Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Heart Vessels ; 39(8): 735-745, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38526753

RESUMO

BACKGROUND: Murray law-based quantitative flow ratio (µQFR) is a novel computational method that enables accurate estimation of fractional flow reserve (FFR) using a single angiographic projection. However, its diagnostic value in patients with severe aortic stenosis (AS) remains unclear. METHOD: We included 25 consecutive patients who underwent transcatheter aortic valve replacement (TAVR) for severe AS with intermediate or greater (30-90%) coronary artery disease (CAD). Pre- and post-TAVR µQFR, QFR, instantaneous flow reserve (iFR), and post-TAVR invasive FFR values were measured. We evaluated the diagnostic performance of pre-TAVR µQFR, QFR, and iFR using post-TAVR FFR ≤ 0.80 as a reference standard of ischemia. RESULT: Pre-TAVR µQFR was significantly correlated with post-TAVR FFR (r = 0.73, p < 0.0001). The area under the curve of pre-TAVR µQFR on post-TAVR FFR ≤ 0.8 was 0.91 (95% confidence interval [CI] 0.77-0.98), comparable to that of pre-TAVR iFR (0.86 [95% CI 0.71-0.98], p = 0.97). The accuracy, sensitivity, specificity, and positive and negative predictive values of pre-TAVR µQFR on post-TAVR FFR ≤ 0.8 were 84.2% (95% CI 68.7-93.4), 61.6% (95% CI 31.6-86.1), 96.0% (95% CI 79.6-99.9), 88.9% (95% CI 52.9-98.3), and 82.8% (95% CI 70.6-90.6), respectively. For pre-TAVR iFR, these values were 76.5% (95% CI 58.8-89.3), 90.9% (95% CI 58.7-99.8), 69.6% (95% CI 47.1-86.8), 58.8% (95% CI 42.8-73.1), and 94.1% (95% CI 70.8-99.1), respectively. CONCLUSION: µQFR could be useful for the physiological evaluation of patients with severe AS with concomitant CAD.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Masculino , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA