Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
RSC Adv ; 14(23): 16318-16326, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38774613

RESUMO

Sustainable analytical chemistry is gaining great interest in global environmental pollution control. In addition, valsartan (VAS) and sacubitril (SAB) have been recently approved by the FDA as a fixed-dose combination "LCZ696". It showed efficacy and safety enough to extend its application from heart failure to hypertension control. VAS/SAB dual therapy is considered expensive; however, its prescription has increased significantly worldwide. This prescription increased the demand for developing sustainable analytical methods that simultaneously analyze VAS and SAB. Highly sensitive and selective spectrofluorimetric methods have been developed for this purpose. A synchronous spectrofluorimetric technique was applied. In one method, it was followed by spectral derivatization at the first-order level. The signals were recorded at 230 and 211 nm for VAS and SAB, respectively. Synchronous spectrofluorimetry was coupled to a dual-wavelength mathematical approach in the second method. Signals were derived by subtracting synchronous responses at 241 nm, 226 nm, and 239 nm from the response at 208 nm for VAS and SAB, respectively. Method validation was carried out following ICH guidelines. VAS showed linear calibration curves spanning the range of 60-200 and 80-600 ng mL-1 for the derivative and dual wavelength-assisted approaches, respectively. SAB achieved linear responses in the range of 17-190 and 30-350 ng mL-1 for the first and second methods, respectively. The green profile of the proposed methods was confirmed using the analytical eco-scale (AES), green analytical procedure index (GAPI), and analytical greenness metric (AGREE) tools. The proposed hybrid methods proved highly sustainable through the whiteness RGB 12 algorithm evaluation approach. Whiteness was comparatively assessed for the proposed and reported methods based on relative scoring depending on the parameters of each method. Despite this scoring approach being accurate as a relative score for comparative purposes, it gave rise to underestimated absolute scores. Therefore, to obtain a proper conclusion from the comparative whiteness study, all the methods were ranked according to their whiteness score, illustrating the excellent whiteness ranks of the proposed methods. Upon complete comparison with the reported methods, the suggested ones showed several advantages concerning analytical performance and the greenness level. The proven affordability and simplicity encourage their wide industrial application in developing countries.

2.
Int J Pharm ; 650: 123730, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38142014

RESUMO

Skin cancer is considered the fifth most commonly occurring cancer worldwide hampering both health and economy. Piperine had proven efficacy in fighting skin cancer cells. Unfortunately, this natural agent had limited ability to penetrate the skin. The aim of the current study was to formulate piperine-loaded limosomes and hyalurolimosomes incorporating limonene as an edge activator and hyaluronic acid as bioactive gelling agent for managing skin cancer. Titration method followed by homogenization was adopted to prepare the nanoliposomal formulations. Characterization involved size, & zeta potential measurements, examination using transmission electron microscope (TEM) and stability study. Biological evaluation of the antitumor activity of piperine nanoliposomal formulations against Ehrlich's (EAC) solid tumor was also performed. Drug loaded limosomes and hyalurolimosomes had particle size; 346.55 ± 8.55 & 372.70 ± 10.83 nm, respectively. Zeta potential was high enough to ensure their stability. TEM micrographs detected the surrounding layer of Hyaluronic acid formed around the spherical limosomal nano-carrier ensuring the formation of Hyalurolimosomes. All stored formulations showed non-significant differences compared with freshly prepared ones at p < 0.05. In addition, A DAD-HPLC method was developed and validated for Piperine analysis in the skin. Upon application of this method, it was found that hyalurolimosomes deliver double the concentration delivered by limosomes. The piperine hyalurolimosome group showed a significant reduction in tumor size with a smaller AUC compared to piperine gel, which was confirmed by in vivo studies. Consequently, hyalurolimosomes loaded with piperine is considered a promising nanocarrier system and a step forward better management of skin cancer introducing new hope in beating this deadly disease.


Assuntos
Alcaloides , Neoplasias Cutâneas , Humanos , Ácido Hialurônico , Benzodioxóis , Pele , Tamanho da Partícula , Neoplasias Cutâneas/tratamento farmacológico , Lipossomos
3.
BMC Chem ; 17(1): 179, 2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38072975

RESUMO

As a GABA-ß receptor agonist, the central muscle relaxant Baclofen (BAC) has a potential of abuse. Unfortunately, the sense of wellbeing and pleasure is obtained at very high BAC doses. This is associated with many life-threating or even fatal cases due to neurological and respiratory failures. Moreover, having narrow therapeutic index makes BAC a high-risk drug. This is potentiated in case of long-treatment regimen or off-label use in smoking and alcohol cessation protocols. Until now, there is no rapid diagnostic test available for BAC screening. Therefore; It is quite difficult to routinely monitor cases on BAC regimen. On the other hand, smartphone-based colorimetric point of care testing (POCT) is displacing conventional analytical approaches in the detection and assay of abused drugs as well as therapeutic drug monitoring. It offers on-site, rapid, easy, affordable and interpretable analysis. Incorporating smartphone as a portable device facilitates its application, especially in remote areas and low-income countries. For the first time, the current work presents a smartphone-based colorimetric POCT for BAC analysis in urine without interference from urine matrix. It depends on BAC reaction with naphthoquinone sulfonate (NQS) in highly alkaline aqueous medium. The developed color was captured in a customized photo box using smartphone camera. Then, intensity of the blue channel was measured by a software application "Color Analyzer". All parameters were optimized with respect to the colorimetric reaction, photographing and smartphone-based analysis. All parameters were successfully investigated according to FDA guidelines for bioanalytical method validation. Also, all POCT criteria were considered as per WHO requirements. This method could determine BAC, linearly, from 0.02 to 0.21 mmol L-1 in urine. Moreover, LLOQ was lower than the expected BAC therapeutic concentrations in urine. The proposed method proved high reliability and suitability to analyze BAC in urine. This strongly recommends its routine application in screening BAC abusers and BAC therapeutic monitoring.

4.
Int J Pharm ; 625: 122129, 2022 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-36007851

RESUMO

Burn wounds are one of the most severe complex forms of trauma. Hence, new treatment strategies that facilitate the healing process; reduce the severity and the healing time is the main concern of the health care systems. In this work, pentoxifylline-valsartan, (PTX- VAL), loaded liposomes integrated into gel were designed for the first time as a novel co-delivery carrier for the treatment of burn wounds. The objective of this work was to investigate the ability of the nano-based liposomal system to co-entrap two repurposed drugs; hydrophilic pentoxifylline and lipophilic valsartan for topical treatment of burn wounds. The impact of increasing the phospholipid amount to enhance the co-entrapment of PTX and VAL was investigated and in-vitro evaluation of the prepared formulations was conducted to choose the optimum composition with the highest entrapment of both drugs adopting a simple, reliable derivative spectrophotometric method. Structure elucidation was also performed using a transmission electron microscope. In addition, A simple selected derivative spectrophotometric method was developed for the assay of PTX-VAL novel combination. The proven selectivity, precision and accuracy assured the reliability of this analytical method. Being economic and fast makes routine application of the developed analytical method is recommended in pharmaceutical industry. The selected liposomal formulation integrated into gel matrix (PTX-VAL-LG) showed; nanometric size, acceptable entrapment efficiency of both PTX and VAL as well as sustained release profiles and thus, enhanced action.


Assuntos
Queimaduras , Pentoxifilina , Queimaduras/tratamento farmacológico , Proteínas HMGB , Humanos , Lipossomos/uso terapêutico , Reprodutibilidade dos Testes , Receptores Toll-Like/metabolismo , Valsartana
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 256: 119748, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-33845336

RESUMO

A hybrid Spectrofluorimetric method was developed for the simultaneous determination of binary mixtures, without prior separation steps. It coupled synchronous spectrofluorimetry with derivative ratio mathematical treatment. The method was applied successfully to quantify a new model binary mixture consisting of Valsartan (VAL) and Sacubitril (SAC). This mixture was recently approved by FDA as LCZ696. It added a great value in reducing morbidity and mortality in resistant heart failure (HF) patients. First derivative ratio synchronous fluorescence was measured at 258-295 (peak-to-peak) and 204 nm for VAL and SAC, respectively. ICH guidelines were fulfilled for the method validation. VAL and SAC showed linear responses in the range of 60-200 and 20-200 ng mL-1, respectively. The proposed method was compared, in details, with the reported ones. Its high accuracy, selectivity, simplicity and affordable cost recommend method application in large-scale routine analysis of LCZ696 tablets. Moreover, reliable application of this new integrated spectrofluorimetric method suggests expansion of its application for various therapeutic combinations and different matrices.


Assuntos
Aminobutiratos , Tetrazóis , Compostos de Bifenilo , Combinação de Medicamentos , Humanos , Espectrometria de Fluorescência , Comprimidos , Valsartana
6.
Artigo em Inglês | MEDLINE | ID: mdl-32947189

RESUMO

As an anticoagulant, Edoxaban (EDX) is a high risk drug that may cause a life-threatening bleeding. Also, it is prescribed as a chronic therapy for atrial fibrillation and venous thromboembolism patients. They are special population that needs appropriate care and optimum dosing of EDX. Hence, its monitoring in the patient plasma is fundamental, especially in emergency and special circumstances. However, such patient mostly receives many drugs of different pharmacological classes, side by side with EDX. This study represents the first attempt to quantify EDX in plasma without interference of the plasma matrix or concomitant medications. An accurate RP-HPLC-DAD method was developed for this purpose. It succeeded to monitor EDX level, selectively, without interference of plasma matrix or 16 of its frequently co-administered drugs. All drugs were extracted from plasma samples by protein precipitation followed by evaporation and concentration. EDX was well resolved from the co-administered drugs on C8 column using linear gradient elution of methanol and phosphate buffer (pH 4), at a flow rate of 1 mL/min. EDX appeared at retention time 9.6 min and was quantified at its λmax (290 nm). It exhibited a linear response over the concentration range of 0.15-2.2 µg/mL plasma which covers the reported therapeutic concentration. The suggested method fulfilled the US FDA guidelines for bioanalytical method validation. The developed method is fully discussed in comparison with the reported techniques. An in vivo study was performed to ensure applicability of the method on real plasma samples without interference from plasma matrix, co-administered drugs or the expected metabolites. It presented a unique selectivity of the method that guarantees accurate laboratory monitoring of EDX in plasma in almost all combined treatments including such novel oral anticoagulant drug.


Assuntos
Anticoagulantes/sangue , Cromatografia Líquida de Alta Pressão/métodos , Piridinas/sangue , Tiazóis/sangue , Administração Oral , Animais , Anticoagulantes/administração & dosagem , Anticoagulantes/isolamento & purificação , Modelos Lineares , Masculino , Piridinas/administração & dosagem , Piridinas/isolamento & purificação , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tiazóis/administração & dosagem , Tiazóis/isolamento & purificação
7.
Talanta ; 194: 542-547, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30609570

RESUMO

A simple offline coupling voltammetry-MALDI/TOF MS procedure is presented for studying electrochemical reactions. It was utilized for the characterization of the electro-reduction products of febuxostat in methanolic acetate buffer (0.1 M, pH 5). The MS analysis reveals that the carboxylic and nitrile groups are the electro-reducible groups at -0.9338 and -1.5503 V with the conversion to aldehydic and amino groups, respectively. The developed voltammetric method was validated and applied successfully for the drug determination in pharmaceutical tablets and real plasma samples within the linearity ranges 0.03-2 and 0.4-5 µg mL-1, respectively.


Assuntos
Análise Química do Sangue/métodos , Eletroquímica/métodos , Febuxostat/sangue , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Ácidos Carboxílicos/química , Febuxostat/química , Febuxostat/metabolismo , Humanos , Nitrilas/química , Xantina Oxidase/metabolismo
8.
Drug Dev Ind Pharm ; 45(2): 265-272, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30307339

RESUMO

Objective and Significance: Methocarbamol (MET) and aspirin (ASP) are widely used as a muscle relaxant combination. The USP reports guaifenesin (GUA) and salicylic acid (SAL) as related substances and hydrolytic products of MET and ASP, respectively. This work aimed at developing and validating a simple and sensitive RP-HPLC method for the determination of both drugs as well as their related substances (at their pharmacopeial limits) in their bulk powders, laboratory prepared mixtures, and MET-ASP combined tablets. Methods and Results: Chromatographic separation was achieved in less than 9 min with the required resolution, peak symmetry, and accuracy on C18 column using isocratic elution system of diluted acetic acid (pH 3.2): acetonitrile at the ratio of 79: 21, v/v, at a flow rate of 1 mL/min. Detection was achieved with photodiode array at 233 nm for MET, GUA, and SAL and at 273 nm for ASP. The developed method has been validated as per ICH guidelines and the calibration plots were linear over the concentration ranges of 2-150, 0.4-30, 25-450, and 0.2-27 µg/mL for MET, GUA, ASP, and SAL, respectively. Conclusion: The optimized method proved to be specific, robust and precise for the quality control of the studied drugs in pharmaceutical preparations to ascertain that their related substances are not exceeding the permitted pharmacopeial limits.


Assuntos
Aspirina/análise , Metocarbamol/análise , Ácido Acético , Acetonitrilas , Calibragem , Cromatografia Líquida de Alta Pressão , Combinação de Medicamentos , Guaifenesina/análise , Limite de Detecção , Pós , Padrões de Referência , Reprodutibilidade dos Testes , Ácido Salicílico/análise , Comprimidos
9.
Bioanalysis ; 11(1): 41-54, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30475064

RESUMO

AIM: To develop a simple HPLC-DAD method for simultaneous determination of febuxostat (FEB) and diclofenac (DIC) in biological samples to assess pharmacokinetic outcomes of their coadministration. Methodology & results: Sample preparation was performed by liquid-liquid extraction. Drugs analysis was done on C18 column using methanol-formic acid pH 2.1 (76:24, v/v) as mobile phase and time-programmed UV detection. Lower limits of quantitation for FEB and DIC were 10 and 20 ng/ml, respectively. Baseline pharmacokinetics were similar to published data on either drug alone. Coadministration led to more than twofold increase in FEB Cmax and AUC together with a reduced hepatic uptake in rats. CONCLUSION: DIC interfered with initial distribution and terminal clearance of FEB potentially due to reduced FEB hepatic uptake.


Assuntos
Diclofenaco/farmacocinética , Febuxostat/farmacocinética , Fígado/metabolismo , Adulto , Animais , Área Sob a Curva , Calibragem , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Diclofenaco/administração & dosagem , Diclofenaco/sangue , Febuxostat/administração & dosagem , Febuxostat/sangue , Voluntários Saudáveis , Humanos , Extração Líquido-Líquido , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
10.
Artigo em Inglês | MEDLINE | ID: mdl-29660667

RESUMO

Two simple, sensitive and specific high-performance thin-layer chromatographic (HPTLC) methods were developed for the determination of febuxostat (FEB) individually, and simultaneously with diclofenac (DIC) in human plasma. Method A presents the first HPTLC-ultraviolet attempt for FEB determination in human plasma. FEB was separated from endogenous plasma components (at hRF = 70) with ethyl acetate-methanol-water (9:2:1, v/v) mixture as mobile phase and quantified by densitometry at its λmax (315 nm). Method B is considered the first attempt for the simultaneous determination of FEB and DIC in human plasma. A mixture of petroleum ether-chloroform-ethyl acetate-formic acid (7.5:1:2.5:0.25, v/v) was used as the mobile phase. The two drugs were separated at hRF of 39 and 60 for FEB and DIC, respectively. FEB and DIC were quantified by densitometry at their isoabsorptive point (289 nm). FEB calibration plots were linear between 0.1 and 7 µg mL-1 in both methods A and B. In method B, DIC showed linear response in the range of 0.08-8 µg mL-1. Sample preparation was performed by liquid-liquid extraction using diethyl ether. Both methods did not record any interference from plasma matrix, the studied drugs' metabolites or their decomposition products. They were successfully applied for the determination of the studied drugs in healthy male volunteers after oral administration of FEB or FEB/DIC dosage forms. FEB plasma concentration increased significantly when given with DIC. The proposed methods provided very simple, rapid and cheap approaches that might be attractive for the future pharmacokinetic and bioavailability studies of FEB and/or DIC.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Camada Fina/métodos , Diclofenaco/sangue , Febuxostat/sangue , Adolescente , Adulto , Estudos Cross-Over , Humanos , Modelos Lineares , Extração Líquido-Líquido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
11.
J Chromatogr Sci ; 54(7): 1146-52, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27406127

RESUMO

An accurate, precise, rapid, specific and economic high-performance thin-layer chromatographic (HPTLC) method has been developed for the simultaneous quantitative determination of febuxostat (FEB) and diclofenac potassium (DIC). The chromatographic separation was performed on precoated silica gel 60 GF254 plates with chloroform-methanol 7:3 (v/v) as the mobile phase. The developed plates were scanned and quantified at 289 nm. Experimental conditions including band size, mobile phase composition and chamber-saturation time were critically studied, and the optimum conditions were selected. A satisfactory resolution (Rs = 2.67) with RF 0.48 and 0.69 and high sensitivity with limits of detection of 4 and 7 ng/band for FEB and DIC, respectively, were obtained. In addition, derivative ratio and ratio difference spectrophotometric methods were established for the analysis of such a mixture. All methods were validated as per the ICH guidelines. In the HPTLC method, the calibration plots were linear between 0.01-0.55 and 0.02-0.60 µg/band, for FEB and DIC, respectively. For the spectrophotometric methods, the calibration graphs were linear between 2-14 and 4-18 µg/mL for FEB and DIC, respectively. The simplicity and specificity of the proposed methods suggest their application in quality control analysis of FEB and DIC in their raw materials and tablets. A comparison of the proposed methods with the existing methods is presented.


Assuntos
Cromatografia em Camada Fina/normas , Diclofenaco/isolamento & purificação , Febuxostat/isolamento & purificação , Comprimidos/análise , Calibragem , Clorofórmio , Cromatografia em Camada Fina/métodos , Limite de Detecção , Metanol , Reprodutibilidade dos Testes , Solventes , Comprimidos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA