Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Cardiol ; 47(3): e24217, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38439605

RESUMO

BACKGROUND: Radiofrequency ablation has been applied for the treatment of hypertrophic obstructive cardiomyopathy (HOCM). The two known procedures are percutaneous intramyocardial septal radiofrequency ablation (PIMSRA) and endocardial radiofrequency septal ablation (ERSA). METHODS: This study presents a retrospective analysis of the PIMSRA and ERSA procedures in patients with drug-refractory HOCM. A total of 28 patients participated in the study, with 12 receiving PIMSRA and 16 receiving ERSA. The objective of our study was to compare the short-term effects of these two radiofrequency ablation procedures. RESULTS: At the 30-day follow-up, the PIMSRA group demonstrated a greater reduction in left ventricular outflow tract peak gradient at rest compared to the ERSA group (22.25 [16.72] mmHg versus 47.75 [21.94] mmHg) (p < .01). The values for the PIMSRA group decreased from 99.33 (32.00) mmHg to 22.25 (16.72) mmHg (p < .01), while the ERSA group decreased from 97.75 (30.24) mmHg to 47.75 (21.94) mmHg (p < .01). Only the PIMSRA group exhibited a decrease in mitral regurgitation (MR). The area of MR decreased from 10.13 (4.12) mm2 to 3.65 (2.80) mm2 in the PIMSRA group (p < .01). Additionally, the PIMSRA group experienced reductions in left atrial diameter (LAD) and left ventricular ejection fraction (LVEF)%. The values for LAD changed from 43.58 (7.53) mm to 37.08 (6.92) mm (p = .03), and the values for LVEF% decreased from 65.75 (6.12) pg/mL to 60.83 (4.06) pg/mL (p = .03). CONCLUSION: In terms of the two types of radiofrequency ablation methods used in HOCM, it has been observed that PIMSRA demonstrates a more favorable early treatment effect compared to ERSA.


Assuntos
Apêndice Atrial , Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Ablação por Radiofrequência , Humanos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia
2.
Zhonghua Yu Fang Yi Xue Za Zhi ; 47(1): 59-62, 2013 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-23601525

RESUMO

OBJECTIVE: To establish and compare the method of static headspace gas chromatography hydrogen flame detector (static headspace method) and purge and trap gas chromatography-mass spectrometry (dynamic headspace method) of anisole in water. METHODS: Nitrogen gas was used as carrier gas in the static headspace method, 5 g NaCl as matrix modifier was added into 10 ml water. The sample was balanced with high speed vibration at 75°C for 30 min, and anisole was detected by gas chromatography and quantified with external standard. Helium was used as carrier gas in dynamic headspace method, 5.0 ml water and 0.004 mg/L internal standard fluorobenzene was purged into the purge and trap apparatus. After purging, trapping and desorption, anisole was detected by the gas chromatography-mass spectrograph, confirmed by the retention time and comparison of mass-spectrogram in spectrum library and quantified with internal standard. The repeatability and sensitivity of assay were evaluated. RESULTS: A good linear range for anisole was observed in static headspace gas chromatography and dynamic headspace gas chromatography-mass spectrometry, within the range of 10 - 500 µg/L and 0.5 - 60.0 µg/L respectively. The linear regression equation was Y = 782.150X + 1.3446 and Y = 0.0358X - 0.0209 respectively, both the correlation coefficient ≥ 0.999. The detection limit (LOD) were 0.002 µg/L and 0.110 µg/L, the lower limit of quantitation (LOQ) were 0.006 µg/L and 0.350 µg/L, the relative standard deviation (RSD) were 1.8% - 2.3% and 2.0% - 3.4%, and the spiking recovery were 93% - 101% and 96% - 101% respectively. CONCLUSION: The methods of static headspace gas chromatography and dynamic headspace gas chromatography-mass spectrometry are simple and can measure anisole in water quickly, sensitively and accurately.


Assuntos
Anisóis/análise , Cromatografia Gasosa/métodos , Água/química , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA