Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Environ Health Sci Eng ; 20(1): 1-10, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35669804

RESUMO

Purpose: The aim of this study was to investigate the association between the psychological distress and sleep problems with environmental noise annoyance in adult population. Methods: This is a cross-sectional study on 822 adult population of Tehran City in 2016. Integrated cluster stratified random sampling and Kish grid method were used. Noise annoyance, the day-night average sound level (Ldn), nighttime average sound level (Lnight), and daytime average sound level (Lday) were selected as noise exposure indicators. The prevalence of psychological distress and sleep problems were assessed using the Kessler Psychological Distress Scale (K10) and the PSQI questionnaire, respectively. Multiple logistic regression analysis was applied for data analysis. Results: Among the participants 46.03%% were exposed to a sound level higher than the daytime standard level (55 dB) and 84.6% were exposed to a level higher than the nighttime standard limit (45 dBA). According to the results, 49% of the subjects had poor sleep quality and 66% were highly sensitive to noise. In addition, 17.73% had a high risk of mental disorders and 16.48% were found to have a mild risk of mental disorders. There was found a statistically significant association between psychological distress and the noise annoyance at home (OR = 1.3 CI 95% (1.17-1.44)) and at work environment (OR = 1.18 CI 95% (1.08-1.28)). Conclusion: The findings indicated that the study population was highly sensitive to noise. In addition, the relatively high percentage of people who exposed to non-standard levels of sound indicates that this exposure has the potential to cause physical and mental consequences among them.

2.
Environ Pollut ; 301: 119042, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35202767

RESUMO

Although road traffic noise is the most important source of environmental noise emission in large cities, little is known about health burden. The present study was conducted to estimate the burden of diseases attributed to traffic noise in the metropolis of Tehran in 2017. Using noise maps provided by the municipality of Tehran, we calculated population exposure distribution in term of Ldn and Lnight and the number of DALYs lost due to ischemic heart disease, hypertension, high sleep disturbance, annoyance and stroke endpoints based on the World Health Organization Environmental Noise Guidelines for the European Region. We applied published dose-response functions to estimate the traffic noise burden for high sleep disturbance and annoyance. We estimated 61,284 DALYs or 697 DALYs per 100,000 population attributed to traffic noise in Tehran for the reference year 2017. Highly sleep disturbance with a share of 58.74% of the DALYs was recognized as the most important contributor of disease burden, and noise annoyance with a share of 23.12% was ranked next. Ischemic heart disease (11.71%), stroke (5.12%), and hypertension (1.31%) were ranked third to fourth, respectively, in terms of the burden of disease caused by environmental noise. A considerable fraction of the population of Tehran lives in areas with an environmental noise higher than the standard level. The findings showed that traffic noise pollution is an important environmental risk factor in Tehran imposes the greatest burden on the community, mainly through highly sleep disturbance and noise annoyance endpoints.


Assuntos
Ruído dos Transportes , Transtornos do Sono-Vigília , Efeitos Psicossociais da Doença , Exposição Ambiental , Humanos , Irã (Geográfico)/epidemiologia , Ruído dos Transportes/efeitos adversos , Transtornos do Sono-Vigília/epidemiologia , Transtornos do Sono-Vigília/etiologia
3.
J Res Health Sci ; 14(1): 46-51, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24402850

RESUMO

BACKGROUND: Noise pollution is currently a major risk factor in industries in both developed and developing countries.The present study assessed noise pollution in the knitting industry in Iran in 2009 and presented a control method to reduce the rate of noise generation. METHODS: The overall noise level was estimated using the network environmental noise assessment method in Sina Poud textile mill in Hamadan. Then, frequency analysis was performed at indicator target stations in the linear network. Finally, a suitable absorbent was recommended for the ceilings, walls, and aerial panels at three phases according to the results found for the sound source and destination environment. RESULTS: The results showed that the highest sound pressure level was 98.5 dB and the lowest was 95.1 dB. The dominant frequency for the industry was 500 Hz. The highest and lowest sound suppression was achieved by intervention at 4000 Hz equivalent to 14.6 dB and 250 Hz in the textile industry. CONCLUSIONS: When noise control at the source is not available or insufficient because of the wide distribution of the acoustic field in the workplace, the best option is to increase the absorptive surface of the workplace using adsorbents such as polystyrene.


Assuntos
Ruído Ocupacional/prevenção & controle , Exposição Ocupacional/prevenção & controle , Indústria Têxtil/normas , Acústica , Humanos , Irã (Geográfico) , Local de Trabalho
4.
Health Phys ; 104(1): 87-94, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23192091

RESUMO

Extremely Low-Frequency (ELF) electric and magnetic fields belonging to the nonionizing electromagnetic radiation spectrum have a frequency of 50 - 60 Hz. All people are exposed to a complex set of electric and magnetic fields that spread throughout the environment. The current study was carried out to assess people's exposure to an ELF electric field in the Tehran metropolitan area in 2010. The measurement of the electronic fields was performed using an HI-3604 power frequency field strength measurement device. A total number of 2,753 measurements were performed. Afterward, the data obtained were transferred to the base map using Arc View Version 3.2 and Arc Map Version 9.3. Finally, an interpolation method was applied to expand the intensity of the electric field to the entire city. Based on the results obtained, the electric field was divided into three parts with various intensities including 0-5 V m, 5-15 V m, and >15 V m. It should be noted that the status of high voltage transmission lines, electric substations, and specific points including schools and hospitals were also marked on the map. Minimum and maximum electric field intensities were measured tantamount to 0.31 V m and 19.80 V m, respectively. In all measurements, the electric field was much less than the amount provided in the ICNIRP Guide. The results revealed that 141 hospitals and 6,905 schools are situated in an area with electric field intensity equal to 0-5 V m, while 15 hospitals and 95 schools are located in zones of 5-15 V m and more than 15 V m. Examining high voltage transmission lines and electric substations in Tehran and its suburbs suggested that the impact of the lines on the background electric field of the city was low. Accordingly, 0.97 km of Tehran located on the city border adjacent to the high voltage transmission lines have an electric field in the range of 5 to 15 V m. The noted range is much lower than the available standards. In summary, it can be concluded that the public is not exposed to a risky background electric field in metropolitan Tehran. The result of comparing sensitive recipients showed that the schools have a more desirable status than the hospitals. Nonetheless, epidemiologic studies can lead to more understanding of the impact on public health.


Assuntos
Campos Eletromagnéticos , Monitoramento Ambiental/métodos , Exposição Ambiental , Humanos , Irã (Geográfico) , Fatores de Tempo
5.
Environ Monit Assess ; 184(1): 397-404, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21442190

RESUMO

Nowadays, usage of compensatory models in land evaluation process and site selection is broadly observed. Meanwhile, methods such as analytical hierarchy process are used more than the others. Whether the usage of compensatory model methods in site selection studies is essentially correct or not is an issue that should be hesitated. In this model, inefficiency of a factor, to be offset by strength of others, means that in urban development site selection, if somewhere has unsuitable aspect but suitable slope, the aspect deficiency will be compensated by the slope. But quodlibet reflection is that in this model, sometimes, deficiency of proximity to fault can be compensated by other parameters strength. And finally, a place is diagnosed as a suitable area for urban development that is close to the fault. This research aims at examination of compensatory models application in urban development site selection of Taleghan Basin using analytical hierarchy process as one of the compensatory model methods. Among this the weaknesses and strengths of compensatory model were analyzed carefully. Results indicate that despite usefulness of this model in being fast, easy, and low expense, it has some weaknesses like very high sensitivity to decision maker's idea.


Assuntos
Monitoramento Ambiental , Modelos Teóricos , Reforma Urbana , Simulação por Computador , Tomada de Decisões
6.
Environ Monit Assess ; 184(3): 1221-30, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21494828

RESUMO

Regarding various types of pollutant, waste management requires high attention. Environmental site selection study, prior to landfill operation, and subsequently, monitoring and maintaining of the location, are of foremost points in landfill site selection process. By means of these studies, it is possible to control the undesirable impacts caused by landfills. Study ahead aims at examination of effectiveness of a new method called Monavari 95-2 in landfill site assessment. For this purpose, two landfills Rasht and Andisheh, which are, respectively, located on humid and arid areas, were selected as case studies. Then, the results obtained from both sites were compared with each other to find out the weaknesses and strengths of each site. Compared with others similar methods, much more criteria (53 parameters) can be considered within this method, so the results will be more calculable. According to this method, Rasht landfill (site H) is classified as unacceptable landfill site i.e. there is an urgent need for a new suitable site for landfill, while Andishe Landfill (site D) is ranked as acceptable landfill site but needs environmental management program to handle the existing weaknesses.


Assuntos
Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Eliminação de Resíduos , Cidades , Monitoramento Ambiental/normas , Poluição Ambiental/estatística & dados numéricos , Irã (Geográfico) , Chuva , Medição de Risco/métodos
7.
Environ Monit Assess ; 175(1-4): 651-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20571882

RESUMO

No doubt, operator is one of the main fundaments in wastewater treatment plants. By identifying the inadequacies, the operator could be considered as an important key in treatment plant. Several methods are used for wastewater treatment that requires spending a lot of cost. However, all investments of treatment facilities are usable when the expected efficiency of the treatment plant was obtained. Using experienced operator, this goal is more easily accessible. In this research, the wastewater of an urban community contaminated with moderated, diluted and highly concentrated pollution has been treated using surface and deep aeration treatment method. Sampling of these pilots was performed during winter 2008 to summer 2009. The results indicate that all analyzed parameters were eliminated using activated sludge and surface aeration methods. However, in activated sludge and deep aeration methods in combination with suitable function of operator, more pollutants could be eliminated. Hence, existence of operator in wastewater treatment plants is the basic principle to achieve considered efficiency. Wastewater treatment system is not intelligent itself and that is the operator who can organize even an inefficient system by its continuous presence. The converse of this fact is also real. Despite the various units and appropriate design of wastewater treatment plant, without an operator, the studied process cannot be expected highly efficient. In places frequently affected by the shock of organic and hydraulic loads, the compensator tank is important to offset the wastewater treatment process. Finally, in regard to microbial parameters, existence of disinfection unit is very useful.


Assuntos
Esgotos/microbiologia , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/metabolismo , Enterobacteriaceae/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA