Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 4037, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740793

RESUMO

Laser-driven plasma accelerators provide tabletop sources of relativistic electron bunches and femtosecond x-ray pulses, but usually require petawatt-class solid-state-laser pulses of wavelength λL ~ 1 µm. Longer-λL lasers can potentially accelerate higher-quality bunches, since they require less power to drive larger wakes in less dense plasma. Here, we report on a self-injecting plasma accelerator driven by a long-wave-infrared laser: a chirped-pulse-amplified CO2 laser (λL ≈ 10 µm). Through optical scattering experiments, we observed wakes that 4-ps CO2 pulses with < 1/2 terawatt (TW) peak power drove in hydrogen plasma of electron density down to 4 × 1017 cm-3 (1/100 atmospheric density) via a self-modulation (SM) instability. Shorter, more powerful CO2 pulses drove wakes in plasma down to 3 × 1016 cm-3 that captured and accelerated plasma electrons to relativistic energy. Collimated quasi-monoenergetic features in the electron output marked the onset of a transition from SM to bubble-regime acceleration, portending future higher-quality accelerators driven by yet shorter, more powerful pulses.

2.
Rev Sci Instrum ; 93(4): 043102, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35489906

RESUMO

We report the development of a multipurpose differential x-ray calorimeter with a broad energy bandwidth. The absorber architecture is combined with a Bayesian unfolding algorithm to unfold high energy x-ray spectra generated in high-intensity laser-matter interactions. Particularly, we show how to extract absolute energy spectra and how our unfolding algorithm can reconstruct features not included in the initial guess. The performance of the calorimeter is evaluated via Monte Carlo generated data. The method accuracy to reconstruct electron temperatures from bremsstrahlung is shown to be 5% for electron temperatures from 1 to 50 MeV. We study bremsstrahlung generated in solid target interaction showing an electron temperature of 0.56 ± 0.04 MeV for a 700 µm Ti titanium target and 0.53 ± 0.03 MeV for a 50 µm target. We investigate bremsstrahlung from a target irradiated by laser-wakefield accelerated electrons showing an endpoint energy of 551 ± 5 MeV, inverse Compton generated x rays with a peak energy of 1.1 MeV, and calibrated radioactive sources. The total energy range covered by all these sources ranges from 10 keV to 551 MeV.

3.
Phys Rev Lett ; 127(10): 104801, 2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-34533351

RESUMO

Hollow plasma channels are attractive for lepton acceleration because they provide intrinsic emittance preservation regimes. However, beam breakup instabilities dominate the dynamics. Here, we show that thin, warm hollow channels can sustain large-amplitude plasma waves ready for high-quality positron acceleration. We verify that the combination of warm electrons and thin hollow channels enables positron focusing structures. Such focusing wakefields unlock beam breakup damping mechanisms. We demonstrate that such channels emerge self-consistently during the long-term plasma dynamics in the blowout's regime aftermath, allowing for experimental demonstration.

4.
Sci Rep ; 11(1): 14368, 2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34257331

RESUMO

We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

5.
Phys Rev Lett ; 125(1): 014801, 2020 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-32678646

RESUMO

We report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched ∼200-MeV electrons as they emerge from a laser-driven plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to a COTRI model, is ∼9× smaller than the ∼3 mrad ensemble beam divergence, while the radius of the microbunched beam, obtained from COTR images on the same shot, is <3 µm. The combined results show that the microbunched distribution has estimated transverse normalized emittance ∼0.4 mm mrad.

6.
Opt Lett ; 35(24): 4087-9, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21165098

RESUMO

We demonstrate a frequency-domain streak camera (FDSC) that captures the picosecond time evolution of luminal-velocity refractive index structures in a single shot. In our prototype FDSC, a probe-reference pulse pair propagates obliquely to a subpicosecond pump pulse that creates an evolving nonlinear index structure in glass, supplementing a conventional frequency-domain holographic probe-reference pair that copropagates with the pump. A single spectrometer acquires data from both pairs via spatial or temporal multiplexing, demonstrating the feasibility of a compact frequency-domain tomographic system in which a single spectrometer processes data from multiple probing angles.

7.
Phys Rev Lett ; 98(12): 123902, 2007 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-17501124

RESUMO

We report controlled enhancement of optical third harmonic generation (THG) from hydrodynamically expanding clusters of approximately 6x10(5) noble-gas atoms several hundred femtoseconds following ionization and heating by ultrashort pump pulses. This resonant enhancement is more pronounced for orthogonal than for parallel pump-probe polarizations, a consequence of faster cluster expansion along the pump polarization. Simulations show that the nonlinear susceptibility chi(3) of the individual clusters and the coherence length of the clustered plasma medium are optimized nearly simultaneously as the clusters expand, and both contribute to the observed THG enhancement. This dual enhancement mechanism may be scalable to relativistic probe intensity and to generation of high-order harmonics in the soft-x-ray regime.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA