Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JBMR Plus ; 8(3): ziad010, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38741607

RESUMO

Hypoparathyroidism (HypoPT) is a rare disease, often inadequately controlled by conventional treatment. PARALLAX was a mandatory post-marketing trial assessing pharmacokinetics and pharmacodynamics of different dosing regimens of recombinant human parathyroid hormone 1-84 (rhPTH[1-84]) for treating HypoPT. The present study (NCT03364738) was a phase 4, 1-yr open-label extension of PARALLAX. Patients received only 2 doses of rhPTH(1-84) in PARALLAX and were considered treatment-naive at the start of the current study. rhPTH(1-84) was initiated at 50 µg once daily, with doses adjusted based on albumin-corrected serum calcium levels. Albumin-corrected serum calcium (primary outcome measure), health-related quality of life (HRQoL), adverse events, and healthcare resource utilization (HCRU) were assessed. The mean age of the 22 patients included was 50.0 yr; 81.8% were women, and 90.9% were White. By the end of treatment (EOT), 95.5% of patients had albumin-corrected serum calcium values in the protocol-defined range of 1.88 mmol/L to the upper limit of normal. Serum phosphorus was within the healthy range, and albumin-corrected serum calcium-phosphorus product was below the upper healthy limit throughout, while mean 24-h urine calcium excretion decreased from baseline to EOT. Mean supplemental doses of calcium and active vitamin D were reduced from baseline to EOT (2402-855 mg/d and 0.8-0.2 µg/d, respectively). Mean serum bone turnover markers, bone-specific alkaline phosphatase, osteocalcin, procollagen type I N-terminal propeptide, and type I collagen C-telopeptide increased 2-5 fold from baseline to EOT. The HCRU, disease-related symptoms and impact on HRQoL improved numerically between baseline and EOT. Nine patients (40.9%) experienced treatment-related adverse events; no deaths were reported. Treatment with rhPTH(1-84) once daily for 1 yr improved HRQoL, maintained eucalcemia in 95% of patients, normalized serum phosphorus, and decreased urine calcium excretion. The effects observed on urine calcium and the safety profile are consistent with previous findings. Clinical trial identifier: NCT03364738.

2.
Endocr Pract ; 30(3): 200-208, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38086524

RESUMO

OBJECTIVE: Recombinant human parathyroid hormone (1-84) (rhPTH[1-84]) is efficacious in patients with hypoparathyroidism but additional data supporting its prolonged use are needed. We evaluated whether efficacy, safety, and tolerability are maintained during long-term rhPTH(1-84) treatment of patients with chronic hypoparathyroidism. METHODS: This was a phase 4, single-center, open-label, single-arm, 3-year extension (NCT02910466) of the phase 3 Hypo Extended (HEXT) study (NCT01199614). Patients self-administered rhPTH(1-84) once daily by subcutaneous injection, with doses individualized based on clinical parameters. Albumin-adjusted serum calcium levels (primary outcome measure), other disease biomarkers, health-related quality of life, and safety of rhPTH(1-84) were assessed using descriptive statistics. RESULTS: All patients (n = 39) had been exposed to rhPTH(1-84) (mean exposure [SD] 8.5 [3.5] years) before the start of the study, resulting in a mean exposure of 10.8 years including the present study. Mean patient age was 51.9 years, 79.5% were female, and 97.4% were White. Mean albumin-adjusted serum calcium concentrations were within the target range, and mean serum phosphate, serum calcium-phosphate product, and 24-hour urinary calcium excretion levels were within reference ranges at end of treatment. Mean doses of supplemental calcium and active vitamin D were maintained throughout the study. Bone turnover marker levels were maintained from baseline to end of treatment. No clinically relevant changes in bone mineral density were observed. Patient-reported health-related quality-of-life scores were generally maintained throughout the study. Four adverse events were considered treatment related and no new safety signals were identified. CONCLUSION: The effects of rhPTH(1-84) on biochemical, skeletal, and health-related quality-of-life parameters did not wane with extended use.


Assuntos
Cálcio , Hipoparatireoidismo , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Cálcio/uso terapêutico , Qualidade de Vida , Hormônio Paratireóideo/uso terapêutico , Hipoparatireoidismo/tratamento farmacológico , Proteínas Recombinantes/efeitos adversos , Fosfatos/uso terapêutico , Albuminas/uso terapêutico
3.
J Endocr Soc ; 7(5): bvad043, 2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-37091306

RESUMO

Context: Chronic hypoparathyroidism is conventionally treated with oral calcium and active vitamin D to reach and maintain targeted serum calcium and phosphorus levels, but some patients remain inadequately controlled. Objective: To assess long-term safety and efficacy of recombinant human parathyroid hormone (1-84) (rhPTH(1-84)) treatment. Methods: This was an open-label extension study at 12 US centers. Adults (n = 49) with chronic hypoparathyroidism were included. The intervention was rhPTH(1-84) for 6 years. The main outcome measures were safety, biochemical measures, oral supplement doses, bone indices. Results: Thirty-eight patients (77.6%) completed the study. Throughout 72 months, mean albumin-adjusted serum calcium was within 2.00 to 2.25 mmol/L (8.0-9.0 mg/dL). At baseline, 65% of patients with measurements (n = 24/37) were hypercalciuric; of these, 54% (n = 13/24) were normocalciuric at month 72. Mean serum phosphorus declined from 1.6 ± 0.19 mmol/L at baseline (n = 49) to 1.3 ± 0.20 mmol/L at month 72 (n = 36). Mean estimated glomerular filtration rate was stable. rhPTH(1-84)-related adverse events were reported in 51.0% of patients (n = 25/49); all but 1 event were mild/moderate in severity. Mean oral calcium supplementation reduced by 45% ± 113.6% and calcitriol by 74% ± 39.3%. Bone turnover markers declined by month 32 to a plateau above pretreatment values; only aminoterminal propeptide of type 1 collagen remained outside the reference range. Mean bone mineral density z score fell at one-third radius and was stable at other sites. Conclusion: 6 years of rhPTH(1-84) treatment was associated with sustained improvements in biochemical parameters, a reduction in the percentage of patients with hypercalciuria, stable renal function, and decreased supplement requirements. rhPTH(1-84) was well tolerated; no new safety signals were identified.

4.
Orphanet J Rare Dis ; 17(1): 186, 2022 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-35526036

RESUMO

BACKGROUND: Design and analysis of clinical trials for rare and ultra-rare disease pose unique challenges to the practitioners. Meeting conventional power requirements is infeasible for diseases where sample sizes are inherently very small. Moreover, rare disease populations are generally heterogeneous and widely dispersed, which complicates study enrollment and design. Leveraging all available information in rare and ultra-rare disease trials can improve both drug development and informed decision-making processes. MAIN TEXT: Bayesian statistics provides a formal framework for combining all relevant information at all stages of the clinical trial, including trial design, execution, and analysis. This manuscript provides an overview of different Bayesian methods applicable to clinical trials in rare disease. We present real or hypothetical case studies that address the key needs of rare disease drug development highlighting several specific Bayesian examples of clinical trials. Advantages and hurdles of these approaches are discussed in detail. In addition, we emphasize the practical and regulatory aspects in the context of real-life applications. CONCLUSION: The use of innovative trial designs such as master protocols and complex adaptive designs in conjunction with a Bayesian approach may help to reduce sample size, select the correct treatment and population, and accurately and reliably assess the treatment effect in the rare disease setting.


Assuntos
Doenças Raras , Projetos de Pesquisa , Teorema de Bayes , Desenvolvimento de Medicamentos , Humanos , Doenças Raras/tratamento farmacológico , Tamanho da Amostra
5.
PLoS One ; 10(4): e0123946, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25880806

RESUMO

Cervical cancer remains the third most frequently diagnosed and fourth leading cause of cancer death in women worldwide. We sought to develop a micro-RNA signature that was prognostic for disease-free survival, which could potentially allow tailoring of treatment for cervical cancer patients. A candidate prognostic 9-micro-RNA signature set was identified in the training set of 79 frozen specimens. However, three different approaches to validate this signature in an independent cohort of 87 patients with formalin-fixed paraffin-embedded (FFPE) specimens, were unsuccessful. There are several challenges and considerations associated with developing a prognostic micro-RNA signature for cervical cancer, namely: tumour heterogeneity, lack of concordance between frozen and FFPE specimens, and platform selection for global micro-RNA expression profiling in this disease. Our observations provide an important cautionary tale for future miRNA signature studies for cervical cancer, which can also be potentially applicable to miRNA profiling studies involving other types of human malignancies.


Assuntos
Regulação Neoplásica da Expressão Gênica , MicroRNAs/genética , Neoplasias do Colo do Útero/genética , Neoplasias do Colo do Útero/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Perfilação da Expressão Gênica/métodos , Humanos , Pessoa de Meia-Idade , Inclusão em Parafina , Prognóstico , Reprodutibilidade dos Testes , Neoplasias do Colo do Útero/patologia , Adulto Jovem
6.
Bioinformatics ; 28(11): 1546-8, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22513995

RESUMO

MOTIVATION: The NanoString nCounter Platform is a new and promising technology for measuring nucleic acid abundances. It has several advantages over PCR-based techniques, including avoidance of amplification, direct sequence interrogation and digital detection for absolute quantification. These features minimize aspects of experimental error and hold promise for dealing with challenging experimental conditions such as archival formalin-fixed paraffin-embedded samples. However, systematic inter-sample technical artifacts caused by variability in sample preservation, bio-molecular extraction and platform fluctuations must be removed to ensure robust data. RESULTS: To facilitate this process and to address these issues for NanoString datasets, we have written a pre-processing package called NanoStringNorm in the R statistical language. Key features include an extensible environment for method comparison and new algorithm development, integrated gene and sample diagnostics, and facilitated downstream statistical analysis. The package is open-source, is available through the CRAN package repository, includes unit-tests to ensure numerical accuracy, and provides visual and numeric diagnostics. AVAILABILITY: http://cran.r-project.org/web/packages/NanoStringNorm


Assuntos
Algoritmos , MicroRNAs/análise , Nanotecnologia/métodos , RNA Mensageiro/análise , Software , Nanotecnologia/instrumentação , Inclusão em Parafina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA