Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Biol Macromol ; 270(Pt 2): 132351, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38754679

RESUMO

A novel chitosan/sodium hyaluronate/iridium (CHI/SH/Ir) hydrogel nanocomposite with a unique microstructure containing vertically aligned pores is fabricated via an electrophoresis technique. The formation of orderly vertical pores in CHI/SH/Ir hydrogel nanocomposite is due to the confinement of hydrogen bubbles produced from the water electrolysis during electrophoresis that limits their lateral movement and coalescence. In a wet state, the diameter for the vertical pores is 600-700 µm. With a thickness of 500 µm, the CHI/SH/Ir hydrogel nanocomposite exhibits a porosity of 76.7 % and a water uptake of 350 %. Its tensile strength is almost doubled to 8.7 MPa, as compared to that of counterpart without the addition of iridium. In CHI/SH/Ir hydrogel nanocomposite, the iridium nanoparticles are homogeneously distributed with an average size of 3 nm. The CHI/SH/Ir electrophoresis suspension exhibits a negligible cytotoxicity. In cell migration test using the human keratinocytes HaCaT cells, the CHI/SH/Ir hydrogel nanocomposite reveals a relative migration of 122.15 ± 9.02 % (p < 0.001) as compared to the blank sample. The presence of vertically aligned pores with the use of SH and iridium nanoparticles indicates a promising opportunity in wound healing application.

2.
J Synchrotron Radiat ; 31(Pt 2): 252-259, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38241123

RESUMO

In this study, a combination of X-ray excited optical luminescence (XEOL), time-resolved XEOL (TR-XEOL) and the Hanbury-Brown and Twiss (HB-T) interferometer at the Taiwan Photon Source (TPS) 23A X-ray nanoprobe beamline for exploring quantum materials is demonstrated. On the basis of the excellent spatial resolution rendered using a nano-focused beam, emission distributions of artificial micro-diamonds can be obtained by XEOL maps, and featured emission peaks of a selected local area can be obtained by XEOL spectra. The hybrid bunch mode of the TPS not only provides a sufficiently high peak power density for experiments at each beamline but also permits high-quality temporal domain (∼200 ns) measurements for investigating luminescence dynamics. From TR-XEOL measurements, the decay lifetime of micro-diamonds is determined to be approximately 16 ns. Furthermore, the XEOL spectra of artificial micro-diamonds can be investigated by the HB-T interferometer to identify properties of single-photon sources. The unprecedented strategy of combining XEOL, TR-XEOL and the HB-T interferometer at the X-ray nanoprobe beamline will open new avenues with significant characterization abilities for unraveling the emission mechanisms of single-photon sources for quantum materials.

3.
Biomaterials ; 303: 122402, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37988898

RESUMO

Developing scalable vascularized and innervated tissue is a critical challenge for the successful clinical application of tissue-engineered constructs. Collagen hydrogels are extensively utilized in cell-mediated vascular network formation because of their naturally excellent biological properties. However, the substantial increase in hydrogel contraction induced by populated cells limits their long-term use. Previous studies attempted to mitigate this issue by concentrating collagen pre-polymer solutions or synthesizing covalently crosslinked collagen hydrogels. However, these methods only partially reduce hydrogel contraction while hindering blood vessel formation within the hydrogels. To address this challenge, we introduced additional support in the form of a supportive spacer to counteract the contraction forces of populated cells and prevent hydrogel contraction. This approach was found to promote cell spreading, resist hydrogel contraction, control hydrogel/tissue geometry, and even facilitate the engineering of functional blood vessels and host nerve growth in just one week. Subsequently, implanting these engineered tissues into muscle defect sites resulted in timely anastomosis with the host vasculature, leading to enhanced myogenesis, increased muscle innervation, and the restoration of injured muscle functionality. Overall, this innovative strategy expands the applicability of collagen hydrogels in fabricating large vascularized nerve tissue constructs for repairing volumetric muscle loss (∼63 %) and restoring muscle function.


Assuntos
Hidrogéis , Tecido Nervoso , Engenharia Tecidual/métodos , Colágeno/farmacologia , Músculos
4.
J Synchrotron Radiat ; 29(Pt 3): 888-895, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35511022

RESUMO

An attenuator is generally used to decrease the power of an X-ray beam and prevent damage to detector sensors and other optical components. Therefore, attenuators are designed using foil or gas to absorb light source power. In this project, a large aperture and a water-cooling attenuator system are construed for the TPS 31A Projection X-ray Microscope and Transmission X-ray Microscope beamline. The source size of the wiggler is 300 µm × 7 µm on TPS 31A. The X-ray beam size at the sample position is 50 mm × 20 mm, located 49.5 m from the source. The light emission power is 1000 W in white-beam operation mode. The attenuator is needed to absorb energy for the light source and it has 12 foil carriers. The absorption foil size is 56 mm × 46 mm for the beam size across different beamline operation modes, and the cooling capacity is greater than 1000 W. This study applies a magnetic coupling-type attenuator system with foil carrier cooling carried out by the side chamber walls without the feedthrough having water enter the chamber to solve the thermal dissipation issue.

5.
J Synchrotron Radiat ; 29(Pt 2): 456-461, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35254309

RESUMO

This study develops and successfully demonstrates visualization methods for the characterization of europium (Eu)-doped BaAl2O4 phosphors using X-ray nanoprobe techniques. X-ray fluorescence (XRF) mapping not only gives information on the elemental distributions but also clearly reveals the valence state distributions of the Eu2+ and Eu3+ ions. The accuracy of the estimated valence state distributions was examined by performing X-ray absorption spectroscopy (XAS) across the Eu L3-edge (6.977 keV). The X-ray excited optical luminescence (XEOL) spectra exhibit different emission lines in the selected local areas. Their corresponding emission distributions can be obtained via XEOL mapping. The emission properties can be understood through correlation analysis. The results demonstrate that the main contribution to the luminescence intensity of the Eu-doped BaAl2O4 comes from the Eu2+ activator and the emission intensity will not be influenced by the concentration of Eu2+ or Eu3+ ions. It is anticipated that X-ray nanoprobes will open new avenues with significant characterization ability for unravelling the emission mechanisms of phosphor materials.

6.
J Synchrotron Radiat ; 28(Pt 6): 1921-1926, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738947

RESUMO

X-ray ptychography, a technique based on scanning and processing of coherent diffraction patterns, is a non-destructive imaging technique with a high spatial resolution far beyond the focused beam size. Earlier demonstrations of hard X-ray ptychography at Taiwan Photon Source (TPS) using an in-house program successfully recorded the ptychographic diffraction patterns from a gold-made Siemens star as a test sample and retrieved the finest inner features of 25 nm. Ptychography was performed at two beamlines with different focusing optics: a pair of Kirkpatrick-Baez mirrors and a pair of nested Montel mirrors, for which the beam sizes on the focal planes were 3 µm and 200 nm and the photon energies were from 5.1 keV to 9 keV. The retrieved spatial resolutions are 20 nm to 11 nm determined by the 10-90% line-cut method and half-bit threshold of Fourier shell correlation. This article describes the experimental conditions and compensation methods, including position correction, mixture state-of-probe, and probe extension methods, of the aforementioned experiments. The discussions will highlight the criteria of ptychographic experiments at TPS as well as the opportunity to characterize beamlines by measuring factors such as the drift or instability of beams or stages and the coherence of beams. Besides, probe functions, the full complex fields illuminated on samples, can be recovered simultaneously using ptychography. Theoretically, the wavefield at any arbitrary position can be estimated from one recovered probe function undergoing wave-propagating. The verification of probe-propagating has been carried out by comparing the probe functions obtained by ptychography and undergoing wave-propagating located at 0, 500 and 1000 µm relative to the focal plane.

7.
J Synchrotron Radiat ; 27(Pt 1): 217-221, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31868755

RESUMO

Time-resolved X-ray excited optical luminescence (TR-XEOL) was developed successfully for the 23A X-ray nanoprobe beamline located at the Taiwan Photon Source (TPS). The advantages of the TR-XEOL facility include (i) a nano-focused X-ray beam (<60 nm) with excellent spatial resolution and (ii) a streak camera that can simultaneously record the XEOL spectrum and decay time. Three time spans, including normal (30 ps to 2 ns), hybrid (30 ps to 310 ns) and single (30 ps to 1.72 µs) bunch modes, are available at the TPS, which can fulfil different experimental conditions involving samples with various lifetimes. It is anticipated that TR-XEOL at the TPS X-ray nanoprobe could provide great characterization capabilities for investigating the dynamics of photonic materials.

8.
Rev Sci Instrum ; 90(2): 021716, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30831705

RESUMO

To achieve an ultrahigh resolution of a beamline for soft X-rays at the Taiwan Photon Source (TPS), the profile of a highly precise grating is required at various curvatures. The slope error could be decreased to 0.1 µrad (rms) at a thermal load with a specially designed bender having 25 actuators. In the meantime, a long-trace profiler (LTP) was developed in situ to monitor the grating profile under a thermal load; it consists of a moving optical head, an air-bearing slide, an adjustable stand, and a glass viewport on the vacuum chamber. In the design of this system, a test chamber with an interior mirror was designed to simulate the chamber in the beamline. To prevent an error induced from a commercial viewport, a precision glass viewport (150CF, flatness 1/150 λ rms at 632.8 nm) was designed. The error induced from the slope error of the glass surface and the vacuum deformation was also simulated. The performance of the optical head of the LTP in situ (ISLTP) has been tested in the metrology laboratory. The sources of error of this LTP including the linearity and the glass viewport were corrected after the measurement. For the beamline measurement, an optical head was mounted outside the vacuum chamber; the measuring beam passed through the glass viewport to measure the grating profile in vacuum. The measurement of the LTP after correction of the above errors yielded a precision about 0.2 µrad (rms). In a preliminary test, an ISLTP was used to measure the grating profile at soft X-ray beamline TPS45A. The measured profile was for the bending mechanism to optimize the slope profile. From the measured energy spectrum, the slope error of the grating was estimated with software for optical simulation to be about 0.3 µrad (rms), consistent with our estimate of the ISLTP. In the future, it will be used to monitor the thermal bump under a large thermal load. In addition, an ISLTP was used to monitor the properties of optical elements-the twist and radius in the beamline during the installation phase.

9.
Sci Rep ; 9(1): 207, 2019 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-30659221

RESUMO

The multifunctional hard X-ray nanoprobe at Taiwan Photon Source (TPS) exhibits the excellent ability to simultaneously characterize the X-ray absorption, X-ray excited optical luminescence (XEOL) as well as the dynamics of XEOL of materials. Combining the scanning electron microscope (SEM) into the TPS 23A end-station, we can easily and quickly measure the optical properties to map out the morphology of a ZnO microrod. A special phenomenon has been observed that the oscillations in the XEOL associated with the confinement of the optical photons in the single ZnO microrod shows dramatical increase while the X-ray excitation energy is set across the Zn K-edge. Besides having the nano-scale spatial resolution, the synchrotron source also gives a good temporal domain measurement to investigate the luminescence dynamic process. The decay lifetimes of different emission wavelengths and can be simultaneously obtained from the streak image. Besides, SEM can provide the cathodoluminescence (CL) to be a complementary method to analyze the emission properties of materials, we anticipate that the X-ray nanoprobe will open new avenues with great characterization ability for developing nano/microsized optoelectronic devices.

10.
Opt Express ; 26(3): 2731-2739, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29401809

RESUMO

Polarization-dependent hard X-ray excited optical luminescence (XEOL) was used to study not only the optical properties but also the crystallographic orientations of a non-polar a-plane ZnO wafer. In addition to a positive-edge jump and extra oscillations in the near-band-edge (NBE) XEOL yield, we observed a blue shift of the NBE emission peak that follows the polarization-dependent X-ray absorption near-edge structure (XANES) as the X-ray energy is tuned across the Zn K-edge. This NBE blue shift is caused by the larger X-ray absorption, generating higher free carriers to reduce the exciton-LO phonon coupling, which causes a decrease in the exciton activation energy. The extra oscillations in XANES and XEOL as the polarization is set parallel to the c-axis is attributed to simultaneous excitations of the Zn 4p - O 2pπ -bond along the c-axis and the bilayer σ-bond, whereas only the σ-bond is excited when the polarization is perpendicular to the c-axis. The polarization-dependent XEOL spectra can be used to determine the crystallographic orientations.

11.
Sci Rep ; 7(1): 3691, 2017 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-28623319

RESUMO

X-ray 3D tomographic techniques are powerful tools for investigating the morphology and internal structures of specimens. A common strategy for obtaining 3D tomography is to capture a series of 2D projections from different X-ray illumination angles of specimens mounted on a finely calibrated rotational stage. However, the reconstruction quality of 3D tomography relies on the precision and stability of the rotational stage, i.e. the accurate alignment of the 2D projections in the correct three-dimensional positions. This is a crucial problem for nano-tomographic techniques due to the non-negligible mechanical imperfection of the rotational stages at the nanometer level which significantly degrades the spatial resolution of reconstructed 3-D tomography. Even when using an X-ray micro-CT with a highly stabilized rotational stage, thermal effects caused by the CT system are not negligible and may cause sample drift. Here, we propose a markerless image auto-alignment algorithm based on an iterative method. This algorithm reduces the traditional projection matching method into two simplified matching problems and it is much faster and more reliable than traditional methods. This algorithm can greatly decrease hardware requirements for both nano-tomography and data processing and can be easily applied to other tomographic techniques, such as X-ray micro-CT and electron tomography.

13.
Sci Rep ; 6: 34879, 2016 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-27748356

RESUMO

Mast cells play an important role in allergic responses. During activation, these cells undergo degranulation, a process by which various kinds of mediators stored in the granules are released. Granule homeostasis in mast cells has mainly been studied by electron microscopy (EM), where the fine structures of subcellular organelles are partially destroyed during sample preparation. Migration and fusion of granules have not been studied in detail in three dimensions (3D) in unmodified samples. Here, we utilized soft X-ray tomography (SXT) coupled with fluorescence microscopy to study the detailed structures of organelles during mast cell activation. We observed granule fission, granule fusion to plasma membranes, and small vesicles budding from granules. We also detected lipid droplets, which became larger and more numerous as mast cells were activated. We observed dramatic morphological changes of mitochondria in activated mast cells and 3D-reconstruction revealed the highly folded cristae inner membrane, features of functionally active mitochondria. We also observed giant vesicles containing granules, mitochondria, and lipid droplets, which we designated as granule-containing vesicles (GCVs) and verified their presence by EM in samples prepared by cryo-substitution, albeit with a less clear morphology. Thus, our studies using SXT provide significant insights into mast cell activation at the organelle level.


Assuntos
Anafilaxia/imunologia , Grânulos Citoplasmáticos/ultraestrutura , Mastócitos/ultraestrutura , Mitocôndrias/ultraestrutura , Tomografia por Raios X/métodos , Animais , Degranulação Celular , Linhagem Celular , Espaço Intracelular , Microscopia Eletrônica , Nanotecnologia , Ratos
14.
Nanotechnology ; 19(39): 395302, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21832591

RESUMO

The fabrication of devices to focus hard x-rays is one of the most difficult-and important-challenges in nanotechnology. Here we show that Fresnel zone plates combining 30 nm external zones and a high aspect ratio finally bring hard x-ray microscopy beyond the 30 nm Rayleigh spatial resolution level and measurable spatial frequencies down to 20-23 nm feature size. After presenting the overall nanofabrication process and the characterization test results, we discuss the potential research impact of these resolution levels.

15.
J Synchrotron Radiat ; 14(Pt 4): 320-5, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17587656

RESUMO

Using a superconducting-wavelength-shifter X-ray source with a photon flux density of 10(11)-10(13) photons s(-1) mrad(-1) (0.1% bandwidth)(-1) (200 mA)(-1) in the energy range 5-35 keV, three hard X-ray beamlines, BL01A, BL01B and BL01C, have been designed and constructed at the 1.5 GeV storage ring of the National Synchrotron Radiation Research Center (NSRRC). These have been designed for structure-related research using X-ray imaging, absorption, scattering and diffraction. The branch beamline BL01A, which has an unmonochromatized beam, is suitable for phase-contrast X-ray imaging with a spatial resolution of 1 microm and an imaging efficiency of one frame per 10 ms. The main beamline BL01B has 1:1 beam focusing and a medium energy resolution of approximately 10(-3). It has been designed for small-angle X-ray scattering and transmission X-ray microscopy, used, respectively, in anomalous scattering and nanophase-contrast imaging with 30 nm spatial resolution. Finally, the branch beamline BL01C, which features collimating and focusing mirrors and a double-crystal monochromator for a high energy resolution of approximately 10(-4), has been designed for X-ray absorption spectroscopy and high-resolution powder X-ray diffraction. These instruments, providing complementary tools for studying multiphase structures, have opened up a new research trend of integrated structural study at the NSRRC, especially in biology and materials. Examples illustrating the performances of the beamlines and the instruments installed are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA