Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rinsho Byori ; 49(11): 1096-101, 2001 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-11769554

RESUMO

The apparatus for the respiratory function test have recently made a great progress and become very easy to handle owing to the development of computer technology and medical ordering system. However, the respiratory function tests depend its result on the cooperation of patients. Thus, it is important for the medical technician to obtain the maximum efforts and cooperation of the patients in the testing. In the sense, the standardization of the testing should be done urgently regarding procedures, softwares, hardwares and maintenance of apparatus. In the future perspectives, we would like to emphasize following 3 points. First, more noninvasive and sophisticated testing methods and instruments should be developed, since the patients' age will become more and more old and vigorous active cooperation may not be possible for the assessment of respiratory function. The testing for the transplantation of lung should also be developed. Second, the development of screening test and its performance for the routine medical check for the local inhabitants have been important for the early detection, treatment, and follow up of respiratory diseases. Finally, the medical technician should be prepared so that the testing is available when it is needed.


Assuntos
Testes de Função Respiratória/normas , Testes de Função Respiratória/tendências , Fluxo Expiratório Forçado , Humanos , Padrões de Referência , Testes de Função Respiratória/instrumentação , Software
2.
Nippon Ganka Gakkai Zasshi ; 99(7): 849-54, 1995 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-7661050

RESUMO

Non-invasive measurements of blood velocities of the ophthalmic artery (BVA) in color Doppler imaging (CDI) are increasingly used to assess the influence of disease on the hemodynamics of the eye. Such measurements are only valid when compared to spontaneous variability. Therefore, the aim of this study was to examine the variability of BVA in healthy subjects. Within-a-day short-term variability was assessed from measurements obtained during one day from 5 healthy young male subjects as the coefficient of variation (CV) of 10 consecutive measurements. Between-days variability was assessed by comparing measurements made on three different days at one month intervals. The left and right BVA were measured five consecutive times to evaluate the difference in BVA between left and right eyes in 5 healthy young male subjects. In the within-a-day variability, mean CV in maximum systolic BVA (V max), minimum end diastolic BVA (V min), time-averaged BVA (V mean), resistive index (RI), and pulsatility index (PI) were found to be 6.6%, 14.0%, 14.9%, 3.2%, and 17.4%, respectively. The between-days variability was just as high as the within-a-day variability. There was significant difference in BVA between left and right eyes in two of the five subjects. We concluded that the within-a-day variability and the between-days variability of BVA measured using CDI are reproducible. The CDI can be used to assess the influence of disease and drugs on the hemodynamics of the eye.


Assuntos
Artéria Oftálmica/fisiologia , Ultrassonografia Doppler em Cores , Adulto , Velocidade do Fluxo Sanguíneo , Humanos , Masculino , Artéria Oftálmica/diagnóstico por imagem , Reprodutibilidade dos Testes