Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38970594

RESUMO

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

2.
J Clin Med ; 13(12)2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38929915

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as an alternative treatment option for patients with severe aortic stenosis regardless of surgical risk, particularly in those with a high and prohibitive risk. Since the advent of TAVR, transfemoral access has been the standard of care. However, given comorbidities and anatomical limitations, a proportion of patients are not good candidates for a transfemoral approach. Alternative access, including transapical, transaortic, transaxillary, transsubclavian, transcarotid, and transcaval, can be considered. Each alternative access has advantages and disadvantages, so the vascular route should be tailored to the patient's characteristics. However, there is no standardized algorithm when choosing the optimal alternative vascular access. In this review, we analyzed the evolution and current evidence for the most common alternative access for TAVR and proposed an algorithm for choosing the optimal vascular access in this patient population.

4.
Eur J Heart Fail ; 26(4): 1065-1077, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606485

RESUMO

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.


Assuntos
Seio Coronário , Estudos de Viabilidade , Átrios do Coração , Insuficiência Cardíaca , Volume Sistólico , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/terapia , Feminino , Masculino , Volume Sistólico/fisiologia , Idoso , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Seio Coronário/fisiopatologia , Resultado do Tratamento , Pessoa de Meia-Idade , Ecocardiografia/métodos , Qualidade de Vida , Cateterismo Cardíaco/métodos , Estudos Prospectivos , Função Ventricular Esquerda/fisiologia , Seguimentos , Hemodinâmica/fisiologia
5.
Interv Cardiol Clin ; 13(2): 227-235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432765

RESUMO

Mitral valve dysfunction is prevalent amongst older patients. Of those not suitable for surgical therapy, mitral transcatheter edge-to-edge repair (TEER) can treat as large proportion of patients, many are not suitable TEER candidates. As such, orthotopic transcatheter mitral valve replacement (TMVR) is an important innovation but it faces significant challenges. Orthotopic TMVR requires a prosthesis with stable anchoring, adequate sealing, minimal footprint in the left ventricle and long term durability. Multidisciplinary expertise in advanced imaging, surgery, heart failure are needed for success.


Assuntos
Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ventrículos do Coração , Implantação de Prótese
6.
7.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Struct Heart ; 8(1): 100234, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283574

RESUMO

In 2022, the Food and Drug Administration approved a second mitral transcatheter edge-to-edge repair device for the treatment of primary mitral regurgitation (PASCAL Precision Transcatheter Valve Repair System, Edwards Lifesciences, Irvine, CA). The PASCAL Precision system consists of a guide sheath, implant system, and accessories. The implant system consists of a steerable catheter, an implant catheter, and the implant (PASCAL or PASCAL Ace). The guide sheath and steerable catheter move and flex independently from each other and are not keyed, allowing for freedom of rotation in three dimensions. This manuscript provides an overview of the PASCAL Precision system and describes the basic and advanced steering maneuvers to facilitate effective and safe mitral transcatheter edge-to-edge repair.

9.
Am J Cardiol ; 213: 99-105, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38110022

RESUMO

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Resultado do Tratamento , Sistema de Registros , América do Norte
10.
J Am Heart Assoc ; 12(24): e032806, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38084721
11.
J Interv Cardiol ; 2023: 6617035, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38149109

RESUMO

Background: Despite an association between operator volumes and procedural success, there remains an incomplete understanding of the contemporary utilization and procedural volumes for mitral valve transcatheter edge-to-edge repair (MTEER). We aimed to identify annual operator procedural volumes, temporal trends, and geographic variability for MTEER among Medicare patients in the United States (US). Methods: We queried the National Medicare Provider Utilization and Payment Database for a CPT code (33418) specific for MitraClip device from 2015 through 2019. We analyzed annual operator procedural volumes and incidence and identified longitudinal and geographic trends in MTEER utilization. Results: From 2015 through 2019, a total of 27,034 MTEER procedures were performed among Medicare patients in the US. The nationwide incidence increased from 6.2 per 100,000 patients in 2015 to 23.8 per 100,000 patients in 2019, a 283% increase over the study period (Ptrend < 0.001). The incidence of MTEER by state varied by nearly 900% (range 5.5 to 54.9 per 100,000 person-years). In 2019, the mean annual MTEER operator annual volume was 9.1 MTEER procedures and had grown from 6.2 per year in 2015. Conclusions: In this nationwide study of Medicare beneficiaries in the United States, we identified a significant and sustained increase in the utilization of MTEER devices and operators and growth in annual procedural volumes from 2015 through 2019 with considerable variability in utilization by state. Further studies are needed to understand the clinical impact of variability in utilization and the optimal procedural volumes to ensure high efficacy outcomes and maintain critical access to MTEER therapies.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Humanos , Estados Unidos/epidemiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Medicare , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco
12.
Artigo em Inglês | MEDLINE | ID: mdl-37962288

RESUMO

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

13.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-37930776

RESUMO

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença
14.
JACC Cardiovasc Interv ; 16(23): 2868-2879, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37902145

RESUMO

BACKGROUND: High surgical risk may preclude mitral valve replacement in many patients. Transcatheter mitral valve replacement (TMVR) using transfemoral transseptal access is a novel technology for the treatment of mitral regurgitation (MR) in high-risk surgical patients. OBJECTIVES: This analysis evaluates 30-day and 1-year outcomes of the Intrepid TMVR Early Feasibility Study in patients with ≥moderate-severe MR. METHODS: The Intrepid TMVR Early Feasibility Study is a multicenter, prospective, single-arm study. Clinical events were adjudicated by a clinical events committee; endpoints were defined according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 33 patients, enrolled at 9 U.S. sites between February 2020 and August 2022, were included. The median age was 80 years, 63.6% of patients were men, and mean Society of Thoracic Surgeons Predicted Risk of Mortality for mitral valve replacement was 5.3%. Thirty-one (93.9%) patients were successfully implanted. Median postprocedural hospitalization length of stay was 5 days, and 87.9% of patients were discharged to home. At 30 days, there were no deaths or strokes, 8 (24.2%) patients had major vascular complications and none required surgical intervention, there were 4 cases of venous thromboembolism all successfully treated without sequelae, and 1 patient had mitral valve reintervention for severe left ventricular outflow tract obstruction. At 1 year, the Kaplan-Meier all-cause mortality rate was 6.7%, echocardiography showed ≤mild valvular MR, there was no/trace paravalvular leak in all patients, median mitral valve mean gradient was 4.6 mm Hg (Q1-Q3: 3.9-5.3 mm Hg), and 91.7% of survivors were in NYHA functional class I/II with a median 11.4-point improvement in Kansas City Cardiomyopathy Questionnaire overall summary scores. CONCLUSIONS: The early benefits of the Intrepid transfemoral transseptal TMVR system were maintained up to 1 year with low mortality, low reintervention, and near complete elimination of MR, demonstrating a favorable safety profile and durable valve function.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso de 80 Anos ou mais , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos de Viabilidade , Estudos Prospectivos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia
15.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37905772

RESUMO

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Mitral , Humanos , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Ensaios Clínicos como Assunto
18.
Struct Heart ; 7(5): 100204, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37745681
20.
J Invasive Cardiol ; 35(6): E291-E293, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37410745

RESUMO

Chest radiation therapy (XRT) has been associated with a higher rate of mortality following surgical aortic valve replacement. We performed a single-center retrospective analysis of patients with severe AS who underwent TAVI from January 1 2012 to July 31 2020 comparing patients with and without XRT. A total of 915 patients met inclusion criteria, with a total of 50 patients found to have a history of XRT. At a mean follow-up of 2.4 years, unadjusted and propensity score matching analysis demonstrated no differences in mortality, heart failure or bleeding-related hospitalization, overall stroke, and 30-day pacemaker implantation in patients with and without XRT.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Pontuação de Propensão , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA