Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
iScience ; 27(6): 110023, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38957788

RESUMO

We delve into the distinctive color gamut characteristics resulting from color dispersion of surface relief grating (SRG) and wavelength degeneracy of volume holographic optical element (VHOE) in a diffractive light guide. While a laser-like spectrum achieves an impressive 194% sRGB color gamut for both cases, it proves unsuitable for VHOE light guides due to limitations in breaking the field of view (FOV) of the display. Conversely, a broad-band light source, such as LEDs, offers continuous FOV but reduces the common color gamut to 50% sRGB. We then present a newly designed VHOE light guide capable of achieving the common color gamut of 130% sRGB using two multiplexed holograms of each color, closely matching the 133% sRGB achieved by an SRG light guide. This article presents the first theoretical methodology to elucidate color performance of diffractive light guides utilizing VHOEs with holographic multiplexing, affirming their suitability for crafting high-quality near-eye display.

2.
Eur J Med Res ; 28(1): 155, 2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37085944

RESUMO

BACKGROUND: Positive fluid balance and tissue fluid accumulation are associated with adverse outcomes in sepsis. Vascular endothelial growth factor (VEGF) increases in sepsis, promotes vascular permeability, and may affect tissue fluid accumulation and oxygenation. We used near-infrared spectroscopy (NIRS) to estimate tissue hemoglobin (Hb) oxygenation and water (H2O) levels to investigate their relationship with serum VEGF levels. MATERIAL AND METHODS: New-onset severe sepsis patients admitted to the intensive care unit were enrolled. Relative tissue concentrations of oxy-Hb ([HbO2]), deoxy-Hb ([HbR]), total Hb ([HbT]), and H2O ([H2O]) were estimated by near-infrared spectroscopy (NIRS) for three consecutive days and serum VEGF levels were measured. Comparisons between oliguric and non-oliguric patients were conducted and the correlations between variables were analyzed. RESULTS: Among 75 eligible patients, compared with non-oliguric patients, oliguric patients were administrated more intravascular fluids (median [IQR], 1926.00 [1348.50-3092.00] mL/day vs. 1069.00 [722.00-1486.75] mL/day, p < 0.001) and had more positive daily net intake and output (mean [SD], 1,235.06 [1303.14] mL/day vs. 313.17 [744.75] mL/day, p = 0.012), lower [HbO2] and [HbT] over the three-day measurement (analyzed by GEE p = 0.01 and 0.043, respectively) and significantly higher [H2O] on the third day than on the first two days (analyzed by GEE p = 0.034 and 0.018, respectively). Overall, serum VEGF levels were significantly negatively correlated with [HbO2] and [HbT] (rho = - 0.246 and - 0.266, p = 0.042 and 0.027, respectively) but positively correlated with [H2O] (rho = 0.449, p < 0.001). Subgroup analysis revealed a significant correlation between serum VEGF and [H2O] in oliguric patients (rho = 0.532, p = 0.003). Multiple regression analysis determined the independent effect of serum VEGF on [H2O] (standardized coefficient = 0.281, p = 0.038). CONCLUSIONS: In severe sepsis, oliguria relates to higher positive fluid balance, lower tissue perfusion and oxygenation, and progressive tissue fluid accumulation. Elevated serum VEGF is associated with worsening tissue perfusion and oxygenation and independently affects tissue fluid accumulation.


Assuntos
Sepse , Fator A de Crescimento do Endotélio Vascular , Humanos , Hemoglobinas/metabolismo , Estudos Prospectivos , Reperfusão , Sepse/metabolismo , Sepse/patologia , Fator A de Crescimento do Endotélio Vascular/sangue , Fator A de Crescimento do Endotélio Vascular/metabolismo
3.
Sci Rep ; 13(1): 3263, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36828951

RESUMO

Since venous reflux is difficult to quantify, triggered angiography non-contrast-enhanced (TRANCE)-magnetic resonance imaging (MRI) is a novel tool for objectively evaluating venous diseases in the lower extremities without using contrast media. This study included 26 pre-intervention patients with superficial venous reflux in the lower extremities and 15 healthy volunteers. The quantitative flow (QFlow) analyzed the phase shift information from the pixels within the region of interest from MRI. The fast and simple radial basis function neural network (RBFNN) learning model is constructed by determining the parameters of the radial basis function and the weights of the neural network. The input parameters were the variables generated through QFlow, while the output variables were morbid limbs with venous reflux and normal limb classification. The stroke volume, forward flow volume, absolute stroke volume, mean flux, stroke distance, and mean velocity of greater saphenous veins from QFlow analysis could be used to discriminate the morbid limbs of pre-intervention patients and normal limbs of healthy controls. The neural network successfully classified the morbid and normal limbs with an accuracy of 90.24% in the training stage. The classification of venous reflux using the RBFNN model may assist physicians in clinical settings.


Assuntos
Perna (Membro) , Insuficiência Venosa , Humanos , Extremidade Inferior , Veia Safena/patologia , Imageamento por Ressonância Magnética
4.
Opt Express ; 30(19): 33792-33803, 2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36242406

RESUMO

This paper proposed a holographic optical element as a see-through screen for the computer-generated hologram projection system with 3D images. The proposed holographic screen consisted of a linear grating and a lens phase. The linear grating is used to redirect the information light and guide information into the observer's eye and achieve the see-through function. The lens phase is used to magnify the field of view of the holographic projection system. The aberration caused by the screen was analyzed in this paper and the aberration can be pre-corrected in the hologram calculation algorithm. Finally, the proposed system achieved 20.3 by 14.3 degrees field of view at 532 nm laser based on the spatial light modulator with 6.4 µm pixels.

5.
Quant Imaging Med Surg ; 12(10): 4953-4967, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36185059

RESUMO

Background: Tissue oedema affects tissue perfusion and interferes with the monitoring of tissue oxygenation in patients with severe sepsis. However, the underlying mechanisms remain unclear. We used a wireless near-infrared spectroscopy (NIRS) device that transmits tri-wavelength light to quantify tissue haemoglobin (Hb) and water (H2O) content. We estimated tissue H2O in severe sepsis patients and healthy controls, compared their difference, and investigated the correlation of tissue H2O with systemic haemodynamics and its impact on tissue oxygenation. Methods: Seventy-seven adult patients with new-onset severe sepsis admitted to the intensive care unit within 72 h and 30 healthy volunteers (controls) were enrolled. The NIRS device was placed on the participant's leg to estimate the relative tissue concentrations of oxy-Hb ([HbO2]), deoxy-Hb ([HbR]), total Hb ([HbT]), and H2O ([H2O]) at rest for three consecutive days. Two-sample t-test or Mann-Whitney U test, chi-square test, and generalised estimating equations (GEEs) were used for comparisons. Results: In severe sepsis patients, the [H2O] in the anterior tibia was higher [mean (standard deviation, 95% confidence interval), 10.57 (3.37, 9.81-11.34) vs. 7.40 (1.89, 6.70-8.11)] and the [HbO2], [HbT], and tissue Hb oxygen saturation (StO2) were lower [0.20 (0.01, 0.20-0.20) vs. 0.22 (0.01, 0.22-0.23), 0.42 (0.02, 0.42-0.43) vs. 0.44 (0.02, 0.44-0.45), and 47.25% (1.97%, 46.80-47.70%) vs. 49.88% (1.26%, 49.41-50.35%), respectively] than in healthy controls in first-day measurements. GEE analysis revealed significant differences in [H2O], [HbO2], [HbT], and StO2 between groups over three consecutive days (all P≤0.001). In addition, [HbO2] and StO2 levels gradually decreased over time in the patient group. A negative correlation was observed between [H2O] and [HbO2] and StO2, which became more obvious over time (day 1: r=-0.51 and r=-0.42, respectively; both P<0.01; day 3: r=-0.67 and r=-0.63, respectively, both P<0.01). Systolic arterial pressure was positively related to [H2O] (r=0.51, P<0.05, on day 1) but was not associated with tissue oxygenation parameters. Conclusions: NIRS can be used to quantify tissue H2O. Severe sepsis patients have increased tissue H2O, which responds to changes in arterial blood pressure and affects tissue oxygenation.

6.
Opt Lett ; 47(18): 4782-4785, 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36107089

RESUMO

A see-through display based on a planar holographic waveguide with a tunable focal plane is presented. A negative liquid crystal lens is attached on the outcoupling location of the waveguide to manipulate the image distance. The continuous tunable range for the focal length is from negative infinity to -65 cm. The demonstrated prototype system provides 10.5° field-of-view (FOV) for the images not locating at infinity. The FOV for the images not locating at infinity is limited by the diameter of the liquid crystal lens. The lens function of the liquid crystal lens is polarization dependent. By controlling the polarization states of the real scene and the input information image, the liquid crystal lens keeps the see-through function for a real scene and simultaneously plays the role of a negative lens for the input information image. Compared to the see-through display system with a single focal plane, the presented system offers a more comfortable augmented reality (AR) experience.

7.
Opt Express ; 29(23): 38615-38622, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34808911

RESUMO

This paper proposes a binocular holographic floating display. The device consists of two phase-modulation spatial light modulators (SLM) and a dihedral corner reflector array (DCRA) element. The conjugate images of the SLMs generated by the DCRA become the system's exit pupils. Exit pupils that are larger than the pupils of human eyes are arranged to locate at the position of observer's eyes. Therefore, the dimension of the SLM will not limit the viewing angle, although the pixel pitch of the SLM still limits the maximum field of view. For the laser light source, the resolution of the images can achieve 3 arc minutes when the distance between images and DCRA is less than 20 cm. The full-color display function is also performed in the proposed device.

8.
Phlebology ; 35(10): 814-823, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32700650

RESUMO

BACKGROUND: Venous leg ulcers, or static leg ulcers, are chronic wounds associated with ambulatory venous hypertension of the lower extremities as a consequence of venous valve reflux, reduce venous capacitance, poor calf venous pump, heart failure, or in conjunction with venous obstruction. A static ulcer with venous thrombosis in a pelvic or thigh vein responds favorably to anticoagulation agents. However, anticoagulation is less effective and even harmful when ambulatory venous hypertension has another cause such as venous reflux, poorly heart function, and poor calf venous pump. METHOD: TRiggered Angiography Non-Contrast-Enhanced (TRANCE) magnetic resonance imaging (MRI) exploits differences in vascular signal intensity during the cardiac cycle for subsequent image subtraction, providing detailed radiation-free venograms without the use of contrast agents. The method is a new tool for evaluating the presence of thrombosis in the venous systems. TRANCE-MRI was employed to document the existence of venous thrombosis within the eight patients in this study. Subsequently, we used a wireless wearable near-infrared spectroscopy device to compare deep vein thrombosis-associated and non-deep vein thrombosis-associated static ulcers. The sampling depths were 5 and 10 mm, representing the dermis and subcutaneous tissue, respectively. RESULT: There are four patients with venous leg ulcers proven with venous thrombosis by TRANCE-MRI and are classified as deep vein thrombosis group. Compared with the non-deep vein thrombosis group, the deep vein thrombosis group had less deoxyhemoglobin, less total hemoglobin, and a significantly lower H2O signal in the 5-mm sampling depth (dermis level). And eight health participants were included as control group. Wounded patients (including deep vein thrombosis and non-deep vein thrombosis patients) have higher H2O concentration on the 5-mm depth sampling than control group. In the 10-mm sampling depth (subcutaneous level), the deoxyhemoglobin and tissue oxygen saturation of the deep vein thrombosis group were lower than those of the non-deep vein thrombosis group, and the H2O concentration was higher than non-deep vein thrombosis group. Patients with static foot ulcers and deep vein thrombosis had similar oxyhemoglobin, deoxyhemoglobin, total hemoglobin, and tissue oxygen saturation than did those without deep vein thrombosis in 5-mm depth sampling (dermis level). Notably, the H2O signal of patients with non-deep vein thrombosis-associated static ulcers was higher for the 5-mm sampling depth. CONCLUSION: In patients with static ulcers and deep vein thrombosis, the H2O level may be higher in the 10-mm sampling depth, indicating that those patients had more subcutaneous water. In patients with non-deep vein thrombosis static foot ulcer, the near-infrared spectroscopy (NIRS) indicated worse fluid retention in the dermis level. The H2O value in the NIRS may be different owing to underline the cause of the venous leg ulcers.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Úlcera Varicosa , Trombose Venosa , Dispositivos Eletrônicos Vestíveis , Angiografia , Humanos , Extremidade Inferior , Imageamento por Ressonância Magnética , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Úlcera
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA