Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Otol Neurotol ; 44(5): e268-e272, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37167443

RESUMO

INTRODUCTION: Very few studies have compared the magnitude of the changes in the hearing thresholds at 1 and 4 kHz according to the systolic blood pressure (SBP). We investigated the effects of SBP on repeated measures of hearing threshold using pure-tone audiometry. METHODS: This retrospective cohort study included 5,479 (for the analysis at 1 kHz) and 2,045 (for 4 kHz) individuals aged 50 to 59 years who underwent facility-based health checkups. A multivariable generalized linear mixed model was constructed for the analysis at 1 and 4 kHz. RESULTS: The mean follow-up durations were 30,262 and 7,454 person-years, respectively. The interaction of SBP and year was significantly associated with the change in hearing threshold in both analyses at 1 kHz (with estimated slope, 0.00080; 95% confidence interval, 0.00049-0.00110) and 4 kHz (with estimated slope, 0.0042; 95% confidence interval, 0.0028-0.0057). The 10-year changes in hearing threshold with baseline SBP of 110 and 140 mm Hg were 0.4 and 0.6 dB at 1 kHz and 1.0 and 2.3 dB at 4 kHz, respectively. CONCLUSIONS: Higher SBP was associated with an increased hearing threshold at both 1 and 4 kHz among middle-aged individuals.


Assuntos
População do Leste Asiático , Audição , Humanos , Pessoa de Meia-Idade , Audiometria de Tons Puros , Limiar Auditivo/fisiologia , Pressão Sanguínea , Estudos Retrospectivos
2.
SAGE Open Med Case Rep ; 10: 2050313X221100874, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35619750

RESUMO

Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomography, showing soft tissue opacity between the tip of the tracheostomy tube and the bronchi. A movable mass in the trachea, identified as mucus by pathological examination, was removed using bronchoscopy. Acute airway obstruction by a mucus plug potentially occurred with a long history of insertion of a tracheostomy tube. Emergency imaging studies and bronchoscopy were useful for management.

3.
Clin Anat ; 35(7): 891-898, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35417615

RESUMO

Superior mesenteric artery (SMA) syndrome is related to the reduction of the aortomesenteric angle on detailed imaging studies; i.e., an expert's ultrasonography or angiography. We aimed to test a simpler imaging finding of SMA syndrome. This cross-sectional case-reference study examined whether right movement of the SMA on unenhanced computed tomography (CT) is useful for the diagnosis of SMA syndrome. We reviewed hospital records of patients admitted in 2008-2018. Each case was matched to one non-case patient of the same age and sex. On unenhanced CT scans, we identified the shortest distance between the parallel line that passes through the center of the aorta to the line that bisects the spine and SMA. A negative number of the distance means that the SMA is on the left side of the above-described parallel line. There was a total of 14 cases and 14 non-cases (men, 57.1%) with mean age 78.7 years. Mean body mass index of cases and non-cases were 19.2 and 22.2 kg/m2 , respectively. The more prevalent side of the SMA was the right side. The mean shortest distance was 10.5 mm in cases and 0.7 mm in non-cases (p for independent t test = 0.043). For comparing the observations in SMA cases at several time points, the mean shortest distance at pre-onset was -2.7 mm, with a significant difference from that at onset (p for paired t test = 0.030). In conclusion, right movement of the SMA diagnosed by unenhanced CT is associated with SMA syndrome.


Assuntos
Síndrome da Artéria Mesentérica Superior , Idoso , Angiografia , Estudos Transversais , Humanos , Masculino , Artéria Mesentérica Superior/diagnóstico por imagem , Síndrome da Artéria Mesentérica Superior/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Hypertens Res ; 45(1): 155-161, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34690351

RESUMO

This retrospective longitudinal study examined the association between systolic blood pressure and hearing impairment among 13,187 Japanese individuals (men, 46.5%) aged 20-59 years. The systolic blood pressure of participants was categorized as <120, 120-129, 130-139, 140-149, 150-159, and ≥160 mmHg. Using pure-tone audiometry, hearing impairment at 1 and 4 kHz was defined as hearing thresholds in either ear >30 and >40 dB, respectively. We performed multivariable Cox proportional-hazards regression analysis to examine the association using two multiple-imputation methods (fully conditional specification and Markov chain Monte Carlo). There were 695 and 774 hearing-impairment cases at 1 and 4 kHz, respectively, during ~77,000 person-years of follow-up. Compared with the <120 mmHg group, the hazard ratios (95% confidence intervals) of hearing impairment for the 120-129, 130-139, 140-149, 150-159, and ≥160 mmHg groups after adjustment for age, sex, body mass index, high serum glucose, current smoking, and other potential confounders were 1.35 (1.12-1.63), 1.45 (1.13-1.86), 1.07 (0.73-1.58), 1.91 (1.18-3.07), and 1.81 (1.01-3.25), respectively, at 1 kHz using the first imputation method; 1.36 (1.13-1.63), 1.48 (1.17-1.86), 1.09 (0.76-1.58), 1.99 (1.29-3.06), and 1.92 (1.08-3.41), respectively, at 1 kHz using the second imputation method; 1.04 (0.86-1.24), 1.14 (0.91-1.43), 1.13 (0.83-1.54), 1.45 (0.96-2.19), and 1.35 (0.82-2.23), respectively, at 4 kHz using the first imputation method; and 1.03 (0.86-1.24), 1.17 (0.95-1.44), 1.15 (0.87-1.53), 1.54 (1.06-2.24), and 1.44 (0.88-2.35), respectively, at 4 kHz using the second imputation method. In conclusion, higher systolic blood pressure was associated with hearing impairment at 1 kHz. No clear association was observed at 4 kHz.


Assuntos
Perda Auditiva , Adulto , Pressão Sanguínea , Perda Auditiva/epidemiologia , Humanos , Japão/epidemiologia , Estudos Longitudinais , Masculino , Estudos Retrospectivos
5.
Am J Clin Oncol ; 43(11): 784-787, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32826390

RESUMO

OBJECTIVES: The objective of this study was to compare the clinical effectiveness of uncovered stent and covered stent as percutaneous endoprosthesis for malignant biliary obstruction of the extrahepatic bile duct. MATERIALS AND METHODS: After completion of percutaneous internal and external tube placement for unresectable malignant biliary obstruction, 60 patients were registered and randomly assigned in a 1:1 ratio to an uncovered or covered stent group. Metallic stent placement was performed within 1 week after registration, and an external biliary drainage tube was removed >3 days after stent placement. The primary endpoint was the obstructive jaundice-free survival rate at 24 weeks after registration, and the secondary endpoints were the success rate of percutaneous tube removal and adverse events. RESULTS: The obstructive jaundice-free survival rate at 24 weeks after registration was 13/29 (44.8%, 95% confidence interval [CI]: 28.4%-62.5%) and 15/30 (50.0%, 95% CI: 33.2%-66.8%) in the uncovered and covered stent groups, respectively. The success rate of percutaneous tube removal was 28/29 (96.6%, 95% CI: 82.8%-99.4%) and 30/30 (100%, 95% CI: 90.5%-100%) in the uncovered and covered stent groups, respectively. There were no procedure-related deaths. Twenty-eight adverse events were observed in 21 patients (7 in the uncovered stent group and 14 in the covered stent group). CONCLUSIONS: There was no significant difference in the obstructive jaundice-free survival rate at 24 weeks between the 2 groups. Considering the technical difficulty and invasiveness of covered stent placement, the placement of covered stents may not be needed in patients with a short prognosis of <24 weeks.


Assuntos
Neoplasias dos Ductos Biliares/complicações , Ductos Biliares Extra-Hepáticos/patologia , Ductos Biliares Extra-Hepáticos/cirurgia , Colestase/cirurgia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/patologia , Colestase/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Resultado do Tratamento
6.
Phys Chem Chem Phys ; 18(40): 27837-27847, 2016 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-27711694

RESUMO

Hydroxyapatites are increasingly used as heterogeneous catalysts since they present atypical behaviours for many acid base reactions. The aim of this study was to discuss the possible involvement of Ca2+ Lewis and/or PO-H Brønsted acid sites belonging to the hydroxyapatite system in the conversion of 2-methylbut-3-yn-1-ol, a model molecule that is known to account for the acid base properties, and of ethanol into n-butanol. A series of hydroxyapatite samples with similar bulk properties was prepared from a lone precipitation batch, but by varying the conditions of the washing and drying steps. Although the surface depth probed by XPS exhibited similar average composition, ISS analysis revealed a gradient of calcium concentration in the first surface layers. In fact, the different conditions of drying and washing resulted in a modulation of the relative amount of Ca2+ and PO-H accessible on the top surface, as revealed by the adsorption of the CO molecule monitored by FTIR. The conversion in the two alcohol molecules is linearly dependent on the nature of the acid base pairs involved: when accessible on the top surfaces, due to their stronger acidity, the Ca2+ Lewis acid sites are preferentially involved, but they are less efficient than PO-H, as illustrated by the linear decrease of the conversion levels with the increasing relative amount of accessible Ca2+ cations. It is thus concluded that PO-H sites enhance the performances of the catalysts for the two reactions, and that washing and drying conditions allowing us to decrease the calcium accessibility at the benefit of PO-H should be favoured.

7.
Case Rep Radiol ; 2013: 160653, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23607030

RESUMO

Purpose. Interventional treatment strategies for patients with encephalopathy due to splenorenal shunt remain controversial. Portosplenic blood flow separation by occluding the splenic vein could avoid the complication of severe portal hypertension, but it would require repeated reintervention due to recurrence of symptoms. This paper describes occlusion of the splenic vein using coil anchors and prophylactic embolization of a collateral hepatofugal vessel with no recurrence of hyperammonemia. Materials and Methods. A 51-year-old woman with severe cirrhosis had hepatic encephalopathy due to a large splenorenal shunt. The serum ammonia level was 132 µ g/dL. Via a transileocolic approach, the splenic vein was completely embolized with 0.035-inch metallic coils using coil anchors while preserving the splenorenal shunt. In addition, one of the collateral vessels of the portal vein, the retrogastric vein, was also embolized prophylactically. Results. After this procedure, the serum ammonia level decreased immediately to 24 µ g/dL. The portal venous pressure increased by only 1.5 mmHg. Hepatic encephalopathy had not been observed for 25 months after the procedure, and neither retention of ascites nor worsening of esophageal varices and liver function was observed. Conclusion. This procedure appears to be safe and effective for hepatic encephalopathy caused by a splenorenal shunt.

8.
Gan To Kagaku Ryoho ; 39(4): 619-23, 2012 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-22504688

RESUMO

A patient registration system is mandatory for establishing the scientific credibility of the multi-center clinical trials. The Japan Interventional Radiology in Oncology Study Group (JIVROSG) was organized in 2002 to establish evidence supporting the procedures used in interventional radiology. The Internet Data and Information Center for Medical Research (INDICE), provided by the University Hospital Medical Information Network(UMIN), has been utilized for patient registration in the clinical trials of JIVROSG. In this study, the safety and efficacy of UMIN-INDICE were evaluated. From 2002 to 2010, 18 clinical trials, including one international trial, were conducted. A total of 736 patients were enrolled from 51 institutions. No significant trouble was encountered during this period. A questionnaire survey demonstrated that 90% of participating researchers could use this system without difficulties. UMIN-INDICE may contribute to promoting clinical trials as an infrastructure of multicenter studies.


Assuntos
Ensaios Clínicos como Assunto , Internet , Humanos , Inquéritos e Questionários
9.
J Anesth ; 26(3): 326-33, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22327144

RESUMO

PURPOSE: Cultural views are purported to be critical barriers to the use of epidural anesthesia during childbirth in Japan, even though it is not routinely available. We sought to understand the importance of the asserted cultural barriers for Japanese women living in Michigan in the United States where access to epidural anesthesia is routine. METHODS: We used a mixed-methods approach including self-administered, cross-sectional mail surveys and semi-structured qualitative interviews. Participants were Japanese women who received prenatal care at the University of Michigan Japanese Family Health Program. RESULTS: Of 78 participants in the mail survey, 63% used epidural anesthesia. Positive influences to have epidural anesthesia came from friends (58%), husbands (42%), and knowledge of the epidural anesthesia experiences of others (50%). Seventeen respondents participated in qualitative interviews. Most had learned little about epidural anesthesia while living in Japan, and some respondents had heard unsettling rumors. Many mentioned obtaining their first detailed knowledge about epidural anesthesia from friends in the United States, and expressed fear or concerns about the side effects of anesthesia. Thirteen out of fourteen interviewed participants who used or wanted epidural anesthesia expressed a desire to use it for the next childbirth. CONCLUSIONS: While Japanese women in this United States setting considered previously reported cultural barriers to epidural anesthesia for birth pain, many chose to have it during their labor. This finding implicates limited access as a barrier at least as important as cultural barriers to epidural anesthesia use in Japan.


Assuntos
Anestesia Epidural , Anestesia Obstétrica , Adulto , Povo Asiático , Estudos Transversais , Feminino , Humanos , Parto , Gravidez , Estados Unidos
10.
Radiol Res Pract ; 2011: 830961, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22191031

RESUMO

Purpose. To evaluate the educational effect of the Japanese Society of Interventional Radiology 7th Academic Summer Seminar from a technical perspective. Materials and Methods. Nineteen trainees participated in the seminar. The seminar consisted of vertebroplasty trainings using swine with the single-plane landmark method and with the ISOcenter Puncture (ISOP) method. All trainees were advised by an instructor as they operated the instruments and punctured the vertebra. For each trainee, the accuracy in the final position of the needle tip of the initial puncture in each swine training was evaluated. Results. Error in the final position of the needle tip of ≥5 mm from the target puncture site occurred in the lateral direction in 42% (8/19) of trainees with the landmark method and 5% (1/19) with the ISOP method. No error ≥5 mm occurred in the vertical or anteroposterior directions. In terms of puncture accuracy, error in the lateral direction was significantly lower with the ISOP method than with the landmark method (2.2 ± 1.5 mm versus 5.6 ± 3.2 mm). Conclusion. This seminar was effective training for trocar placement for beginners. The puncture was more accurate with the ISOP method than with the landmark method.

11.
Am J Clin Oncol ; 34(1): 58-62, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20177362

RESUMO

OBJECTIVES: No established therapy exists for unresectable intrahepatic cholangiocarcinoma (ICC). We conducted a phase I/II study to ascertain the recommended dose (RD) of hepatic arterial infusion using gemcitabine (GEM) for ICC and to assess the efficacy and safety. METHODS: For patients with unresectable ICC, GEM was administered through the hepatic artery via the port system as a 30-minute infusion on days 1, 8, and 15 every 4 weeks for 5 cycles. In phase I, dosage for levels 1, 2, and 3 was set at 600, 800, and 1000 mg/m, respectively, and was increased in 3 to 6 patients at a time. Maximum tolerated dose was defined as a dosage resulting in dose-limiting toxicity in 2 of 3 patients or 3 of 6 patients, and RD was estimated during the first cycle. In the phase II, more RD patients were added to assess tumor response and toxicity. RESULTS: During the phase I, 16 patients were enrolled. Maximum tolerated dose was not reached. Assuming RD at 1000 mg/m, the phase II enrolled a total of 13 patients. The following Grade 3 toxicities were observed: neutropenia 20%, increased gamma-glutamyl transpeptidase 8%, increased aspartate aminotransferase 4%, increased alanine aminotransferase 4%, increased bilirubin 4%, nausea 4%, and fatigue 4%. The tumor response rate was 7.7% (complete response 0, partial response 1, stable disease 8, and progressive disease 4). CONCLUSION: Whereas the toxicity of hepatic arterial infusion with 1000 mg/m GEM for ICC was tolerable, expected efficacy could not be obtained, thus suggesting only minimal activity.


Assuntos
Antimetabólitos Antineoplásicos/uso terapêutico , Ductos Biliares Intra-Hepáticos/efeitos dos fármacos , Desoxicitidina/análogos & derivados , Adulto , Idoso , Neoplasias dos Ductos Biliares/tratamento farmacológico , Neoplasias dos Ductos Biliares/patologia , Neoplasias dos Ductos Biliares/cirurgia , Ductos Biliares Intra-Hepáticos/patologia , Ductos Biliares Intra-Hepáticos/cirurgia , Colangiocarcinoma/tratamento farmacológico , Colangiocarcinoma/patologia , Colangiocarcinoma/cirurgia , Desoxicitidina/uso terapêutico , Feminino , Artéria Hepática , Humanos , Infusões Intra-Arteriais , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Taxa de Sobrevida , Resultado do Tratamento , Gencitabina
12.
Cardiovasc Intervent Radiol ; 34(3): 601-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21153415

RESUMO

PURPOSE: This study was designed to clarify the advantages of biodegradable stents in terms of mucosal reaction and biodegradation after placement. We designed a biodegradable stent and assessed stent degradation and changes in the normal bile ducts of dogs. METHODS: The biodegradable stent is a balloon-expandable Z stent consisting of poly-L-lactic acid (PLLA) with a diameter of 6 mm and a length of 15 mm. We assessed four groups of three beagle dogs each at 1, 3, 6, and 9 months of follow-up. After evaluating stent migration by radiography and stent and bile duct patency by cholangiography, the dogs were sacrificed to remove the bile duct together with the stent. The bile duct lumen was examined macroscopically and histologically, and the stent degradation was examined macroscopically and by scanning electron microscopy (SEM). RESULTS: Bile duct obstruction was absent and none of the stents migrated. Macroscopic evaluation showed moderate endothelial proliferation in the bile ducts at the implant sites at 3 and 6 months and a slight change at 9 months. Slight mononuclear cell infiltration was histologically identified at all time points and epithelial hyperplasia that was moderate at 3 months was reduced to slight at 6 and 9 months. Stent degradation was macroscopically evident in all animals at 9 months and was proven by SEM in two dogs at 6 months and in all of them at 9 months. CONCLUSIONS: Our results suggest that PLLA bioabsorbable stents seems to be useful for implantation in the biliary system with further investigation.


Assuntos
Ductos Biliares , Stents , Implantes Absorvíveis , Animais , Materiais Biocompatíveis , Colangiografia , Meios de Contraste/administração & dosagem , Diatrizoato de Meglumina/administração & dosagem , Cães , Ácido Láctico , Masculino , Modelos Animais , Poliésteres , Polímeros , Desenho de Prótese
13.
World J Surg ; 33(11): 2396-402, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19655195

RESUMO

BACKGROUND: The clinical outcome of malignant biliary obstruction caused by metastatic gastric cancer remains unclear. This study was designed to evaluate the clinical outcome and predictive factors of survival in patients who underwent percutaneous transhepatic biliary drainage (PTBD) for malignant biliary obstruction caused by metastatic gastric cancer. METHODS: Between April 1997 and March 2006, 38 consecutive patients with malignant biliary obstruction caused by metastatic gastric cancer were retrospectively analyzed. All patients underwent PTBD. RESULTS: After PTBD, serum bilirubin levels significantly decreased in 29 (76%) of 38 patients. Pruritus, fever, jaundice, anorexia, abdominal pain, and general fatigue improved significantly in 100%, 100%, 78%, 64%, 53%, and 48% of patients, respectively. Early complications related to the intervention occurred in ten patients. Seven patients developed symptoms of recurrent jaundice or cholangitis. Overall median survival was 79 days, and 6-month and 1-year survival rates after PTBD were 39.5% and 13.2%, respectively. Serum bilirubin level after PTBD (P < 0.0001), chemotherapy after PTBD (P < 0.0001), and performance status at presentation (P = 0.0363) were found to be independent predictors of survival. CONCLUSION: PTBD with metallic stent placement is a safe and effective palliation for patients with malignant biliary obstruction caused by metastatic gastric cancer. Our results suggest that patients in good clinical condition are candidates for aggressive treatment with a combination of PTBD with metallic stent placement and chemotherapy.


Assuntos
Neoplasias do Sistema Biliar/secundário , Colestase/terapia , Neoplasias Gástricas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Sistema Biliar/complicações , Colangiografia , Colestase/etiologia , Colestase/patologia , Drenagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Stents , Análise de Sobrevida , Resultado do Tratamento
14.
Cardiovasc Intervent Radiol ; 30(5): 959-67, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17546400

RESUMO

PURPOSE: To retrospectively clarify the utility of metallic stent placement for the treatment of the malignant obstruction of the superior vena cava (SVC) in 71 patients with VC syndrome (SVCS) on the basis of long-term follow-up data. MATERIALS AND METHODS: Seventy-one patients underwent stent placement and were followed until death. The applicability of the spiral Z-stent (S-Z-stent) mainly used the initial and follow-up results, stent placement for bilateral BCV obstruction and the value of concurrent anticancer therapy were studied. RESULTS: The technical success rate was 100%, the initial clinical success rate was 87% (62/71), the primary clinical patency rate was 88% (57/65), and the secondary clinical patency rate was 95% (62/65). The obstruction rate of the stent was 12% (8/65), and an additional stent was useful for relief of recurrent SVCS. Survival of 57 patients in whom there was no recurrence of SVCS until death ranged from 1 week to 29 months (mean, 5.4 months and the S-Z-stent appeared to be suitable for the treatment of the malignant obstruction of SVC. Unilateral stent placement was effective for relief of SVCS with bilateral BCV obstruction. Patients who received concurrent anticancer therapy survived 2 months longer than those who did not. CONCLUSION: Stent placement is an effective treatment for SVCS. Further, the utility of S-Z-stent for SVCS, an additional stent for recurrence, unilateral stent for patients with bilateral BCV obstruction, and anticancer therapy after stent placement were verified.


Assuntos
Implante de Prótese Vascular/instrumentação , Metais , Neoplasias/complicações , Stents , Síndrome da Veia Cava Superior/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/uso terapêutico , Implante de Prótese Vascular/efeitos adversos , Veias Braquiocefálicas/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/tratamento farmacológico , Neoplasias/mortalidade , Neoplasias/radioterapia , Neoplasias/cirurgia , Flebografia , Desenho de Prótese , Recidiva , Estudos Retrospectivos , Síndrome da Veia Cava Superior/diagnóstico por imagem , Síndrome da Veia Cava Superior/etiologia , Síndrome da Veia Cava Superior/mortalidade , Síndrome da Veia Cava Superior/fisiopatologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
15.
Nihon Igaku Hoshasen Gakkai Zasshi ; 63(5): 201-9, 2003 May.
Artigo em Japonês | MEDLINE | ID: mdl-12822444

RESUMO

PURPOSE: To assess the physical properties of biliary self-expandable metallic stents. MATERIALS AND METHODS: Six different types of biliary self-expandable metallic stents (Wallstent, ZA stent, Accuflex, S.M.A.R.T. stent, Spiral Z stent, and NT stent) were evaluated for the flexibility, trackability, and resistance of stent release for the introducer, and for repulsion force, flexibility, radial force, radio-opacity, and kink resistance for the stent. RESULTS: The Wallstent showed the best repulsion force, radio-opacity, and kink- resistance, while the ZA stent showed the best flexibility and trackability of the introducer and better radial force and radio-opacity. Accuflex showed the least resistance during stent release and better flexibility and radial force. The S.M.A.R.T. stent showed the largest radial force, and the Spiral Z stent showed better trackability of the introducer and better radio-opacity. The NT stent seemed to require overall improvement. CONCLUSION: The Wallstent appears preferable for placement in the extrahepatic bile ducts. The ZA stent can be applied for various approaches, but placement in comparatively straight bile ducts is preferable. With the Accuflex, insertion through routes where an acute angle exists should be avoided. In addition, balloon expansion before or after stent placement is preferable. The S.M.A.R.T. stent is placed in straighter intrahepatic bile ducts, while the Spiral Z stent should be placed through a straight approach. Balloon expansion before or after stent placement is preferable for the NT stent. No stent exhibited all of the ideal properties required. These results may contribute to the selection of biliary metallic stents.


Assuntos
Ductos Biliares , Metais , Stents , Mecânica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA