Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Int Biomech ; 9(1): 27-32, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36403162

RESUMO

Intraoperative proximal femoral fractures (IPFF) represent a rare but challenging complication of total hip arthroplasties. They usually occur as a longitudinal split. This pilot trial aimed to compare the biomechanical primary stability of different fixation techniques for IPFF. Standardised longitudinal medial split fractures of the proximal femur (type II, Modified Mallory Classification) were created in artificial osteoporotic and non-osteoporotic composite femora after implantation of a cementless femoral stem. Five different fixation techniques were compared: cerclage band, cerclage wiring with one or two wires, and lag screw fixation with one or two lag screws. A quasi-static loading protocol was applied and failure loads were evaluated. The observed median failure loads were 4192N (3982N - 5189N) for one cerclage band, 4450N (3577N - 4927N) for one cerclage wire, 5016N (4175N - 5685N) for two cerclage wires, 6085N (5000N - 8907N) for one lag screw, and 4774N (4509N - 8502N) for two lag screws. Due to the wide range of failure loads within the experimental groups, there were no observable differences between the groups. All fixation techniques provided sufficient primary stability in osteoporotic and non-osteoporotic composite bones. Further cadaveric studies with larger sample sizes may be needed to confirm the results presented here.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Complicações Intraoperatórias , Humanos , Fenômenos Biomecânicos , Fios Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Complicações Intraoperatórias/cirurgia , Projetos Piloto
2.
Orthopadie (Heidelb) ; 51(7): 573-579, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35776154

RESUMO

BACKGROUND: The medical challenges caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV­2) pose a tremendous burden on the healthcare system. This study aimed to analyze the effects of a SARS-CoV­2 infections or disease progression on inpatient mortality of geriatric patients after proximal femoral fracture surgery. METHODS: A retrospective analysis was conducted in all patients with a proximal femoral fracture surgically treated in an urban regional trauma center from 01/01/2020 to 01/31/2021. According to PCR test results detecting SARS-CoV­2, the patients were divided into two groups (SARS-CoV­2 positive vs. SARS-CoV­2 negative). Patient data, disease progression data, and treatment-related information were evaluated for all patients. Statistical data analysis was performed using unpaired Student's t test or non-parametric Mann-Whitney U test. RESULTS: A total of 311 patients (women: 70.4%, age: 82.0 ± 11.0 years) were included in this study. Of these 3.9% (12/311) had a positive test result for SARS-CoV­2. Significantly more deceased patients were found in the group tested positive for SARS-CoV­2 (SARS-CoV­2 positive: 41.7%, SARS-CoV­2 negative: 5.4%, p < 0.001). In addition, the number of proximal femoral fracture associated deaths correlated with the number of positive test results performed in the Clinic. The length of stay of SARS-CoV­2 COVID-19 survivors tended to be greater than in those who were tested negative (SARS-CoV­2 COVID-19 positive: 15.6 ± 13.1 days, SARS-CoV­2 COVID-19 negative: 11.5 ± 6.5 days, p = 0.683). Furthermore, a significant difference in age was found in SARS-CoV­2 survivors and SARS-CoV­2 decedents (deceased: 95.5 ± 7.5 years, alive: 83.5 ± 7.3 years, p = 0.020). CONCLUSION: The study was conducted before the introduction of SARS-CoV­2 vaccination. The results therefore refer to immune naive (unvaccinated) patients. In our study, more than 40% of all patients with proximal femoral fractures who tested positive for SARS-CoV­2 died during hospitalization. An additional, critical factor in this respect was the age of the infected patients. Nonetheless, a positive correlation was demonstrated between the mortality rate and the number of positive SARS-CoV­2 detections. Regarding the greater length of stay of patients tested positive for SARS-CoV­2, the limited transfer options (further rehabilitation, skilled nursing facility) of the infected ones can be considered as causal. Particularly the vulnerable older patients are increasingly endangered by a combination of proximal femoral fracture and SARS-CoV­2.


Assuntos
COVID-19 , Fraturas do Fêmur , Idoso , Idoso de 80 Anos ou mais , Vacinas contra COVID-19 , Progressão da Doença , Feminino , Fraturas do Fêmur/cirurgia , Humanos , Pacientes Internados , Estudos Retrospectivos , SARS-CoV-2
3.
Int Orthop ; 46(9): 1921-1928, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35635553

RESUMO

PURPOSE: This study investigated the diagnostic value of simultaneous 18F-fluordeoxyglucose positron emission tomography/magnetic resonance imaging (PET/MRI) in suspected periprosthetic joint infection (PJI) of the hip and knee. METHODS: Sixteen prostheses from 13 patients with suspected PJI were prospectively examined using PET/MRI. Image datasets were evaluated in consensus by a radiologist and a nuclear physician for the overall diagnosis of 'PJI' (yes/no) and its anatomical involvement, such as the periprosthetic bone margin, bone marrow, and soft tissue. The imaging results were compared with the reference standard obtained from surgical or biopsy specimens and subjected to statistical analysis. RESULTS: Using the reference standard, ten out of the 13 prostheses (ten hips, threes knees) were diagnosed with PJI. Using PET/MRI, every patient with PJI was correctly diagnosed (sensitivity, 100%; specificity, 100%). Considering the anatomical regions, the sensitivity and specificity were 57% and 50% in the periprosthetic bone margin, 75% and 33% in the bone marrow, and 100% and 100% in the soft tissue. CONCLUSION: PET/MRI can be reliably used for the diagnosis of PJI. However, assessment of the periprosthetic bone remains difficult due to the presence of artefacts. Thus, currently, this modality is unlikely to be recommended in clinical practice.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Estudos de Viabilidade , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Sensibilidade e Especificidade
4.
Eur J Trauma Emerg Surg ; 48(5): 3981-3987, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35355090

RESUMO

INTRODUCTION: Dislocations of hip hemiarthroplasty (HHA) are serious complications. The aim of the study was to identify clinical aspects and radiographic parameters of the hip that put patients at risk for dislocation after HHA for femoral neck fractures. METHODS: This retrospective analysis included elderly patients with a femoral neck fracture treated with a HHA. A lateral (90.7%) and an anterolateral (9.3%) approach was applied. On pelvic radiographs, a nested-controlled analysis was performed. Two control patients were matched to one patient suffering a dislocation with respect to age, sex, and body-mass-index (BMI). RESULTS: In 527 HHA, 10 dislocations (1.9%) were identified. In the dislocation group (DG), all patients were female (100% vs. 73.5%, p = 0.071). No significant differences between the DG and the control group (CG) were found with respect to age, body-mass-index (BMI), ASA Score, routine laboratory parameters, and comorbidity. Radiographic analysis revealed a smaller center edge angle (CEA, 39.0, IQR 33.0-42.5 vs. 43.0, IQR 41.0-46.0, p = 0.013), a more varus neck-shaft angle (NSA, 130.0, IQR 125.8-133.5 vs. 135.0, IQR 134.0-137.0, p = 0.011) of the contralateral side and a higher femoral head extrusion index (FHEI) in the DG (FHEI, 11.5, IQR 9.8-16.3 vs. 2.0 IQR 0.0-9.0, p = 0.003). In addition, a greater trochanteric fracture was associated with an increased likelihood for HHA dislocations (30.0% vs 6.0%, p = 0.022). CONCLUSION: A smaller radiographic center edge angle, a more varus neck-shaft angle of the contralateral side, a higher femoral head extrusion index and intraoperative fractures of the greater trochanter are associated with an increased risk of HHA dislocation.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Luxação do Quadril , Luxações Articulares , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos de Casos e Controles , Feminino , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Humanos , Luxações Articulares/cirurgia , Masculino , Estudos Retrospectivos
5.
BMC Musculoskelet Disord ; 23(1): 40, 2022 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996409

RESUMO

BACKGROUND: Intraoperative proximal femoral fractures (IPFF) are relevant complications during total hip arthroplasty. Fixation using cerclage wires (CW) represents a minimally-invasive technique to address these fractures through the same surgical approach. The goal of treatment is to mobilise the patient as early as possible, which requires high primary stability. This study aimed to compare different cerclage wire configurations fixing IPFF with regard to biomechanical primary stability. METHODS: Standardised IPFF (type II, Modified Mallory Classification) were created in human fresh frozen femora and were fixed either by two or three CW (1.6 mm, stainless steel). All cadaveric specimens (n = 42) were randomised to different groups (quasi-static, dynamic) or subgroups (2 CW, 3 CW) stratified by bone mineral density determined by Dual Energy X-ray Absorptiometry. Using a biomechanical testing setup, quasi-static and dynamic cyclic failure tests were carried out. Cyclic loading started from 200 N to 500 N at 1 Hz with increasing peak load by 250 N every 100 cycles until failure occurred or maximum load (5250 N) reached. The change of fracture gap size was optically captured. RESULTS: No significant differences in failure load after quasi-static (p = 0.701) or dynamic cyclic loading (p = 0.132) were found between the experimental groups. In the quasi-static load testing, all constructs resisted 250% of the body weight (BW) of their corresponding body donor. In the dynamic cyclic load testing, all but one construct (treated by 3 CW) resisted 250% BW. CONCLUSIONS: Based on this in vitro data, both two and three CW provided sufficient primary stability according to the predefined minimum failure load (250% BW) to resist. The authors recommend the treatment using two CW because it reduces the risk of vascular injury and shortens procedure time.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Fios Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Humanos
6.
Eur J Trauma Emerg Surg ; 48(3): 1835-1840, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33313961

RESUMO

PURPOSE: Hemiarthroplasty is widely accepted as the treatment of choice in elderly patients with a displaced intracapsular femoral neck fracture. Intraoperative greater trochanteric fractures thwart this successful procedure, resulting in prolonged recovery, inferior outcome, and increased risk of revision surgery. Hence, this study analyzed factors potentially associated with an increased risk for intraoperative greater trochanteric fracture. METHODS: This retrospective study included 512 hemiarthroplasties in 496 patients with a geriatric intracapsular femoral neck fracture from July 2010 to March 2020. All patients received the same implant type of which 90.4% were cemented and 9.6% non-cemented. Intra- and postoperative radiographs and reports were reviewed and particularly screened for greater trochanteric fractures. RESULTS: Female patients accounted for 74% and mean age of the patients was 82.3 (± 8.7) years. 34 (6.6%) intraoperative greater trochanteric fractures were identified. In relation to patient-specific factors, only a shorter prothrombin time was found to be significantly associated with increased risk of intraoperative greater trochanteric fracture (median 96%, IQR 82-106% vs. median 86.5%, IQR 68.8-101.5%; p = 0.046). Other factors associated with greater trochanteric fracture were a shorter preoperative waiting time and changes in perioperative settings. Outcome of patients with greater trochanteric fracture was worse with significantly more surgical site infection requiring revision surgery (17.6% vs. 4.2%, p = 0.005). CONCLUSION: Prolonged prothrombin time, a shorter preoperative waiting time, and implementing new procedural standards and surgeons may be associated with an increased risk of a greater trochanteric fracture. Addressing these risk factors may reduce early periprosthetic infection which is strongly related to greater trochanteric fractures.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Fraturas do Quadril , Prótese de Quadril , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/efeitos adversos , Fraturas do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Complicações Intraoperatórias , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
7.
Z Orthop Unfall ; 160(3): 317-323, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33540460

RESUMO

INTRODUCTION: Revision arthroplasty involving mega-implants is associated with a high complication rate. In particular, infection is a serious complication of revision arthroplasty of hip and knee joints and has been reported to have an average rate of 18%, and for mega-implants, the range is from 3 to 36%. This study was designed to analyze the strategy of treatment of infection of mega-endoprostheses of the lower extremities in our patient cohort, particularly the management of chronic infection. MATERIAL AND METHODS: This was a retrospective study that focused on the results of the treatment of periprosthetic infections of mega-implants of the lower extremities. We identified 26 cases with periprosthetic infections out of 212 patients with 220 modular mega-endoprostheses of the lower extremities who were treated in our department between September 2013 and September 2019. As a reinfection or recurrence, we defined clinical and microbiological recurrences of local periprosthetic joint infections after an antibiotic-free period. RESULTS: In this study, 200 cases out of 220 were investigated. The average follow-up period was approximately 18 months (6 months to 6 years). Endoprosthesis infections after implantation of mega-implants occurred in 26 cases (13%). This group comprised 2 early infections (within the first 4 weeks) and 24 chronic infections (between 10 weeks and 6 years after implantation). Nineteen cases out of the identified 26 cases with infection (73.1%) belong to the group of patients who were operated on due to major bone loss following explantation of endoprosthetic components due to previous periprosthetic joint infection. The remaining seven cases with infection comprised four cases following management of periprosthetic fracture, two cases following treatment of aseptic loosening, and one case following tumor resection. All infections were treated surgically. In all cases, the duration of continuous antibiotic treatment did not exceed 6 weeks. Both cases with early infection were treated by exchanging polyethylene inlays and performing debridement with lavage (two cases). In two (7.7%) cases with chronic infection, one-stage surgery was performed. In all remaining cases with chronic infection (22 cases; 84.6%), explantation of all components and temporary implantation of cement spacers were carried out prior to reimplantation. CONCLUSION: There is still no gold standard therapeutic regimen for the management of periprosthetic infection of mega-implants, though radical surgical debridement and lavage accompanied by systemic antibiotic therapy are the most important therapeutic tools in all cases of periprosthetic infections, regardless of the time of onset. Further studies are needed to standardize management strategies of such infections. Nevertheless, it is not uncommon for compromises to be made based on the particular condition of the individual.


Assuntos
Artroplastia de Quadril , Fraturas Periprotéticas , Infecções Relacionadas à Prótese , Antibacterianos/uso terapêutico , Artroplastia de Quadril/métodos , Humanos , Extremidade Inferior/cirurgia , Fraturas Periprotéticas/cirurgia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação/métodos , Estudos Retrospectivos
8.
Clin Biomech (Bristol, Avon) ; 82: 105280, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33582564

RESUMO

BACKGROUND: The femoral head is of central importance for the force transmission from the suprapelvic body mass to the lower extremity. However, the condition of the subcortical bone and its mechanical properties in case of pathological changes due to coxarthrosis or femoral head necrosis differ from the healthy condition. METHODS: Fresh femoral heads were gathered during hip total endoprosthesis surgeries and cylindrical cancellous bone samples were extracted with a hollow drill. By means of a uniaxial tensile-compression test system, the compressive strength was determined for two different specimen types (fresh and 24 h storage in acetone). Exemplary tests on an exceptionally large femoral head were performed to compare properties of fresh, fresh-deep-frozen and acetone-stored samples. FINDINGS: The deformation behaviour and the material parameters determined were very heterogeneous. For most of the specimens, a destructive material test was successfully carried out, i.e. the compressive strength was determined. The average strength of fresh specimens was slightly higher than that of acetone specimens. On the other hand, the average Young's modulus of the acetone specimens was higher than that of the fresh specimens. INTERPRETATION: The lower Young's moodulus of the fresh samples compared to the acetone samples could indicate a causal effect of the degreasing influence of the acetone. The partly considerable individual differences in compressive strength and failure compression can have patient-specific influencing factors such as constitution and physical fitness as well as causes in the initial pathological condition.


Assuntos
Osso Esponjoso/cirurgia , Cabeça do Fêmur/cirurgia , Fenômenos Mecânicos , Procedimentos Ortopédicos , Fenômenos Biomecânicos , Humanos
9.
Orthopade ; 50(3): 188-197, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32424439

RESUMO

BACKGROUND: Malnutrition caused by protein and vitamin deficiencies is a significant negative prognostic factor in surgical wound healing disorders and infections. Particularly in elective surgery, preoperative compensation of deficiencies is advisable to avoid negative postoperative consequences. This study examined the nutritional and protein balance of patients with periprosthetic hip and knee joint infections. MATERIAL AND METHODS: Patients with periprosthetic hip or knee joint infections constituted the study group (SG). Control group I (CG I) included patients with primary implants and CG II included patients who required revision surgery because of aseptic loosening. Relevant nutritional and protein parameters were determined via analysis of peripheral venous blood samples. In addition, a questionnaire was used to evaluate the nutritional and eating patterns of all patients. The nutritional risk screening (NRS) 2002 score and body mass index (BMI) were also calculated for all participants. RESULTS: Differences were found in the albumin level (SG: 36.23 ± 7.34, CG I: 44.37 ± 3.32, p < 0.001, CG II: 44.06 ± 4.24, p < 0.001) and total protein in serum (SG: 65.42 ± 8.66, CG I: 70.80 ± 5.33, p = 0.004, CG II: 71.22 ± 5.21, p = 0.004). The number of patients with lowered albumin levels (SG 19/61, CG I 1/78, CG II 2/55) and total protein in serum (SG: 12/61, CG I 5/78, CG II 2/55) also showed considerable variation. The number of patients with a NRS 2002 score ≥3 differed significantly between SG and both CGs (SG: 5/61, CG I 1/78, CG II 0/55); however, these differences could not be confirmed using BMI. CONCLUSION: As expected, lowered albumin and total protein levels were observed in PJI due to the acute phase reaction. The NRS can be performed to exclude nutritional deficiency, which cannot be excluded based on BMI. In cases of periprosthetic joint infection it is reasonable to compensate the nutritional deficiency with dietary supplements.


Assuntos
Artrite Infecciosa , Infecções Relacionadas à Prótese , Humanos , Estado Nutricional , Reoperação , Estudos Retrospectivos
10.
Eur J Trauma Emerg Surg ; 47(1): 211-216, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31520158

RESUMO

INTRODUCTION: In addition to abrasion-induced osteolysis and ensuing instabilities, the polyethylene (PE) abrasion of total hip arthroplasty (THA) inlays can also cause gait instability due to the decentralization of the hip joint. The current literature yields, as yet, insufficient findings whether these two factors are linked directly or indirectly to a higher risk for periprosthetic proximal femoral fractures (PPFF). The aim of our retrospective evaluation is to analyse the impact of PE abrasion on the pathology of PPFF in patients with THA. MATERIAL AND METHODS: The retrospective evaluation comprises all PPFF in patients with THA in the period from 01/2010 up to 12/2016. The study group (SG) included 66 cases (n = 66). The control group (CG) was comprised of patients with asymptomatic THA (n = 66), who were treated by our outpatient department including routine check-ups and X-ray examinations. We used the matched-pair methodology to scale the period of postsurgical care of the CG to the lifetime of the implant up to PPFF in the SG. We included epidemiologic data, radiological femoral head decentralization, osteolysis (Gruen classification), instabilities, acetabular cup position, and implant properties in our analysis. For the SG, we also included intra-operative signs of abrasion. FINDINGS: The SG showed significantly higher numbers of decentralized THA as signs of inlay erosion with 73% compared to only 41% in the CG (p > 0.001). The SG showed 1 ± 0.68 mm hip joint decentralization as to 0.5 ± 0.59 mm in the CG (p = 0.004). We found significantly more cases of osteolysis in the SG (n = 25) than in the CG (n = 13) (p = 0.003). We found no notable differences in acetabular cup inclination or anteversion as well as cup size. However, differences were significant in femoral head size (SG 32 ± 2.3 mm, CG 36 ± 2.4 mm; p = 0.042) and head material. We found more widespread use of metal femoral heads in the SG than in the CG (SG 1:1, CG 1:21; p = 0.001). CONCLUSION: PPFF patients showed significantly higher rates of inlay erosion, resulting in femoral head decentralization and osteolysis. The higher rate of fracture is likely caused by the increasing instability of the implant fixation due to abrasion-induced osteolysis and the associated degradation of bone quality. It is conceivable that the abrasion and decentralization of the THA can also lead to gait instability, and thus, a higher proneness to falls. Gait instability can also be aggravated by increased granulation tissue and effusion due to the inlay abrasion. Although this cannot be substantiated by the investigation. In patients with decentralization of the THA and osteolysis, a radiological follow-up should be performed, and in case of gait instability (femoral head and) inlay replacements should be considered.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur/etiologia , Prótese de Quadril/efeitos adversos , Osteólise/etiologia , Polietileno/efeitos adversos , Idoso , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos
11.
Arthroplasty ; 3(1): 20, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35236493

RESUMO

BACKGROUND: All current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly influenced by the applied impulse and surrounding soft tissues. This leads to large differences in assembly forces between the surgeries. This study aimed to quantify the assembly forces of different surgeons under influence of surrounding soft tissue. METHODS: First, a measuring system, consisting of a prosthesis and a hammer, was developed. Both components are equipped with a piezoelectric force sensor. Initially, in situ experiments on human cadavers were carried out using this system in order to determine the actual assembly forces and to characterize the influence of human soft tissues. Afterwards, an in vitro model in the form of an artificial femur (Sawbones Europe AB, Malmo, Sweden) with implanted measuring stem embedded in gelatine was developed. The gelatine mixture was chosen in such a way that assembly forces applied to the model corresponded to those in situ. A study involving 31 surgeons was carried out on the aforementioned in vitro model, in which the assembly forces were determined. RESULTS: A model was developed, with the influence of human soft tissues being taken into account. The assembly forces measured on the in vitro model were, on average, 2037.2 N ± 724.9 N, ranging from 822.5 N to 3835.2 N. The comparison among the surgeons showed no significant differences in sex (P = 0.09), work experience (P = 0.71) and number of THAs performed per year (P = 0.69). CONCLUSIONS: All measured assembly forces were below 4 kN, which is recommended in the literature. This could lead to increased corrosion following fretting in the head-neck interface. In addition, there was a very wide range of assembly forces among the surgeons, although other influencing factors such as different implant sizes or materials were not taken into account. To ensure optimal assembly force, the impaction should be standardized, e.g., by using an appropriate surgical instrument.

12.
Orthopade ; 50(9): 750-757, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33084914

RESUMO

BACKGROUND: This study examined the clinical outcome following revision arthroplasty of the knee joint and severe arthrosis with metaphyseal bone defects and instability using metaphyseal sleeves. We analyzed the results based on established scores and recorded the complications occurring on revision arthroplasty. MATERIAL AND METHODS: Patients with revision arthroplasty of the knee and metaphyseal bone defects grade III according to the Anderson Orthopedic Research Institute (AORI) classification were included (16 patients, 9 females and 7 males). In all cases, surgery was performed using an endoprosthesis COMPLETE™ revision knee system with metaphyseal sleeves. RESULTS: All patients had a significant reduction in pain level after revision surgery. The median HSS score in the cohort with primary arthroplasty was 84 and in the cohort with revision arthroplasty 73 and the KSS was 83 and 55, respectively. According to the HSS an excellent result was achieved by 50% of the patients in the primary arthroplasty group and 25% in the revision group. Only three patients were considered to have an insufficient result. Postoperative pain was significantly reduced in both groups. The median ROM was 112° flexion in the primary arthroplasty group and 95° in the revision group. An extension deficit was observed in three patients and four patients showed prolonged wound healing postoperatively (25%), which was treated conservatively and did not lead to septic changes. CONCLUSION: The use of metaphyseal sleeves in patients with bone defects is a suitable instrument with no negative impact on the outcome both in primary and revision arthroplasty. Further studies with larger study groups and analysis of long-term results after use of such endoprosthetic components should be conducted.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Desenho de Prótese , Reoperação , Estudos Retrospectivos
13.
Orthopade ; 50(3): 207-213, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32666143

RESUMO

BACKGROUND: Knee joint arthrodesis is an established treatment for periprosthetic infections (PPI) providing stability and pain relief. In this study the outcome after arthrodesis of the knee joint for persistent infections was compared and evaluated depending on the surgical procedure (intramedullary vs. extramedullary). MATERIAL AND METHODS: In a retrospective case analysis, all patients who underwent knee joint arthrodesis between 1 January 2010 and 31 December 2016 were identified and divided into two groups: IMA and EMA. All patients were examined clinically and radiologically and the patient files were evaluated. In addition, the FIM score, the LEFS, the WHOQOL-BREF and NRS were evaluated. RESULTS: The median LEFS score for the IMA group was 26 points and in the EMA group 2 points (p = 0.03). The IMA patients showed a median pain scale at rest of 0 and during exercise of 2. The EMA group recorded a pain scale of 3 at rest and 5 during exercise (p = 0.28 at rest; p = 0.43 during exercise). In the IMA group the median postsurgical leg length difference was -2.0 cm and -2.5 cm in the EMA group (p = 0.31). At the end of the follow-up examinations, the FIM score of patients in the IMA group was 74.5 points and 22 points in the EMA group (p = 0.07). CONCLUSION: The study showed that no arthrodesis procedure is obviously superior with respect to the postoperative outcome. The IMA combines advantages especially in the early phase after surgery in terms of function as well as patient comfort and is therefore currently the procedure of choice. The attending physician should be familiar with the advantages and disadvantages of the various procedures in order to be able to make an individual decision and thus maximize the chance of treatment success.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Infecções Relacionadas à Prótese , Artrodese , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
14.
Orthopade ; 50(6): 455-463, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32749511

RESUMO

OBJECTIVE: The aim of this study was to evaluate the influence of the introduction of online podcasts as part of the main lecture series in orthopaedics on the number of lecture attendees, the examination results and the assessment of teaching by the students. Additionally, we evaluated the use of other media for examination preparation. METHODOLOGY: At the beginning and end of the lecture series questionnaires were handed out to the students to evaluate their attitudes towards attending lectures, the use of video podcasts and examination preparation. In addition, the number of lecture attendees and podcast usage during the semester were counted and the statements of the students in the evaluation assessments of orthopaedic teaching were evaluated. The examination results were correlated in a statistical analysis with the learning materials provided by the students for examination preparation. RESULTS: At the end of the lecture series, 284 students stated that they used the lecture podcast about twice as often as attending lectures; however, for the majority of the students the provision of a video podcast was no reason not to attend the lecture. For example, 37.2% stated that they never and 26.8% stated that they rarely had not attended the lecture by providing the podcasts. Of the students 91-95% considered the availability of lecture podcasts to be a rather meaningful or very meaningful supplement to the lecture visit. Students increasingly used digital media to prepare for examinations instead of using traditional analogue methods. None of the learning methods or materials examined showed a statistically significant advantage in examination results. CONCLUSION: Students in the age of digitalization use a variety of learning materials and are no longer bound to classical analog teaching methods. The use of online podcasts had no negative impact on examination performance. Most students perceived lecture podcasts as a useful supplement to lecture attendance. The students praised the expansion of the teaching curriculum to include additional digital offers with positive comments in the evaluations, but without achieving an improvement in these student evaluations.


Assuntos
Procedimentos Ortopédicos , Ortopedia , Currículo , Avaliação Educacional , Humanos , Internet , Inquéritos e Questionários
15.
Artigo em Inglês | MEDLINE | ID: mdl-33214984

RESUMO

Background: Periprosthetic fractures (PPF) of the femur close to the hip joint have serious consequences for most geriatric affected patients. In principle, apart from the highly uncommon conservative therapy, there are two therapeutic options. On the one hand, the prosthesis-preserving treatment by means of osteosynthesis using plates and/or cerclages in general is available. On the other hand, a (partial) change of the prosthesis with optionally additive osteosynthesis or a proximal femoral replacement can be performed because of prosthesis loosening or non-reconstructable comminuted fractures as well as most cemented stem variations. The aim of this retrospective study is the analysis of periprosthetic proximal femoral fractures in the presence of a total hip arthroplasty (THA). The outcome of the operated patients is to be investigated depending on the type of care (osteosynthesis with prosthesis preservation vs. prosthesis change). Material and methods: In a retrospective case analysis, 80 patients with THA and PPF were included. They were divided into two groups. Group I represents the osteosynthetic treatment to preserve the implanted THA (n=42). Group II (n=38) includes those patients who were treated by a change of their endoprosthesis with or without additional osteosynthesis. Specifics of all patients, like gender, age at fracture, interval between fracture and implantation, length of in-patient stay, body mass index, osteoporosis, corticomedullary index and complications such as infections, re-fracture, loosening, material failure or other complications, were recorded and compared. Furthermore, the patients were re-examined by a questionnaire and the score according to Merle d'Aubigné and Postel. Results: In group I the mean follow-up time was 48.5±23 months (4 years) whereas group II amounted 32.5±24.5 months (2.7 years) (p=0.029). Besides, there were significant differences in age (81± 11 years vs. 76±10 years, p=0.047) and length of in-patient stay (14.5±8.6 days vs. 18.0±16.7 days, p=0.014). According to the score of Merle d'Aubigné and Postel, there were significantly better values for the pain in group II with comparable values for mobility and walking ability. Conclusion: The treatment of periprosthetic proximal fractures of the femur is dependent on the classification (Vancouver and Johannsen) and in particular on the prosthetic anchoring as well as the extent of the comminution zone. Older patients and patients with osteoporosis are more frequently treated with an endoprosthesis revision. Patients, who have been treated with an osteosynthesis for preserving their endoprosthesis, showed a shorter length of in-patient stay and fewer complications than people with replacement surgery. In contrast to that, patients with prosthesis revision had better outcomes concerning the score of Merle d'Aubigné and Postel.

16.
Sci Rep ; 10(1): 14545, 2020 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-32884007

RESUMO

Total hip arthroplasty (THA) is a highly successful surgical procedure, but complications remain, including aseptic loosening, early dislocation and misalignment. These may partly be related to lacking training opportunities for novices or those performing THA less frequently. A standardized training setting with realistic haptic feedback for THA does not exist to date. Virtual Reality (VR) may help establish THA training scenarios under standardized settings, morphology and material properties. This work summarizes the development and acquisition of mechanical properties on hip reaming, resulting in a tissue-based material model of the acetabulum for force feedback VR hip reaming simulators. With the given forces and torques occurring during the reaming, Cubic Hermite Spline interpolation seemed the most suitable approach to represent the nonlinear force-displacement behavior of the acetabular tissues over Cubic Splines. Further, Cubic Hermite Splines allowed for a rapid force feedback computation below the 1 ms hallmark. The Cubic Hermite Spline material model was implemented using a three-dimensional-sphere packing model. The resulting forces were delivered via a human-machine-interaction certified KUKA iiwa robotic arm used as a force feedback device. Consequently, this novel approach presents a concept to obtain mechanical data from high-force surgical interventions as baseline data for material models and biomechanical considerations; this will allow THA surgeons to train with a variety of machining hardness levels of acetabula for haptic VR acetabulum reaming.


Assuntos
Acetábulo/cirurgia , Fenômenos Biomecânicos/fisiologia , Acetábulo/fisiologia , Artroplastia de Quadril , Simulação por Computador , Prótese de Quadril , Humanos , Realidade Virtual
17.
BMC Med Inform Decis Mak ; 20(1): 145, 2020 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-32616031

RESUMO

BACKGROUND: The design and internal layout of modern operating rooms (OR) are influencing the surgical team's collaboration and communication, ergonomics, as well as intraoperative hygiene substantially. Yet, there is no objective method for the assessment and design of operating room setups for different surgical disciplines and intervention types available. The aim of this work is to establish an improved OR setup for common procedures in arthroplasty. METHODS: With the help of computer simulation, a method for the design and assessment of enhanced OR setups was developed. New OR setups were designed, analyzed in a computer simulation environment and evaluated in the actual intraoperative setting. Thereby, a 3D graphical simulation representation enabled the strong involvement of clinical stakeholders in all phases of the design and decision-making process of the new setup alternatives. RESULTS: The implementation of improved OR setups reduces the instrument handover time between the surgeon and the scrub nurse, the travel paths of the OR team as well as shortens the procedure duration. Additionally, the ergonomics of the OR staff were improved. CONCLUSION: The developed simulation method was evaluated in the actual intraoperative setting and proved its benefit for the design and optimization of OR setups for different surgical intervention types. As a clinical result, enhanced setups for total knee arthroplasty and total hip arthroplasty surgeries were established in daily clinical routine and the OR efficiency was improved.


Assuntos
Procedimentos Ortopédicos , Simulação por Computador , Humanos , Salas Cirúrgicas , Cirurgiões , Fluxo de Trabalho
18.
Orthopade ; 49(5): 432-442, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32112227

RESUMO

BACKGROUND: The purpose of this study was to provide a practicable and contemporary classification system that is reliable and pragmatic with respect to perioperative evaluation, planning, scientific comparison and analysis. MATERIAL AND METHODS: This was a retrospective study of 160 patients who underwent acetabular revision surgery after THR due to loosening of the acetabular cup. The assessment of the acetabular defect was based on intraoperative description of the bony configuration of the acetabulum as well as on standardized preoperative planning images (pelvic overview and axial view of the hip joint). Preoperative computed tomography (CT) was carried out in individual cases. RESULTS: Acetabular bone defects were classified into 4 types based on whether or not a 3-point fixation of the acetabular cup within the boundaries of the acetabular cavity was possible. Minor segmental defects or cup loosening without bone loss can be treated with standard hemispherical acetabular components. Bone loss can be filled with bone grafts and/or treated by the appropriate acetabular component in order to ensure stable anchorage. When conventional revision cups are no longer suitable a custom made partial pelvic replacement can be used. CONCLUSION: The proposed classification mainly relies on intraoperative findings which were confirmed by preoperative imaging in 154 cases out of 160 (96.25%); however, meticulous preoperative planning based on X­ray radiographs must be carried out. In addition, a CT scan must be performed whenever type III or type IV defects are anticipated. Compared to the existing classification systems, we can state that our classification system is practicable and pragmatic and simplifies the assessment of bone defects.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Articulação do Quadril/cirurgia , Prótese de Quadril , Procedimentos de Cirurgia Plástica , Acetábulo/anormalidades , Acetábulo/diagnóstico por imagem , Diagnóstico por Imagem , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Falha de Prótese , Reoperação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Arthroplasty ; 2(1): 29, 2020 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-35236465

RESUMO

INTRODUCTION: Hip and knee arthroplasties are very frequently performed surgeries with high quality standards and continuous optimization potential. Intraoperative processes can be standardized and simplified by optimization of table setups in the operating room to improve the quality and to increase efficiency. PATIENTS AND METHODS: The existing surgical setups for primary hip and knee arthroplasties in a university maximum care hospital with endoprosthesis center were simulated and analysed with a computer program and optimized setup suggestions were worked out, based on handover times, walking distance and ergonomic aspects determined in the program. In a prospective monocentric analysis, primary hip arthroplasties and knee arthroplasties were examined in currently used and in the new optimized setups (standard procedure according to in-house SOP, senior and main surgeons, no assistants). The surgeries were externally and independently supervised and analysed, whereby the time between incision and suture beginning, handovers per minute and handover times were documented, amongst other things. In addition, an evaluation sheet, which showed the satisfaction with the new setup, was filled by the surgical team. RESULTS: In the period from April 2016 to December 2018, 19 hip arthroplasties in currently used and 15 in the new optimized setup as well as 9 knee arthroplasties in currently used and 13 in the new setup were performed. Attention was paid to constant conditions in the compared groups and disruptive factors (assisted surgeries, complex surgeries, different cementings, etc.) were excluded. In the group of hip arthroplasties, the handover times were significantly different (old 1.82 +/- 1.43 s.; new 1.08 +/- 0.78 s.; p <0.001), as well as the handovers per minute (old 1.62 +/- 0.45 handovers/min.; new 2.10 +/- 0.32 handovers/min.; p = 0,001). The time between incision and suture beginning indicated no significant difference (old 53.89 +/- 18.92 min.; new 49.73 +/- 12.18 min; p = 0.466): During the knee arthroplasties, handovers per minute were significantly different (old 1.83 +/- 0.38 handovers/min.; new 2.40 +/- 0.35 handovers/min.; p = 0.002). The time between incision and suture beginning (old 71.11 +/- 20.72 min.; new 70.69 +/- 17.12 min.; p = 0.959) and the handover times (old 1.06 +/- 0.64 s.; new 0.91 +/- 0.59 s.; p = 0.152) indicated no significant difference. The evaluation of the questionnaires showed a significant difference (p < 0.001) in the group of hip arthroplasties in the category "visibility". For the knee arthroplasties, all items except "visibility" (p = 0.261) differed significantly. Overall, a high level of staff satisfaction with the new setup was achieved. CONCLUSIONS: In both groups, more handovers per minute could be achieved in the optimized setup and in the group of the hip arthroplasties, the handover times were significantly faster. The evaluation sheet showed a high satisfaction of the surgical staff with the new setup. No reduction of the time between incision and suture beginning could be determined. This can be attributed to a certain training effect, the adjustment to the setup modification and the low number of cases. The new setup offers a practical alternative for hip arthroplasties as well as for knee arthroplasties as it optimizes the events in the operating room in many ways. For example, there were more handovers per minute possible and passing of the surgical instruments free from interferences. Moreover, it increases the efficiency and achieves a high satisfaction of the staff.

20.
Orthopade ; 48(4): 350, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30848326

RESUMO

Erratum to: Orthopäde 2018 https://doi.org/10.1007/s00132-018-03675-5 Dear Reader,in the original online version of the article "Management of pelvic discontinuity in revision hip arthroplasty using a cementless acetabular cup with an iliac stem in combination with a cranial strap" in the section ….

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA