Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Neural Eng ; 21(3)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38834060

RESUMO

Objective.The corticospinal responses of the motor network to transcranial magnetic stimulation (TMS) are highly variable. While often regarded as noise, this variability provides a way of probing dynamic brain states related to excitability. We aimed to uncover spontaneously occurring cortical states that alter corticospinal excitability.Approach.Electroencephalography (EEG) recorded during TMS registers fast neural dynamics-unfortunately, at the cost of anatomical precision. We employed analytic Common Spatial Patterns technique to derive excitability-related cortical activity from pre-TMS EEG signals while overcoming spatial specificity issues.Main results.High corticospinal excitability was predicted by alpha-band activity, localized adjacent to the stimulated left motor cortex, and suggesting a travelling wave-like phenomenon towards frontal regions. Low excitability was predicted by alpha-band activity localized in the medial parietal-occipital and frontal cortical regions.Significance.We established a data-driven approach for uncovering network-level neural activity that modulates TMS effects. It requires no prior anatomical assumptions, while being physiologically interpretable, and can be employed in both exploratory investigation and brain state-dependent stimulation.


Assuntos
Eletroencefalografia , Potencial Evocado Motor , Córtex Motor , Rede Nervosa , Tratos Piramidais , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Masculino , Tratos Piramidais/fisiologia , Adulto , Feminino , Córtex Motor/fisiologia , Eletroencefalografia/métodos , Rede Nervosa/fisiologia , Potencial Evocado Motor/fisiologia , Adulto Jovem , Ritmo alfa/fisiologia
2.
Biomedicines ; 12(5)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38790917

RESUMO

State-dependent non-invasive brain stimulation (NIBS) informed by electroencephalography (EEG) has contributed to the understanding of NIBS inter-subject and inter-session variability. While these approaches focus on local EEG characteristics, it is acknowledged that the brain exhibits an intrinsic long-range dynamic organization in networks. This proof-of-concept study explores whether EEG connectivity of the primary motor cortex (M1) in the pre-stimulation period aligns with the Motor Network (MN) and how the MN state affects responses to the transcranial magnetic stimulation (TMS) of M1. One thousand suprathreshold TMS pulses were delivered to the left M1 in eight subjects at rest, with simultaneous EEG. Motor-evoked potentials (MEPs) were measured from the right hand. The source space functional connectivity of the left M1 to the whole brain was assessed using the imaginary part of the phase locking value at the frequency of the sensorimotor µ-rhythm in a 1 s window before the pulse. Group-level connectivity revealed functional links between the left M1, left supplementary motor area, and right M1. Also, pulses delivered at high MN connectivity states result in a greater MEP amplitude compared to low connectivity states. At the single-subject level, this relation is more highly expressed in subjects that feature an overall high cortico-spinal excitability. In conclusion, this study paves the way for MN connectivity-based NIBS.

3.
Brain Topogr ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598019

RESUMO

Electroencephalogram (EEG) recorded as response to transcranial magnetic stimulation (TMS) can be highly informative of cortical reactivity and connectivity. Reliable EEG interpretation requires artifact removal as the TMS-evoked EEG can contain high-amplitude artifacts. Several methods have been proposed to uncover clean neuronal EEG responses. In practice, determining which method to select for different types of artifacts is often difficult. Here, we used a unified data cleaning framework based on beamforming to improve the algorithm selection and adaptation to the recorded signals. Beamforming properties are well understood, so they can be used to yield customized methods for EEG cleaning based on prior knowledge of the artifacts and the data. The beamforming implementations also cover, but are not limited to, the popular TMS-EEG cleaning methods: independent component analysis (ICA), signal-space projection (SSP), signal-space-projection-source-informed-reconstruction method (SSP-SIR), the source-estimate-utilizing noise-discarding algorithm (SOUND), data-driven Wiener filter (DDWiener), and the multiple-source approach. In addition to these established methods, beamforming provides a flexible way to derive novel artifact suppression algorithms by considering the properties of the recorded data. With simulated and measured TMS-EEG data, we show how to adapt the beamforming-based cleaning to different data and artifact types, namely TMS-evoked muscle artifacts, ocular artifacts, TMS-related peripheral responses, and channel noise. Importantly, beamforming implementations are fast to execute: We demonstrate how the SOUND algorithm becomes orders of magnitudes faster via beamforming. Overall, the beamforming-based spatial filtering framework can greatly enhance the selection, adaptability, and speed of EEG artifact removal.

4.
Front Bioeng Biotechnol ; 12: 1330330, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681960

RESUMO

Introduction: The primary constraint of non-invasive brain-machine interfaces (BMIs) in stroke rehabilitation lies in the poor spatial resolution of motor intention related neural activity capture. To address this limitation, hybrid brain-muscle-machine interfaces (hBMIs) have been suggested as superior alternatives. These hybrid interfaces incorporate supplementary input data from muscle signals to enhance the accuracy, smoothness and dexterity of rehabilitation device control. Nevertheless, determining the distribution of control between the brain and muscles is a complex task, particularly when applied to exoskeletons with multiple degrees of freedom (DoFs). Here we present a feasibility, usability and functionality study of a bio-inspired hybrid brain-muscle machine interface to continuously control an upper limb exoskeleton with 7 DoFs. Methods: The system implements a hierarchical control strategy that follows the biologically natural motor command pathway from the brain to the muscles. Additionally, it employs an innovative mirror myoelectric decoder, offering patients a reference model to assist them in relearning healthy muscle activation patterns during training. Furthermore, the multi-DoF exoskeleton enables the practice of coordinated arm and hand movements, which may facilitate the early use of the affected arm in daily life activities. In this pilot trial six chronic and severely paralyzed patients controlled the multi-DoF exoskeleton using their brain and muscle activity. The intervention consisted of 2 weeks of hBMI training of functional tasks with the system followed by physiotherapy. Patients' feedback was collected during and after the trial by means of several feedback questionnaires. Assessment sessions comprised clinical scales and neurophysiological measurements, conducted prior to, immediately following the intervention, and at a 2-week follow-up. Results: Patients' feedback indicates a great adoption of the technology and their confidence in its rehabilitation potential. Half of the patients showed improvements in their arm function and 83% improved their hand function. Furthermore, we found improved patterns of muscle activation as well as increased motor evoked potentials after the intervention. Discussion: This underscores the significant potential of bio-inspired interfaces that engage the entire nervous system, spanning from the brain to the muscles, for the rehabilitation of stroke patients, even those who are severely paralyzed and in the chronic phase.

5.
Biol Psychiatry ; 95(6): 545-552, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37743002

RESUMO

In the same way that beauty lies in the eye of the beholder, what a stimulus does to the brain is determined not simply by the nature of the stimulus but by the nature of the brain that is receiving the stimulus at that instant in time. Over the past decades, therapeutic brain stimulation has typically applied open-loop fixed protocols and has largely ignored this principle. Only recent neurotechnological advancements have enabled us to predict the nature of the brain (i.e., the electrophysiological brain state in the next instance in time) with sufficient temporal precision in the range of milliseconds using feedforward algorithms applied to electroencephalography time-series data. This allows stimulation exclusively whenever the targeted brain area is in a prespecified excitability or connectivity state. Preclinical studies have shown that repetitive stimulation during a particular brain state (e.g., high-excitability state), but not during other states, results in lasting modification (e.g., long-term potentiation) of the stimulated circuits. Here, we survey the evidence that this is also possible at the systems level of the human cortex using electroencephalography-informed transcranial magnetic stimulation. We critically discuss opportunities and difficulties in developing brain state-dependent stimulation for more effective long-term modification of pathological brain networks (e.g., in major depressive disorder) than is achievable with conventional fixed protocols. The same real-time electroencephalography-informed transcranial magnetic stimulation technology will allow closing of the loop by recording the effects of stimulation. This information may enable stimulation protocol adaptation that maximizes treatment response. This way, brain states control brain stimulation, thereby introducing a paradigm shift from open-loop to closed-loop stimulation.


Assuntos
Transtorno Depressivo Maior , Humanos , Encéfalo/fisiologia , Estimulação Magnética Transcraniana/métodos , Eletroencefalografia , Potenciação de Longa Duração
6.
Neuroimage ; 284: 120427, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38008297

RESUMO

We tested previous post-hoc findings indicating a relationship between functional connectivity (FC) in the motor network and corticospinal excitability (CsE), in a real-time EEG-TMS experiment in healthy participants. We hypothesized that high FC between left and right motor cortex predicts high CsE. FC was quantified in real-time by single-trial phase-locking value (stPLV), and TMS single pulses were delivered based on the current FC. CsE was indexed by motor-evoked potential (MEP) amplitude in a hand muscle. Possible confounding factors (pre-stimulus µ-power and phase, interstimulus interval) were evaluated post hoc. MEPs were significantly larger during high FC compared to low FC. Post hoc analysis revealed that the FC condition showed a significant interaction with µ-power in the stimulated hemisphere. Further, inter-stimulus interval (ISI) interacted with high vs. low FC conditions. In summary, FC was confirmed to be predictive of CsE, but should not be considered in isolation from µ-power and ISI. Moreover, FC was complementary to µ-phase in predicting CsE. Motor network FC is another marker of real-time accessible CsE beyond previously established markers, in particular phase and power of the µ rhythm, and may help define a more robust composite biomarker of high/low excitability states of human motor cortex.


Assuntos
Córtex Motor , Humanos , Córtex Motor/fisiologia , Eletroencefalografia , Estimulação Magnética Transcraniana , Músculo Esquelético/fisiologia , Potencial Evocado Motor/fisiologia
7.
J Neuroeng Rehabil ; 20(1): 150, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37941036

RESUMO

BACKGROUND: Previous studies showed that repetitive transcranial magnetic stimulation (rTMS) reduces spasticity after stroke. However, clinical assessments like the modified Ashworth scale, cannot discriminate stretch reflex-mediated stiffness (spasticity) from passive stiffness components of resistance to muscle stretch. The mechanisms through which rTMS might influence spasticity are also not understood. METHODS: We measured the effects of contralesional motor cortex 1 Hz rTMS (1200 pulses + 50 min physiotherapy: 3×/week, for 4-6 weeks) on spasticity of the wrist flexor muscles in 54 chronic stroke patients using a hand-held dynamometer for objective quantification of the stretch reflex response. In addition, we measured the excitability of three spinal mechanisms thought to be related to post-stroke spasticity: post-activation depression, presynaptic inhibition and reciprocal inhibition before and after the intervention. Effects on motor impairment and function were also assessed using standardized stroke-specific clinical scales. RESULTS: The stretch reflex-mediated torque in the wrist flexors was significantly reduced after the intervention, while no change was detected in the passive stiffness. Additionally, there was a significant improvement in the clinical tests of motor impairment and function. There were no significant changes in the excitability of any of the measured spinal mechanisms. CONCLUSIONS: We demonstrated that contralesional motor cortex 1 Hz rTMS and physiotherapy can reduce the stretch reflex-mediated component of resistance to muscle stretch without affecting passive stiffness in chronic stroke. The specific physiological mechanisms driving this spasticity reduction remain unresolved, as no changes were observed in the excitability of the investigated spinal mechanisms.


Assuntos
Córtex Motor , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Estimulação Magnética Transcraniana , Acidente Vascular Cerebral/complicações , Espasticidade Muscular/etiologia , Modalidades de Fisioterapia
8.
PLoS One ; 18(10): e0293546, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37903116

RESUMO

Phase-dependent plasticity has been proposed as a neurobiological mechanism by which oscillatory phase-amplitude cross-frequency coupling mediates memory process in the brain. Mimicking this mechanism, real-time EEG oscillatory phase-triggered transcranial magnetic stimulation (TMS) has successfully induced LTP-like changes in corticospinal excitability in the human motor cortex. Here we asked whether EEG phase-triggered afferent stimulation alone, if repetitively applied to the peaks, troughs, or random phases of the sensorimotor mu-alpha rhythm, would be sufficient to modulate the strength of thalamocortical synapses as assessed by changes in somatosensory evoked potential (SEP) N20 and P25 amplitudes and sensory thresholds (ST). Specifically, we applied 100 Hz triplets of peripheral electrical stimulation (PES) to the thumb, middle, and little finger of the right hand in pseudorandomized trials, with the afferent input from each finger repetitively and consistently arriving either during the cortical mu-alpha trough or peak or at random phases. No significant changes in SEP amplitudes or ST were observed across the phase-dependent PES intervention. We discuss potential limitations of the study and argue that suboptimal stimulation parameter choices rather than a general lack of phase-dependent plasticity in thalamocortical synapses are responsible for this null finding. Future studies should further explore the possibility of phase-dependent sensory stimulation.


Assuntos
Potencial Evocado Motor , Córtex Motor , Humanos , Potencial Evocado Motor/fisiologia , Potenciais Somatossensoriais Evocados , Córtex Motor/fisiologia , Ritmo alfa , Estimulação Magnética Transcraniana , Limiar Sensorial , Estimulação Elétrica , Córtex Somatossensorial/fisiologia
9.
Front Neural Circuits ; 17: 1208930, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37671039

RESUMO

Symptom provocation is a well-established component of psychiatric research and therapy. It is hypothesized that specific activation of those brain circuits involved in the symptomatic expression of a brain pathology makes the relevant neural substrate accessible as a target for therapeutic interventions. For example, in the treatment of obsessive-compulsive disorder (OCD), symptom provocation is an important part of psychotherapy and is also performed prior to therapeutic brain stimulation with transcranial magnetic stimulation (TMS). Here, we discuss the potential of symptom provocation to isolate neurophysiological biomarkers reflecting the fluctuating activity of relevant brain networks with the goal of subsequently using these markers as targets to guide therapy. We put forward a general experimental framework based on the rapid switching between psychiatric symptom states. This enable neurophysiological measures to be derived from EEG and/or TMS-evoked EEG measures of brain activity during both states. By subtracting the data recorded during the baseline state from that recorded during the provoked state, the resulting contrast would ideally isolate the specific neural circuits differentially activated during the expression of symptoms. A similar approach enables the design of effective classifiers of brain activity from EEG data in Brain-Computer Interfaces (BCI). To obtain reliable contrast data, psychiatric state switching needs to be achieved multiple times during a continuous recording so that slow changes of brain activity affect both conditions equally. This is achieved easily for conditions that can be controlled intentionally, such as motor imagery, attention, or memory retention. With regard to psychiatric symptoms, an increase can often be provoked effectively relatively easily, however, it can be difficult to reliably and rapidly return to a baseline state. Here, we review different approaches to return from a provoked state to a baseline state and how these may be applied to different symptoms occurring in different psychiatric disorders.


Assuntos
Interfaces Cérebro-Computador , Psiquiatria , Humanos , Estimulação Magnética Transcraniana , Encéfalo , Eletroencefalografia
10.
Alzheimers Res Ther ; 15(1): 133, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37550778

RESUMO

BACKGROUND: Alzheimer's dementia (AD) is associated with electroencephalography (EEG) abnormalities including in the power ratio of beta to theta frequencies. EEG studies in mild cognitive impairment (MCI) have been less consistent in identifying such abnormalities. One potential reason is not excluding the EEG aperiodic components, which are less associated with cognition than the periodic components. Here, we investigate whether aperiodic and periodic EEG components are disrupted differently in AD or MCI vs. healthy control (HC) individuals and whether a periodic based beta/theta ratio differentiates better MCI from AD and HC groups than a ratio based on the full spectrum. METHODS: Data were collected from 44 HC (mean age (SD) = 69.1 (5.3)), 114 MCI (mean age (SD) = 72.2 (7.5)), and 41 AD (mean age (SD) = 75.7 (6.5)) participants. Aperiodic and periodic components and full spectrum EEG were compared among the three groups. Receiver operating characteristic curves obtained via logistic regression classifications were used to distinguish the groups. Last, we explored the relationships between cognitive performance and the beta/theta ratios based on the full or periodic spectrum. RESULTS: Aperiodic EEG components did not differ among the three groups. In contrast, AD participants showed an increase in full spectrum and periodic relative powers for delta, theta, and gamma and a decrease for beta when compared to HC or MCI participants. As predicted, MCI group differed from HC participants on the periodic based beta/theta ratio (Bonferroni corrected p-value = 0.036) measured over the occipital region. Classifiers based on beta/theta power ratio in EEG periodic components distinguished AD from HC and MCI participants, and outperformed classifiers based on beta/theta power ratio in full spectrum EEG. Beta/theta ratios were comparable in their association with cognition. CONCLUSIONS: In contrast to a full spectrum EEG analysis, a periodic-based analysis shows that MCI individuals are different on beta/theta ratio when compared to healthy individuals. Focusing on periodic components in EEG studies with or without other biological markers of neurodegenerative diseases could result in more reliable findings to separate MCI from healthy aging, which would be valuable for designing preventative interventions.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Humanos , Doença de Alzheimer/complicações , Eletroencefalografia , Disfunção Cognitiva/psicologia , Cognição , Biomarcadores
11.
BMC Neurol ; 23(1): 204, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37231390

RESUMO

BACKGROUND: Stroke is a major cause of death and the most frequent cause of permanent disability in western countries. Repetitive transcranial brain stimulation (rTMS) has been used to enhance neuronal plasticity after stroke, yet with only moderate effect sizes. Here we will apply a highly innovative technology that synchronizes rTMS to specific brain states identified by real-time analysis of electroencephalography. METHODS: One hundred forty-four patients with early subacute ischemic motor stroke will be included in a multicenter 3-arm parallel, randomized, double-blind, standard rTMS and sham rTMS-controlled exploratory trial in Germany. In the experimental condition, rTMS will be synchronized to the trough of the sensorimotor µ-oscillation, a high-excitability state, over ipsilesional motor cortex. In the standard rTMS control condition the identical protocol will be applied, but non-synchronized to the ongoing µ-oscillation. In the sham condition, the same µ-oscillation-synchronized protocol as in experimental condition will be applied, but with ineffective rTMS, using the sham side of an active/placebo TMS coil. The treatment will be performed over five consecutive work days (1,200 pulses per day, 6,000 pulses total). The primary endpoint will be motor performance after the last treatment session as measured by the Fugl-Meyer Assessment Upper Extremity. DISCUSSION: This study investigates, for the first time, the therapeutic efficacy of personalized, brain-state-dependent rTMS. We hypothesize that synchronization of rTMS with a high-excitability state will lead to significantly stronger improvement of paretic upper extremity motor function than standard or sham rTMS. Positive results may catalyze a paradigm-shift towards personalized brain-state-dependent stimulation therapies. TRIAL REGISTRATION: This study was registered at ClinicalTrials.gov (NCT05600374) on 10-21-2022.


Assuntos
AVC Isquêmico , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Estimulação Magnética Transcraniana/métodos , Reabilitação do Acidente Vascular Cerebral/métodos , Resultado do Tratamento , Acidente Vascular Cerebral/terapia , Encéfalo , Método Duplo-Cego , Recuperação de Função Fisiológica/fisiologia
12.
Sci Rep ; 13(1): 6796, 2023 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-37100795

RESUMO

Combined transcranial magnetic stimulation and electroencephalography (TMS-EEG) is an effective way to evaluate neurophysiological processes at the level of the cortex. To further characterize the TMS-evoked potential (TEP) generated with TMS-EEG, beyond the motor cortex, we aimed to distinguish between cortical reactivity to TMS versus non-specific somatosensory and auditory co-activations using both single-pulse and paired-pulse protocols at suprathreshold stimulation intensities over the left dorsolateral prefrontal cortex (DLPFC). Fifteen right-handed healthy participants received six blocks of stimulation including single and paired TMS delivered as active-masked (i.e., TMS-EEG with auditory masking and foam spacing), active-unmasked (TMS-EEG without auditory masking and foam spacing) and sham (sham TMS coil). We evaluated cortical excitability following single-pulse TMS, and cortical inhibition following a paired-pulse paradigm (long-interval cortical inhibition (LICI)). Repeated measure ANOVAs revealed significant differences in mean cortical evoked activity (CEA) of active-masked, active-unmasked, and sham conditions for both the single-pulse (F(1.76, 24.63) = 21.88, p < 0.001, η2 = 0.61) and LICI (F(1.68, 23.49) = 10.09, p < 0.001, η2 = 0.42) protocols. Furthermore, global mean field amplitude (GMFA) differed significantly across the three conditions for both single-pulse (F(1.85, 25.89) = 24.68, p < 0.001, η2 = 0.64) and LICI (F(1.8, 25.16) = 14.29, p < 0.001, η2 = 0.5). Finally, only active LICI protocols but not sham stimulation ([active-masked (0.78 ± 0.16, P < 0.0001)], [active-unmasked (0.83 ± 0.25, P < 0.01)]) resulted in significant signal inhibition. While previous findings of a significant somatosensory and auditory contribution to the evoked EEG signal are replicated by our study, an artifact attenuated cortical reactivity can reliably be measured in the TMS-EEG signal with suprathreshold stimulation of DLPFC. Artifact attenuation can be accomplished using standard procedures, and even when masked, the level of cortical reactivity is still far above what is produced by sham stimulation. Our study illustrates that TMS-EEG of DLPFC remains a valid investigational tool.


Assuntos
Artefatos , Córtex Pré-Frontal Dorsolateral , Humanos , Eletroencefalografia/métodos , Potenciais Evocados/fisiologia , Estimulação Magnética Transcraniana/métodos , Potencial Evocado Motor/fisiologia
13.
Virtual Real ; 27(1): 347-369, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36915631

RESUMO

Virtual reality (VR)-based motor therapy is an emerging approach in neurorehabilitation. The combination of VR with electroencephalography (EEG) presents further opportunities to improve therapeutic efficacy by personalizing the paradigm. Specifically, the idea is to synchronize the choice and timing of stimuli in the perceived virtual world with fluctuating brain states relevant to motor behavior. Here, we present an open source EEG single-trial based classification pipeline that is designed to identify ongoing brain states predictive of the planning and execution of movements. 9 healthy volunteers each performed 1080 trials of a repetitive reaching task with an implicit two-alternative forced choice, i.e., use of the right or left hand, in response to the appearance of a visual target. The performance of the EEG decoding pipeline was assessed with respect to classification accuracy of right vs. left arm use, based on the EEG signal at the time of the stimulus. Different features, feature extraction methods, and classifiers were compared at different time windows; the number and location of informative EEG channels and the number of calibration trials needed were also quantified, as well as any benefits from individual-level optimization of pipeline parameters. This resulted in a set of recommended parameters that achieved an average 83.3% correct prediction on never-before-seen testing data, and a state-of-the-art 77.1% in a real-time simulation. Neurophysiological plausibility of the resulting classifiers was assessed by time-frequency and event-related potential analyses, as well as by Independent Component Analysis topographies and cortical source localization. We expect that this pipeline will facilitate the identification of relevant brain states as prospective therapeutic targets in closed-loop EEG-VR motor neurorehabilitation.

14.
Biosensors (Basel) ; 13(2)2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36831986

RESUMO

The cortical response to transcranial magnetic stimulation (TMS) has notable inter-trial variability. One source of this variability can be the influence of the phase and power of pre-stimulus neuronal oscillations on single-trial TMS responses. Here, we investigate the effect of brain oscillatory activity on TMS response in 49 distinct healthy participants (64 datasets) who had received single-pulse TMS over the left dorsolateral prefrontal cortex. Across all frequency bands of theta (4-7 Hz), alpha (8-13 Hz), and beta (14-30 Hz), there was no significant effect of pre-TMS phase on single-trial cortical evoked activity. After high-powered oscillations, whether followed by a TMS pulse or not, the subsequent activity was larger than after low-powered oscillations. We further defined a measure, corrected_effect, to enable us to investigate brain responses to the TMS pulse disentangled from the power of ongoing (spontaneous) oscillations. The corrected_effect was significantly different from zero (meaningful added effect of TMS) only in theta and beta bands. Our results suggest that brain state prior to stimulation might play some role in shaping the subsequent TMS-EEG response. Specifically, our findings indicate that the power of ongoing oscillatory activity, but not phase, can influence brain responses to TMS. Aligning the TMS pulse with specific power thresholds of an EEG signal might therefore reduce variability in neurophysiological measurements and also has the potential to facilitate more robust therapeutic effects of stimulation.


Assuntos
Excitabilidade Cortical , Estimulação Magnética Transcraniana , Humanos , Encéfalo , Eletroencefalografia/métodos , Estimulação Magnética Transcraniana/métodos
15.
Brain Stimul ; 16(2): 567-593, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36828303

RESUMO

Transcranial magnetic stimulation (TMS) evokes neuronal activity in the targeted cortex and connected brain regions. The evoked brain response can be measured with electroencephalography (EEG). TMS combined with simultaneous EEG (TMS-EEG) is widely used for studying cortical reactivity and connectivity at high spatiotemporal resolution. Methodologically, the combination of TMS with EEG is challenging, and there are many open questions in the field. Different TMS-EEG equipment and approaches for data collection and analysis are used. The lack of standardization may affect reproducibility and limit the comparability of results produced in different research laboratories. In addition, there is controversy about the extent to which auditory and somatosensory inputs contribute to transcranially evoked EEG. This review provides a guide for researchers who wish to use TMS-EEG to study the reactivity of the human cortex. A worldwide panel of experts working on TMS-EEG covered all aspects that should be considered in TMS-EEG experiments, providing methodological recommendations (when possible) for effective TMS-EEG recordings and analysis. The panel identified and discussed the challenges of the technique, particularly regarding recording procedures, artifact correction, analysis, and interpretation of the transcranial evoked potentials (TEPs). Therefore, this work offers an extensive overview of TMS-EEG methodology and thus may promote standardization of experimental and computational procedures across groups.


Assuntos
Eletroencefalografia , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Reprodutibilidade dos Testes , Eletroencefalografia/métodos , Potenciais Evocados/fisiologia , Coleta de Dados
16.
Neuroimage ; 266: 119805, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36513289

RESUMO

Alpha oscillations are thought to reflect alternating cortical states of excitation and inhibition. Studies of perceptual thresholds and evoked potentials have shown the scalp EEG negative phase of the oscillation to correspond to a short-lasting low-threshold and high-excitability state of underlying visual, somatosensory, and primary motor cortex. The negative peak of the oscillation is assumed to correspond to the state of highest excitability based on biophysical considerations and considerable effort has been made to improve the extraction of a predictive signal by individually optimizing EEG montages. Here, we investigate whether it is the negative peak of sensorimotor µ-rhythm that corresponds to the highest corticospinal excitability, and whether this is consistent between individuals. In 52 adult participants, a standard 5-channel surface Laplacian EEG montage was used to extract sensorimotor µ-rhythm during transcranial magnetic stimulation (TMS) of primary motor cortex. Post-hoc trials were sorted from 800 TMS-evoked motor potentials (MEPs) according to the pre-stimulus EEG (estimated instantaneous phase) and MEP amplitude (as an index of corticospinal excitability). Different preprocessing transformations designed to improve the accuracy by which µ-alpha phase predicts excitability were also tested. By fitting a sinusoid to the MEP amplitudes, sorted according to pre-stimulus EEG-phase, we found that excitability was highest during the early rising phase, at a significant delay with respect to the negative peak by on average 45° or 10 ms. The individual phase of highest excitability was consistent across study participants and unaffected by two different EEG-cleaning methods that utilize 64 channels to improve signal quality by compensating for individual noise level and channel covariance. Personalized transformations of the montage did not yield better prediction of excitability from µ-alpha phase. The relationship between instantaneous phase of a brain oscillation and fluctuating cortical excitability appears to be more complex than previously hypothesized. In TMS of motor cortex, a standard surface Laplacian 5-channel EEG montage is effective in extracting a predictive signal and the phase corresponding to the highest excitability appears to be consistent between individuals. This is an encouraging result with respect to the clinical potential of therapeutic personalized brain interventions in the motor system. However, it remains to be investigated, whether similar results can be obtained for other brain areas and brain oscillations targeted with EEG and TMS.


Assuntos
Excitabilidade Cortical , Córtex Motor , Adulto , Humanos , Potencial Evocado Motor/fisiologia , Eletroencefalografia/métodos , Córtex Motor/fisiologia , Estimulação Magnética Transcraniana/métodos , Excitabilidade Cortical/fisiologia
18.
NPJ Parkinsons Dis ; 8(1): 161, 2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36424411

RESUMO

Whilst involvement of the motor cortex in the phenomenon of freezing in Parkinson's disease has been previously suggested, few empiric studies have been conducted to date. We investigated motor cortex (M1) excitability in eleven right-handed Parkinson's disease patients (aged 69.7 ± 9.6 years, disease duration 11.2 ± 3.9 years, akinesia-rigidity type) with verified gait freezing using a single-pulse transcranial magnetic stimulation (TMS) repetitive finger tapping paradigm. We delivered single TMS pulses at 120% of the active motor threshold at the 'ascending (contraction)' and 'descending (relaxation)' slope of the tap cycle during i) regular tapping, ii) the transition period of the three taps prior to a freeze and iii) during freezing of upper limb movement. M1 excitability was modulated along the tap cycle with greater motor evoked potentials (MEPs) during 'ascending' than 'descending'. Furthermore, MEPs during the 'ascending' phase of regular tapping, but not during the transition period, were greater compared to the MEPs recorded throughout a freeze. Neither force nor EMG activity 10-110 s before the stimulus predicted MEP size. This piloting study suggests that M1 excitability is reduced during freezing and the transition period preceding a freeze. This supports that M1 excitability is critical to freezing in Parkinson's disease.

19.
J Neurosci Methods ; 379: 109662, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35803405

RESUMO

BACKGROUND: Sensorimotor µ-rhythm phase is correlated with corticospinal excitability. Transcranial magnetic stimulation (TMS) of motor cortex results in larger motor evoked potentials (MEPs) during the negative peak of the EEG oscillation as extracted with a surface Laplacian. However, the anatomical source of the relevant oscillation is not clear and demonstration of the relationship is sensitive to the choice of EEG montage. OBJECTIVE/HYPOTHESIS: Here, we compared two EEG montages preferentially sensitive to oscillations originating from the crown of precentral gyrus (dorsal premotor cortex) vs. postcentral gyrus (secondary somatosensory cortex). We hypothesized that the EEG signal from precentral gyrus would correlate more strongly with MEP amplitude, given that the corticospinal neurons are located in the anterior wall of the sulcus and the corticospinal tract has input from premotor cortex. NEW METHOD: Real-time EEG-triggered TMS of motor cortex was applied in 6 different conditions in randomly interleaved order, 3 phase conditions (positive peak, negative peak, random phase of the ongoing µ-oscillation), and each phase condition for 2 different EEG montages corresponding to oscillations preferentially originating in precentral gyrus (premotor cortex) vs. postcentral gyrus (somatosensory cortex), extracted using FCC3h vs. C3 centered EEG montages. RESULTS: The negative vs. positive peak of sensorimotor µ-rhythm as extracted from the C3 montage (postcentral gyrus, somatosensory cortex) correlated with states of high vs. low corticospinal excitability (p < 0.001), replicating previous findings. However, no significant correlation was found for sensorimotor µ-rhythm as extracted from the neighboring FCC3 montage (precentral gyrus, premotor cortex). This implies that EEG-signals from the somatosensory cortex are better predictors of corticospinal excitability than EEG-signals from the motor areas. CONCLUSIONS: The extraction of a brain oscillation whose phase corresponds to corticospinal excitability is highly sensitive to the selected EEG montage and the location of the EEG sensors on the scalp. Here, the cortical source of EEG oscillations predicting response amplitude does not correspond to the cortical target of the stimulation, indicating that even in this simple case, a specific neuronal pathway from somatosensory cortex to primary motor cortex is involved.


Assuntos
Córtex Motor , Eletroencefalografia/métodos , Potencial Evocado Motor/fisiologia , Córtex Motor/fisiologia , Tratos Piramidais/fisiologia , Estimulação Magnética Transcraniana/métodos
20.
J Neurosci Methods ; 376: 109591, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35421514

RESUMO

Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) is a technique for studying cortical excitability and connectivity in health and disease, allowing basic research and potential clinical applications. A major methodological issue, severely limiting the applicability of TMS-EEG, relates to the contamination of EEG signals by artifacts of biologic or non-biologic origin. To solve this problem, several methods, based on independent component analysis (ICA), principal component analysis (PCA), signal space projection (SSP), and other approaches, have been developed over the last decade. This article is divided into two parts. In the first part, we review the theoretical background of the currently available TMS-EEG artifact removal methods. In the second part, we formally introduce the mathematics underpinnings of the cleaning methods. We classify them into spatial and temporal filters based on their properties. Since the most frequently used TMS-EEG cleaning approach are spatial filter methods, we focus on them and introduce beamforming as a unified framework of the most popular spatial filtering techniques. This unifying approach enables the comparative assessment of these methods by highlighting their differences in terms of assumptions, challenges, and applicability for different types of artifacts and data. The different properties and challenges of the methods discussed are illustrated with both simulated and recorded data. This article targets non-mathematical and mathematical audiences. Accordingly, those readers interested in essential background information on these methods can focus on Section 2. Whereas theory-oriented readers may find Section 3 helpful for making informed decisions between existing methods and developing the methodology further.


Assuntos
Artefatos , Estimulação Magnética Transcraniana , Eletroencefalografia/métodos , Análise de Componente Principal , Estimulação Magnética Transcraniana/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA