Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Dent ; 146: 105061, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38729289

RESUMO

OBJECTIVES: Orthognathic surgery (OS) has evolved with technological advancements, notably through the implementation of computer-assisted orthognathic surgery (CAOS). This article aims to elucidate various types of CAOS and their efficiency and accuracy, supplemented by a thorough literature review focusing on their clinical applications in South Korea. STUDY SELECTION, DATA, AND SOURCES: A comprehensive search strategy was employed, including systematic reviews, meta-analyses, randomized controlled trials, and observational studies published until December 2023 in the PubMed, MEDLINE, and Google Scholar databases. The literature search was limited to articles written in English. RESULTS: Static CAOS demonstrated high precision, reduced operative time, and high accuracy, suggesting its potential reliability in orthognathic procedures. Dynamic CAOS presented a promising avenue for exploration, showing an accuracy comparable to that of traditional methods. The critical considerations for CAOS include accuracy, time efficiency, and cost-effectiveness. Recent studies have indicated advancements in the time efficiency of static CAOS. Static CAOS requires less equipment and is more cost-effective than dynamic CAOS. CONCLUSIONS: CAOS offers clear advantages over conventional OS in terms of surgical convenience and accuracy in implementing the surgical plan. To achieve recognition as the gold standard method for maxillofacial deformity treatment, CAOS must overcome its limitations and undergo continuous verification via well-designed studies. CLINICAL SIGNIFICANCE: The introduction of CAOS, mainly static CAOS with high precision and reduced surgical time, signifies a notable advancement in OS. However, rigorous studies are warranted to validate CAOS as the gold standard for treating maxillofacial deformities.

2.
Bioengineering (Basel) ; 11(4)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38671740

RESUMO

With the growing demand for orthognathic surgery and other facial treatments, the accurate identification of anatomical landmarks has become crucial. Recent advancements have shifted towards using three-dimensional radiologic analysis instead of traditional two-dimensional methods, as it allows for more precise treatment planning, primarily relying on direct identification by clinicians. However, manual tracing can be time-consuming, mainly when dealing with a large number of patients. This study compared the accuracy and reliability of identifying anatomical landmarks using artificial intelligence (AI) and manual identification. Thirty patients over 19 years old who underwent pre-orthodontic and orthognathic surgery treatment and had pre-orthodontic three-dimensional radiologic scans were selected. Thirteen anatomical indicators were identified using both AI and manual methods. The landmarks were identified by AI and four experienced clinicians, and multiple ANOVA was performed to analyze the results. The study results revealed minimal significant differences between AI and manual tracing, with a maximum deviation of less than 2.83 mm. This indicates that utilizing AI to identify anatomical landmarks can be a reliable method in planning orthognathic surgery. Our findings suggest that using AI for anatomical landmark identification can enhance treatment accuracy and reliability, ultimately benefiting clinicians and patients.

3.
Bioengineering (Basel) ; 10(9)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37760107

RESUMO

Recombinant human bone morphogenetic protein-2 (rhBMP-2) has shown potential in maxillofacial surgery owing to its osteoinductive properties. However, concerns about its safety and high cost have limited its widespread use. This review presents the status of rhBMP-2 use in maxillofacial surgery, focusing on its clinical application, efficacy, safety, and limitations. Studies have demonstrated rhBMP-2's potential to reduce donor site morbidity and increase bone height in sinus and ridge augmentation; however, it may not outperform autogenous bone grafts. In medication-related osteonecrosis of the jaw treatment, rhBMP-2 has been applied adjunctively with promising results, although its long-term safety requires further investigation. However, in maxillofacial trauma, its application is limited to the restoration of large defects. Safety concerns include postoperative edema and the theoretical risk of carcinogenesis. Although postoperative edema is manageable, the link between rhBMP-2 and cancer remains unclear. The limitations include the lack of an ideal carrier, the high cost of rhBMP-2, and the absence of an optimal dosing regimen. In conclusion, rhBMP-2 is a promising graft material for maxillofacial surgery. However, it has not yet become the gold standard owing to safety and cost concerns. Further research is required to establish long-term safety, optimize dosing, and develop better carriers.

4.
Bioengineering (Basel) ; 10(8)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37627799

RESUMO

Maxillofacial skeletal surgery often involves the use of patient-specific implants. However, errors in obtaining patient data and designing and manufacturing patient-specific plates and guides can occur even with accurate virtual surgery. To address these errors, bespoke Snowman plates were designed to allow movement of the mandible. This study aimed to compare the stability of bespoke four-hole miniplates with that of a bespoke Snowman plate for bilateral sagittal split ramus osteotomy (SSRO), and to present a method to investigate joint cavity changes, as well as superimpose virtual and actual surgical images of the mandible. This retrospective study included 22 patients who met the inclusion criteria and underwent orthognathic surgery at a university hospital between 2015 and 2018. Two groups were formed on the basis of the plates used: a control group with four-hole bespoke plates and a study group with bespoke Snowman plates. Stability was assessed by measuring the condyle-fossa space and superimposing three-dimensional virtual surgery images on postoperative cone-beam computed tomography (CBCT) scans. No significant differences were observed in the condyle-fossa space preoperatively and 1 year postoperatively between the control and study groups. Superimposing virtual surgery and CBCT scans revealed minimal differences in the landmark points, with no variation between groups or timepoints. The use of bespoke Snowman plates for stabilizing the mandible following SSRO exhibited clinical stability and reliability similar to those with bespoke four-hole plates. Additionally, a novel method was introduced to evaluate skeletal stability by separately analyzing the condyle-fossa gap changes and assessing the mandibular position.

5.
Bioengineering (Basel) ; 10(5)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37237615

RESUMO

BACKGROUND: Multi-dimensional facial imaging is increasingly used in hospital clinics. A digital twin of the face can be created by reconstructing three-dimensional (3D) facial images using facial scanners. Therefore, the reliability, strengths, and weaknesses of scanners should be investigated and approved; Methods: Images obtained from three facial scanners (RayFace, MegaGen, and Artec Eva) were compared with cone-beam computed tomography images as the standard. Surface discrepancies were measured and analyzed at 14 specific reference points; Results: All scanners used in this study achieved acceptable results, although only scanner 3 obtained preferable results. Each scanner exhibited weak and strong points because of differences in the scanning methods. Scanner 2 exhibited the best result on the left endocanthion; scanner 1 achieved the best result on the left exocanthion and left alare; and scanner 3 achieved the best result on the left exocanthion (both cheeks); Conclusions: These comparative analysis data can be used when creating digital twins through segmentation, selecting and merging data, or developing a new scanner to overcome all shortcomings.

6.
J Funct Biomater ; 13(4)2022 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-36412880

RESUMO

The aim of this study was to compare the mechanical behaviors of three dental implant fixtures with different abutment connection designs. Three implant systems were studied: the control (BLX implant), test group 1 (TORX++ implant), and test group 2 (IU implant). Three samples from each group were subjected to static compression to fracture tests to determine the maximum fracture load, and twelve samples were exposed to fatigue tests that measured how many cycles the implants could endure before deformation or fracture. Detailed images of the implant-abutment assemblies were obtained using micro-computed tomography imaging, and fractured or deformed areas were observed using a scanning electron microscope (SEM). The mean maximum breaking loads of 578.45 ± 42.46 N, 793.26 ± 57.43 N, and 862.30 ± 74.25 N were obtained for the BLX, TORX++, and IU implants, respectively. All samples in the three groups withstood 5 × 106 cycles at 50% of the nominal peak value, and different fracture points were observed. All abutment connection designs showed suitable mechanical properties for intraoral use. Microscopic differences in the fracture patterns may be due to the differences in the fixture design or abutment connection, and mechanical complications could be prevented by lowering the overload reaching the implant or preventing peri-implantitis.

7.
Bioengineering (Basel) ; 9(10)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36290451

RESUMO

(1) Background: The stability of implants plays a significant role in the success of osseointegration. The stability of the connection between the fixture and the abutment is one of the critical factors affecting osseointegration. When restoring multiple, non-parallel, and splinted implants, achieving a passive fit can be complicated and challenging. A new EZ post non-engaging abutment system of the BlueDiamond® (BD) implant allows a wide connection angle while achieving a passive prosthesis fit. This study aimed to confirm the new abutment system's clinical applicability by evaluating its biomechanical characteristics using finite element analysis (FEA). (2) Methods: The implant-supported fixed three-unit dental prostheses model was reproduced for two groups of AnyOne® (AO) and BD implants using FEA. The loading conditions were a preload of 200 N in the first step and loads of 100 N (axial), 100 N (15°), or 30 N (45°) in the second step. (3) Results: The peak Von Mises stress (PVMS) value of the fixture in the BD group was more than twice that in the AO group. In contrast, the PVMS values of the abutment and abutment screws were lower in the BD group than in the AO group. The AO group revealed higher maximal principal stress (MPS) values than that of the BD group in the cortical bone, cancellous bone, and crown. The average stress of the outer surface of the abutment was lower in the AO group than in the BD group. The stress distribution for the inner surface of the fixture confirmed that the BD group displayed a lower stress distribution than the AO group under axial and 15° loads; however, the average stress was 1.5 times higher at the 45° load. The stress values of the entire surface where the cortical and cancellous bone were in contact with the fixture were measured. The AO group showed a higher stress value than the BD group in both cortical and cancellous bone. (4) Conclusions: In the AO group, the PVMS value of the fixture and the stress distribution at the contact surface between the fixture and the abutment were lower than those of the BD group, suggesting that the stability of the fixture would be high. However, due to the high stress in the fastening area of the abutment and abutment screw, the risk of abutment fracture in the AO group is higher than that of the BD group. Therefore, the new EZ post non-engaging abutment of the BD implant can be used without any problems in clinics, similar to the non-engaging abutment of the AO implant, which has been widely used in clinical practice.

8.
Scanning ; 2022: 8221514, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35316954

RESUMO

Cone-beam computed tomography (CBCT) can distort dentition, and additional imaging is often required. A plaster model to help digitize dental images has been widely used in clinical practice, but there are some inconveniences such as complexity of the process and the risk of damage. The aim of this study was to evaluate the potential for improving dentition imaging with CBCT scans using an intraoral scanner instead of a plaster model. The study used laser model-scanned images of plaster models, imaging from two intraoral scanners, and CBCT images from 20 patients aged 12-18 years. CS 3600 (Carestream Dental, Atlanta, USA) and i700 (Medit, Seoul, Korea) were used as intraoral scanners. The full arch was scanned at once or in three sections using intraoral scanners. The segmented scans were merged to obtain full-arch images. With i700, full-arch images were additionally acquired using its "smart stich" function. The virtual skull-dentition hybrid images obtained from intraoral scanners were superimposed with images obtained using a plaster cast. The difference and distance of coordinate values at each reference point were measured. The average distances from the images obtained with the plaster cast were smaller than 0.39 mm, which is the voxel size of CBCT. Scanning the complete or partial arch using CS 3600 or i700 satisfactorily complemented the CBCT when compared to the plaster model. The virtual skull-dentition hybrid image obtained from intraoral scanners will be clinically useful, especially for patients and surgeons who have difficulty in scanning the complete arch at once.


Assuntos
Dentição , Modelos Dentários , Adolescente , Criança , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Imageamento Tridimensional/métodos , Crânio/diagnóstico por imagem
9.
Biology (Basel) ; 11(3)2022 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-35336755

RESUMO

Aim. To investigate the effect of changes in incisor tip, apex movement, and inclination on skeletal points A and B and characterize changes in skeletal points A and B to the soft tissue points A and B after incisor retraction in Angle Class I bimaxillary dentoalveolar protrusion. Methods. Twenty-two patients with Angle Class I bimaxillary dentoalveolar protrusion treated with four first premolar extractions were included in this study. The displacement of skeletal and soft tissue points A and B was measured using cone-beam computed tomography (CBCT) using a three-dimensional coordinate system. The movement of the upper and lower incisors was also measured using CBCT-synthesized lateral cephalograms. Results. Changes in the incisal tip, apex, and inclination after retraction did not significantly affect the position of points A and B in any direction (x, y, z). Linear regression analysis showed a statistically significant relationship between skeletal point A and soft tissue point A on the anteroposterior axis (z). Skeletal point A moved forward by 0.07 mm, and soft tissue point A moved forward by 0.38 mm, establishing a ratio of 0.18: 1 (r = 0.554, p < 0.01). Conclusion. The positional complexion of the skeletal points A and B was not directly influenced by changes in the incisor tip, apex, and inclination. Although the results suggest that soft tissue point A follows the anteroposterior position of skeletal point A, its clinical significance is suspected. Thus, hard and soft tissue analysis should be considered in treatment planning.

10.
Int J Mol Sci ; 22(22)2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34830400

RESUMO

This study aimed to evaluate the bone regeneration capacity of a customized alloplastic material and xenograft with recombinant human bone morphogenetic protein-2 (rhBMP-2). We prepared hydroxyapatite (HA)/tricalcium phosphate (TCP) pure ceramic bone blocks made using a 3D printing system and added rhBMP-2 to both materials. In eight beagle dogs, a total of 32 defects were created on the lower jaws. The defective sites of the negative control group were left untreated (N group; 8 defects), and those in the positive control group were filled with particle-type Bio-Oss (P group; 12 defects). The defect sites in the experimental group were filled with 3D-printed synthetic bone blocks (3D group; 12 defects). Radiographic and histological evaluations were performed after healing periods of 6 and 12 weeks and showed no significant difference in new bone formation and total bone between the P and 3D groups. The 3D-printed custom HA/TCP graft with rhBMP-2 showed bone regeneration effects similar to that of particulate Bio-Oss with rhBMP-2. Through further study and development, the application of 3D-printed customized alloplastic grafts will be extended to various fields of bone regeneration.


Assuntos
Proteína Morfogenética Óssea 2/genética , Regeneração Óssea/genética , Anormalidades Maxilomandibulares/terapia , Desenvolvimento Maxilofacial/genética , Fator de Crescimento Transformador beta/genética , Animais , Proteína Morfogenética Óssea 2/farmacologia , Regeneração Óssea/efeitos dos fármacos , Substitutos Ósseos/farmacologia , Fosfatos de Cálcio/farmacologia , Cães , Durapatita/farmacologia , Humanos , Arcada Osseodentária/patologia , Anormalidades Maxilomandibulares/genética , Anormalidades Maxilomandibulares/patologia , Impressão Tridimensional , Proteínas Recombinantes/genética , Proteínas Recombinantes/farmacologia , Crânio/efeitos dos fármacos , Crânio/crescimento & desenvolvimento , Crânio/patologia , Fator de Crescimento Transformador beta/farmacologia
11.
J Clin Med ; 10(8)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918920

RESUMO

OBJECTIVE: Orthognathic surgery (OGS) is a surgical intervention that corrects dentofacial deformities through the movement of maxillary and mandibular segments to achieve adequate masticatory function, joint health, and facial harmony. However, some patients present with occlusal discrepancies, condylar sag, and/or temporomandibular disorders after OGS. Various methods have been employed to solve these problems after surgery. This study aimed to evaluate the effectiveness of early screw removal in patients with occlusal discrepancies after OGS using three-dimensional cone-beam computed tomography (CBCT). METHODS: In 44 patients with dentofacial deformities, patient-customized OGSs with customized plates were performed to correct facial deformities using customized guides with computer-aided surgical simulation. Of the 44 patients, eight patients complained of occlusal discrepancies and temporomandibular disorders after OGS. These eight patients underwent screw removal under local anesthesia around four weeks. The temporomandibular joint spaces at three time points (pre-surgical, post-surgical, and after screw removal) in the sagittal and coronal planes were compared using CBCT. RESULTS: Eight patients showed an increase in joint space on CBCT images immediately after surgery (T1), but after early screw removal (T2), these spaces almost returned to their pre-surgical state, and the temporomandibular joint problem disappeared. CONCLUSIONS: The removal of screws located in the distal segment under local anesthesia between three and four weeks post-surgically may be a treatment option for patients with post-OGS occlusal discrepancies, condylar sag, and/or temporomandibular disorder.

13.
Ann Dermatol ; 26(2): 184-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24882972

RESUMO

BACKGROUND: Surgery for bromhidrosis has a high risk of complications such as hematoma and necrosis. New nonsurgical methods may reduce the burden on surgery and the risks for the patient. OBJECTIVE: This study was performed to evaluate the efficacy and side-effects of the 1,444 nm Nd:YAG interstitial laser for treating axillary bromhidrosis. METHODS: Eighteen bromhidrosis patients were treated with a 1,444 nm Nd:YAG laser at Korea University Ansan Hospital. The post-treatment follow-up was 6 months. After the procedure, we confirmed apocrine gland destruction through histopathological examination. At each follow-up, we measured the severity of the remaining odor, postoperative pain, degree of mobility restriction, and overall satisfaction. RESULTS: After 180 days of follow-up, malodor elimination was good in 20 axillae, fair in 12 axillae, and poor in four axillae. At the end point of the study, 14 patients were totally satisfied with the laser treatment, three patients were partially satisfied, and one patient was disatisfied. Pain and limitation of mobility were significantly reduced within 1 week post-operatively, and were almost resolved within 4 weeks post-operatively. A histopathological examination revealed decreased density and significant alterations to the apocrine glands. CONCLUSION: Subdermal coagulation treatment with a 1,444 nm Nd:YAG interstitial laser may be a less invasive and effective therapy for axillary bromhidrosis.

14.
Ann Dermatol ; 26(1): 99-102, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24648694

RESUMO

Bromhidrosis is a disease presenting as malodor caused by interaction between the discharge of apocrine glands and bacteria. The main therapeutic modalities are applying topical agents, liposuction surgery, and elective surgery. Among these, elective surgery is reported to be most effective. However, the efficiency largely depends on surgical technique. Additionally, other side effects, such as hematoma and scarring, are occasionally reported. Currently, CO2 laser and 1,064 nm Nd:YAG laser therapy are used, but as the wavelength is not specific to apocrine glands, these laser therapies have certain limitations. Recently, a 1,444 nm wavelength Accusculpt™ laser (LutronicCorp., Seoul, Korea) has been developed which is now commonly used for facial fat plasty and laser liposuction therapy. The use of this laser for bromhidrosis therapy targeting apocrine sweat glands is currently being discussed. Still, no studies on practical clinical use and side effects of this 1,444 nm wavelength laser have been published. In this report, we treated one bromhidrosis patient with 1,444 nm wavelength Accusculpt™ laser therapy on one side while conventional surgery was performed on the other side using a modified Inaba's method. We compared the efficacy of this laser therapy to the surgical modality by measuring malodor severity and overall satisfaction by questionnaire. We also checked for other complications and recurrence for 12 months after the treatment. This patient was largely satisfied as it has a much shorter down time with the same therapeutic outcome. As subdermal coagulation treatment by 1,444 nm Nd:YAG laser may be less invasive but effective therapy, we would like to recommend this modality as a possible treatment option.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA