Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Zhongguo Gu Shang ; 34(1): 45-50, 2021 Jan 25.
Artigo em Chinês | MEDLINE | ID: mdl-33666019

RESUMO

OBJECTIVE: To compare accuracy of anterior cervical pedicle screws between assist of rapid prototyping 3D guide plate and free-hand insertion, and evaluate the safety of two methods. METHODS: Eight adult cervical cadaver specimens after formaldehyde immersion, including 4 males and 4 females, aged 32 to 65(40.3±5.6) years old. After X-ray examination to exclude bone damage and deformity, 4 of them (3D guide plate group) randomly selected were for CT scan to obtain DICOM format data, and the data was imported into Mimics software for model, designed the ideal entry point and nail path for anterior cervicaltranspedicular screw (ATPS). After obtaining the personalized guide plate of the nail channel, it was exported as STL data, and the individual guide plate was printed by rapid prototyping and 3D printing technology. In turn, with the assistance of 3D guide plates, one-to-one personalized ATPS screws were placed on the four lower cervical cadaver specimens. Another 4 (free-hand group) lower cervical cadaver specimens were implanted with ATPS screws using free-hand technique. All specimens were performed CT thin-layer scanning and three-dimensional reconstruction after operation. The Tomasino method was used to evaluate the safety of the screws on the CT cross-sectional and sagittal images, to determine whether there was a cortical puncture of the lower and inner edges of the pedicle. According to the CT rating results, gradeⅠandⅡwere safe, and grade Ⅲ- Ⅴ were dangerous.And the accuracy of screws was recorded and analyzed between two groups. RESULTS: Two screws were inserted in each segment from C3 to C7 in 8 adult cadavers. A total of 80 screws were inserted, 40 in the 3D guide plate group, and 40 in the free-hand group. The Tomasino screw rating method was used to evaluate the safety of screw, 21 screws were gradeⅠ, 14 screws were gradeⅡ, 3 screws were grade Ⅲ, 1 screw was grade Ⅳ, 2 screws were grade Ⅴ in 3D guide plate group, while 14 screws were gradeⅠ, 8 screws were gradeⅡ, 8 screws were grade Ⅲ, 6 screws were grade Ⅳ, 2 screws were grade Ⅴ in free-hand group. The safety rate of 3D guide plate group was 87.5%, and 55.0% of the free hand group (χ2=8.7, P=0.003). CONCLUSION: The 3D printing rapid prototyping guide plate assisted insertion of the anterior cervical pedicle screw can significantly improve the accuracy and safety, and provide a theoretical basis for further clinical application.


Assuntos
Vértebras Cervicais , Parafusos Pediculares , Adulto , Idoso , Placas Ósseas , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Impressão Tridimensional
2.
Zhonghua Yi Xue Za Zhi ; 91(5): 337-9, 2011 Feb 01.
Artigo em Chinês | MEDLINE | ID: mdl-21419011

RESUMO

OBJECTIVE: To investigate the effects of EMPs on HUVECs permeability in vitro, then evaluate the effect on the Avascular Necrosis of Femoral Head. METHODS: Incubate HUVECs with EMPs which is released by HUVECs in vitro, then estimate the endothelial permeability. RESULTS: Flow cytometry analysis showed that EMPs were released at maximum concentration(7.66 × 10(4)/ml) after 24 hours stimulated by 10 mmol DEX And 7.66 × 10(4), 7.66 × 10(3)/ml concentration (moderate and high concentrations) of EMPs caused injury to the permeability of HUVECs (P values are 0.002 and 0.031 respectively, < 0.05), while 7.66 × 10(2)/ml concentration (low concentration) of EMPs didn't (P = 0.425 > 0.05). CONCLUSION: Dexamethasone can induce HUVECs to release EMPs in vitro. EMPs caused collapse of connections of HUVECs, and increase the HUVECs permeability, decrease vascular stability, finally lead to Avascular Necrosis of Femoral Head.


Assuntos
Membrana Celular/metabolismo , Células Endoteliais/metabolismo , Necrose da Cabeça do Fêmur/metabolismo , Permeabilidade da Membrana Celular , Células Cultivadas , Endotélio Vascular/citologia , Endotélio Vascular/metabolismo , Necrose da Cabeça do Fêmur/patologia , Humanos , Veias Umbilicais/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA