Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Diabetes Investig ; 14(5): 648-658, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36729958

RESUMO

AIMS/INTRODUCTION: Glucagon, a peptide hormone produced from proglucagon, is involved in the pathophysiology of diabetes. Plasma glucagon levels are currently measured by sandwich enzyme-linked immunosorbent assay (ELISA), but the currently used sandwich ELISA cross-reacts with proglucagon-derived peptides, thereby providing incorrect results in subjects with elevated plasma proglucagon-derived peptide levels. We aimed to develop a more broadly reliable ELISA for measuring plasma glucagon levels. MATERIALS AND METHODS: A new sandwich ELISA was developed using newly generated monoclonal antibodies against glucagon. After its validation, plasma glucagon levels were measured with the new ELISA and the currently used ELISA in subjects who underwent laparoscopic sleeve gastrectomy (LSG) and in outpatients with suspected glucose intolerance. The ELISA results were compared with those from liquid chromatography-high resolution mass (LC-HRMS) analysis, which we previously established as the most accurate measuring system. RESULTS: The new ELISA has high specificity (<1% cross-reactivities) and high sensitivity (a lower range of 0.31 pmol/L). Plasma glucagon values in the subjects who underwent laparoscopic sleeve gastrectomy and some outpatients with suspected glucose intolerance differed between the new ELISA and the currently used ELISA. These subjects also showed markedly high plasma glicentin levels. Despite the elevated plasma glicentin levels, the new ELISA showed better positive correlation with LC-HRMS than did the currently used ELISA. CONCLUSIONS: The new ELISA enables more accurate measurement of plasma glucagon than the currently used ELISA, even in subjects with elevated proglucagon-derived peptide levels. It should be clinically useful in elucidating the pathophysiology of individual diabetic patients.


Assuntos
Diabetes Mellitus , Intolerância à Glucose , Hormônios Peptídicos , Humanos , Glucagon , Proglucagon , Glicentina , Intolerância à Glucose/diagnóstico , Glucose , Ensaio de Imunoadsorção Enzimática/métodos
2.
Acta Radiol ; 63(4): 458-466, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33709794

RESUMO

BACKGROUND: The low-tube-voltage scan generally needs a higher tube current than the conventional 120 kVp to maintain the image noise. In addition, the low-tube-voltage scan increases the photoelectric effect, which increases the radiation absorption in organs. PURPOSE: To compare the organ radiation dose caused by iodine contrast medium between low tube voltage with low contrast medium and that of conventional 120-kVp protocol with standard contrast medium. MATERIAL AND METHODS: After the propensity-matching analysis, 66 patients were enrolled including 33 patients with 120 kVp and 600 mgI/kg and 33 patients with 80 kVp and 300 mgI/kg (50% iodine reduction). The pre- and post-contrast phases were assessed in all patients. The Monte Carlo simulation tool was used to simulate the radiation dose. The computed tomography (CT) numbers for 10 organs and the organ doses were measured. The organ doses were normalized by the volume CT dose index, and the 120-kVp protocol was compared with the 80-kVp protocol. RESULTS: On contrast-enhanced CT, there were no significant differences in the mean CT numbers of the organs between 80-kVp and 120-kVp protocols except for the pancreas, kidneys, and small intestine. The normalized organ doses at 80 kVp were significantly lower than those of 120 kVp in all organs (e.g. liver, 1.6 vs. 1.9; pancreas, 1.5 vs. 1.8; spleen, 1.7 vs. 2.0) on contrast-enhanced CT. CONCLUSION: The low tube voltage with low-contrast-medium protocol significantly reduces organ doses at the same volume CT dose index setting compared with conventional 120-kVp protocol with standard contrast medium on contrast-enhanced CT.


Assuntos
Meios de Contraste , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/instrumentação , Imagem Corporal Total/métodos , Adulto , Feminino , Humanos , Iodo , Masculino , Pessoa de Meia-Idade
3.
Medicine (Baltimore) ; 100(51): e28351, 2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-34941146

RESUMO

ABSTRACT: We investigated the feasibility of non-contrast three-dimensional modified Dixon (mDixon) magnetic resonance angiography (MRA) to evaluate the carotid artery.We studied 30 normal patients who underwent non-contrast mDixon and conventional time-of-flight (TOF) MRA of the neck with a clinical 3T MR scanner. Carotid artery signal-to-noise ratio (SNR) and contrast-to-noise ratio were compared between mDixon-MRA and TOF-MRA. Two readers independently evaluated vessel sharpness, image contrast, and overall image quality using a 4-point scale.SNR was significantly higher on mDixon-MRA than TOF-MRA (P < .01). There was no significant difference in contrast-to-noise ratio. The visual score for vessel sharpness was significantly higher on mDixon-MRA than TOF-MRA (P < .01), whereas the score for contrast was significantly higher on TOF-MRA (P < .01).Although non-contrast three-dimensional mDixon-MRA showed lower visual contrast than conventional TOF-MRA, it provided images with significantly higher SNR and better vessel sharpness than TOF-MRA.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Pescoço/diagnóstico por imagem , Meios de Contraste , Humanos , Imageamento Tridimensional , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
4.
Clin Exp Nephrol ; 25(12): 1319-1328, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34255252

RESUMO

BACKGROUND: There are few reports on the significance for the combined evaluation of blood humoral factors and urinary biomarkers in terms of worsening renal function (WRF) after coronary angiography (CAG)/percutaneous coronary arterial intervention (PCI). METHOD AND RESULTS: Urinary liver type-fatty acid-binding protein (L-FABP), neutrophil gelatinase associated lipocalin (NGAL), and adrenomedullin (AM) were measured less than 24 h before and 3 h, 6 h, 1 day, and 2 days after CAG/PCI. WRF was defined as a > 20% decrease in the estimated GFR. WRF occurred in seven of 100 patients and the increase in L-FABP/creatinine (Cr) at 1 day after CAG/PCI was significantly higher in the WRF group than in the non-WRF group. Plasma B-type natriuretic peptide (BNP) before CAG/PCI and L-FABP/Cr at 1 day after CAG/PCI were independent predictors for WRF. The areas under the receiver-operating characteristic curves were as follows: 0.760 for BNP before CAG/PCI, 0.731 for L-FABP/Cr at 1 day after CAG/PCI, and 0.892 for BNP and L-FABP/Cr. Urinary AM levels after PCI/CAG were negatively correlated only to serum potassium levels. Gene expressions of AM and AM-receptor were detectable in renal tubule epithelial cells. AM increased intracellular second messenger levels in a dose-dependent manner. CONCLUSIONS: Our results suggest that combined evaluation of plasma BNP and urinary L-FABP/Cr is useful as a predictor of renal dysfunction in CAG/PCI patients.


Assuntos
Doença da Artéria Coronariana/terapia , Proteínas de Ligação a Ácido Graxo/urina , Taxa de Filtração Glomerular , Nefropatias/diagnóstico , Rim/fisiopatologia , Peptídeo Natriurético Encefálico/sangue , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Biomarcadores/urina , Células Cultivadas , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Creatinina/urina , Feminino , Humanos , Rim/metabolismo , Nefropatias/sangue , Nefropatias/fisiopatologia , Nefropatias/urina , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
5.
Biochem Biophys Res Commun ; 559: 197-202, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-33945998

RESUMO

Tachykinin-like peptides, such as substance P, neurokinin A, and neurokinin B, are among the earliest discovered and best-studied neuropeptide families, and research on them has contributed greatly to our understanding of the endocrine control of many physiological processes. However, there are still many orphan tachykinin receptor homologs for which cognate ligands have not yet been identified, especially in small invertebrates, such as the nematode Caenorhabditis elegans (C. elegans). We here show that the C. elegans nlp-58 gene encodes putative ligands for the orphan G protein-coupled receptor (GPCR) TKR-1, which is a worm ortholog of tachykinin receptors. We first determine, through an unbiased biochemical screen, that a peptide derived from the NLP-58 preprotein stimulates TKR-1. Three mature peptides that are predicted to be generated from NLP-58 show potent agonist activity against TKR-1. We designate these peptides as C. elegans tachykinin (CeTK)-1, -2, and -3. The CeTK peptides contain the C-terminal sequence GLR-amide, which is shared by tachykinin-like peptides in other invertebrate species. nlp-58 exhibits a strongly restricted expression pattern in several neurons, implying that CeTKs behave as neuropeptides. The discovery of CeTKs provides important information to aid our understanding of tachykinin-like peptides and their functional interaction with GPCRs.


Assuntos
Caenorhabditis elegans/metabolismo , Taquicininas/metabolismo , Sequência de Aminoácidos , Animais , Sequência de Bases , Células CHO , Cricetulus , Taquicininas/química , Taquicininas/genética , Taquicininas/isolamento & purificação
6.
Radiol Case Rep ; 15(8): 1261-1265, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32577143

RESUMO

Peliosis hepatis involves multiple blood-filled cystic spaces in the hepatic parenchyma. Using conventional imaging, distinguishing PH from other malignancies can be difficult. The findings of Peliosis hepatis on gadoxetic acid (Gd-EOB) enhanced magnetic resonance imaging are not well reported. Therefore, we report the imaging features of pathologically proven PH. On the hepatobiliary phase of Gd-EOB magnetic resonance imaging, most lesions showed unenhanced areas, but some lesions showed central enhancement "halo sign."

7.
Circ J ; 84(4): 636-641, 2020 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-32101814

RESUMO

BACKGROUND: The aim of this study was to evaluate the quality and diagnostic performance of virtual monochromatic images (VMI) obtained with dual-layer dual-energy computed tomography (DL-DECT) during indirect CT venography (CTV) for deep vein thrombosis (DVT).Methods and Results:This retrospective study was approved by the Institutional Review Board, which waived the requirement for informed consent. We retrospectively enrolled 45 patients who underwent CTV with DL-DECT, and VMI were retrospectively generated. We compared the venous attenuation, noise, contrast, and contrast-to-noise ratio (CNR) between VMI with the highest CNR and conventional CT on paired t-test. Furthermore, we compared the pooled area under the curve (AUC) of each technique with Delong's test in 34 patients who underwent color Doppler ultrasonography. The 40-keV VMI had the best CNR. The noise was significantly lower on 40-keV (9.7±2.5 HU) than on 120-kVp VMI (10.5±2.5 HU; P<0.01). The contrast (120 kVp, 38.2±15.3 HU vs. 40 keV, 131.6±43.6 HU) and CNR (120 kVp, 3.8±1.7 vs. 40 keV, 14.4±6.1) were significantly higher in 40-keV VMI than in 120-kVp VMI (P<0.01). Furthermore, the pooled AUC was significantly higher for 40-keV (0.84) than for 120-kVp VMI (0.78; P=0.03). CONCLUSIONS: In indirect CTV, 40-keV VMI obtained with DL-DECT offers better image quality and diagnostic performance for DVT than conventional CT.


Assuntos
Angiografia por Tomografia Computadorizada , Flebografia , Trombose Venosa/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia Doppler em Cores
8.
Acad Radiol ; 27(5): e116-e122, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31537504

RESUMO

RATIONALE AND OBJECTIVES: To compare the objective and subjective image qualities between single-energy computed tomography (CT) at 70 kVp and virtual monoenergetic imaging (VMI) of dual-source dual-energy CT for CT angiography with 180 mgI/kg. MATERIALS AND METHODS: Total 63 patients scanned with 180 mgI/kg were randomly divided into two groups: Group A (32 patients) underwent CT angiography at 70-kVp, and Group B (31 patients) underwent dual-energy CT. VMI sets were generated at 10-keV increments between 40 and 100 keV. We calculated aortic attenuation, contrast-to-noise-ratio (CNR), signal-to-noise-ratio, figure of merit of CNR, and effective dose for each protocol. Three radiologists scored overall image quality and various arteries' visibility using a four-point scale. Quantitative and qualitative comparisons between 70 kVp and VMI with the highest CNR were performed with the two-tailed t test or Kruskal-Wallis test. RESULTS: The 40-keV images offered the highest CNR among VMIs. Aortic attenuation at 70 kVp was significantly lower than that at 40 keV (p < 0.001). However, the signal-to-noise-ratio, CNR, and figure of merit of CNR were significantly higher at 70 kVp than those at 40-keV (p < 0.001, p < 0.05, and p < 0.05, respectively). The effective dose of each group was almost equal. The qualitative visibility scores for various arteries, except the ascending and upper-abdominal aorta, were also better at 70 kVp than those at 40 keV. CONCLUSION: Aortic attenuation at 70 kVp with 180 mg I/kg was lower than that of VMI at 40 keV, and the objective and subjective image qualities were higher at 70 kVp than those at 40 keV.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
9.
Jpn J Radiol ; 38(2): 144-153, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31863328

RESUMO

PURPOSE: In patients with suspected coronary artery disease (CAD), coexisting extracardiac abnormalities have a major impact on the patient management. This study aimed to evaluate the image quality of whole-body computed tomography (CT) immediately after the coronary computed tomography angiography (CTA) and investigate the incidence of extracardiac findings in patients with suspected CAD. MATERIALS AND METHODS: We enrolled 450 patients undergoing whole-body CT at 100 kVp and model-based iterative reconstruction immediately after the coronary CTA (Group A) and retrospectively reviewed 144 control patients who underwent conventional contrast-enhanced CT (120 kVp) with filtered back projection (Group B). We compared the signal-to-noise ratio (SNR) of the aorta and liver and radiation dose between the two groups. Then, we evaluated the prevalence of extracardiac findings in Group A. RESULTS: Compared with Group B, Group A demonstrated significantly higher aorta and liver SNR and lower radiation dose. In Group A, whole-body CT revealed 229 coexisting lesions in 165 patients, including 32 and 106 cases of oncologic and vascular diseases, respectively. CONCLUSION: Additional whole-body CT after coronary CTA may provide adequate image quality. Using additional whole-body CT, 36% of patients with suspected CAD had clinically relevant coexisting findings, including malignancy.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Imagem Corporal Total/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
10.
J Comput Assist Tomogr ; 43(3): 460-466, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31082952

RESUMO

OBJECTIVE: To evaluate the optimal virtual monochromatic energy in dual-energy computed tomography for differentiating between infarcted areas and normal brain parenchyma. METHODS: We enrolled 29 patients with middle cerebral artery acute brain infarction of who underwent examination by dual-energy computed tomography. We calculated the contrast-to-noise ratio (CNR) between white or gray matter and the infarcted area (CNR(W-I) and CNR(G-I), respectively) and normalized CNRs. From the normalized CNRs, we assessed which monochromatic energy gave the best balance between the infarcted area and normal brain parenchyma. The 70-keV images were used for comparison. RESULTS: The 99-keV images demonstrated the best balance between the infarction and normal brain parenchyma. In quantitative analysis, the 99-keV images were not inferior to the 70-keV images. (CNR(G-I), 1.92 ± 0.80 vs 2.00 ± 0.70, respectively [P = 0.16]; CNR(W-I), 0.52 ± 0.72 vs 0.40 ± 0.64, P < 0.01, respectively). CONCLUSIONS: Monochromatic 99-keV energy images may be optimal for evaluating middle cerebral artery acute brain infarction.


Assuntos
Infarto da Artéria Cerebral Média/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Infarto Cerebral/diagnóstico por imagem , Feminino , Substância Cinzenta , Humanos , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído , Substância Branca/diagnóstico por imagem
11.
Anticancer Res ; 38(5): 3089-3095, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29715145

RESUMO

Background/Aim: The sacrifice of a major hepatic vein can cause hepatic venous congestion (HVC). We evaluated the effects of HVC on regional liver function using the liver uptake value (LUV), that was calculated from 99m Tc-labeled-galactosyl-human-serum-albumin ( 99m Tc-GSA) single-photon emission computed tomography (SPECT) /contrast-enhanced computed tomography (CE-CT) fused images. Patients and Methods: Sixty-two patients underwent 99m Tc-GSA SPECT/CE-CT prior to hepatectomy for liver cancer and at 7 days after surgery were divided into groups with (n=8) and without HVC (n=54). In the HVC group, CT volume (CTv) and LUV were separately calculated in both congested and non-congested areas. Results: The remnant LUV/CTv of the HVC group was significantly smaller than that of the non-HVC group (p<0.01). The mean functional ratio was 0.47±0.05, and all ratios were ≥0.39. Conclusion: After hepatectomy with sacrifice of major hepatic vein, liver function per unit volume in the congested areas was approximately 40% of that in the non-congested areas.


Assuntos
Hepatectomia/efeitos adversos , Hiperemia/diagnóstico por imagem , Fígado/diagnóstico por imagem , Veias Hepáticas/cirurgia , Humanos , Fígado/fisiopatologia , Hepatopatias/cirurgia , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Agregado de Albumina Marcado com Tecnécio Tc 99m , Pentetato de Tecnécio Tc 99m
12.
Br J Radiol ; 91(1085): 20170632, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29470108

RESUMO

OBJECTIVE: To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. METHODS: We included 45 patients with renal dysfunction (estimated glomerular filtration rate  <45 ml per min per 1.73 m2) who underwent reduced-CM abdominal-pelvic CT (360 mgI kg-1, 80-kVp, SAFIRE) for oncological assessment. Another 45 patients without renal dysfunction (estimated glomerular filtration rate >60 ml per lmin per 1.73 m2) who underwent standard oncological abdominal-pelvic CT (600 mgI kg-1, 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. RESULTS: The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p < 0.01). CT attenuation and contrast-to-noise ratio of parenchymal organs and vessels in 80-kVp images were significantly better than those of 120-kVp images (p < 0.05). There were no significant differences in quantitative or qualitative image noise or subjective overall quality (p > 0.05). No significant kidney injury associated with CM administration was observed. CONCLUSION: 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Iodo , Rim/efeitos dos fármacos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste/efeitos adversos , Feminino , Humanos , Rim/fisiopatologia , Nefropatias/induzido quimicamente , Nefropatias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Radiografia Abdominal/métodos , Estudos Retrospectivos
13.
Neuroradiology ; 60(4): 373-379, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29476209

RESUMO

PURPOSE: The purpose of this study is to determine whether iterative model reconstruction (IMR) optimized for brain CT could improve the detection of acute stroke in the setting of thin image slices and narrow window settings. METHODS: We retrospectively reviewed 27 patients who presented acute middle cerebral artery (MCA) stroke. Images were reconstructed using filtered back projection (FBP; 1- and 5-mm slice thickness) and IMR (1 mm thickness), and contrast-to-noise ratios (CNRs) of infarcted and non-infarcted areas were compared. To analyze the performance of acute MCA stroke detection, we used receiver operating characteristic (ROC) curve techniques and compared 5-mm FBP with standard and narrow window settings, and 1-mm FBP and IMR with narrow window settings. RESULTS: The CNR in 1-mm IMR (1.1 ± 1.0) was significantly higher than in 5- (0.8 ± 0.7) and 1-mm FBP (0.4 ± 0.4) (p < 0.001). Furthermore, the average area under the ROC curve was significantly higher with 1-mm IMR with narrow window settings (0.90, 95% CI: 0.86, 0.94) than it was with 5-mm FBP (0.78, 95% CI: 0.72, 0.83). CONCLUSION: The combination of thin image slices and narrow window settings under IMR reconstruction provide better diagnostic performance for acute MCA stroke than conventional reconstruction methods.


Assuntos
Infarto da Artéria Cerebral Média/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Eur Radiol ; 28(6): 2436-2443, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29335869

RESUMO

OBJECTIVES: The current study evaluated the clinical usefulness of the gradient and spin-echo (GRASE) sequence with single breath-hold in 3.0 T magnetic resonance cholangiopancreatography (MRCP). We compared the acquisition time and image quality between GRASE and breath navigator-triggered 3D turbo spin echo (3D TSE). METHODS: We examined 54 consecutive patients who underwent MRCP with GRASE and 3D TSE. We compared the image acquisition time and contrast-to-noise ratio (CNR) between the common bile duct (CBD) and liver. Overall image quality, blurring, motion artifacts and CBD visibility were scored on a 4-point scale by two radiologists. Paired t-tests were used to compare the variables. RESULTS: The mean image acquisition time was 95 % shorter with the GRASE than with 3D TSE (GRASE: 20 s; 3D TSE: 6 min 27 s). The CNR of GRASE was significantly higher than that of 3D TSE (GRASE: 25.4 ± 13.9 vs. 3D TSE: 18.2 ± 9.6, p < 0.01). All qualitative scores for GRASE were significantly better than those for 3D TSE. CONCLUSIONS: 3.0 T MRCP with GRASE sequence with single breath-hold significantly improved the CNR of CBD with a 95 % shorter acquisition time compared with conventional 3D MRCP with 3D TSE. KEY POINTS: • MRCP acquisition time was 95% shorter with GRASE than with 3D TSE. • Overall image quality of GRASE was significantly better than 3D TSE. • Pancreaticobiliary tree visibility with GRASE was better than that with 3D TSE.


Assuntos
Artefatos , Colangiopancreatografia por Ressonância Magnética/normas , Doenças da Vesícula Biliar/diagnóstico , Imageamento Tridimensional/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
15.
J Cardiol ; 71(2): 174-180, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28865679

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is an independent risk factor for cardiovascular disorders. The aim of this study was to examine whether the quantitatively measured myocardial blood flow (MBF) or myocardial perfusion reserve (MPR), calculated by dynamic single photon emission computed tomography (SPECT) analysis using a cardiac cadmium zinc telluride (CZT) gamma camera, was related to renal dysfunction in patients with normal myocardial perfusion imaging (MPI) findings. METHODS: The study population consisted of 46 patients with CKD and 46 individuals without CKD (controls). Their MPR index was quantitatively measured using adenosine MPI with a cardiac CZT gamma camera. All assessments were with a single tissue compartment kinetic model. The K1 value was calculated on stress and at-rest images. To obtain the MPR index we divided K1 stress-by K1 at-rest values. RESULTS: The at-rest K1 value was significantly higher and the MPR index was significantly lower in patients with CKD than those without CKD [CKD vs. CONTROLS: at-rest K1 value, 0.21 (0.17-0.25) vs. 0.19 (0.16-0.22), p=0.040; MPR index, 1.86 (1.69-2.22) vs. 2.19 (1.93-2.41), p<0.001]. The stress K1 values were not significantly different. CONCLUSION: The MPR index is significantly lower in CKD patients; this is considered as being mainly due to an increase in the at-rest K1 value.


Assuntos
Coração/fisiopatologia , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Cádmio , Circulação Coronária , Feminino , Humanos , Masculino , Imagem de Perfusão do Miocárdio/métodos , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Zinco
16.
J Endocr Soc ; 1(10): 1259-1271, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29264451

RESUMO

CONTEXT: Kisspeptin receptor (KISS1R) is expressed in hypothalamic gonadotropin-releasing hormone neurons and responsible for pubertal onset and reproductive functions. KISS1R mutations remain a rare cause of congenital hypogonadotropic hypogonadism (CHH). OBJECTIVE: The aim of this study was to identify the genetic cause of CHH in a patient and to functionally characterize a KISS1R mutation. DESIGN: The patient was a 47-year-old Japanese man whose parents were first cousins. He lacked secondary sexual characteristics owing to normosmic CHH. Exon segments for the KISS1R gene in this patient were screened for mutations. Functional analyses were performed using HEK293 cells expressing KISS1R mutants. Molecular dynamics simulations were performed to compare the ligand-KISS1R mutant complex with those of wild-type KISS1R variants. RESULTS: A homozygous mutation (c.440C>T, p.P147L) in KISS1R was identified. The P147L mutation did not affect either receptor expression level or subcellular localization in the recombinant expression system. Intracellular calcium measurements and cellular dielectric spectroscopy demonstrated that the P147L mutation impaired receptor function to an extent more severe than that of a previously reported L148S mutation. A receptor-ligand binding assay showed the P147L mutation causes a substantial loss of ligand-binding affinity. Molecular dynamics simulations revealed the P147L mutation decreases the contact surface area of the ligand-receptor complex in an expanded ligand-binding pocket. CONCLUSION: We identified a loss-of-function mutation in KISS1R associated with CHH. Our results demonstrated that the P147L mutation causes a severe phenotype and functional impairment resulting from the loss of ligand-binding affinity due to an expanded ligand-binding pocket.

17.
Elife ; 62017 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-28847365

RESUMO

Peptide signaling controls many processes involving coordinated actions of multiple organs, such as hormone-mediated appetite regulation. However, the extent to which the mode of action of peptide signaling is conserved in different animals is largely unknown, because many peptides and receptors remain orphan and many undiscovered peptides still exist. Here, we identify two novel Caenorhabditis elegans neuropeptides, LURY-1-1 and LURY-1-2, as endogenous ligands for the neuropeptide receptor-22 (NPR-22). Both peptides derive from the same precursor that is orthologous to invertebrate luqin/arginine-tyrosine-NH2 (RYamide) proneuropeptides. LURY-1 peptides are secreted from two classes of pharyngeal neurons and control food-related processes: feeding, lifespan, egg-laying, and locomotory behavior. We propose that LURY-1 peptides transmit food signals to NPR-22 expressed in feeding pacemaker neurons and a serotonergic neuron. Our results identified a critical role for luqin-like RYamides in feeding-related processes and suggested that peptide-mediated negative feedback is important for satiety regulation in C. elegans.


Assuntos
Proteínas de Caenorhabditis elegans/genética , Caenorhabditis elegans/genética , Ingestão de Alimentos/fisiologia , Neuropeptídeos/genética , Receptores de Neuropeptídeo Y/genética , Resposta de Saciedade/fisiologia , Sequência de Aminoácidos , Animais , Caenorhabditis elegans/metabolismo , Proteínas de Caenorhabditis elegans/metabolismo , Regulação da Expressão Gênica , Locomoção/genética , Longevidade/genética , Neurônios/citologia , Neurônios/metabolismo , Neuropeptídeos/metabolismo , Receptores de Neuropeptídeo Y/metabolismo , Reprodução/genética , Alinhamento de Sequência , Homologia de Sequência de Aminoácidos , Transdução de Sinais
18.
Medicine (Baltimore) ; 96(23): e6973, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28591031

RESUMO

We evaluated whether donor computed tomography (CT) with a combined technique of lower tube voltage and iterative reconstruction (IR) can provide sufficient preoperative information for liver transplantation.We retrospectively reviewed CT of 113 liver donor candidates. Dynamic contrast-enhanced CT of the liver was performed on the following protocol: protocol A (n = 70), 120-kVp with filtered back projection (FBP); protocol B (n = 43), 100-kVp with IR. To equalize the background covariates, one-to-one propensity-matched analysis was used. We visually compared the score of the hepatic artery (A-score), portal vein (P-score), and hepatic vein (V-score) of the 2 protocols and quantitatively correlated the graft volume obtained by CT volumetry (graft-CTv) under the 2 protocols with the actual graft weight.In total, 39 protocol-A and protocol-B candidates showed comparable preoperative clinical characteristics with propensity matching. For protocols A and B, the A-score was 3.87 ±â€Š0.73 and 4.51 ±â€Š0.56 (P < .01), the P-score was 4.92 ±â€Š0.27 and 5.0 ±â€Š0.0 (P = .07), and the V-score was 4.23 ±â€Š0.78 and 4.82 ±â€Š0.39 (P < .01), respectively. Correlations between the actual graft weight and graft-CTv of protocols A and B were 0.97 and 0.96, respectively.Liver-donor CT imaging under 100-kVp plus IR protocol provides better visualization for vascular structures than that under 120-kVp plus FBP protocol with comparable accuracy for graft-CTv, while lowering radiation exposure by more than 40% and reducing contrast-medium dose by 20%.


Assuntos
Hepatectomia , Transplante de Fígado , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Doadores Vivos , Tomografia Computadorizada por Raios X , Adulto , Meios de Contraste , Feminino , Artéria Hepática/diagnóstico por imagem , Veias Hepáticas/diagnóstico por imagem , Humanos , Fígado/cirurgia , Masculino , Tamanho do Órgão , Melhoria de Qualidade , Doses de Radiação , Estudos Retrospectivos
19.
Biomed Res ; 38(3): 215-219, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28637957

RESUMO

The Gm7325 gene, bioinformatically identified in the mouse genome, encodes a small protein but has not been characterized until recently. Our gene expression analysis revealed that Gm7325 transcription is remarkably upregulated in injured skeletal muscle tissues. Activated satellite cells and immature myotubes were densely decorated with positive signals for Gm7325 mRNA in in situ hybridization analysis, while no obvious signals were observed in quiescent satellite cells and mature myofibers. In the 5'-flanking regions of mouse Gm7325 and its human homologue, conserved E-box motifs for helix-loop-helix transcription factors are repeatedly arranged around the putative promoter regions. Reporter gene assays suggested that MyoD, a master transcription factor for myogenesis, binds to the conserved E-box motifs to activate Gm7325 expression. Therefore, Gm7325, as a novel MyoD-target gene, is specifically induced in activated satellite cells, and may have an important role in skeletal myogenesis.


Assuntos
Proteínas de Membrana/fisiologia , Proteína MyoD/fisiologia , Células Satélites de Músculo Esquelético/fisiologia , Animais , Sequência de Bases , Linhagem Celular , Sequência Consenso , Expressão Gênica , Células HeLa , Humanos , Camundongos , Desenvolvimento Muscular , Ativação Transcricional
20.
J Comput Assist Tomogr ; 41(6): 884-890, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448422

RESUMO

OBJECTIVES: The objective of this study is to evaluate the usefulness of iterative model reconstruction designed for brain computed tomography (CT) (IMR-Neuro) for the diagnosis of acute ischemic stroke. METHODS: This retrospective study included 20 patients with acute middle cerebral artery infarction who have undergone brain CT and 20 nonstroke patients (control). We reconstructed axial images with filtered back projection (FBP) and IMR-Neuro (slice thickness, 1 and 5 mm). We compared the CT number of the infarcted area, the image noise, contrast, and the contrast to noise ratio of the infarcted and the noninfarcted areas between the different reconstruction methods. We compared the performance of 10 radiologists in the detection of parenchymal hypoattenuation between 2 techniques using the receiver operating characteristic (ROC) techniques with the jackknife method. RESULTS: The image noise was significantly lower with IMR-Neuro [5 mm: 2.5 Hounsfield units (HU) ± 0.5, 1 mm: 3.9 HU ± 0.5] than with FBP (5 mm: 4.9 HU ± 0.5, 1 mm: 10.1 HU ± 1.4) (P < 0.01). The contrast to noise ratio was significantly greater with IMR-Neuro (5 mm: 2.6 ± 2.1, 1 mm: 1.6 ± 1.3) than with FBP (5 mm: 1.2 ± 1.0; 1 mm: 0.6 ± 0.5) (P < 0.01). The value of the average area under the receiver operating curve was significantly higher with IMR-Neuro than FBP (5 mm: 0.79 vs 0.74, P = 0.04; 1 mm: 0.76 vs 0.69, P = 0.04). CONCLUSIONS: Compared with FBP, IMR-Neuro improves the image quality and the performance for the detection of parenchymal hypoattenuation with acute ischemic stroke.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estatística como Assunto , Acidente Vascular Cerebral/etiologia , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA