Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Am J Transplant ; 14(1): 156-62, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24369024

RESUMO

Cytomegalovirus (CMV) infection remains a major source of morbidity and mortality in solid organ transplant recipients. Killer immunoglobulin-like receptors(KIR) are genetically polymorphic natural killer(NK) cell receptors important in antiviral responses. A retrospective, single-center cohort study was performed to study the interaction of KIR genotype and primary control of CMV infection after transplantation.Time to first CMV viremia was determined for a cohort of 531 CMV serology donor positive/recipient negative solid organ transplant recipients. Of the KIR genes,KIR2DL3 and KIR2DS2 were most strongly associated with time to CMV viremia in random survival forest analysis. As KIR2DL3 and KIR2DS2 both interact with HLA-C1, these interactions were evaluated. Seventy six recipients were found to be positive for both KIR2DL3 and KIR2DS2 and expressed only HLA-C1 antigens in both recipient and donor. These patients had a substantially reduced hazard of CMV viremia in the first year after solid organ transplantation (hazard ratio 0.44, 95% CI 0.27­0.72, p=0.0012). In KIR2DL3+/KIR2DS2+/HLA-C1/1 recipients who received an organ from a non-C1/1 donor, this protective effect was not observed. These results improve our understanding of human NK cell function in primary CMV infection after transplant.


Assuntos
Infecções por Citomegalovirus/imunologia , Antígenos HLA-C/imunologia , Células Matadoras Naturais/imunologia , Receptores KIR/genética , Transplantes/virologia , Viremia/imunologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Receptores de Células Matadoras Naturais , Estudos Retrospectivos
2.
J Clin Microbiol ; 50(12): 4120-2, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23035203

RESUMO

A comparison of direct fluorescent-antibody assay (DFA), culture, and two PCR assays disclosed sensitivities of 87.8%, 46.3%, and 97.6% and 100%, respectively. We reviewed 1,150 results for clinical specimens submitted for DFA and culture and found that only 17 were culture positive/DFA negative. The incremental cost to detect these 17 positives was $3,078/specimen.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por Herpesviridae/diagnóstico , Herpesvirus Humano 3/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Técnica Direta de Fluorescência para Anticorpo/métodos , Infecções por Herpesviridae/virologia , Herpesvirus Humano 3/genética , Herpesvirus Humano 3/crescimento & desenvolvimento , Herpesvirus Humano 3/imunologia , Humanos , Sensibilidade e Especificidade , Cultura de Vírus/métodos
3.
J Breath Res ; 5(3): 037107, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21757798

RESUMO

For the 2009 influenza A (H1N1) pandemic, vaccination and infection control were the main modes of prevention. A live attenuated H1N1 vaccine mimics natural infection and works by evoking a host immune response, but currently there are no easy methods to measure such a response. To determine if an immune response could be measured in exhaled breath, exhaled nitric oxide (FE(NO)) and other exhaled breath volatiles using selected ion flow tube mass spectrometry (SIFT-MS) were measured before and daily for seven days after administering the H1N1 2009 monovalent live intranasal vaccine (FluMist®, MedImmune LLC) in nine healthy healthcare workers (age 35 ± 7 years; five females). On day 3 after H1N1 FluMist® administration there were increases in FE(NO) (MEAN±SEM: day 0 15 ± 3 ppb, day 3 19 ± 3 ppb; p < 0.001) and breath isoprene (MEAN±SEM: day 0 59 ± 15 ppb, day 3 99 ± 17 ppb; p = 0.02). MS analysis identified the greatest number of changes in exhaled breath on day 3 with 137 product ion masses that changed from baseline. The exhaled breath changes on day 3 after H1N1 vaccination may reflect the underlying host immune response. However, further work to elucidate the sources of the exhaled breath changes is necessary.


Assuntos
Ar/análise , Testes Respiratórios/métodos , Vírus da Influenza A Subtipo H1N1/imunologia , Vacinas contra Influenza/administração & dosagem , Influenza Humana/prevenção & controle , Óxido Nítrico/farmacologia , Vacinas Atenuadas/administração & dosagem , Administração Intranasal , Adulto , Expiração , Feminino , Humanos , Influenza Humana/virologia , Masculino , Espectrometria de Massas , Valores de Referência , Vacinação/métodos
4.
Antimicrob Agents Chemother ; 54(5): 2248-51, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20194699

RESUMO

A high-resolution melt (HRM) assay using a Rotor-Gene 6000 instrument was developed to characterize the codon for glycine 54 in the cyp51A genes from 13 reference isolates and 12 clinical isolates of Aspergillus fumigatus. Mutations in this codon confer reduced susceptibility to itraconazole and posaconazole. The assay is simple to perform, and a result of "wild type" or "mutant" is available after approximately 1 h following DNA extraction using commercially available reagents and conventional primers.


Assuntos
Aspergillus fumigatus/efeitos dos fármacos , Aspergillus fumigatus/genética , Sistema Enzimático do Citocromo P-450/genética , Farmacorresistência Fúngica/genética , Proteínas Fúngicas/genética , Testes de Sensibilidade Microbiana/métodos , Antifúngicos/farmacologia , Códon/genética , Genes Fúngicos/genética , Testes Genéticos/métodos , Glicina/genética , Itraconazol/farmacologia , Desnaturação de Ácido Nucleico , Análise de Sequência de DNA/métodos , Triazóis/farmacologia
5.
J Clin Microbiol ; 47(5): 1491-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19321732

RESUMO

A novel method for the collection and transportation of dried-blood-plasma samples, SampleTanker (ST), was developed and compared to standard shipping protocols for frozen-plasma specimens containing human immunodeficiency virus type 1 (HIV-1) and/or hepatitis C virus (HCV). Matched frozen and dried 1-ml EDTA-containing plasma samples were collected and analyzed by several molecular-based virologic assays. After addition of 1.175 ml of reconstitution buffer, 1.035 ml of dried plasma was recovered. Mean intra-assay variances were 0.05, 0.05, and 0.06 log(10) copies/ml for the Versant, Amplicor, and NucliSens QT HIV-1 load assays, respectively (P, not significant). However, mean HIV-1 viral load was consistently reduced in dried samples by 0.32 to 0.51 log(10) copies/ml, depending on assay type (P < 0.05). Infectious HIV-1 was not recovered from dried ST plasma. There was no significant difference in HIV-1 viral load results obtained using ST after 8 weeks of storage at ambient temperature. Compared to frozen plasma, HIV-1 genotypic results were >99% concordant at the nucleotide and amino acid levels, as well as for resistance-associated mutations. We further demonstrated successful detection of multiple analytes, including HIV-1 viral load, HIV-1 antiretroviral resistance genotype, and HCV genotype, from a single ST unit. Dried plasma collected with ST yielded comparable results to frozen samples for multiple-analyte clinical testing. As such, ST could be a useful alternative for virologic tests and clinical trials worldwide by significantly diminishing transportation cost and the sample volume restrictions associated with dried-blood-spot technology.


Assuntos
Dessecação , Infecções por HIV/diagnóstico , HIV/isolamento & purificação , Hepacivirus/isolamento & purificação , Hepatite C/diagnóstico , Plasma/virologia , Manejo de Espécimes/métodos , Genótipo , Humanos , Testes de Sensibilidade Microbiana , Reprodutibilidade dos Testes , Carga Viral
6.
J Clin Microbiol ; 44(5): 1726-32, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16672399

RESUMO

We report a multilaboratory evaluation of hepatitis C virus (HCV) viral load assays to determine their linear range, reproducibility, subtype detection, and agreement. A panel of HCV RNA samples ranging in nominal concentration from 1.0 to 7.0 log10 IU/ml was constructed by diluting a clinical specimen (genotype 1b). Replicates of the panel were tested in multiple laboratories using the Abbott TaqMan analyte-specific reagent (Abbott reverse transcription-PCR [RT-PCR]), Roche TaqMan RUO (Roche RT-PCR), Roche Amplicor Monitor HCV 2.0 (Roche Monitor), and Bayer VERSANT HCV RNA 3.0 (Bayer bDNA) assays. Bayer bDNA-negative specimens were tested reflexively using the Bayer VERSANT HCV RNA qualitative assay (Bayer TMA). Abbott RT-PCR and Roche RT-PCR detected all 28 replicates with a concentration of 1.0 log10 IU/ml and were linear to 7.0 log10 IU/ml. Roche Monitor and Bayer bDNA detected 27 out of 28 and 13 out of 28 replicates, respectively, of 3.0 log10 IU/ml. Bayer TMA detected all seven replicates with 1.0 log10 IU/ml. Bayer bDNA was the most reproducible of the four assays. The mean viral load values for panel members in the linear ranges of the assays were within 0.5 log10 for the different tests. Eighty-nine clinical specimens of various genotypes (1 through 4) were tested in the Bayer bDNA, Abbott RT-PCR, and Roche RT-PCR assays. For Abbott RT-PCR, mean viral load values were 0.61 to 0.96 log10 greater than the values for Bayer bDNA assay for samples with genotype 1, 2, or 3 samples and 0.08 log10 greater for genotype 4 specimens. The Roche RT-PCR assay gave mean viral load values that were 0.28 to 0.82 log10 greater than those obtained with the Bayer bDNA assay for genotype 1, 2, and 3 samples. However, for genotype 4 samples the mean viral load value obtained with the Roche RT-PCR assay was, on average, 0.15 log10 lower than that of the Bayer bDNA. Based on these data, we conclude that the sensitivity and linear range of the Abbott and Roche RT-PCR assays enable them to be used for HCV diagnostics and therapeutic monitoring. However, the differences in the viral load values obtained with the different assays underscore the importance of using one assay when monitoring response to therapy.


Assuntos
Hepacivirus/isolamento & purificação , Virologia/métodos , Genótipo , Hepacivirus/genética , Hepatite C/virologia , Humanos , Laboratórios , RNA Viral/sangue , RNA Viral/genética , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/estatística & dados numéricos , Sensibilidade e Especificidade , Viremia/virologia , Virologia/estatística & dados numéricos
7.
J Clin Microbiol ; 43(3): 1385-6, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15750113

RESUMO

We sought to determine if the BK and JC polyomaviruses were associated with idiopathic pulmonary fibrosis (IPF). We did not detect the BK or JC polyomaviruses in lung tissue extracts from 33 patients with IPF by using real-time PCR, which suggests that an etiologic association is unlikely.


Assuntos
Vírus BK/isolamento & purificação , Vírus JC/isolamento & purificação , Pulmão/virologia , Fibrose Pulmonar/etiologia , Humanos , Reação em Cadeia da Polimerase , Fibrose Pulmonar/virologia
8.
Bone Marrow Transplant ; 34(12): 1071-5, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15489872

RESUMO

Ganciclovir-resistant cytomegalovirus (CMV) infection is an emerging problem in transplant recipients. Foscarnet resistance and cidofovir resistance have also been described, but no previous reports have suggested treatment regimens for patients with CMV refractory to all three of these drugs. Leflunomide, an immunosuppressive drug used in rheumatoid arthritis and in rejection in solid-organ transplantation, has been reported to have novel anti-CMV activity. However, its clinical utility in CMV treatment has not been described previously. We report an allogeneic bone marrow transplant recipient who developed CMV infection refractory to sequential therapy with ganciclovir, foscarnet, and cidofovir. The patient was ultimately treated with a combination of leflunomide and foscarnet. Both phenotypic and genotypic virologic analysis was performed on sequential CMV isolates. The patient's high CMV-DNA viral load became undetectable on leflunomide and foscarnet, but the patient, who had severe graft-versus-host disease (GVHD) of the liver, expired with progressive liver failure and other complications. We concluded that leflunomide is a new immunosuppressive agent with anti-CMV activity, which may be useful in the treatment of multiresistant CMV. However, the toxicity profile of leflunomide in patients with underlying GVHD remains to be defined.


Assuntos
Transplante de Medula Óssea/efeitos adversos , Infecções por Citomegalovirus/tratamento farmacológico , Isoxazóis/uso terapêutico , Terapia de Salvação/métodos , Farmacorresistência Viral , Quimioterapia Combinada , Evolução Fatal , Feminino , Foscarnet/uso terapêutico , Doença Enxerto-Hospedeiro , Humanos , Imunossupressores/uso terapêutico , Leflunomida , Leucemia Mielogênica Crônica BCR-ABL Positiva/complicações , Leucemia Mielogênica Crônica BCR-ABL Positiva/terapia , Falência Hepática , Pessoa de Meia-Idade , Transplante Homólogo , Carga Viral/métodos
9.
Clin Exp Rheumatol ; 21(6 Suppl 32): S101-11, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14740435

RESUMO

OBJECTIVE: Chronic hepatitis C virus (HCV) infection is associated with an array of autoimmune laboratory and clinical manifestations. The goals of our study were to identify host and/or virological factors that are implicated in the pathogenesis of these manifestations. METHODS: We performed a detailed prospective study of various demographic, virological, biochemical, immunological (including lymphocyte subsets, Fc gamma-receptor and HLA class-II genotyping), histological and host genetic parameters in 3 well defined subgroups of HCV patients (n = 40): patients with liver disease only (group I, n = 11) or with laboratory (group II, n = 20) and clinical (group III, n = 9) autoimmune manifestations. RESULTS: Group III patients, mainly with features of mixed cryoglobulinemia, were older, with higher levels of rheumatoid factor and circulating cryoglobulins while they tended to have a longer estimated disease duration compared to the other two groups of patients. We did not identify any specific immunological features that could differentiate symptomatic versus asymptomatic patients, except from the elevated soluble interleukin-2 receptor levels. An increased frequency of the R/R131 FcR gamma IIIA and the NA1/NA1 Fc gamma RIIIB genotypes was observed in our total HCV population, regardless of autoimmune manifestations, compared to historical controls. No statistically significant differences in HLA class II allele frequencies was detected between patient subgroups or in comparison to healthy controls. CONCLUSIONS: Chronically infected HCV patients with symptomatic mixed cryoglobulinemia display a number of unique characteristics that differentiate them from asymptomatic patients with chronic hepatitis C.


Assuntos
Doenças Autoimunes/imunologia , Doenças Autoimunes/virologia , Hepatite C Crônica/complicações , Hepatite C Crônica/imunologia , Adulto , Idoso , Doenças Autoimunes/genética , Crioglobulinemia/genética , Crioglobulinemia/imunologia , Crioglobulinemia/virologia , Citocinas/sangue , Feminino , Genótipo , Hepatite C Crônica/genética , Antígenos de Histocompatibilidade Classe II/genética , Teste de Histocompatibilidade , Humanos , Subpopulações de Linfócitos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Receptores de Citocinas/sangue , Receptores de IgG/genética
11.
Transpl Infect Dis ; 4(4): 189-94, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12535261

RESUMO

BACKGROUND: Ganciclovir-resistant (GCV-R) cytomegalovirus (CMV) is now being reported with increasing frequency in solid organ transplant recipients. OBJECTIVE: To describe the clinical characteristics and outcomes of all solid organ transplant patients with GCV-R CMV seen between 1990 and 2000 at a single center. METHODS: Patients with clinically suspected GCV resistance had viral isolates subjected to phenotypic analysis by plaque reduction assay, and also genotypic analysis. Medical records of the 13 patients with GCV-R CMV were reviewed for demographic, microbiologic, clinical, and pathologic data. RESULTS: Thirteen patients were identified, including 5 kidney, 1 heart, and 7 lung transplant recipients. All but one patient (92%) were CMV donor seropositive, recipient negative (D+/R-), and 11/13 (85%) had tissue-invasive CMV. CMV viremia was recurrent in 9/13 (69%); in 2 others, the first CMV episode was fatal. Overall, 9/13 (69%) of patients have died, all of CMV or its complications. Of the 10 who received foscarnet, only one survived. All patients had received GCV-based prophylactic regimens; 8/13 patients (62%) had received CMV hyperimmune globulin (CMVIG) as part of prophylaxis, 6/13 (46%) had received oral ganciclovir, and 5/13 (38%) had received intermittent (3 x/week) IV ganciclovir for prophylaxis. CONCLUSIONS: GCV-R CMV is associated with CMV D+/R- status, tissue-invasive disease, and high mortality even with foscarnet therapy. Exposure to less than fully therapeutic levels of GCV, in the form of oral or intermittent IV GCV, is common. The use of CMVIG in prophylaxis does not appear to prevent resistance. Further work remains to be done to elucidate the risk factors and optimal mode of prophylaxis and treatment for GCV-R CMV.


Assuntos
Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/prevenção & controle , Ganciclovir/uso terapêutico , Transplante de Órgãos/efeitos adversos , Citomegalovirus/patogenicidade , Infecções por Citomegalovirus/terapia , Farmacorresistência Viral , Quimioterapia Combinada , Feminino , Foscarnet/farmacologia , Foscarnet/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade
12.
Transplantation ; 71(10): 1486-7, 2001 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-11391241

RESUMO

Severe recurrent cholestatic hepatitis C after liver transplantation has a poor prognosis and no standard therapy is currently available. Four cases of severe recurrent cholestatic hepatitis C treated with a combination of interferon alpha 2b and ribavirin are described. All four patients were transplanted for hepatitis C-related cirrhosis. The mean age at transplantation was 45 years (range 41-51 years). Three of the patients were male and one was female. All four patients had hepatitis C virus viremia before and after liver transplantation. At 2 to 23 months after liver transplantation, all four patients developed jaundice, cholestatic elevation of liver enzymes, and histopathology consistent with severe recurrent cholestatic hepatitis C. Combination of interferon and ribavirin was given with prompt virological suppression. Despite this rapid viral suppression, all four patients developed progressive graft failure with three deaths.


Assuntos
Antivirais/uso terapêutico , Colestase/virologia , Hepatite C/complicações , Hepatite C/tratamento farmacológico , Interferon-alfa/uso terapêutico , Transplante de Fígado , Ribavirina/uso terapêutico , Adulto , Quimioterapia Combinada , Evolução Fatal , Feminino , Hepatite C/etiologia , Humanos , Interferon alfa-2 , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Proteínas Recombinantes , Recidiva , Índice de Gravidade de Doença
13.
J Clin Gastroenterol ; 33(1): 45-8, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11418790

RESUMO

Hepatitis C RNA testing has been used extensively to assess the efficacy of antiviral therapy and has increasingly become an integral part of clinical management of patients with chronic hepatitis C. A variety of commercially available hepatitis C virus (HCV) RNA tests are used to detect HCV RNA qualitatively or quantitatively. These commercial tests have fundamental differences that are reflected on the values they generate. We compared two widely used assays, HCV SuperQuant (SQ) and Amplicor HCV Monitor (M1 and M2), in sera of patients with chronic hepatitis C. A total of 506 sera from 79 patients were tested with both assays. The data were logarithmically transformed and analyzed by linear regression and measurement of agreement. Two hundred thirty-eight sera had HCV RNA values within the dynamic range of both assays. The correlation between the assays was fair, with a correlation coefficient (r) of 0.699. Overall, SQ generated higher values than M1 with a mean difference of 0.558 log (SD = 0.624). One hundred ninety-four (38%) and 121 (24%) of the sera were below the dynamic range of M1 and SQ, respectively. Seventy-three sera, undetectable by M1, were positive by SQ. The Amplicor HCV Monitor 2.0 (M2) was performed in 66 sera. All were positive by SQ and M2, but only 38 were within the dynamic range of M1. The correlations between these tests were good (r = 0.68-0.78), but the agreement was rather poor. In conclusion, this study confirms that both SQ and M2 are more sensitive than M1. Additionally, our results show rather poor agreements between these assays. The recent attempts in standardizing the reporting of these assays should make their results more easily interchangeable.


Assuntos
Hepacivirus/genética , Hepatite C Crônica/diagnóstico , RNA Viral/sangue , Adulto , Antivirais/uso terapêutico , Feminino , Genótipo , Hepatite C Crônica/tratamento farmacológico , Hepatite C Crônica/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Valor Preditivo dos Testes , Resultado do Tratamento , Carga Viral , Replicação Viral/efeitos dos fármacos
14.
J Clin Microbiol ; 39(4): 1334-8, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11283052

RESUMO

We analyzed the performance characteristics of the qualitative AMPLICOR CMV Test (Roche Molecular Systems, Pleasanton, Calif.) and quantitative COBAS AMPLICOR CMV MONITOR Test (Roche Molecular Systems) assays and compared the performance of the AMPLICOR quantitative assay with an in-house-developed cytomegalovirus (CMV) DNA PCR assay. The quantitative AMPLICOR assay was found to be more sensitive than the qualitative AMPLICOR assay. The quantitative AMPLICOR assay has a lower limit of sensitivity of 400 CMV DNA copies/ml of plasma and is linear to 50,000 CMV DNA copies/ml of plasma. Compared to the in-house PCR assay, the AMPLICOR quantitative assay gave lower viral load values at all concentrations tested, but the difference between the two assays was not consistent across the entire dynamic range of the AMPLICOR quantitative assay. At the lower end of the assay, the viral load values obtained with the in-house PCR assay were three- to fivefold (0.5 to 0.7 log units) higher than those measured with the AMPLICOR assay. At higher input concentrations, the differences between the two assays approached 10-fold. This direct comparison of the in-house assay and the quantitative AMPLICOR assay provides the ability to compare previously published in-house data with an assay widely available for future research and clinical monitoring of patients with CMV infections.


Assuntos
Infecções por Citomegalovirus/virologia , Citomegalovirus/genética , Citomegalovirus/isolamento & purificação , DNA Viral/sangue , Reação em Cadeia da Polimerase/métodos , Carga Viral , Humanos , Kit de Reagentes para Diagnóstico
15.
Arch Pathol Lab Med ; 124(8): 1220-3, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10923088

RESUMO

Direct immunofluorescence assays (DFAs) are used in the clinical virology laboratory for the rapid detection of viruses. An assessment of the cellularity of specimens submitted for DFA is necessary for the most effective use of this assay. This assessment ensures that an adequate number of the appropriate cells are present for examination. During this assessment, clinical virologists may encounter unfamiliar cellular elements or cellular fragments. One of these elements, ciliocytophthoria, has been misinterpreted as a parasite in specimens submitted for cytologic testing. We describe a similar case in which a technologist thought that ciliocytophthoria possibly represented a ciliated parasite in a nasopharyngeal specimen sent for respiratory syncytial virus DFA. After a thorough morphologic examination, the staff dismissed the possibility of a ciliated parasite. We confirmed this entity as ciliocytophthoria using morphologic criteria and the Diff-Quik stain. This near misidentification of ciliocytophthoria as a ciliated parasite affords us the opportunity to raise the awareness of clinical virologists about ciliocytophthoria. Additionally, we briefly review useful features for differentiating ciliocytophthoria from the only ciliate parasitic for humans, Balantidium coli. Finally, we present the utility of a commonly used cytologic stain, the Diff-Quik stain, for the confirmation of ciliocytophthoria.


Assuntos
Artefatos , Cílios/ultraestrutura , Células Epiteliais/ultraestrutura , Virologia/métodos , Balantidíase/diagnóstico , Diagnóstico Diferencial , Erros de Diagnóstico/prevenção & controle , Técnica Direta de Fluorescência para Anticorpo , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Infecções por Vírus Respiratório Sincicial/diagnóstico
16.
J Clin Microbiol ; 38(8): 2837-45, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10921936

RESUMO

The QUANTIPLEX HIV-1 RNA assay, version 3.0 (a branched DNA, version 3.0, assay [bDNA 3.0 assay]), was evaluated by analyzing spiked and clinical plasma samples and was compared with the AMPLICOR HIV-1 MONITOR Ultrasensitive (ultrasensitive reverse transcription-PCR [US-RT-PCR]) method. A panel of spiked plasma samples that contained 0 to 750,000 copies of human immunodeficiency virus type 1 (HIV-1) RNA per ml was tested four times in each of four laboratories (1,344 assays). Negative results (<50 copies/ml) were obtained in 30 of 32 (94%) assays with seronegative samples, 66 of 128 (52%) assays with HIV-1 RNA at 50 copies/ml, and 5 of 128 (4%) assays with HIV-1 RNA at 100 copies/ml. The assay was linear from 100 to 500,000 copies/ml. The within-run standard deviation (SD) of the log(10) estimated HIV-1 RNA concentration was 0.08 at 1,000 to 500,000 copies/ml, increased below 1,000 copies/ml, and was 0.17 at 100 copies/ml. Between-run reproducibility at 100 to 500 copies/ml was <0.10 log(10) in most comparisons. Interlaboratory differences across runs were /=50 copies/ml when they were retested by the US-RT-PCR assay (median, 86 copies/ml; range, 50 to 217 copies/ml). Estimation of bDNA 3.0 values of <50 copies/ml by extending the standard curve of the assay showed that these samples with discrepant results had higher HIV-1 RNA levels than the samples with concordant results (median, 34 versus 17 copies/ml; P = 0.0051 by the Wilcoxon two-sample test). The excellent reproducibility, broad linear range, and good sensitivity of the bDNA 3.0 assay make it a very attractive method for quantitation of HIV-1 RNA levels in plasma.


Assuntos
Infecções por HIV/virologia , HIV-1/isolamento & purificação , Hibridização de Ácido Nucleico/métodos , RNA Viral/sangue , Sondas de DNA , Estudos de Avaliação como Assunto , HIV-1/genética , HIV-1/fisiologia , Humanos , Laboratórios/normas , Kit de Reagentes para Diagnóstico/normas , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade , Viremia/virologia
17.
Prog Transplant ; 10(1): 42-6, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10941326

RESUMO

CONTEXT: Serological markers for the hepatitis B virus are routinely used in the evaluation of potential organ donors. However, serological tests can be associated with significant false or equivocal results and may not be indicative of the true risk of hepatitis B infection. Studies have recently questioned the significance of an isolated hepatitis B core antibody test in evaluating the suitability of solid organs for transplantation. The ability to detect hepatitis B virus DNA may prove useful when the diagnosis of hepatitis B infection is in doubt. DESIGN: Serum samples from 16 donors with equivocal or positive hepatitis B core antibody and/or hepatitis B surface antigen serological screening tests were retrospectively tested for the presence of hepatitis B DNA. Any available follow-up data on the placement of organs from these donors was obtained. RESULTS: One of the 16 (6.3%) donors tested positive for the presence of hepatitis B DNA, but organs from this donor were not recovered or transplanted. Follow-up on 14 organs recovered and transplanted from 6 donors in this group did not show clinical and/or laboratory evidence of hepatitis B infection in the recipients. CONCLUSIONS: In our donor population, there was a low incidence (6.3%) of donors with equivocal or positive hepatitis B core antibody and/or hepatitis B surface antigen serological screening tests who subsequently demonstrated the presence of detectable hepatitis B DNA. Posttransplantation follow-up of the recipients of 14 recovered organs failed to demonstrate any cases of posttransplant hepatitis B infection.


Assuntos
DNA Viral/análise , DNA Viral/genética , Vírus da Hepatite B/genética , Hepatite B/sangue , Hepatite B/diagnóstico , Programas de Rastreamento/métodos , Hibridização de Ácido Nucleico/métodos , Doadores de Tecidos , Obtenção de Tecidos e Órgãos/métodos , Seguimentos , Hepatite B/imunologia , Antígenos do Núcleo do Vírus da Hepatite B/sangue , Antígenos de Superfície da Hepatite B/sangue , Humanos , Reprodutibilidade dos Testes
18.
J Clin Microbiol ; 38(6): 2348-53, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10835001

RESUMO

We have evaluated two commercially available kits (AMPLICOR MONITOR [Roche] and NASBA HIV-1 QT or NucliSens HIV-1 QT [Organon Teknika]) and two noncommercial methods for the accurate quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in seminal plasma. The same panels of coded specimens were tested on four separate occasions. Laboratories using the commercial assays employed silica beads to isolate HIV-1 RNA, which removed inhibitory factors sometimes found in seminal plasma. Sensitivities and specificities, respectively, for each assay were as follows: AMPLICOR MONITOR, 100 and 73%; NASBA HIV-1 QT, 84 and 100%; NucliSens HIV-1 QT, 99 and 98%; and noncommercial assays, 91 and 73%. When results from the laboratory that was inexperienced with the silica bead extraction method were excluded from the analysis, specificity for the Roche assay increased to 100%. The commercial assays demonstrated highly reproducible results, with intra-assay standard deviations (measured in log(10) RNA copies/milliliter of seminal plasma) ranging from 0.11 to 0.32; those of the noncommercial assays ranged from 0.12 to 0.75. Differences in mean estimated HIV-1 RNA concentrations were

Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , RNA Viral/análise , Kit de Reagentes para Diagnóstico , Sêmen/virologia , Análise de Variância , Estudos de Avaliação como Assunto , Infecções por HIV/sangue , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral
19.
J Infect Dis ; 181(4): 1486-90, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10762582

RESUMO

Human immunodeficiency virus (HIV) type 1-infected persons with newly diagnosed Mycobacterium avium complex (MAC) bacteremia were enrolled in an 8-week study to determine whether treatment of MAC infection is associated with decreases in plasma tumor necrosis factor (TNF)-alpha levels. Blood specimens were obtained for quantitative MAC cultures and to determine plasma levels of HIV RNA, TNF-alpha, and other proinflammatory cytokines. MAC levels decreased by 1.75 log at week 4 (P=.008) and by 2.48 log at week 8 (P=.001). Plasma TNF-alpha decreased by 0.15 log at week 4 (P=.042) and by 0. 40 log at week 8 (P=.027). Plasma interleukin (IL)-6 decreased by 0. 56 log at week 8 (P=.039). There were nonsignificant trends (P<.10) for plasma levels of IL-1beta and HIV RNA to decrease at week 8. Nonsignificant decreases in plasma levels of TNF-alpha, IL-1beta, IL-6, and HIV RNA were also seen in those individuals who remained on stable antiretroviral therapy throughout the 8 weeks of the study.


Assuntos
Infecções Oportunistas Relacionadas com a AIDS/sangue , Infecções Oportunistas Relacionadas com a AIDS/tratamento farmacológico , Citocinas/sangue , Infecção por Mycobacterium avium-intracellulare/sangue , Infecção por Mycobacterium avium-intracellulare/tratamento farmacológico , Adulto , Antibacterianos/uso terapêutico , Antituberculosos/uso terapêutico , Claritromicina/uso terapêutico , Etambutol/uso terapêutico , Humanos , Interleucina-1/sangue , Interleucina-6/sangue , Projetos Piloto , RNA Viral/análise , Rifabutina/uso terapêutico , Fator de Necrose Tumoral alfa/metabolismo , Carga Viral
20.
Antimicrob Agents Chemother ; 44(3): 688-92, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10681339

RESUMO

Twelve laboratories collaborated in formulating and testing a standardized plaque reduction assay for cytomegalovirus (CMV) cell-associated clinical isolates. Four characterized and plaque-purified CMV strains, as well as six coded clinical isolates obtained after antiviral therapy, were distributed and tested. Good agreement was obtained for four of the clinical isolates, but a broad distribution of results was obtained for two isolates. Analysis of these results indicates the problems associated with clinical isolates, including the large genetic variability and the highly cell-associated phenotype. This collaborative effort, by addressing these problems, represents a significant step toward the development of a standardized assay.


Assuntos
Antivirais/farmacologia , Infecções por Citomegalovirus/virologia , Citomegalovirus/efeitos dos fármacos , Ensaio de Placa Viral/métodos , Ensaio de Placa Viral/normas , Células Cultivadas , Citomegalovirus/fisiologia , Fibroblastos/virologia , Foscarnet/farmacologia , Ganciclovir/farmacologia , Humanos , Laboratórios/normas , Testes de Sensibilidade Microbiana/métodos , Testes de Sensibilidade Microbiana/normas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA