Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Aging Cell ; 23(3): e14055, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38044578

RESUMO

The heterogeneity of aging has been investigated at cellular and organic levels in the mouse model and human, but the exploration of aging heterogeneity at whole-organism level is lacking. C. elegans is an ideal model organism for studying this question as they are self-fertilized and cultured in the same chamber. Despite the tremendous progress made in single-cell proteomic analysis, there is few single-worm proteomics studies about aging. Here, we apply single-worm quantitative mass spectrometry to quantify the heterogenous proteomic changes during aging across individuals, a total of 3524 proteins from 157 C. eleagns individuals were quantified. A reconstructed C. elegans aging trajectory and proteomic landscape of fast-aging individuals were used to analyze the heterogeneity of C. elegans aging. We characterized inter-individual proteomic variation during aging and revealed contributing factors that distinguish fast-aging individuals from their siblings.


Assuntos
Proteínas de Caenorhabditis elegans , Caenorhabditis elegans , Animais , Camundongos , Humanos , Caenorhabditis elegans/genética , Caenorhabditis elegans/metabolismo , Proteínas de Caenorhabditis elegans/genética , Proteínas de Caenorhabditis elegans/metabolismo , Proteômica/métodos , Envelhecimento , Modelos Animais de Doenças
2.
Lab Med ; 54(6): 598-602, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-36942666

RESUMO

OBJECTIVE: The acid/molybdate assay performed on the Beckman Coulter AU5821 could be subject to paraprotein interference, which potentially results in spurious hyperphosphatemia. We attempted to find a reliable solution to eliminate paraprotein interference in laboratory test results and discuss the causes of paraprotein interference. METHODS: We observed 50 multiple myeloma patients with serum paraproteins. We used the trichloroacetic acid (TCA) deproteinizing method to confirm that paraproteins indeed interfered with phosphate detection in the serum acid/molybdate assay. Furthermore, we used the dry chemical method (Vitros 5.1 FS, Johnson) and deionized water (H2O), normal saline (NS), and healthy human serum as alternative diluents. We assessed the clinical acceptability of the 4 methods by evaluating a bias percentage (bias%) lower than 10% under the premise of TCA treatment as a serum phosphate reference method. RESULTS: In total, comparing the results of the TCA treatment on the Beckman Coulter AU5821, 3/50 (6%) multiple myeloma patients exhibited phosphate pseudo-elevation (bias% >10%). Additionally, we found pseudo-hypophosphate only in immunoglobulin (Ig)G-kappa paraprotein samples, and all were above 50 g/L. The bias% between TCA and dry chemical method for the 3 patients was below 10%. The maximum acceptable dilutions for patient 22 were 8-fold H2O, 4-fold H2O , and 2-fold serum; those for patient 45 were 16-fold H2O, 16-fold H2O, and 2-fold serum. However, the bias% of patient 40 was beyond the acceptable range in all 3 dilution groups. CONCLUSION: High concentrations of IgG kappa-type paraproteins are more likely to interfere with serum phosphorous detection. Both the TCA and dry chemical method can effectively eliminate paraprotein interference.


Assuntos
Hiperfosfatemia , Mieloma Múltiplo , Humanos , Mieloma Múltiplo/complicações , Mieloma Múltiplo/diagnóstico , Hiperfosfatemia/diagnóstico , Paraproteínas , Fosfatos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA