1.
Pacing Clin Electrophysiol ; 47(3): 347-352, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38140909

RESUMO

BACKGROUND: Cryoballoon ablation for atrial fibrillation (AF) requires adequate contact between the pulmonary vein (PV) antrum and cryoballoon. The surge of intraballoon pressure during the initial phase of ablation may change the balloon's shape and compliance, resulting in balloon dislodgement and loss of PV occlusion. Without continuous monitoring, this phenomenon is often undetected but can be associated with incomplete PV isolation (PVI). METHODS: Primary cryoablation of AF was performed in 15 patients. PV occlusion status pre- and post-freezing were analyzed with intracardiac echocardiography (ICE) and dielectric imaging-based occlusion tool (DIOT) to calculate the incidence of expansion dislodgement of cryoballoon. RESULTS: A total of 105 cryoablation applications were performed on 57 veins, including three common ostiums of left pulmonary veins. In the evaluation of PV occlusion, both modalities reported consistent results in 86.7% of the assessments. Despite complete PV occlusion before ablation, peri-balloon leak after initiation of freezing was detected by ICE in 5/22 (22.7%) applications and by DIOT in 8/25 (32%) applications. CONCLUSION: Incidence of expansion dislodgement of the cryoballoon was detected in one-fourth to one-third of cryoablation applications depending on the imaging modality used, which was clinically frequent and significant.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Incidência , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/métodos
2.
Curr Opin Cardiol ; 36(1): 1-4, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33264170

RESUMO

PURPOSE OF REVIEW: For over a decade, vulnerabilities in the healthcare industry have been identified. Medical devices such as cardiovascular implantable electronic devices (CIEDs) are particularly concerning because of direct threats to patient safety and protected health information (PHI). Although these vulnerabilities have been identified and changes have been made, there is significant room for improvement. We identify changes and improvements to be made in the industry, by providers, and by patients. RECENT FINDINGS: Cybersecurity threats in cardiac implantable devices are legitimate concerns for patient safety and PHI. Changes to cybersecurity in these devices have been made, but are far from sufficient. SUMMARY: The number of CIEDs implanted worldwide are expected to increase over the next decade. As computer technology advances, cybersecurity threats will only continue to evolve and become more complex. The healthcare industry should seriously consider improvements to protect patients and providers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Segurança Computacional , Humanos , Segurança do Paciente
3.
Card Electrophysiol Clin ; 2(3): 443-457, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28770802

RESUMO

In this review, we examine the data evaluating the role of adjuvant therapy with antiarrthymic drugs (AADs) in chronic suppression of ventricular tachyarrhythmias in the patient with an ICD. It must be noted that all uses of AADs for this indication represent "off-label" prescription. No AAD is approved by the Food and Drug Administration (FDA) specifically as a therapy to reduce ICD shocks.

4.
Clin Exp Pharmacol Physiol ; 34(1-2): 77-80, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17201739

RESUMO

1. Alterations in myocardial energy metabolism accompany pressure overload-induced hypertrophy. We previously described a novel model of catecholamine-induced hypertrophy in which A/J mice exhibit more robust cardiac hypertrophy than B6 mice. Accordingly, we assessed the influence of mouse strain on the activities of key myocardial metabolic enzymes and whether there are strain-related metabolic adaptations to short-term, high-dose isoproterenol (ISO) administration. 2. Thirty-nine male mice (19 A/J mice, 20 B6 mice), aged 12-15 weeks, were randomly assigned to receive either ISO (100 mg/kg, s.c.) or vehicle (sterile water) daily for 5 days. On Day 6, all hearts were excised, weighed, freeze clamped and assayed for pyruvate dehydrogenase (PDH), medium chain acyl-CoA dehydrogenase, carnitine palmitoyl transferase I and citrate synthase activities. Plasma fatty acids (FA) were also measured. 3. The ISO-treated A/J mice demonstrated greater percentage increases in gravimetric heart weight/bodyweight ratio than ISO-treated B6 mice (24 vs 3%, respectively; P < 0.001). All enzyme activities were significantly greater in vehicle-treated B6 mice than in A/J mice, illustrating a greater capacity for aerobic metabolism in B6 mice. Administration of ISO reduced PDHa (active form) activity in B6 mice by 47% (P < 0.001), with no significant change seen in A/J mice. Free FA levels were not significantly different between groups; thus, the differences in PDHa were not due to changes in FA. 4. The basal activity of myocardial metabolic enzymes is greater in B6 mice than in A/J mice and ISO alters myocardial PDH activity in a mouse strain-dependent manner. Compared with A/J mice, B6 mice demonstrate less ISO-induced cardiac hypertrophy, but greater activity of key enzymes regulating FA and carbohydrate oxidation, which may protect against the development of hypertrophy. The metabolic adaptations associated with ISO-induced hypertrophy differ from those reported with pressure overload hypertrophy.


Assuntos
Hipertrofia Ventricular Esquerda/metabolismo , Miocárdio/enzimologia , Acil-CoA Desidrogenase/metabolismo , Animais , Carnitina O-Palmitoiltransferase/metabolismo , Citrato (si)-Sintase/metabolismo , Hipertrofia Ventricular Esquerda/induzido quimicamente , Isoproterenol , Cetona Oxirredutases/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos , Especificidade da Espécie
5.
Am J Physiol Heart Circ Physiol ; 287(5): H2049-53, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15475530

RESUMO

The rat infarct model is widely used in heart failure research, but few echocardiographic indexes of left ventricular (LV) function are validated in this model. Accordingly, the objective of this study was to validate a 13-segment LV wall motion score index (WMSI) and the myocardial performance index (MPI) in infarcted rats. Twenty-nine male Wistar rats underwent left coronary artery ligation or sham operation and were evaluated with two-dimensional and Doppler flow echocardiography 8 wk later. After echocardiography, invasive indexes were obtained using a high-fidelity catheter. WMSI and MPI were correlated with the invasive and noninvasive measurements of LV function. WMSI and MPI significantly correlated directly with end-diastolic pressure (r=0.72 and 0.42 for WMSI and MPI, respectively) and the time constant of isovolumic relaxation (r=0.68 and 0.48) and inversely with peak rate of rise of LV pressure (+dP/dt; r=-0.68 and -0.50), peak rate of decline in LV pressure (r=-0.57 and -0.44), LV developed pressure (r=-0.58 and -0.42), area fractional shortening (r=-0.85 and -0.53), and cardiac index (r=-0.74 and -0.74). Stepwise linear regression analyses revealed that LV end-diastolic pressure, +dP/dt, area fractional shortening, and cardiac index were independent determinants of WMSI (r=0.994) and that cardiac index and +dP/dt were independent determinants of MPI (r=0.781). We conclude that the 13-segment WMSI and MPI are reproducible and correlate strongly with established echocardiographic and invasive indexes of systolic and diastolic function. These findings support the use of WMSI and MPI as indexes of global LV function in the rat infarction model of heart failure.


Assuntos
Ecocardiografia/métodos , Infarto do Miocárdio/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Animais , Cateterismo Cardíaco , Ecocardiografia/normas , Hemodinâmica , Masculino , Variações Dependentes do Observador , Ratos , Ratos Endogâmicos WKY , Reprodutibilidade dos Testes