1.
Radiol Med ; 129(2): 268-279, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38017228

RESUMO

OBJECTIVES: To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta. MATERIALS AND METHODS: Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels. Image quality was assessed independently by two radiologists on predefined aortic levels, including myocardium, proximal aortic branches, pulmonary veins and arteries, and the inferior (IVC) and superior vena cava (SVC). Image quality was assessed on a 5-point Likert scale. RESULTS: All datasets showed diagnostic image quality. Visual grading was similar for MRA and CTA regarding overall image quality (0.71), systemic arterial image quality (p = 0.07-0.91) and pulmonary artery image quality (p = 0.05). Both readers favored MRA for SVC and IVC, while CTA was preferred for pulmonary veins (all p < 0.05). No significant difference was observed in aortic diameters or cross-sectional areas between native MRA and contrast-enhanced CTA (p = 0.08-0.94). CONCLUSION: The proposed non-contrast MRA enables robust imaging of the aorta, its proximal branches and the pulmonary arteries and great veins with image quality and aortic diameters and cross-sectional areas comparable to that of CTA. Moreover, this technique represents a suitable free-breathing alternative, without the use of contrast agents or ionizing radiation. Therefore, it is especially suitable for patients requiring repetitive imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Angiografia por Ressonância Magnética/métodos , Veia Cava Superior/diagnóstico por imagem , Artéria Pulmonar
2.
Diagnostics (Basel) ; 13(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37510147

RESUMO

(1) Purpose: to compare right ventricular (RV) functional parameters in children with surgically repaired congenital heart disease (CHD) using single/double breath hold (BH) and free-breathing (FB) real-time compressed sensing (CS) cine cardiac magnetic resonance (cMRI) with standard retrospective segmented multi breath hold (RMB) cine cMRI. (2) Methods: Twenty patients with CHD underwent BH and FB, as well as RMB cine cMRI, at 3T to obtain a stack of continuous axial images of the RV. Two radiologists independently performed qualitative analysis of the image quality (rated on a 5-point scale; 1 = non-diagnostic to 5 = excellent) and quantitative analysis of the RV volume measurements. (3) Results: The best image quality was provided by RMB (4.5; range 2-5) compared to BH (3.9; range 3-5; p = 0.04) and FB (3.6; range 3-5; p < 0.01). The RV functional parameters were comparable among BH, FB, and RMB with a difference of less than 5%. The scan times for BH (44 ± 38 s, p < 0.01) and FB (24 ± 7 s, p < 0.01) were significantly reduced compared to for RMB (261 ± 68 s). (4) Conclusions: CS-FB and CS-BH real-time cine cMRI in children with CHD provides diagnostic image quality with excellent accuracy for measuring RV function with a significantly reduced scan time compared to RMB.

3.
Eur Radiol ; 32(7): 4340-4351, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35184220

RESUMO

OBJECTIVES: To investigate the efficacy of an in-line non-rigid motion-compensated reconstruction (NRC) in an image-navigated high-resolution three-dimensional late gadolinium enhancement (LGE) sequence with Dixon water-fat separation, in a clinical setting. METHODS: Forty-seven consecutive patients were enrolled prospectively and examined with 1.5 T MRI. NRC reconstructions were compared to translational motion-compensated reconstructions (TC) of the same datasets in overall and different sub-category image quality scores, diagnostic confidence, contrast ratios, LGE pattern, and semiautomatic LGE quantification. RESULTS: NRC outperformed TC in all image quality scores (p < 0.001 to 0.016; e.g., overall image quality 5/5 points vs. 4/5). Overall image quality was downgraded in only 23% of NRC datasets vs. 53% of TC datasets due to residual respiratory motion. In both reconstructions, LGE was rated as ischemic in 11 patients and non-ischemic in 10 patients, while it was absent in 26 patients. NRC delivered significantly higher LGE-to-myocardium and blood-to-myocardium contrast ratios (median 6.33 vs. 5.96, p < 0.001 and 4.88 vs. 4.66, p < 0.001, respectively). Automatically detected LGE mass was significantly lower in the NRC reconstruction (p < 0.001). Diagnostic confidence was identical in all cases, with high confidence in 89% and probable in 11% datasets for both reconstructions. No case was rated as inconclusive. CONCLUSIONS: The in-line implementation of a non-rigid motion-compensated reconstruction framework improved image quality in image-navigated free-breathing, isotropic high-resolution 3D LGE imaging with undersampled spiral-like Cartesian sampling and Dixon water-fat separation compared to translational motion correction of the same datasets. The sharper depictions of LGE may lead to more accurate measures of LGE mass. KEY POINTS: • 3D LGE imaging provides high-resolution detection of myocardial scarring. • Non-rigid motion correction provides better image quality in cardiac MRI. • Non-rigid motion correction may lead to more accurate measures of LGE mass.


Assuntos
Meios de Contraste , Gadolínio , Meios de Contraste/farmacologia , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Água
4.
Z Orthop Unfall ; 160(2): 183-189, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33233012

RESUMO

BACKGROUND: This study sought to retrospectively evaluate the clinical and magnetic resonance imaging (MRI) outcomes of u-HA/PLLA pin (u-HA/PLLA: hydroxyapatite/poly-L-lactic acid) pin fixation of unstable osteochondritis dissecans (OCD) lesions of the knee. METHODS: Seven adolescent patients (four females and three males) with arthroscopically unstable OCD lesions of the knee were included. The mean age at diagnosis was 13.1 years. Clinical results were evaluated preoperatively and during follow-up using the Ogilvie-Harris score (0 - 15 points). MRI scans were performed preoperatively and during follow-up, with results evaluated using the Dipaola classification (grades 1 - 4). Mean follow-up time was 29 months. RESULTS: The median Ogilvie-Harris score improved from 13 points (range: 10 - 14 points) to 15 points (range: 13 - 15 points). Separately, the median Dipaola score improved from 3 points (range: 2 - 4 points) to 1 point (range: 1 - 4 points). No complications such as infection, synovitis, or intra-articular adhesion were observed. CONCLUSIONS: Initial experiences using bioabsorbable u-HA/PLLA pins for the refixation of unstable OCD lesions in adolescents in the knee are promising, and MRI provides excellent monitoring of healing.


Assuntos
Osteocondrite Dissecante , Implantes Absorvíveis , Adolescente , Durapatita , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Osteocondrite Dissecante/diagnóstico por imagem , Osteocondrite Dissecante/cirurgia , Poliésteres , Estudos Retrospectivos
5.
Eur Radiol ; 31(6): 3951-3961, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33263160

RESUMO

OBJECTIVES: To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. MATERIAL AND METHODS: Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and examined with 1.5 T MRI. Overall subjective image quality, LGE pattern and extent, diagnostic confidence for detection of LGE, and scan time were evaluated and compared to standard 2D LGE imaging. Robustness of Dixon fat suppression was evaluated for 3D Dixon LGE imaging. For statistical analysis, the non-parametric Wilcoxon rank sum test was performed. RESULTS: LGE was rated as ischemic in 9 patients and non-ischemic in 11 patients while it was absent in 20 patients. Image quality and diagnostic confidence were comparable between both techniques (p = 0.67 and p = 0.66, respectively). LGE extent with respect to segmental or transmural myocardial enhancement was identical between 2D and 3D (water-only and in-phase). LGE size was comparable (3D 8.4 ± 7.2 g, 2D 8.7 ± 7.3 g, p = 0.19). Good or excellent fat suppression was achieved in 93% of the 3D LGE datasets. In 6 patients with pericarditis, the 3D sequence with Dixon fat suppression allowed for a better detection of pericardial LGE. Scan duration was significantly longer for 3D imaging (2D median 9:32 min vs. 3D median 10:46 min, p = 0.001). CONCLUSION: The 3D LGE sequence provides comparable LGE detection compared to 2D imaging and seems to be superior in evaluating the extent of pericardial involvement in patients suspected with pericarditis due to the robust Dixon fat suppression. KEY POINTS: • Three-dimensional LGE imaging provides high-resolution detection of myocardial scarring. • Robust Dixon water-fat separation aids in the assessment of pericardial disease. • The 2D image navigator technique enables 100% respiratory scan efficacy and permits predictable scan times.


Assuntos
Gadolínio , Imageamento Tridimensional , Meios de Contraste , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética , Água
6.
Eur Radiol ; 27(3): 946-955, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27251180

RESUMO

OBJECTIVE: The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on final ADC values. METHODS: Sixty-five lesions scanned with a standardized whole-body DWI-protocol at 3 T served as input data (EPI-DWI, b-values: 50, 400 and 800 s/mm2). Using exactly the same ROI coordinates, four different PPM (ADC_1-ADC_4) were executed to calculate corresponding ADC values, given as [10-3 mm2/s] of each lesion. Statistical analysis was performed to intra-individually compare ADC values stratified by PPM (Wilcoxon signed-rank tests: α = 1 %; descriptive statistics; relative difference/∆; coefficient of variation/CV). RESULTS: Stratified by PPM, mean ADCs ranged from 1.136-1.206 *10-3 mm2/s (∆ = 7.0 %). Variances between PPM were pronounced in the upper range of ADC values (maximum: 2.540-2.763 10-3 mm2/s, ∆ = 8 %). Pairwise comparisons identified significant differences between all PPM (P ≤ 0.003; mean CV = 7.2 %) and reached 0.137 *10-3 mm2/s within the 25th-75th percentile. CONCLUSION: Altering the PPM had a significant impact on the ADC value. This should be considered if ADC values from different post-processing methods are compared in patient studies. KEY POINTS: • Post-processing methods significantly influenced ADC values. • The mean coefficient of ADC variation due to PPM was 7.2 %. • To achieve reproducible ADC values, standardization of post-processing is recommended.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Imagem Corporal Total/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA