Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 5821, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38987530

RESUMO

We propose a compact wearable glove capable of estimating both the finger bone lengths and the joint angles of the wearer with a simple stretch-based sensing mechanism. The soft sensing glove is designed to easily stretch and to be one-size-fits-all, both measuring the size of the hand and estimating the finger joint motions of the thumb, index, and middle fingers. The system was calibrated and evaluated using comprehensive hand motion data that reflect the extensive range of natural human hand motions and various anatomical structures. The data were collected with a custom motion-capture setup and transformed into the joint angles through our post-processing method. The glove system is capable of reconstructing arbitrary and even unconventional hand poses with accuracy and robustness, confirmed by evaluations on the estimation of bone lengths (mean error: 2.1 mm), joint angles (mean error: 4.16°), and fingertip positions (mean 3D error: 4.02 mm), and on overall hand pose reconstructions in various applications. The proposed glove allows us to take advantage of the dexterity of the human hand with potential applications, including but not limited to teleoperation of anthropomorphic robot hands or surgical robots, virtual and augmented reality, and collection of human motion data.


Assuntos
Dedos , Mãos , Dispositivos Eletrônicos Vestíveis , Humanos , Mãos/fisiologia , Dedos/fisiologia , Articulações dos Dedos/fisiologia , Movimento/fisiologia , Fenômenos Biomecânicos , Amplitude de Movimento Articular/fisiologia
2.
Front Psychiatry ; 15: 1364930, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39035603

RESUMO

We investigated the relationship between individuals' mental health traits and the characteristics of YouTube videos they watch. The mental health traits considered were stress, depression, anxiety, and self-esteem, which were measured using a survey questionnaire. We considered violence shown in a video, brightness and saturation of a video as video characteristics. We utilized the viewing history log data of the participants and analyzed the videos they watched on YouTube using computer vision techniques based on deep learning algorithms. The results revealed that viewers' consumption of violent videos was positively related to stress, depression, and anxiety, but negatively related to self-esteem. Individuals with higher levels of stress, depression, or anxiety tended to view darker videos than those with lower levels of stress, depression, or anxiety.

3.
Metabolites ; 13(2)2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36837796

RESUMO

Autism is a neurodevelopmental disorder for which the cause and treatment have yet not been determined. The polyunsaturated fatty acid (PUFA) levels change rapidly in the blood or cerebrospinal fluid of autistic children and PUFAs are closely related to autism spectrum disorder (ASD). This finding suggests that changes in lipid metabolism are associated with ASD and result in an altered distribution of phospholipids in cell membranes. To further understand ASD, it is necessary to analyze phospholipids in organs consisting of nerve cells, such as the brain. In this study, we investigated the phospholipid distribution in the brain tissue of valproic acid-induced autistic mice using matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Phospholipids including phosphatidylcholine, phosphatidylethanolamine, and phosphatidylserine were identified in each brain region and exhibited differences between the ASD and control groups. These phospholipids contain docosahexaenoic acid and arachidonic acid, which are important PUFAs for cell signaling and brain growth. We expect that the differences in phospholipids identified in the brain tissue of the ASD model with MALDI-MSI, in conjunction with conventional biological fluid analysis, will help to better understand changes in lipid metabolism in ASD.

4.
Adv Mater ; 34(19): e2108586, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35245965

RESUMO

Recent growing pursuit of skin-mountable devices has been impeded by the complicated structures of most sensing systems, containing electrode grids, stacked multilayers, and even external power sources. Here, a type of touch sensing, termed "triboresistive touch sensing", is introduced for gridless touch recognition based on monolayered ionic power generators. A homogeneous monolayer, i.e., ionic poly(dimethylsiloxane) (PDMS), generates electricity based on the electric field generated by touch. Voltages generated at each corner of the ionic PDMS rely on resistance between touch points and each corner, ensuring recognition of the touch positions without the need for electrode grid layers and external power sources. With notable advantages of high transparency (96.5%), stretchability (539.1%), and resilience (99.0%) of the ionic PDMS, epidermal triboresistive sensing is demonstrated to express touch position and readily play a musical instrument. A gridless system of triboresistive sensing allows rearrangement of the touch sections according to a given situation without any physical modification, and thus easily completes consecutive missions of controlling position, orientation, and gripping functions of a robot.

5.
J Am Soc Mass Spectrom ; 32(10): 2536-2545, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34448582

RESUMO

Amyotrophic lateral sclerosis (ALS) is a degenerative disease caused by motor neuron damage in the central nervous system, and it is difficult to diagnose early. Drosophila melanogaster is widely used to investigate disease mechanisms and discover biomarkers because it is easy to induce disease in Drosophila through genetic engineering. We performed matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) to investigate changes in phospholipid distribution in the brain tissue of an ALS-induced Drosophila model. Fly brain tissues of several hundred micrometers or less were sampled using a fly collar to obtain reproducible tissue sections of similar sizes. MSI of brain tissues of Drosophila cultured for 1 or 10 days showed that the distribution of phospholipids, including phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidic acid (PA), phosphatidylserine (PS), and phosphatidylinositol (PI), was significantly different between the control group and the ALS group. In addition, the lipid profile according to phospholipids differed as the culture time increased from 1 to 10 days. These results suggest that disease indicators based on lipid metabolites can be discovered by performing MALDI-MSI on very small brain tissue samples from the Drosophila disease model to ultimately assess the phospholipid changes that occur in early-stage ALS.


Assuntos
Esclerose Lateral Amiotrófica/metabolismo , Imagem Molecular/métodos , Fosfolipídeos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Química Encefálica/fisiologia , Modelos Animais de Doenças , Drosophila melanogaster , Fosfolipídeos/análise , Fosfolipídeos/química
6.
Lab Chip ; 21(15): 2997-3003, 2021 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-34156050

RESUMO

We demonstrate a platform technology for transferring opal films and photonic gel films to flexible substrates. The conventional fabrication procedure for inverse opal photonic gel (IOPG) sensors comprises three major steps: 1) the self-assembly of polystyrene µ-spheres to an opal template film within a channel between the top and bottom substrates, 2) infiltration and photo-polymerisation of the monomer mixture, and 3) etching of the opal template. Owing to the low processing yield of the first step, it is difficult to fabricate multiple sensor arrays on a single substrate. In this study, an opal film is formed between two substrates with different surface polarities, and the film is separated by disassembling the two substrates. The opal film on a medium polar substrate is covered using a flexible polyethylene terephthalate (PET) film, and opal-templated photo-polymerisation is performed. Finally, the photonic gel with the opal template is transferred to the PET film, and the opal template is etched out. Using the platform technique, the fabrications of pH-responsive IOPG and temperature-responsive IOPG sensors on PET films are respectively demonstrated. In addition, the IOPG containing the copolymer of acrylamide and 3-acrylamidophenylboronic acid was found to be responsive to glucose at physiological pH. All three sensors were fabricated using the same transfer method, differing only in the composition of monomer mixtures, and they all showed excellent sensitivity and repeatability on PET substrates. Due to the advantageous feature of the transfer method, dual sensors of pH-responsive IOPG and temperature-responsive IOPG were sequentially fabricated on a single PET film.


Assuntos
Coloides , Fótons , Óptica e Fotônica , Polimerização , Polímeros
7.
Biointerphases ; 15(2): 021011, 2020 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-32290664

RESUMO

Since Ar-gas cluster ion beams (Ar-GCIBs) have been introduced into time-of-flight secondary ion mass spectrometry (ToF-SIMS), there have been various attempts to analyze organic materials and biomolecules that require low-damage analysis and high sensitivity, because Ar-GCIBs allow soft ionization of large molecules such as peptides and proteins due to the low energy per atom. Here, the authors adopted the Ar-GCIB as a primary beam to detect proteins including human insulin, ubiquitin, and cytochrome C (molecular weights are 5808, 8564, and 12 327 Da, respectively). They have confirmed that the detection of the intact proteins was possible when the Ar-GCIB was used as a primary ion beam. In addition, they successfully identified each protein by analyzing the trypsin-digested peptides in myoglobin, cytochrome C, and bovine serum albumin. They also attempted on-surface enzymatic digestion to identify proteins on the surface of the Si wafer and obtained results identical to those of in-solution digestion. It is expected that the authors' on-surface digestion method can enable the application of ToF-SIMS for the analysis of proteins present in biological tissues.


Assuntos
Argônio/química , Peptídeos/análise , Proteínas/análise , Espectrometria de Massa de Íon Secundário , Animais , Bovinos , Bases de Dados de Proteínas , Humanos , Íons , Soluções
8.
Anal Chem ; 91(22): 14719-14727, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31621295

RESUMO

In this work, medical diagnosis of sepsis was conducted via quantitative analysis of lysophosphatidylcholine 16:0 (LPC 16:0) by using matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry based on a parylene-matrix chip. In the first step, specific mass peaks for the diagnosis of sepsis were searched by comparing MALDI-TOF mass spectra of sepsis patient sera with healthy controls and pneumonia patient sera. Two mass peaks at m/z = 496.3 and 518.3 were chosen as those that are specifically different for sepsis sera to compare with healthy controls and pneumonia patient sera. These mass peaks were identified to be protonated and sodium adducts of LPC 16:0 by using tandem mass spectra (MS2 and MS3) of purely synthesized LPC 16:0 and extracted LPC 16:0 from a healthy control and a sepsis patient. In the next step, a standard curve for LPC 16:0 for the quantitative analysis of LPC 16:0 with MALDI-TOF MS based on the parylene-matrix chip was prepared, and the statistical correlation to the LC-MS analysis results was demonstrated by using the Bland-Altman test and Passing-Bablok regression. Finally, MALDI-TOF MS based on the parylene-matrix chip was used for the quantification of LPC 16:0 with sera from patients with severe sepsis and septic shock (n = 143), pneumonia patients (n = 12), and healthy sera (n = 31). The sensitivity and the selectivity of medical diagnosis of sepsis was estimated to be 97.9% and 95.5% by using MALDI-TOF MS based on the parylene-matrix chip, respectively.


Assuntos
Lisofosfatidilcolinas/sangue , Polímeros/química , Sepse/diagnóstico , Xilenos/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
9.
Nano Converg ; 5(1): 24, 2018 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-30467706

RESUMO

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging is an analytical technique rapidly expanding in use in biological studies. This technique is based on high spatial resolution (50-100 nm), high surface sensitivity (1-2 nm top-layer), and statistical analytic power. In mass spectrometry imaging (MSI), sample preparation is a crucial step to maintaining the natural state of the biomolecules and providing accurate spatial information. However, a number of problems associated with temperature changes in tissue samples such as loss of original distribution due to undesired molecular migration during the sample preparation or reduced ionization efficiency make it difficult to accurately perform MSI. Although frozen hydrate analysis is the ideal sample preparation method to eliminate the effects of temperature, this approach is hindered by mechanical limitations. Alternatively, an adhesive-tape-supported mounting and freeze-drying preparation has been proposed. This paper provides a concise review of the sample preparation procedures, a review of current issues, and proposes efficacious solutions for ToF-SIMS imaging in biological research.

10.
J Am Soc Mass Spectrom ; 29(12): 2333-2340, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30238193

RESUMO

Although the low temperature plasma mass spectrometry (LTP-MS) is widely used as an analysis tool for many biochemical samples, its application window is somehow limited to the analytes of low molecular mass and high volatility. For this reason, there have been attempts to enhance the ionization/desorption efficiencies with extra heating, for instance. In this study, another enhancement method was suggested using the photocatalytic nano-particles (NPs). In order to assess the NP effects on the LTP-MS, two fatty acid ethyl ester samples of ethyl myristate and ethyl palmitate were used, and the NP of titanium dioxide (TiO2) was mainly employed. The results showed that the signal intensities of the LTP-MS were largely increased with the TiO2 addition for both samples. In addition, the cholesterol sample was analyzed using the TiO2 assisted LTP-MS, also resulting in the enhancement of the signal intensity. The overall results inferred that the photocatalytic NP confirmed its role as an effective assist tool for the LTP-MS, especially suitable because of the facile method and the heat-free nature. Graphical Abstract ᅟ.

11.
Biointerphases ; 13(3): 03B411, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29495661

RESUMO

Brain imaging using time-of-flight secondary ion mass spectrometry (ToF-SIMS) has been reported to produce the distorted biomolecular distributions due to the cholesterol-induced matrix effect when cholesterol migrates to the surface, particularly in white matter, which contains a high level of cholesterol. Frozen-hydrated analysis has been used to inhibit the movement of cholesterol in the brain. In this paper, the authors propose new sample preparation and drying methods that can be used to obtain accurate biomolecular images at room temperature, instead of frozen-hydrated analysis using liquid-nitrogen, which must be continuously supplied to maintain the sample at -160 °C during the experiment. The rat brain prepared by the tape-supporting method on a precooled (-20 °C) stainless steel plate was freeze-dried in a load-lock chamber of ToF-SIMS for about an hour and moved directly to the main chamber. Using this preparation method, the authors found that cholesterol did not migrate to the surface in the corpus callosum (white matter) of the rat brain and sulfatide-related signals obtained from the cerebellum were not reduced in white matter. Our tape-supporting and freeze-drying sampling method for brain tissues could be a useful tool to study important metabolites of neurodegenerative diseases.


Assuntos
Química Encefálica , Encéfalo/patologia , Liofilização , Técnicas de Preparação Histocitológica/métodos , Espectrometria de Massa de Íon Secundário/métodos , Animais , Colesterol/análise , Ratos , Sulfoglicoesfingolipídeos/análise
12.
J Am Soc Mass Spectrom ; 28(8): 1729-1732, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28508286

RESUMO

Corn seed tissue sections were prepared by the tape support method using an adhesive tape, and mass spectrometry imaging (MSI) was performed. The effect of heat generated during sample preparation was investigated by time-of-flight secondary mass spectrometry (TOF-SIMS) imaging of corn seed tissue prepared by the tape support and the thaw-mounted methods. Unlike thaw-mounted sample preparation, the tape support method does not cause imaging distortion because of the absence of heat, which can cause migration of the analytes on the sample. By applying the tape-support method, the corn seed tissue was prepared without structural damage and MSI with accurate spatial information of analytes was successfully performed. Graphical Abstract ᅟ.


Assuntos
Sementes/química , Espectrometria de Massa de Íon Secundário/métodos , Zea mays/química , Colina/análise , Desenho de Equipamento , Ácido Palmítico/análise , Fosforilcolina/análise , Sementes/embriologia , Espectrometria de Massa de Íon Secundário/instrumentação , Zea mays/embriologia
13.
Biointerphases ; 11(4): 041008, 2016 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-28006919

RESUMO

Lipid profiling in nine bacterial species has been accomplished by laser desorption ionization mass spectrometry (LDI-MS) using amorphous silicon (a-Si) thin film with 100 nm thickness. Lipid ions could be generated by LDI on a-Si regardless of ion acquisition modes because of a thermal property of a-Si to govern laser-induced surface heating. In a comparative study of lipid profiling in Bacillus lichemiformis by LDI-MS and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), LDI-MS on a-Si shows a higher efficiency in lipid and lipopeptide detection than MALDI-MS. A total of 53 peaks of lipid ions generated by LDI on a-Si in both acquisition modes for m/z 400-1200 was 1.6 times more than that detected by MALDI-MS using three organic matrices-2,5-dihydroxybenzoic acid, 1,5-diaminonaphthalene, and 2,4,6-trihydroxyacetophenone monohydrate. Also, the authors demonstrate by mass spectrometry imaging (MSI) that LDI-MS provides high detection coverage through whole sample area. MSI results show the detection yield in LDI on a-Si is 94.8% calculated by counting the number of points detected in the analyte ion signal in a whole spot. It means that reproducible detection of lipid ions by LDI-MS is possible even if laser is randomly irradiated at any position within the bacterial sample area applied on a-Si. Lipid profiling by LDI-MS on a-Si was applied to bacterial differentiation of nine bacterial species conducted by performing principal component analysis. Nine bacterial species are successfully distinguishable from each other by LDI-MS lipid profiling.


Assuntos
Bacillus/química , Lasers , Lipídeos/análise , Espectrometria de Massas/métodos , Silício
14.
J Phys Ther Sci ; 28(8): 2373-5, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27630435

RESUMO

[Purpose] The purpose of this study was to investigate the effect of isometric hip adduction and abduction on trunk muscle activity during plank exercises. [Subjects and Methods] Nineteen healthy male subjects were recruited for this study. All subjects performed the traditional plank exercise (TP), plank exercise with isometric hip adduction (PHAD), and plank exercise with isometric hip abduction (PHAB) by using an elastic band. Electromyographic (EMG) activities of the internal oblique (IO) and external oblique (EO) were measured during the 3 plank exercises by using an Electromyography system. [Results] Internal oblique and external oblique muscle activities were significantly greater during plank exercise with isometric hip adduction and plank exercise with isometric hip abduction than during traditional plank exercise. Internal oblique and external oblique muscle activities did not differ between the plank exercise with isometric hip adduction and plank exercise with isometric hip abduction conditions. [Conclusion] These findings demonstrate that loaded isometric hip movements may be a useful strategy to increase trunk muscle activity during plank exercises.

15.
Biointerphases ; 11(2): 02A321, 2016 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-26861497

RESUMO

The popularity of argon gas cluster ion beams (Ar-GCIB) as primary ion beams in time-of-flight secondary ion mass spectrometry (TOF-SIMS) has increased because the molecular ions of large organic- and biomolecules can be detected with less damage to the sample surfaces. However, Ar-GCIB is limited by poor mass resolution as well as poor mass accuracy. The inferior quality of the mass resolution in a TOF-SIMS spectrum obtained by using Ar-GCIB compared to the one obtained by a bismuth liquid metal cluster ion beam and others makes it difficult to identify unknown peaks because of the mass interference from the neighboring peaks. However, in this study, the authors demonstrate improved mass resolution in TOF-SIMS using Ar-GCIB through the delayed extraction of secondary ions, a method typically used in TOF mass spectrometry to increase mass resolution. As for poor mass accuracy, although mass calibration using internal peaks with low mass such as hydrogen and carbon is a common approach in TOF-SIMS, it is unsuited to the present study because of the disappearance of the low-mass peaks in the delayed extraction mode. To resolve this issue, external mass calibration, another regularly used method in TOF-MS, was adapted to enhance mass accuracy in the spectrum and image generated by TOF-SIMS using Ar-GCIB in the delayed extraction mode. By producing spectra analyses of a peptide mixture and bovine serum albumin protein digested with trypsin, along with image analyses of rat brain samples, the authors demonstrate for the first time the enhancement of mass resolution and mass accuracy for the purpose of analyzing large biomolecules in TOF-SIMS using Ar-GCIB through the use of delayed extraction and external mass calibration.


Assuntos
Imagem Óptica/métodos , Manejo de Espécimes/métodos , Espectrometria de Massa de Íon Secundário/métodos , Animais , Argônio , Química Encefálica , Bovinos , Gases , Ratos , Soroalbumina Bovina/química
16.
Mass Spectrom Rev ; 34(2): 94-115, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24863621

RESUMO

Insights on mechanisms for the generation of gas-phase peptide ions and their dissociation in matrix-assisted laser desorption ionization (MALDI) gained from the kinetic and ion yield studies are presented. Even though the time-resolved photodissociation technique was initially used to determine the dissociation kinetics of peptide ions and their effective temperature, it was replaced by a simpler method utilizing dissociation yields from in-source decay (ISD) and post-source decay (PSD). The ion yields for a matrix and a peptide were measured by repeatedly irradiating a region on a sample and collecting ion signals until the sample in the region was completely depleted. Matrix- and peptide-derived gas-phase cations were found to be generated by pre-formed ion emission or by ion-pair emission followed by anion loss, but not by laser-induced ionization. The total number of ions, that is, matrix plus peptide, was found to be equal to the number of ions emitted from a pure matrix. A matrix plume was found to cool as it expanded, from around 800-1,000 K to 400-500 K. Dissociation of peptide ions along b/y channels was found to occur statistically, that is, following RRKM behavior. Small critical energy (E0 = 0.6-0.7 eV) and highly negative critical entropy (ΔS(‡) = -30 to -25 eu) suggested that the transition structure was stabilized by multiple intramolecular interactions.


Assuntos
Gases/análise , Íons/química , Peptídeos/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Gases/química , Humanos , Cinética , Peptídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Temperatura , Termodinâmica
17.
Nucl Med Mol Imaging ; 47(1): 52-4, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24895508

RESUMO

The whole body I-131 scan is routinely performed in the postoperative treatment of patients with well-differentiated thyroid cancer. Accurate interpretation of whole body I-131 scan after thyroidectomy is critical to appropriate management of patients with thyroid cancer, to prevent unnecessary surgical removal or exposure to radioiodine. Unfortunately, false-positive uptakes in several other organs and their associated disease processes have been reported. We report a case of false-positive iodine uptake in the pelvic region with incidentally diagnosed mature cystic teratoma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA