Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38693291

RESUMO

BACKGROUND: Early mobilization after tendon surgery is crucial to avoid commonly observed postoperative soft tissue adhesions. Recently, a new suture was introduced (DYNACORD; DC) with a salt-infused silicone core designed to minimize laxity and preserve consistent tissue approximation in order to avoid gap formation and allow early mobilization. AIMS: To compare the biomechanical competence of DC against a conventional high strength suture (FiberWire; FW) in a human cadaveric tendon transfer model with an early rehabilitation protocol. METHODS: Sixteen tendon transfers (flexor digitorum superficialis (FDS) IV to flexor pollicis longus (FPL)) were performed in 8 pairs human cadaveric forearms using either DC or FW. Markings were set 0.8 cm proximally and 0.7 cm distally to the level of the interweaving zone of the transfer. All specimens underwent repetitive thumb flexion against resistance in 9 intermittent series of 300 cycles each, simulating an aggressive postoperative rehabilitation protocol. After each series, the distance of the proximal marker to the interweaving zone (proximal), the length of the interweaving zone (intermediate) and the distance of the distal marker to the interweaving zone (distal) were measured. RESULTS: Pooled data over all nine series, normalized to the immediate postoperative status, demonstrated no significant differences between FW and DC (p ≥ 0.355) for the proximal and distal markers. However, at the intermediate zone, DC was associated with significant length shortening (p < 0.001) compared to FW without significant length changes (p = 0.351). Load to catastrophic failure demonstrated significant higher forces in FW (p = 0.011). Nevertheless, due to failure mainly proximal or distal of the transfer zone, these loads are not informative. CONCLUSION: From a biomechanical perspective, DC preserved tissue approximation and might be considered as a valid alternative to conventional high-strength sutures in tendon transfer surgery. DC might allow for a shorter interweaving zone and a more aggressive early postoperative rehabilitation program, possibly avoiding commonly observed postoperative soft tissue adhesions and stiffness.

2.
Foot Ankle Int ; : 10711007241241075, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38618682

RESUMO

BACKGROUND: Pressure distribution in the ankle joint is known to be dependent on various factors, including hindfoot alignment. We seek to evaluate how hindfoot alignment affects contact pressures in the ankle joint in the setting of supination external rotation (SER) type ankle fractures. METHODS: SER fractures were created in 10 human cadaver lower extremity specimens, simulating progressive stages of injury: without fracture (step 0), SER fracture and intact deltoid ligament (step 1), superficial deltoid ligament disruption (step 2), and deep deltoid ligament disruption (step 3). At each step, varus and valgus alignment was simulated by displacing the calcaneal tuberosity 7 mm medial or lateral. Each limb was axially loaded following each osteotomy at a static load of 350 N. The center of force (COF), contact area (CA), and peak contact pressure (PP) under load were measured, and radiographs of the ankle mortise were taken to analyze the medial clear space (MCS) and talar tilt (TT). RESULTS: The COF (5.3 mm, P = .030) and the CA (-188.4 mm2, P = .015) changed in step 3 in the valgus hindfoot alignment compared to baseline parameters, indicating the importance of deep deltoid ligament integrity in maintaining normal ankle joint contact stress in the valgus hindfoot. These changes were not seen in the setting of varus alignment (COF: 2.3 mm, P = .059; CA -121 mm2, P = .133). PP were found to not change significantly in either varus or valgus (varus: -4.9 N, P = .132; valgus: -4 N, P = .464).The MCS demonstrated widening in step 3 compared to step 2 (0.7 mm, P = .020) in both varus and valgus hindfoot. The TT increased significantly in step 3 in the valgus hindfoot (2.8 degrees, P = .020) compared to step 0. CONCLUSION: SER-IV fractures with valgus hindfoot alignment showed significant changes in pressure distribution and radiographic parameters when compared to SER-IV fractures with varus hindfoot alignment. CLINICAL RELEVANCE: Based on this cadaver modeling study, patients with SERIV fracture with varus hindfoot alignment and complete deltoid ligament lesion may not need fracture fixation, whereas those with valgus hindfoot alignment likely need fracture fixation.

3.
Bone Rep ; 21: 101752, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38590390

RESUMO

High-resolution peripheral quantitative computed tomography (HR-pQCT) based micro-finite element (µFE) analysis allows accurate prediction of stiffness and ultimate load of standardised (∼1 cm) distal radius and tibia sections. An alternative homogenized finite element method (hFE) was recently validated to compute the ultimate load of larger (∼2 cm) distal radius sections that include Colles' fracture sites. Since the mechanical integrity of the weight-bearing distal tibia is gaining clinical interest, it has been shown that the same properties can be used to predict the strength of both distal segments of the radius and the tibia. Despite the capacity of hFE to predict structural properties of distal segments of the radius and the tibia, the limitations of such homogenization scheme remain unclear. Therefore, the objective of this study is to build a complete mechanical data set of the compressive behavior of distal segments of the tibia and to compare quantitatively the structural properties with the hFE predictions. As a further aim, it is intended to verify whether hFE is also able to capture the post-yield strain localisation or fracture zones in such a bone section, despite the absence of strain softening in the constitutive model. Twenty-five fresh-frozen distal parts of tibias of human donors were used in this study. Sections were cut corresponding to an in-house triple-stack protocol HR-pQCT scan, lapped, and scanned using micro computed tomography (µCT). The sections were tested in compression until failure, unloaded and scanned again in µCT. Volumetric bone mineral density (vBMD) and bone mineral content (BMC) were correlated to compression test results. hFE analysis was performed in order to compare computational predictions (stiffness, yield load and plastic deformation field pattern) with the compressive experiment. Namely, strain localization was assessed based on digital volume correlation (DVC) results and qualitatively compared to hFE predictions by comparing mid-slices patterns. Bone mineral content (BMC) showed a good correlation with stiffness (R2 = 0.92) and yield (R2 = 0.88). Structural parameters also showed good agreement between the experiment and hFE for both stiffness (R2 = 0.96, slope = 1.05 with 95 % CI [0.97, 1.14]) and yield (R2 = 0.95, slope = 1.04 [0.94, 1.13]). The qualitative comparison between hFE and DVC strain localization patterns allowed the classification of the samples into 3 categories: bad (15 sections), semi (8), and good agreement (2). The good correlations between BMC or hFE and experiment for structural parameters were similar to those obtained previously for the distal part of the radius. The failure zones determined by hFE corresponded to registration only in 8 % of the cases. We attribute these discrepancies to local elastic/plastic buckling effects that are not captured by the continuum-based FE approach exempt from strain softening. A way to improve strain localization hFE prediction would be to use longer distal segments with intact cortical shells, as done for the radius. To conclude, the used hFE scheme captures the elastic and yield response of the tibia sections reliably but not the subsequent failure process.

4.
Arch Orthop Trauma Surg ; 144(5): 2131-2140, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520547

RESUMO

INTRODUCTION: Treatment of both simple and complex patella fractures is a challenging clinical problem. Although tension band wiring has been the standard of care, it can be associated with high complication rates. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. MATERIALS AND METHODS: Sixteen pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior (central distal) fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full extension. Interfragmentary movements were captured via motion tracking. RESULTS: For both fracture types, the articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p ≤ 0.01. CONCLUSIONS: From a biomechanical perspective, lateral rim variable angle locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas , Patela , Humanos , Patela/lesões , Patela/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Cadáver , Idoso , Masculino , Feminino , Fratura da Patela
5.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 864-871, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38454816

RESUMO

PURPOSE: To investigate the forces on a medial collateral ligament (MCL) reconstruction (MCLR) relative to the valgus alignment of the knee. METHODS: Eight fresh-frozen human cadaveric knees were subjected to dynamic valgus loading at 400 N using a custom-made kinematics rig. After resection of the superficial medial collateral ligament, a single-bundle MCLR with a hamstring tendon autograft was performed. A medial opening wedge distal femoral osteotomy was performed and fixed with an external fixator to gradually adjust the alignment in 5° increments from 0° to 10° valgus. For each degree of valgus deformity, the resulting forces acting on the MCLR were measured through a force sensor and captured in 15° increments from 0° to 60° of knee flexion. RESULTS: Irrespective of the degree of knee flexion, increasing valgus malalignment resulted in significantly increased forces acting on the MCLR compared to neutral alignment (p < 0.05). Dynamic loading at 5° valgus resulted in increased forces on the MCLR at all flexion angles ranging between 16.2 N and 18.5 N (p < 0.05 from 0° to 30°; p < 0.01 from 45° to 60°). A 10° valgus malalignment further increased the forces on the MCLR at all flexion angles ranging between 29.4 N and 40.0 N (p < 0.01 from 0° to 45°, p < 0.05 at 60°). CONCLUSION: Valgus malalignment of the knee caused increased forces acting on the reconstructed MCL. In cases of chronic medial instabilities accompanied by a valgus deformity ≥ 5°, a realigning osteotomy should be considered concomitantly to the MCLR to protect the graft and potentially reduce graft failures. LEVEL OF EVIDENCE: Level III.


Assuntos
Ligamentos Colaterais , Tendões dos Músculos Isquiotibiais , Humanos , Cadáver , Articulação do Joelho/cirurgia , Fenômenos Biomecânicos , Ligamentos Colaterais/cirurgia
6.
J Bone Joint Surg Am ; 106(9): 809-816, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38377221

RESUMO

BACKGROUND: The current literature lacks recommendations regarding surgical approaches to best visualize and reduce Hoffa fractures. The aims of this study were to (1) define surgical corridors to the posterior portions of the lateral and medial femoral condyles and (2) compare the articular surface areas visible with different approaches. METHODS: Eight fresh-frozen human cadaveric knees (6 male and 2 female donors; mean age, 68.2 ± 10.2 years) underwent dissection simulating 6 surgical approaches to the distal femur. The visible articular surface areas for each approach were marked using an electrocautery device and subsequently analyzed using image-processing software. The labeled areas of each femoral condyle were statistically compared. RESULTS: At 30° of flexion, visualization of the posterior portions of the lateral and medial femoral condyles was not possible by lateral and medial parapatellar approaches, as only the anterior 29.4% ± 2.1% of the lateral femoral condyle and 25.6% ± 2.8% of the medial condyle were exposed. Visualization of the lateral femoral condyle was limited by the posterolateral ligamentous structures, hence a posterolateral approach only exposed its central (13.1% ± 1.3%) and posterior (12.4% ± 1.1%) portions. Posterolateral extension by an osteotomy of the lateral femoral epicondyle significantly improved the exposure to 53.4% ± 2.7% and, when combined with a Gerdy's tubercle osteotomy, to 70.9% ± 4.1% (p < 0.001). For the posteromedial approach, an arthrotomy between the anteromedial retinaculum and the superficial medial collateral ligament, and one between the posterior oblique ligament and the medial gastrocnemius tendon, allowed visualization of the central (13.5% ± 2.2%) and the posterior (14.6% ± 2.3%) portions of the medial femoral condyle, while a medial femoral epicondyle osteotomy significantly improved visualization to 66.1% ± 5.5% (p < 0.001). CONCLUSIONS: Visualization of the posterior portions of the femoral condyles is limited by the specific anatomy of each surgical corridor. Extension by osteotomy of the femoral epicondyles and Gerdy's tubercle significantly improved articular surface exposure of the femoral condyles. CLINICAL RELEVANCE: Knowledge of the surgical approach-specific visualization of the articular surface of the femoral condyles might be helpful to properly reduce small Hoffa fragments.


Assuntos
Cadáver , Fraturas do Fêmur , Humanos , Feminino , Masculino , Idoso , Fraturas do Fêmur/cirurgia , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Fêmur/cirurgia , Fêmur/anatomia & histologia , Idoso de 80 Anos ou mais , Dissecação/métodos
7.
J Shoulder Elbow Surg ; 33(2): 409-416, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37748530

RESUMO

BACKGROUND: Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and a less prominent and optimized plate-to-bone fit design. On the other hand, minifragment plates in dual plating mode have demonstrated promising clinical results. The aim of the current study was to compare the biomechanical competence of single superior plating using the new-generation plate vs. dual plating using low-profile minifragment plates. METHODS: Sixteen paired human cadaveric clavicles were pairwise assigned to 2 groups for instrumentation with either a superior 2.7-mm variable-angle locking compression plate (group 1), or with one 2.5-mm anterior combined with one 2.0-mm superior matrix mandible plate (group 2). An unstable clavicle shaft fracture (AO/OTA 15.2C) was simulated by means of a 5-mm osteotomy gap. Specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis, and monitored via motion tracking. RESULTS: Initial construct stiffness was significantly higher in group 2 (9.28 ± 4.40 N/mm) compared to group 1 (3.68 ± 1.08 N/mm), P = .003. The amplitudes of interfragmentary motions in terms of axial and shear displacement, fracture gap opening and torsion, over the course of 12,500 cycles were significantly higher in group 1 compared to group 2, P ≤ .038. Cycles to 2 mm shear displacement were significantly lower in group 1 (22,792 ± 4346) compared to group 2 (27,437 ± 1877), P = .047. CONCLUSION: From a biomechanical perspective, low-profile 2.5/2.0-mm dual plates could be considered as a useful alternative for diaphyseal clavicle fracture fixation, especially in less common unstable fracture configurations.


Assuntos
Clavícula , Fraturas Ósseas , Humanos , Clavícula/cirurgia , Fenômenos Biomecânicos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Placas Ósseas
8.
J Orthop Res ; 42(4): 886-893, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37975265

RESUMO

Dual plating of comminuted distal femoral fractures allows for early patient mobilization. An additional helically shaped medial plate avoids the medial vital structures of the thigh. The aim of this study is to investigate the biomechanical competence of an augmented lateral locking compression plate distal femur (LCP-DF) using an additional straight versus a helically shaped medial LCP of the same length. Ten pairs of human cadaveric femora were instrumented with a lateral anatomical 15-hole LCP-DF. Following, they were pairwise instrumented with either an additional medial straight 14-hole LCP (group 1) or a 90°-helical shape LCP (group 2). All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading until failure. Initial interfragmentary axial displacement and flexion under static compression were significantly smaller in group 1 (0.11 ± 0.12 mm and 0.21 ± 0.10°) versus group 2 (0.31 ± 0.14 mm and 0.68 ± 0.16°), p ≤ 0.007. Initial varus deformation under static compression remained not significantly different between group 1 (0.57 ± 0.23°) and group 2 (0.75 ± 0.34°), p = 0.085. Flexion movements during dynamic loading were significantly bigger in group 2 (2.51 ± 0.54°) versus group 1 (1.63 ± 1.28°), p = 0.015; however, no significant differences were observed in terms of varus, internal rotation, and axial and shear displacements between the groups, p ≥ 0.204. Cycles to failure and load at failure were higher in group 2 (25,172 ± 6376 and 3017 ± 638 N) compared to group 1 (22,277 ± 4576 and 2728 ± 458 N) with no significant differences between them, p = 0.195. From a biomechanical perspective, helical double plating may be considered a useful alternative to straight double plating, demonstrating ameliorated damping capacities during flexion deformation and safer application as the medial neurovascular structures of the thigh are avoided.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Humanos , Fenômenos Biomecânicos , Fêmur/cirurgia , Placas Ósseas , Extremidade Inferior
9.
Int Orthop ; 48(3): 643-649, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38015209

RESUMO

PURPOSE: The number of seven required throws per knot was previously reported as providing sufficient security against slippage. A novel high-strength suture featuring dynamic tightening may allow for throw number reduction without compromising stability. The aims of this study were to (1) investigate the influence of the throw number and the effect of different ambient conditions on the knot security of two different high-strength sutures, and (2) compare their biomechanical competence. METHODS: Two sutures (FiberWire (FW) and DynaCord (DC)) were considered for preparing alternating surgical knots. The specimens were stratified for exposure to different media during biomechanical testing-namely air (dry), saline solution (wet), and fat (fatty-wet). A monotonic tensile ramp loading to failure was applied in each test run. For each suture and ambient condition, seven specimens with three to seven throws each were tested (n = 7), evaluating their slippage and ultimate force to failure. The minimum number of throws preventing suture unraveling was determined for each suture type and condition. RESULTS: For each suture type and condition, failure occurred via rupture in all specimens for the following minimum number of throws: FW-dry-7, wet-7, fatty-wet-7; DC-dry-6, wet-4, fatty-wet-5. When applying seven throws, FW demonstrated significantly larger slippage (6.5 ± 2.2 mm) versus DC (3.5 ± 0.4 mm) in wet (p = 0.004) but not in dry and fatty-wet conditions (p ≥ 0.313). CONCLUSIONS: The lower number of throws providing knot security of DC versus FW in the more realistic wet and fatty-wet conditions indicates that the novel DC suture may allow to decrease the foreign body volume and save surgical time without compromising the biomechanical competence.


Assuntos
Técnicas de Sutura , Suturas , Humanos , Teste de Materiais , Resistência à Tração , Ruptura , Técnicas de Sutura/efeitos adversos
10.
Bioengineering (Basel) ; 10(12)2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38135988

RESUMO

OBJECTIVES: As currently there is no existing biomechanical work on the topic of interest, the aim of the current study was to investigate the effect of cerclage banding distally to an intraoperatively occurring proximal periprosthetic femoral clamshell fracture versus a non-fractured femur after total hip arthroplasty. METHODS: A diaphyseal anchoring stem was implanted in twenty paired human cadaveric femora, assigned to a treatment and a control group. In the treatment group, each specimen was fitted with a cerclage band placed 3 mm distally to a clamshell fracture, created with an extent of 40% of the anchoring length of the stem. The resulting fragment was not treated further. The contralateral specimens were left with the stems without further fracture creation or treatment. All constructs were tested under progressively increasing cyclic axial loading until failure. Relative bone-implant movements were monitored by motion tracking. RESULTS: Number of cycles and the corresponding load at stem loosening, defined as 1 mm displacement of the stem along the shaft axis, were 31,417 ± 8870 and 3641.7 ± 887 N in the control group, and 26,944 ± 11,706 and 3194.4 ± 1170.6 N in the treatment group, respectively, with no significant differences between them, p = 0.106. CONCLUSION: From a biomechanical perspective, cerclage banding distally to an intraoperative clamshell fracture with an extent of 40% of the anchoring length of the stem demonstrated comparable resistance against hip stem loosening versus a non-fractured femur. It may therefore represent a valid treatment option to restore the full axial stability of a diaphyseal anchoring stem. In addition, it may be considered to keep the medial wall fragment unfixed, thus saving operative time and minimizing associated risks.

11.
Medicina (Kaunas) ; 59(11)2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38004092

RESUMO

Background and Objectives: The surgical treatment of proximal humeral shaft fractures usually considers application of either long straight plates or intramedullary nails. By being able to spare the rotator cuff and avoid the radial nerve distally, the implementation of helical plates might overcome the downsides of common fixation methods. The aims of the current study were (1) to explore the biomechanical competence of different plate designs and (2) to compare their performance versus the alternative treatment option of using intramedullary nails. Materials and Methods: Twenty-four artificial humeri were assigned to the following four groups for simulation of an unstable proximal humeral shaft fracture and instrumentation: Group 1 (Straight-PHILOS), Group 2 (MULTILOC-Nail), Group 3 (45°-Helical-PHILOS), and Group 4 (90°-Helical-PHILOS). All specimens underwent non-destructive, quasi-static biomechanical testing under loading in axial compression, torsion in internal/external rotation, and pure bending in four directions, accompanied by motion tracking. Results: Axial stiffness/displacement in Group 2 was significantly higher/smaller than in all other groups (p ≤ 0.010). Torsional displacement in Group 2 was significantly bigger than in all other groups (p ≤ 0.017). Significantly smaller coronal plane displacement was identified in Group 2 versus all other groups (p < 0.001) and in Group 4 versus Group 1 (p = 0.022). Significantly bigger sagittal plane displacement was detected in Group 4 versus all other groups (p ≤ 0.024) and in Group 1 versus Group 2 (p < 0.001). Conclusions: Intramedullary nails demonstrated higher axial stiffness and smaller axial interfragmentary movements compared with all investigated plate designs. However, they were associated with bigger torsional movements at the fracture site. Although 90°-helical plates revealed bigger interfragmentary movements in the sagittal plane, they demonstrated improved resistance against displacements in the coronal plane when compared with straight lateral plates. In addition, 45°-helical plates manifested similar biomechanical competence to straight plates and may be considered a valid alternative to the latter from a biomechanical standpoint.


Assuntos
Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/métodos , Pinos Ortopédicos , Fenômenos Biomecânicos , Fixação Interna de Fraturas , Úmero , Placas Ósseas
12.
Clin Biomech (Bristol, Avon) ; 110: 106119, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37832469

RESUMO

BACKGROUND: Distal femoral fractures are commonly treated with lateral straight plates. However, the lateral approach may not always be desirable, and 180°-helical plates may be an alternative. AIM: To investigate the biomechanical competence of 180°-helical plating versus standard straight lateral plating of unstable fractures at the distal femur. METHODS: Twelve left artificial femora were instrumented with a 15-hole Locking Compression Plate-Distal Femur, using either 180°-helical plates (group 1) or conventional straight lateral plates (group 2). An unstable distal femoral fracture AO/OTA 33-A3.3 was simulated. All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading in internal rotation until failure. FINDINGS: Initial axial stiffness (N/mm) was significantly higher in group 1 (185.6 ± 50.1) compared to group 2 (56.0 ± 14.4), p < 0.001. Group 1 demonstrated significantly higher initial interfragmentary flexion (°) and significantly lower initial varus/valgus deformation (°) under 500 N static axial compression versus group 2 (2.76 ± 1.02 versus 0.87 ± 0.77 and 4.08 ± 1.49 versus 6.60 ± 0.47), p ≤ 0.005. Shear displacement (mm) under 6 Nm static torsion was significantly higher in group 1 versus group 2 in both internal (1.23 ± 0.28 versus 0.40 ± 0.42) and external (1.21 ± 0.40 versus 0.57 ± 0.33) rotation, p ≤ 0.013. Cycles to failure and failure load (N) (clinical/catastrophic) were significantly higher in group 1 (12,484 ± 2116/13,752 ± 1518 and 1748.4 ± 211.6/1875.2 ± 151.8) compared to group 2 (7853 ± 1262/9727 ± 836 and 1285.3 ± 126.2/1472.7 ± 83.6), p ≤ 0.001. INTERPRETATION: Although 180°-helical plating using a pre-contoured standard straight lateral plate was associated with higher shear and flexion movements, it demonstrated improved initial axial stability and resistance against varus/valgus deformation compared to straight lateral plating. Moreover, the helical plates were associated with significantly higher endurance to failure. From a biomechanical perspective, 180°-helical plating may be considered as a valuable alternative to standard straight lateral plating of unstable distal femoral fractures.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Humanos , Fraturas do Fêmur/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas , Placas Ósseas
13.
Clin Biomech (Bristol, Avon) ; 109: 106095, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37757678

RESUMO

BACKROUND: The beneficial effects of unrestricted postoperative full weight bearing for elderly patients suffering hip fractures have been demonstrated. However, there is still existing disagreement regarding acetabular fractures.The aim of this biomechanical study was to evaluate the initial load bearing capabilities of different fixation constructs of anterior column fractures (ACFs) in osteoporotic bone. METHODS: Artificial pelvises with ACFs were assigned to three groups (n = 8) and fixed with either a 7.3 mm partially threaded antegrade cannulated screw (group AASS), an anteriorly placed 3.5 mm plate (group AAPF), or a press-fit acetabular cup with screw augmentation (group AACF). All specimens underwent ramped loading from 20 N preload to 200 N at a rate of 18 N/s, followed by progressively increasing cyclic testing at 2 Hz until failure performed at a rate of 0.05 N/cycle. Relative displacements of the bone fragments were monitored by motion tracking. FINDINGS: Initial stiffness (N/mm) was 118.5 ± 34.3 in group AASS, 100.4 ± 57.5 in group AAPF, and 92.9 ± 44.0 in group AACF, with no significant differences between the groups, p = 0.544. Cycles to failure were significantly higher in groups AACF (8364 ± 2243) and AAPF (7827 ± 2881) compared to group AASS (4440 ± 2063), p ≤ 0.041. INTERPRETATION: From a biomechanical perspective, the minimally invasive cup fixation with screw augmentation demonstrated comparable stability to plate osteosynthesis of ACFs in osteoporotic bone. The results of the present study do not allow to conclusively answer whether immediate full weight bearing following cup fixation shall be allowed. Given its similar performance to plate osteosynthesis, this remains rather an utopic wish and a more conservative approach deems more reasonable.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Osteoporose , Fraturas da Coluna Vertebral , Humanos , Idoso , Acetábulo/cirurgia , Estudos de Viabilidade , Fenômenos Biomecânicos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Parafusos Ósseos , Placas Ósseas
14.
Medicina (Kaunas) ; 59(9)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37763723

RESUMO

Background and Objectives: Unstable proximal humerus fractures (PHFs) with metaphyseal defects-weakening the osteosynthesis construct-are challenging to treat. A new augmentation technique of plated complex PHFs with metaphyseal defects was recently introduced in the clinical practice. This biomechanical study aimed to analyze the stability of plated unstable PHFs augmented via implementation of this technique versus no augmentation. Materials and Methods: Three-part AO/OTA 11-B1.1 unstable PHFs with metaphyseal defects were created in sixteen paired human cadaveric humeri (average donor age 76 years, range 66-92 years), pairwise assigned to two groups for locked plate fixation with identical implant configuration. In one of the groups, six-milliliter polymethylmethacrylate bone cement with medium viscosity (seven minutes after mixing) was placed manually through the lateral window in the defect of the humerus head after its anatomical reduction to the shaft and prior to the anatomical reduction of the greater tuberosity fragment. All specimens were tested biomechanically in a 25° adduction, applying progressively increasing cyclic loading at 2 Hz until failure. Interfragmentary movements were monitored by motion tracking and X-ray imaging. Results: Initial stiffness was not significantly different between the groups, p = 0.467. Varus deformation of the humerus head fragment, fracture displacement at the medial humerus head aspect, and proximal screw migration and cut-out were significantly smaller in the augmented group after 2000, 4000, 6000, 8000 and 10,000 cycles, p ≤ 0.019. Cycles to 5° varus deformation of the humerus head fragment-set as a clinically relevant failure criterion-and failure load were significantly higher in the augmented group, p = 0.018. Conclusions: From a biomechanical standpoint, augmentation with polymethylmethacrylate bone cement placed in the metaphyseal humerus head defect of plated unstable PHFs considerably enhances fixation stability and can reduce the risk of postoperative complications.

15.
Eur J Trauma Emerg Surg ; 49(6): 2569-2578, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37555991

RESUMO

BACKGROUND/PURPOSE: The surgical fixation of a symphyseal diastasis in partially or fully unstable pelvic ring injuries is an important element when stabilizing the anterior pelvic ring. Currently, open reduction and internal fixation (ORIF) by means of plating represents the gold standard treatment. Advances in percutaneous fixation techniques have shown improvements in blood loss, surgery time, and scar length. Therefore, this approach should also be adopted for treatment of symphyseal injuries. The technique could be important since failure rates, following ORIF at the symphysis, remain unacceptably high. The aim of this biomechanical study was to assess a semi-rigid fixation technique for treatment of such anterior pelvic ring injuries versus current gold standards of plate osteosynthesis. METHODS: An anterior pelvic ring injury type III APC according to the Young and Burgess classification was simulated in eighteen composite pelvises, assigned to three groups (n = 6) for fixation with either a single plate, two orthogonally positioned plates, or the semi-rigid technique using an endobutton suture implant. Biomechanical testing was performed in a simulated upright standing position under progressively increasing cyclic loading at 2 Hz until failure or over 150,000 cycles. Relative movements between the bone segments were captured by motion tracking. RESULTS: Initial quasi-static and dynamic stiffness, as well as dynamic stiffness after 100,000 cycles, was not significantly different among the fixation techniques (p ≥ 0.054).). The outcome measures for total displacement after 20,000, 40,000, 60,000, 80,000, and 100,000 cycles were associated with significantly higher values for the suture technique versus double plating (p = 0.025), without further significant differences among the techniques (p ≥ 0.349). Number of cycles to failure and load at failure were highest for double plating (150,000 ± 0/100.0 ± 0.0 N), followed by single plating (132,282 ± 20,465/91.1 ± 10.2 N), and the suture technique (116,088 ± 12,169/83.0 ± 6.1 N), with significantly lower values in the latter compared to the former (p = 0.002) and no further significant differences among the techniques (p ≥ 0.329). CONCLUSION: From a biomechanical perspective, the semi-rigid technique for fixation of unstable pubic symphysis injuries demonstrated promising results with moderate to inferior behaviour compared to standard plating techniques regarding stiffness, cycles to failure and load at failure. This knowledge could lay the foundation for realization of further studies with larger sample sizes, focusing on the stabilization of the anterior pelvic ring.


Assuntos
Fraturas Ósseas , Sínfise Pubiana , Humanos , Sínfise Pubiana/cirurgia , Sínfise Pubiana/lesões , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Pelve , Placas Ósseas
16.
Eur J Trauma Emerg Surg ; 49(6): 2553-2560, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37535095

RESUMO

INTRODUCTION: Pelvic fractures were often associated with high-energy trauma in young patients, but data show a significant increase in osteoporotic pelvic fractures in old age due to the progressive demographic change. There is an ongoing discussion about the best fixation techniques, which are ranging from lumbopelvic fixation to sacral bars or long transiliac-transsacral (TITS) screws. This study analyzes TITS screw osteosynthesis and sacroiliac screw osteosynthesis (SI), according to biomechanical criteria of fracture stability in osteoporotic human pelvic cadavers ex vivo. METHODS: Ten osteoporotic cadaveric pelvises were randomized into two groups of 5 pelvises each. An FFP-IIc fracture was initially placed unilaterally and subsequently surgically treated with a navigated SI screw or a TITS screw. The fractured side was loaded in a one-leg stance test setup until failure. Interfragmentary movements were assessed by means of optical motion tracking. RESULTS: No significant difference in axial stiffness were found between the SI and the TITS screws (21.2 ± 4.9 N and 18.4 ± 4.1 N, p = 0.662). However, there was a significantly higher stability of the fracture treatment in the cohort with TITS-screws for gap angle, flexion, vertical movement and overall stability. The most significant difference in the cycle interval was between 6.000 and 10.000 for the gap angle (1.62 ± 0.25° versus 4.60 ± 0.65°, p = 0.0001), for flexion (4.15 ± 0.39 mm versus 7.60 ± 0.81 mm, p = 0.0016), interval 11.000-15.000 for vertical shear movement (7.34 ± 0.51 mm versus 13.99 ± 0.97 mm, p < 0.0001) and total displacement (8.28 ± 0.66 mm versus 15.53 ± 1.07 mm, p < 0.0001) for the TITS and the SI screws. CONCLUSIONS: The results of this biomechanical study suggest a clear trend towards greater fracture stability of the TITS screw with significantly reduced interfragmentary movement. The application of a TITS screw for the treatment of the osteoporotic pelvic ring fracture may be prioritized to ensure the best possible patient care.


Assuntos
Fraturas Ósseas , Fraturas por Osteoporose , Ossos Pélvicos , Humanos , Fenômenos Biomecânicos , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fraturas por Osteoporose/cirurgia , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões , Pelve , Sacro/cirurgia , Sacro/lesões
17.
Medicina (Kaunas) ; 59(8)2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37629669

RESUMO

Background and purpose: Cannulated screws are standard implants for percutaneous fixa-tion of posterior pelvis ring injuries. The choice of whether to use these screws in combination with a washer is still undecided. The aim of this study was to evaluate the biomechanical competence of S1-S2 sacroiliac (SI) screw fixation with and without using a washer across three different screw designs. Material and Methods: Twenty-four composite pelvises were used and an SI joint injury type APC III according to the Young and Burgess classification was simulated. Fixation of the posterior pelvis ring was performed using either partially threaded short screws, fully threaded short screws, or fully threaded long transsacral screws. Biomechanical testing was performed under progressively increasing cyclic loading until failure, with monitoring of the intersegmental and bone-implant movements via motion tracking. Results: The number of cycles to failure and the corresponding load at failure (N) were significantly higher for the fully threaded short screws with a washer (3972 ± 600/398.6 ± 30.0) versus its counterpart without a washer (2993 ± 527/349.7 ± 26.4), p = 0.026. In contrast, these two parameters did not reveal any significant differences when comparing fixations with and without a washer using either partially threaded short of fully threaded long transsacral screws, p ≥ 0.359. Conclusions: From a biomechanical perspective, a washer could be optional when using partially threaded short or fully threaded long transsacral S1-S2 screws for treatment of posterior pelvis ring injuries in young trauma patients. Yet, the omission of the washer in fully threaded short screws could lead to a significant diminished biomechanical stability.


Assuntos
Técnicas Histológicas , Pelve , Humanos , Pacientes , Software , Parafusos Ósseos
18.
Medicina (Kaunas) ; 59(7)2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37512026

RESUMO

Background and Objectives: Minimally invasive surgeries for acetabulum fracture fixation are gaining popularity due to their known advantages versus open reduction and internal fixation. Antegrade or retrograde screw fixation along the long axis of the posterior column of the acetabulum is increasingly applied in surgical practice. While there is sufficient justification in the literature for the application of the anterior approach, there is a deficit of reports related to the posterior approach. The aim of this study was to evaluate the biomechanical competence of posterior column acetabulum fracture fixation through antegrade screw placement using either a standard cannulated screw or a cannulated compression headless screw (CCHS) via posterior approach. Materials and Methods: Eight composite pelvises were used, and a posterior column acetabulum fracture according to the Letournel Classification was simulated on both their left and right sides via an osteotomy. The sixteen hemi-pelvic specimens were assigned to two groups (n = 8) for either posterior column standard screw (group PCSS) or posterior column CCHS (group PCCH) fixation. Biomechanical testing was performed by applying steadily increased cyclic load until failure. Interfragmentary movements were investigated by means of motion tracking. Results: Initial stiffness demonstrated significantly higher values in PCCH (163.1 ± 14.9 N/mm) versus PCSS (133.1 ± 27.5 N/mm), p = 0.024. Similarly, cycles and load at failure were significantly higher in PCCH (7176.7 ± 2057.0 and 917.7 ± 205.7 N) versus PCSS (3661.8 ± 1664.5 and 566.2 ± 166.5 N), p = 0.002. Conclusion: From a biomechanical perspective, CCHS fixation demonstrates superior stability and could be a valuable alternative option to the standard cannulated screw fixation of posterior column acetabulum fractures, thus increasing the confidence in postoperative full weight bearing for both the patient and treating surgeon. Whether uneventful immediate postoperative full weight bearing can be achieved with CCHS fixation should primarily be investigated in further human cadaveric studies with a larger sample size.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Fraturas Ósseas/cirurgia , Acetábulo/cirurgia , Fixação Interna de Fraturas , Parafusos Ósseos , Fenômenos Biomecânicos
19.
Medicina (Kaunas) ; 59(7)2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37512121

RESUMO

Background and Objectives: The aim of this study was to investigate under dynamic loading the potential biomechanical benefit of simulated first tarsometatarsal (TMT-1) fusion with low-profile superelastic nitinol staples used as continuous compression implants (CCIs) in two different configurations in comparison to crossed screws and locked plating in a human anatomical model. Materials and Methods: Thirty-two paired human anatomical lower legs were randomized to four groups for TMT-1 treatment via: (1) crossed-screws fixation with two 4.0 mm fully threaded lag screws; (2) plate-and-screw fixation with a 4.0 mm standard fully threaded cortex screw, inserted axially in lag fashion, and a 6-hole TMT-1 Variable-Angle (VA) Fusion Plate 2.4/2.7; (3) CCI fixation with two two-leg staples placed orthogonally to each other; (4) CCI fixation with one two-leg staple and one four-leg staple placed orthogonally to each other. Each specimen was biomechanically tested simulating forefoot weightbearing on the toes and metatarsals. The testing was performed at 35-37 °C under progressively increasing cyclic axial loading until construct failure, accompanied by motion tracking capturing movements in the joints. Results: Combined adduction and dorsiflexion movement of the TMT-1 joint in unloaded foot condition was associated with no significant differences among all pairs of groups (p ≥ 0.128). In contrast, the amplitude of this movement between unloaded and loaded foot conditions within each cycle was significantly bigger for the two CCI fixation techniques compared to both crossed-screws and plate-and-screw techniques (p ≤ 0.041). No significant differences were detected between the two CCI fixation techniques, as well as between the crossed-screws and plate-and-screw techniques (p ≥ 0.493) for this parameter of interest. Furthermore, displacements at the dorsal and plantar aspects of the TMT-1 joint in unloaded foot condition, together with their amplitudes, did not differ significantly among all pairs of groups (p ≥ 0.224). Conclusions: The low-profile superelastic nitinol staples demonstrate comparable biomechanical performance to established crossed-screws and plate-and-screw techniques applied for fusion of the first tarsometatarsal joint.


Assuntos
, Ossos do Metatarso , Humanos , Ligas , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Ossos do Metatarso/cirurgia
20.
J Endocrinol ; 259(1)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439399

RESUMO

Fibroblast growth factor 23 (FGF23) is a phosphaturic hormone. X-linked hypophosphatemia (XLH) is the most prevalent inherited phosphate wasting disorder due to mutations in the PHEX gene, which cause elevated circulating FGF23 levels. Clinically, it is characterized by growth impairment and defective mineralization of bones and teeth. Treatment of XLH is challenging. Since 2018, neutralizing antibodies against FGF23 have dramatically improved the therapy of XLH patients, although not all patients fully respond to the treatment, and it is very costly. C-terminal fragments of FGF23 have recently emerged as blockers of intact FGF23 signaling. Here, we analyzed the effect on growth and bone of a short 26 residues long C-terminal FGF23 (cFGF23) fragment and two N-acetylated and C-amidated cFGF23 peptides using young XLH mice (Phex C733RMhda mice). Although no major changes in blood parameters were observed after 7 days of treatment with these peptides, bone length and growth plate structure improved. The modified peptides accelerated the growth rate probably by improving growth plate structure and dynamics. The processes of chondrocyte proliferation, death, hypertrophy, and the cartilaginous composition in the growth plate were partially improved in young treated XLH mice. In conclusion, these findings contribute to understand the role of FGF23 signaling in growth plate metabolism and show that this may occur despite continuous hypophosphatemia.


Assuntos
Raquitismo Hipofosfatêmico Familiar , Lâmina de Crescimento , Animais , Camundongos , Osso e Ossos/metabolismo , Raquitismo Hipofosfatêmico Familiar/genética , Raquitismo Hipofosfatêmico Familiar/metabolismo , Fatores de Crescimento de Fibroblastos/metabolismo , Lâmina de Crescimento/metabolismo , Fosfatos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA