RESUMO
We report the case of a 65-year-old woman whose colonoscopy revealed a soft submucosal tumor approximately 7 cm in diameter in the ascending colon with an overlying flat lesion. The tumor was diagnosed as a lipoma with an overlying adenoma. Endoscopic submucosal dissection (ESD) was performed. Pathological examination revealed that the epithelium was a low-grade tubulovillous adenoma, while the submucosal yellow tumor was a lipoma. ESD appears to be a safe and effective treatment for colorectal lipomas overlying lipomas with colorectal adenomas.
RESUMO
OBJECTIVES: This prospective multicenter study aimed to assess and compare the accuracy of tissue harmonic endoscopic ultrasonography (TH-EUS) and contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for differentiating pancreatic carcinoma from other pancreatic tumors. METHODS: Consecutive patients with solid pancreatic tumors were prospectively enrolled between August 2013 and December 2014. To assess the accuracy of TH-EUS and CH-EUS, we compared four parameters of TH-EUS (fuzzy edge, irregular periphery, hypoechogenicity, and heterogeneous internal echogenicity) and four parameters of CH-EUS (hypoenhancement and heterogeneous enhancement in the early and late phases, respectively) to investigate which parameter of each method was most suitable to diagnose pancreatic carcinomas. Interobserver agreement and the diagnostic ability of pancreatic carcinoma using TH-EUS and CH-EUS were assessed and compared. RESULTS: A total of 204 patients were enrolled. For the diagnosis of pancreatic carcinoma, interobserver agreement by experts and nonexperts was 0.33-0.50 and 0.35-0.50 for TH-EUS, respectively, and 0.72-0.74 and 0.20-0.54 for CH-EUS, respectively. Irregular periphery was the most accurate diagnostic parameter among TH-EUS findings for differentiating pancreatic carcinomas, with sensitivity, specificity, and accuracy of 95.0%, 42.9%, and 78.9%, respectively. Late phase hypoenhancement was the most accurate diagnostic parameter among CH-EUS findings for differentiating pancreatic carcinomas, with sensitivity, specificity, and accuracy of 90.8%, 74.6%, and 85.8%, respectively. The accuracy of CH-EUS (late phase hypoenhancement) for diagnosis of pancreatic carcinoma was significantly higher than that of TH-EUS (irregular periphery) (p < 0.001). CONCLUSION: In comparison with TH-EUS, CH-EUS increased the diagnostic ability and reproducibility for the diagnosis of pancreatic carcinoma. UMIN (000011124).
Assuntos
Endossonografia , Neoplasias Pancreáticas , Meios de Contraste , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Background and study aims Although colorectal endoscopic submucosal dissection (ESD) has enabled high en bloc resection rates regardless of tumor size, colorectal ESD is still a challenging procedure. We developed a novel device called the Nelaton Attachment, which allows endoscopists to manipulate the ESD knives using two fingers of their left hand while holding the endoscope with their right hand. We retrospectively investigated the efficacy and safety of the Nelaton Attachment for colorectal ESD. We compared efficacy and safety between Nelaton Attachment and non-Nelaton Attachment groups, and also conducted an ex vivo experiment to evaluate the effect of the Nelaton Attachment. Patients and methods We retrospectively reviewed 36 consecutive patients with 37 colorectal tumors who had undergone ESD at Kishiwada Tokushukai Hospital and Naritatomisato Tokushukai Hospital between April 2016 and September 2018. The Nelaton Attachment was used for 22 of the 37 colorectal ESDs. In the ex vivo experiment, endoscopists inserted and withdrew an ESD knife 2âcm using two fingers of their left hand with and without the Nelaton Attachment. Results Median procedure time was significantly shorter in the Nelaton Attachment group (38âmin [range 6â-â195 min]) compared to the non-Nelaton Attachment group (75âmin [range 17â-â198 min]; P â=â0.030). Median time to complete the ex vivo experiment five times was significantly faster with the Nelaton Attachment than without the Nelaton Attachment ( P â=â0.001). Conclusions Use of the Nelaton Attachment for colorectal ESD is feasible and safe, and may facilitate colorectal ESD procedures.