Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(9): e30745, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38765099

RESUMO

The zeolitic imidazolate framework-67 (ZIF-67) has been explored for the dynamic adsorption of toluene vapor. We synthesized ZIF-67 through a straightforward room-temperature process and characterized it using XRD, FT-IR, DLS, and SEM techniques. The synthesized ZIF-67 possessed a Brunauer-Emmett-Teller (BET) surface area of 1578.7 m2/g and 0.76 µm particle size. Thermal activation under various conditions revealed that ZIF-67, activated in dry air at 250 °C, demonstrated optimal adsorption efficacy. Its adsorption capacity, time of breakthrough, and time of equilibration were 414.5 mg/g, 420 min, and 795 min, respectively. We investigated the impact of diverse operational parameters on adsorption through breakthrough curve analysis. An increase in the toluene concentration from 100 to 1000 ppm enhanced the adsorption capacity from 171 to 414 mg/g, while breakthrough time decreased from 1260 min to 462 min, respectively. Our findings show that increasing relative humidity from 0 to 70 % reduced 53.7 % in adsorption capacity and 46.3 % in breakthrough time. The competitive adsorption of toluene and ethylbenzene revealed that ZIF-67 had a higher selectivity for toluene adsorption. A 98 % adsorbent's regeneration efficiency at the first cycle reveals its reusability. The experimental data were successfully fitted to the Yan, Thomas, and Yoon-Nelson models to describe the adsorption process. The statistical validation of the model parameters confirms their reliability for estimating adsorption parameters, thus facilitating the design of fixed-bed adsorption columns for practical applications.

2.
Biomed Chromatogr ; 38(7): e5883, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38712625

RESUMO

The application of green microextraction techniques (METs) is constantly being developed in different areas including pharmaceutical, forensic, food and environmental analysis. However, they are less used in biological monitoring of workers in occupational settings. Developing valid extraction methods and analytical techniques for the determination of occupational indicators plays a critical role in the management of workers' exposure to chemicals in workplaces. Microextraction techniques have become increasingly important because they are inexpensive, robust and environmentally friendly. This study aimed to provide a comprehensive review and interpret the applications of METs and novel sorbents and liquids in biological monitoring. Future perspectives and occupational indicators that METs have not yet been developed for are also discussed.


Assuntos
Monitoramento Biológico , Microextração em Fase Líquida , Exposição Ocupacional , Microextração em Fase Sólida , Humanos , Microextração em Fase Sólida/métodos , Microextração em Fase Líquida/métodos , Monitoramento Biológico/métodos , Exposição Ocupacional/análise , Química Verde/métodos
3.
Sci Rep ; 14(1): 9935, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688900

RESUMO

Occupational exposure to toluene is associated with health risks that require reliable monitoring methods. Hippuric acid (HA), a urinary metabolite of toluene, serves as a valuable biomarker for such exposure. Colorimetric methods for the quantitative determination of HA have gained prominence due to their simplicity, cost-effectiveness, and suitability for field application. In the present study, a simple colorimetric technique was optimized for the determination of HA in the urine sample, and compared with a usual HPLC technique. The central composite design (CCD) was applied to examine the effective parameters on the colorimetric determination of HA. The calibration curve for HA was established within the concentration range of 6 to 100 mg L-1 with R2 = 0.97. The detection limit (LOD) and quantification limit (LOQ) were determined to be 1.8 mg L-1 and 6 mg L-1 respectively. The relative standard deviation (RSD%) was less than 5%, and the recovery% (R%) was 90.5-100.1. The overall results showed good agreement between the colorimetric and HPLC results. There was a significant relationship between the results obtained from HPLC and colorimetric methods especially for higher concentration levels of HA (≥ 500 mg/g creatinine). In conclusion, our optimized colorimetric method is a simple, cost-effective, and rapid method for determination of HA in occupational exposure, which is comparable with the HPLC technique.


Assuntos
Biomarcadores , Colorimetria , Hipuratos , Exposição Ocupacional , Tolueno , Hipuratos/urina , Colorimetria/métodos , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Biomarcadores/urina , Biomarcadores/análise , Tolueno/análise , Tolueno/urina , Exposição Ocupacional/análise , Limite de Detecção
4.
Toxicol Lett ; 395: 26-39, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38513876

RESUMO

This cross-sectional study was performed to assess whether systemic inflammatory indices, including systemic inflammation response index (SIRI), systemic immune­inflammation index (SII), and aggregate index of systemic inflammation (AISI), can be considered as possible inflammatory markers in silica-exposed workers with no diagnosis of silicosis. We studied 371 non-silicotic workers exposed to respirable silica dust (RSD) and 1422 reference workers. The workers' exposure to RSD were assessed and the inflammatory indices were compared between subgroups of the exposed workers based on the severity and duration of exposure. Correlations between inflammatory indices and the pulmonary function parameters were investigated. Also, the receiver operating characteristic (ROC) curve and Youden index were used to determine the cut-off values of the SII, SIRI, and AISI. Significant dose-response relationships were observed between duration of exposure and all indices except monocytes and LMR. No significant interaction was observed between duration of exposure to RSD and smoking. Borderline significant correlations were observed between AISI and SIRI with forced expiratory volume (FEV1) and FEV1 to forced vital capacity (FVC) ratio. Higher AUCs were obtained for SII and AISI, respectively. The cut-off values for these biomarkers to be considered abnormal were > 348.48 for SII, > 183.78 for AISI, and > 0.768 for SIRI. Overall, the present study showed for the first time, that SII, AISI, and SIRI might be considered as available, easy-to-obtain, and non-expensive markers of inflammation in non-silicotic workers with a long duration of exposure to RSD who are at risk of developing silicosis in subsequent years.


Assuntos
Exposição Ocupacional , Silicose , Humanos , Poeira , Estudos Transversais , Exposição Ocupacional/efeitos adversos , Dióxido de Silício/toxicidade , Silicose/diagnóstico , Silicose/etiologia , Inflamação/induzido quimicamente , Inflamação/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA