was accelerated in eyes with greater AMD severity and especially in eyes with SDD both at baseline and at 4 years. The RIT prolongation as a measure of changing DA function may be a functional outcome measure in AMD clinical studies.


Assuntos
Adaptação à Escuridão/fisiologia , Degeneração Macular/fisiopatologia , Drusas Retinianas/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Estudos Longitudinais , Degeneração Macular/diagnóstico , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Drusas Retinianas/diagnóstico , Células Fotorreceptoras Retinianas Bastonetes/fisiologia , Inquéritos e Questionários , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
3.
Surv Ophthalmol ; 63(2): 257-267, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28941765

RESUMO

Cataract surgery with phacoemulsification is a challenging procedure for surgeons in training to learn to perform safely, efficiently, and effectively. We review the auxiliary learning tools outside the operating room that residency programs have incorporated into their curriculum to improve surgical skills, including wet laboratory and surgical simulators. We then discuss different methods of teaching cataract surgery in the operating room. Our goal is to define a learning curve for cataract surgery. We demonstrate that complication rates decline significantly after a resident performs an average of 70 cases. We summarize the reported incidence and risk factors for complications in resident-performed cataract surgery to help identify cases that require a higher level of skill to improve visual outcomes. We suggest that future studies include details on preoperative comorbidities, risk stratification, resident skill level, and frequency of takeover by attending.


Assuntos
Educação de Pós-Graduação em Medicina/métodos , Internato e Residência , Oftalmologia/educação , Facoemulsificação/educação , Ensino/organização & administração , Avaliação Educacional , Humanos , Estados Unidos
4.
Ophthalmology ; 124(9): 1332-1339, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28602520

RESUMO

PURPOSE: We investigate whether responses on a Low Luminance Questionnaire (LLQ) in patients with a range of age-related macular degeneration (AMD) severity are associated with their performance on focal dark adaptation (DA) testing and with choroidal thickness. DESIGN: Cross-sectional, single-center, observational study. PARTICIPANTS: A total of 113 participants older than 50 years of age with a range of AMD severity. METHODS: Participants answered the LLQ on the same day they underwent DA testing using a focal dark adaptometer measuring rod intercept time (RIT). We performed univariable and multivariable analyses of the LLQ scores and age, RIT, AMD severity, subfoveal choroidal thickness [SFCT], phakic status, and best-corrected visual acuity. MAIN OUTCOME MEASURES: The primary outcome of this study was the score on the 32-question LLQ. Each item in the LLQ is designated to 1 of 6 subscales describing functional problems in low luminance: driving, emotional distress, mobility, extreme lighting, peripheral vision, and general dim lighting. Scores were computed for each subscale, in addition to a weighted total mean score. RESULTS: Responses from 113 participants (mean age, 76.2±9.3 years; 58.4% were female) and 113 study eyes were analyzed. Univariable analysis demonstrated that lower scores on all LLQ subscales were correlated with prolonged DA testing (longer RIT) and decreased choroidal thickness. All associations were statistically significant except for the association of choroidal thickness and "peripheral vision." The strongest association was the LLQ subscale of driving with RIT (r =-0.97, P < 0.001). Multivariable analysis for each of the LLQ subscale outcomes, adjusted for age, included RIT, with total LLQ score, "driving," "extreme lighting," and "mobility" also including choroidal thickness. In all multivariable analyses, RIT had a stronger association than choroidal thickness. CONCLUSIONS: This cross-sectional analysis demonstrates associations of patient-reported functional deficits, as assessed on the LLQ, with both reduced DA and reduced choroidal thickness, in a population of older adults with varying degrees of AMD severity and good visual acuity in at least 1 eye. These analyses suggest that local functional measurements of DA testing (RIT) and choroidal thickness are associated with patient-reported functional deficits.


Assuntos
Adaptação à Escuridão/fisiologia , Luz , Degeneração Macular/fisiopatologia , Visão Noturna/fisiologia , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Corioide/patologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Visão Ocular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA