Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Prev Med Rep ; 39: 102639, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38357224

RESUMO

Objectives: The Albumin-Bilirubin (ALBI) score has been widely used to assess the prognosis in patients with cirrhosis and hepatocellular carcinoma. This study aimed to analyze the relationship between ALBI score and all-cause mortality in patients with hepatitis B virus (HBV) infection in general. Methods: Patients aged ≥ 18 years with previous or current HBV infection from the National Health and Nutrition Examination Survey (NHANES) in the United States between 1999 and 2018 were enrolled in this retrospective cohort study. Weight univariate and multivariate Cox regression models were used to assess the relationship between ALBI score and all-cause mortality. The area under the receiver operating characteristic curve (AUC) was utilized to assess the predictive effect of ALBI score for all-cause mortality. Results: A total of 3,666 patients were included, of whom 925 (23.53 %) patients died. Compared with ALBI score ≤ -2.6, HBV-infected patients with ALBI score > -2.6 [hazard ratio (HR) = 1.75; 95 % confidence interval (CI): 1.43-2.14] were corrected with a higher all-cause mortality risk after adjusting for confounders. Stratified analyses showed that higher ALBI score was related to a higher risk of all-cause mortality in different patients with HBV infection (All P < 0.05). Furthermore, the ALBI score had good predictive ability for 1-year (AUC = 0.816, 95 %CI: 0.754-0.878), 3-year (AUC = 0.808, 95 %CI: 0.775-0.841), 5-year (AUC = 0.809, 95 %CI: 0.783-0.835), and 10-year (AUC = 0.806, 95 %CI: 0.784-0.827) all-cause mortality. Conclusion: Higher ALBI score was related to a higher risk of all-cause mortality in patients with HBV infection, and the ALBI score showed a good predictive effect for short- and long-term all-cause mortality.

2.
J Ophthalmol ; 2022: 1910607, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35321348

RESUMO

Purpose: To analyze tear function outcomes following collagen cross-linking (CXL) treatment in ectatic corneas. Methods: Fifty-seven eyes of 34 patients were included, and patients with keratoconus who underwent epithelium-on (epi-on) or epithelium-off (epi-off) CXL were evaluated. The following tests were performed preoperatively and at 1, 3, 6, and 12 months postoperatively: best-corrected visual acuity (BCVA), maximum keratometry value (Kmax), ocular surface disease index (OSDI) questionnaire, slit-lamp examination, tear meniscus height, first noninvasive Keratograph breakup time (1st NIKBUT), average NIKBUT, and bulbar redness. Results: BCVA improved in both epi-on and epi-off groups at most follow-up points, but was not significantly different between groups. At 12-month follow-up, Kmax in the epi-on and epi-off groups improved after CXL, but there was no significant difference between the groups. The OSDI in both groups decreased after operation compared with before surgery, and there was no significant difference between the two groups. Comparing the two groups, only the change in the tear meniscus height at 6 months postoperatively was statistically significant, and the pre- and postoperative values of the two groups were within the normal range (>0.20 mm). The change was small and had no clinical significance. There was no change in the 1st NIKBUT and average NIKBUT between the epi-on and epi-off groups. A change in bulbar redness was significantly better in the epi-off group than in the epi-on group at 3 months postoperatively. Comparing the effects at 1 year postoperatively, both groups had positive results in OSDI, NIKBUT, tear meniscus height, and bulbar redness. Conclusion: Both epi-on and epi-off CXL can control the progression of keratoconus, although epi-off CXL is more effective. Both methods have a positive effect on dry eye, which can improve the condition of the tear film and reduce dry eye symptoms in patients with keratoconus.

3.
BMC Ophthalmol ; 21(1): 256, 2021 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112149

RESUMO

BACKGROUND: To evaluate the necessity of cycloplegia for epidemiological studies of refraction in Chinese young adults (aged 17-22 years) with dark irises, and to compare the cycloplegic effects of 1% cyclopentolate and 0.5% tropicamide in them. METHODS: A total of 300 young adults (108 males and 192 females) aged 17 to 22 years (mean 19.03 ± 1.01) were recruited from Tianjin Medical University from November 2019 to January 2020. Participants were randomly divided into two groups. In the cyclopentolate group, two drops of 1% cyclopentolate eye drop were administrated (one drop every 5 min), followed by autorefraction and subjective refraction 30 to 45 min later. In the tropicamide group, four drops of 1% Mydrin P (Tropicamide 0.5%, phenylephrine HCl 0.5%) eye drop were given (one drop every 5 min), followed by autorefraction and subjective refraction 20 to 30 min later. The participants and the examiners were masked to the medication. Distance visual acuity, intraocular pressure (IOP), non-cycloplegic and cycloplegic autorefraction (Topcon KR-800, Topcon Co. Tokyo, Japan), non-cycloplegic and cycloplegic subjective refraction and ocular biometry (Lenstar LS-900) were performed. RESULTS: The values of spherical equivalent (SE) and sphere component were significantly different before and after cycloplegia in the cyclopentolate group and the tropicamide group (p < 0.05). The mean difference between noncycloplegic and cycloplegic autorefraction SE was 0.39 D (±0.66 D) in the cyclopentolate group and 0.39 D (±0.34 D) in the tropicamide group. There was no significant difference in the change of SE and sphere component after cycloplegia between the cyclopentolate group and the tropicamide group (p > 0.05). In each group, no significant difference was found between autorefraction and subjective refraction after cycloplegia (p > 0.05). We also found that more positive or less negative cycloplegic refraction was associated with the higher difference in SE in each group. CONCLUSIONS: Cycloplegic refractions were generally more positive or less negative than non-cycloplegic refractions. It is necessary to perform cycloplegia for Chinese young adults with dark irises to obtain accurate refractive errors. We suggest that cycloplegic autorefraction using tropicamide may be considered as a reliable method for epidemiological studies of refraction in Chinese young adults with dark irises. TRIAL REGISTRATION: The study was registered on September 7, 2019 (Registration number: ChiCTR1900025774 ).


Assuntos
Ciclopentolato , Erros de Refração , China , Feminino , Humanos , Japão , Masculino , Midriáticos , Refração Ocular , Erros de Refração/diagnóstico , Erros de Refração/tratamento farmacológico , Tóquio , Tropicamida , Adulto Jovem
4.
Cancer Biol Med ; 18(1): 199-205, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33628594

RESUMO

Objective: Because of the poor prognosis of lacrimal adenoid cystic carcinoma (LACC), we aimed to investigate the effects of perineural invasion (PNI) and consequent aberrations in GDNF/GFRα-1/RET protein expression on LACC recurrence. Methods: Clinicopathological data for 51 histologically confirmed patients with LACC enrolled between 2001 and 2017 were retrospectively analyzed. Hematoxylin and eosin staining was applied to assess PNI. Tissue-based immunohistochemistry (IHC) detection of GDNF, GFRα-1, and RET proteins was performed on LACC formalin-fixed, paraffin-embedded specimens. We generated semi-quantitative data of the IHC results and compared them with the clinicopathological data for the 51 patients. Results: Of the 51 patients, 19 (37.3%) were PNI positive. Recurrence was more common for LACC with than without PNI (73.7% vs. 37.5%, P = 0.01). GDNF, GFRα-1, and RET proteins were expressed in 62.7%, 62.7%, and 54.9% of the 51 patients with LACC, respectively. The expression of all 3 proteins was more common in patients with than without PNI. In agreement with previous findings, PNI-associated GFRα-1 and RET positivity, as detected by IHC, remained significantly associated with recurrence, whereas GDNF expression, as detected by IHC, was not correlated with LACC recurrence. Specifically, patients with concurrent GFRα-1 and RET expression may have a high risk of PNI (89.5% positivity rate) and recurrence (84.2% positivity rate). Conclusions: PNI may contribute to LACC recurrence. The concurrent expression of GFRα-1 and RET proteins, as detected by IHC, may potentially be associated with LACC PNI and recurrence.


Assuntos
Carcinoma Adenoide Cístico/metabolismo , Receptores de Fator Neurotrófico Derivado de Linhagem de Célula Glial/metabolismo , Aparelho Lacrimal , Proteínas Proto-Oncogênicas c-ret/metabolismo , Neoplasias das Glândulas Salivares/metabolismo , Carcinoma Adenoide Cístico/patologia , Feminino , Fator Neurotrófico Derivado de Linhagem de Célula Glial/metabolismo , Humanos , Imuno-Histoquímica , Masculino , Recidiva Local de Neoplasia , Estudos Retrospectivos , Neoplasias das Glândulas Salivares/patologia
5.
Asian J Psychiatr ; 56: 102559, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33465748

RESUMO

OBJECTIVE: Abnormalities of global visual scanning have been well-recognized in schizophrenia patients. However, its relevance to various cognitive domains is still understudied. In the present study, we identified the association between global visual scanning and cognitive function in schizophrenia. METHODS: Eye movement was captured and analyzed in 28 individuals with schizophrenia and 21 healthy controls in free viewing test. The MATRICS consensus cognitive battery (MCCB) was applied to evaluate cognitive function. RESULTS: Consistent with previous reports, schizophrenia patients exhibited several eye movement abnormalities during global visual scanning and showed cognition deficits in MCCB test as compared with healthy controls. Fixation duration was significantly related to cognitive dysfunction in schizophrenia. Moreover, there was a potential that eye movement measures during landscape scanning, rather than face scanning, were preferentially related to cognitive dysfunction. CONCLUSION: This study indicated the association between free visual scanning and various cognitive functions in schizophrenia, shedding light on the possibility that some eye movement measures during visual exploration could be a biomarker for cognitive deficits in schizophrenia.


Assuntos
Transtornos Cognitivos , Disfunção Cognitiva , Esquizofrenia , Cognição , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/etiologia , Humanos , Testes Neuropsicológicos , Esquizofrenia/complicações , Psicologia do Esquizofrênico
6.
Int J Ophthalmol ; 13(10): 1660-1666, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33078119

RESUMO

AIM: To evaluate the effectiveness of Grand Seiko Ref/Keratometer WAM-5500 compared to Topcon KR800 autorefractor in detecting refractive error in large scale vision screening for Chinese school age children with the WHO criteria. METHODS: A total of 886 participants were enrolled with mean age of 9.49±1.88y from Tianjin, China. Spherical equivalent (SE) was obtained from un-cycloplegic autorefraction and cycloplegic autorefraction. Topcon KR 800 (Topcon) and Grand Seiko WAM-5500 (WAM) autorefractors were used. Bland-Altman Plot and regression were generated to compare their performance. The overall effectiveness of detecting early stage refractive error was analyzed with receiver operating characteristic (ROC) curves. RESULTS: The mean SE was -0.98±1.81 diopter (D) and the prevalence of myopia was 48.9% defined by WHO criteria according to the result of cycloplegic autorefraction. The mean SE of un-cycloplegic autorefraction with Topcon and WAM were -1.21±1.65 and -1.20±1.68 D respectively. There was a strong linear agreement between result obtained from WAM and cycloplegic autorefraction with an R2 of 0.8318. Bland-Altman plot indicated a moderate agreement of cylinder values between the two methods. The sensitivity and specificity for detecting hyperopia were 90.52% and 83.51%; for detecting myopia were 95.60% and 90.24%; for detecting astigmatism were 79.40% and 90.21%; for detecting high myopia were 98.16% and 98.91% respectively. CONCLUSION: These findings suggest that both Grand Seiko and Topcon autorefractor can be used in large-scale vision screening for detecting refractive error in Chinese population. Grand Seiko gives relatively better performance in detecting myopia, hyperopia, and high myopia for school age children.

7.
Artigo em Inglês | MEDLINE | ID: mdl-21779239

RESUMO

We investigate how network structure can influence the tendency for a neuronal network to synchronize, or its synchronizability, independent of the dynamical model for each neuron. The synchrony analysis takes advantage of the framework of second order networks, which defines four second order connectivity statistics based on the relative frequency of two-connection network motifs. The analysis identifies two of these statistics, convergent connections, and chain connections, as highly influencing the synchrony. Simulations verify that synchrony decreases with the frequency of convergent connections and increases with the frequency of chain connections. These trends persist with simulations of multiple models for the neuron dynamics and for different types of networks. Surprisingly, divergent connections, which determine the fraction of shared inputs, do not strongly influence the synchrony. The critical role of chains, rather than divergent connections, in influencing synchrony can be explained by their increasing the effective coupling strength. The decrease of synchrony with convergent connections is primarily due to the resulting heterogeneity in firing rates.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA