Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Beyoglu Eye J ; 8(3): 149-156, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37766761

RESUMO

Objectives: We aimed to investigate the short- and long-term static and dynamic pupillary responses of patients recovered from coronavirus disease-19 (COVID-19) using quantitative infrared pupillography. Methods: This study included patients who recovered from COVID-19 (Group 1) and age- and gender-matched controls (Group 2). A detailed ophthalmic examination was performed at 1 month and 6 months after the diagnosis of COVID-19. Photopic, mesopic, and scotopic pupil diameters (PDs) were measured using a quantitative infrared pupillography which was integrated into Scheimpflug/Placido photography-based topography system. PDs at 0, 2nd, 4th, and 6th seconds, and average pupil dilation speeds at 2nd, 4th, 6th, and 8th seconds were recorded. Results: Eighty-six eyes of 86 patients (Group 1: n=42; Group 2: n=44) were included. While the mean photopic, mesopic, and scotopic PDs were significantly larger in the COVID-19 group than the control group in the 1st month (p=0.035, p=0.017, p=0.018, respectively), no statistically significant difference was found in the 6th month. Besides, average pupil dilation speeds and PDs at the 0, 2nd, 4th, and 6th seconds were not statistically significantly different between the two groups in the 1st month and 6th month. Conclusion: PDs were significantly larger in COVID-19 patients in all light intensities in the 1st month after COVID-19. However, pupillary dilation was transient, and no significant difference was found in the 6th month. We suggest that the transient pupillary dilation may be secondary to the autonomic nervous system dysfunction and/or optic nerve and visual pathways alterations following COVID-19.

2.
J Craniofac Surg ; 32(5): 1770-1774, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33741879

RESUMO

PURPOSE: To evaluate anatomical and functional results of osseointegration with magnetic coupling for oculofacial prosthetic rehabilitation after exenteration. METHODS: This retrospective study included 11 consecutive patients who received orbital reconstruction and oculofacial prosthetic rehabilitation between September 2015 and October 2019. Patient demographics, surgical indications, previous treatment procedures, histopathologic features, and reconstructive procedures were recorded. RESULTS: The mean age was 37.81 ±â€Š23 years (range 5-78 years). The mean follow-up was 23.81 ±â€Š12 months (range 10-48 months). The principal diagnoses were squamous cell carcinoma of the eyelids (n = 2/11), mucoepidermoid carcinoma of the maxillary sinus (n = 2/11), rhabdomyosarcoma (n = 1/11), mucormycosis (n = 1/11), neurofibromatosis (n = 1/11), basosquamous carcinoma (n = 1/11), malign melanoma (n = 1/11), primitive neuroectodermal tumor (n = 1/11), and retinoblastoma (n = 1/11). Six of the patients were repaired by primary closure. Procedures performed to reconstruct the orbital cavity included split-thickness skin graft (n = 2/11), temporalis muscle flap (n = 2/11), and frontalis muscle flap (n = 1/11). Nine of the 11 patients who received orbital implants were successfully rehabilitated by epithesis. Postoperative complications included implant loss (n = 4/11), periprosthetic local infection (n = 3/11), and soft tissue overgrowth around the orbital prosthesis (n = 2/11). All patients had Straumann bone level implant (Basel, Switzerland) osseointegrated titanium implants (3.5 mm) placed in a 2-stage procedure over a span of 3 to 4 months with subsequent successful prosthesis fitting. CONCLUSION: The reconstructive methods following orbital exenteration, should be customized according to the patients' characteristics such as extension of the orbital defect, bone quality, and expectations to achieve satisfactory results.


Assuntos
Prótese Ancorada no Osso , Implantes Dentários , Procedimentos de Cirurgia Plástica , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Humanos , Pessoa de Meia-Idade , Exenteração Orbitária , Próteses e Implantes , Estudos Retrospectivos , Suíça , Adulto Jovem
3.
Eur J Ophthalmol ; 31(2): 346-353, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32452237

RESUMO

PURPOSE: To compare the short-term changes in corneal endothelial cells after trabeculectomy or XEN Gel Stent implantation. DESIGN: Prospective, interventional, comparative study. METHODS: Changes in corneal endothelium in patients that underwent XEN Gel Stent implantation or trabeculectomy were prospectively evaluated. Eighty eyes of 62 diagnosed with open-angle glaucoma were divided into two the trabeculectomy and XEN Gel Stent groups. Corneal specular microscopy was performed at the central cornea using a noncontact specular microscope preoperatively and 3 months after surgery. RESULTS: The baseline mean corneal endothelial cell density in the trabeculectomy group was 2390.3 ± 324.8 cells/mm2, and this was significantly reduced to 2148 ± 352.5 cells/mm2 3 months after surgery, representing a cell loss of 10.0% (p < 0.001). The baseline mean corneal endothelial cell density in the XEN Gel Stent group was 2156.2 ±559.7 cells/mm2, and this was significantly reduced to 2098.4 ± 556.2 cells/mm2 3 months after surgery, representing a cell loss of 2.1% (p = 0.002). The corneal endothelial cell density change rate of the trabeculectomy group (-10.0% ± 9.7%) was statistically higher than the XEN Gel Stent group (-2.1% ± 13.8%) (p = 0.002). A statistically significant difference was observed in the trabeculectomy group between the baseline and postoperative values in the coefficient of variation (p = 0.029). CONCLUSION: Trabeculectomy caused more endothelial cell damage than XEN Gel Stent implantation in the short-term follow-up period. The XEN Gel Stent may be the treatment of choice in patients with a significantly low preoperative corneal endothelial cell density.


Assuntos
Perda de Células Endoteliais da Córnea/etiologia , Endotélio Corneano/patologia , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma de Ângulo Aberto/cirurgia , Trabeculectomia/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Contagem de Células , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Microscopia , Pessoa de Meia-Idade , Estudos Prospectivos , Stents/efeitos adversos
4.
J Craniofac Surg ; 31(7): 1991-1994, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32796299

RESUMO

PURPOSE: To investigate whether impaired lacrimal pump function is a possible cause of discharge in patients wearing an artificial eye compared with the remaining healthy eye. METHODS: Consecutive patients wearing unilateral ocular prosthesis for ≥6 months were included in this retrospective study. Excluded were any deformities of eyelids or nasal passage, socket complications such as entropion, ectropion, ptosis, infection, pyogenic granuloma, contracted socket, obstruction of nasolacrimal duct diagnosed with lacrimal irrigation and a difference greater than 2 mm in terms of protrusion between two eyes detected by Hertel exophthalmometry. Patients were asked to score the levels of tearing and mucopurulent discharge between 0 and 5 to assess lacrimal drainage function subjectively. Furthermore, dacryoscintigraphy was performed to assess the functional status of the lacrimal system objectively. RESULTS: Included were 32 subjects (12 females, 20 males; aged 32.94 ±â€Š17.62, range 13-78). Mean duration of prosthetic wearing 26.41 ±â€Š21.30 (6-72) months. The mean subjective scores of tearing and mucopurulent discharge were 1.56 ±â€Š1.67 and 1.94 ±â€Š1.63, respectively. The rate of functional stenosis was significantly higher in the anophthalmic socket side as compared to the healthy side (P = 0.002). The rates of a presac, preduct, and intraduct obstruction was notes as n = 9, n = 10, n = 1 and n = 0, n = 6, n = 2 in the anophthalmic side and the companion eye, respectively (P = 0.021). CONCLUSION: Compared to paired healthy eyes, the ocular prosthesis exhibited significantly higher rates of functional lacrimal duct obstruction, especially at the presac level. The alterations in orbital volume and tear film composition in addition to reduced corneal reflex blinking may lead to the failure of lacrimal pump function in artificial eyes.


Assuntos
Anoftalmia/diagnóstico por imagem , Obstrução dos Ductos Lacrimais , Adolescente , Adulto , Idoso , Anoftalmia/complicações , Olho Artificial/efeitos adversos , Feminino , Humanos , Aparelho Lacrimal , Obstrução dos Ductos Lacrimais/etiologia , Masculino , Pessoa de Meia-Idade , Cintilografia , Lágrimas , Adulto Jovem
5.
Aesthetic Plast Surg ; 44(2): 381-389, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31844944

RESUMO

PURPOSE: To compare two different frontalis sling approaches, tarsal fixation and orbicular muscle fixation, using silicone rod (FCI Ophthalmics, Marshfield Hills, MA, USA) in terms of postoperative upper eyelid contour in patients with poor levator muscle function. DESIGN: Retrospective, comparative, case series. METHODS: Ten eyes of seven patients who received frontalis sling surgery with orbicularis muscle fixation (group 1), eight eyes of seven patients who received frontalis sling surgery with tarsal fixation (group 2) and 30 eyes of 15 age and sex-matched healthy controls (control group) were included. Postoperative photographs of all the participants were taken in the primary gaze, and each photograph was viewed on a computer. The distance between the upper lid margin and pupillary center (MCD), nasal limbus (MND), and temporal limbus (MTD) was measured, respectively, using the ruler in Microsoft Paint Software and compared with each other for each participant. RESULTS: Both nasal, central and temporal margin distance values in group 1 and group 2 were significantly lower than those of the control group (p < 0.05 for all values). The ratio of MTD/MCD in the control group was significantly higher than group 1 (p = 0.04) besides the ratio of MND/MTD in the control group was significantly lower than group 1 (p = 0.01). DISCUSSION: Frontalis sling approach with tarsal fixation using silicone rod might provide improved cosmetic results including more symmetrical upper eyelid contour compared with orbicularis muscle fixation approach. Moreover, the novel measuring technique presented in the current study provides a simple and effective assessment of the upper lid contour in daily practice setting. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.


Assuntos
Blefaroplastia , Blefaroptose , Blefaroptose/cirurgia , Pálpebras/cirurgia , Humanos , Músculos Oculomotores/cirurgia , Período Pós-Operatório , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA