1.
Micromachines (Basel) ; 13(12)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36557407

RESUMO

Protoplasts are widely used in gene function verification, subcellular localization, and single-cell sequencing because of their complete physiological activities. The traditional methods based on tissues and organs cannot satisfy the requirement. Therefore, the isolation and capture of a single protoplast are most important to these studies. In this study, a dual-channel microfluidic chip based on PDMS with multi-capture cavities was designed. The design theory of the dual-channel microfluidic chip's geometry was discussed. The capture mechanism of the single cell in a dual-channel microfluidic chip was studied by simulation analysis. Our results showed that a single polystyrene microsphere or tobacco protoplast was successfully isolated and trapped in this chip. The capture efficiency of the chip was 83.33% for the single tobacco protoplast when the inlet flow rate was 0.75 µL/min. In addition, the dynamic capture of the polystyrene microsphere and tobacco protoplasts was also presented. Overall, our study not only provided a new strategy for the subsequent high throughput single protoplast research, but also laid a theoretical foundation for the capture mechanism of the single cell.