Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Br J Anaesth ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38839471

RESUMO

BACKGROUND: The comparative effectiveness of volatile anaesthesia and total intravenous anaesthesia (TIVA) in terms of patient outcomes after cardiac surgery remains a topic of debate. METHODS: Multicentre randomised trial in 16 tertiary hospitals in China. Adult patients undergoing elective cardiac surgery were randomised in a 1:1 ratio to receive volatile anaesthesia (sevoflurane or desflurane) or propofol-based TIVA. The primary outcome was a composite of predefined major complications during hospitalisation and mortality 30 days after surgery. RESULTS: Of the 3123 randomised patients, 3083 (98.7%; mean age 55 yr; 1419 [46.0%] women) were included in the modified intention-to-treat analysis. The composite primary outcome was met by a similar number of patients in both groups (volatile group: 517 of 1531 (33.8%) patients vs TIVA group: 515 of 1552 (33.2%) patients; relative risk 1.02 [0.92-1.12]; P=0.76; adjusted odds ratio 1.05 [0.90-1.22]; P=0.57). Secondary outcomes including 6-month and 1-yr mortality, duration of mechanical ventilation, length of ICU and hospital stay, and healthcare costs, were also similar for the two groups. CONCLUSIONS: Among adults undergoing cardiac surgery, we found no difference in the clinical effectiveness of volatile anaesthesia and propofol-based TIVA. CLINICAL TRIAL REGISTRATION: Chinese Clinical Trial Registry (ChiCTR-IOR-17013578).

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 22(1): 139-42, 2002 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-12940052

RESUMO

In this paper, the decomposition method of sulfur and the determination of trace arsenic in sulfur by GFAAS with La(NO3)3-Ni(NO3)2 matrix modifier were studied in detail. The decomposition of sulfur with mixed acid HNO3-HClO4 by controlled temperature electrothermal method or pressure crucible method was efficient and safe. The sensitivity of the determination of arsenic with La(NO3)3-Ni(NO3)2 matrix modifier was higher than with Ni(NO3)2 or Mg(NO3)2 matrix modifiers. The detection limit was 0.034 microgram.mL-1 (k = 3). The analytical results of the sulfur samples were coincident with the results of determination by HG-ICP-AES. The adding recoveries were 97.5%-110% and the relative standard deviation was less than or equal to 2.1% (n = 4).


Assuntos
Arsênio/análise , Enxofre/química , Lantânio , Níquel , Espectrofotometria Atômica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA