Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 133(3): 1269-80, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23464000

RESUMO

Clear air turbulence (CAT) is the leading cause of in-flight injuries and in severe cases can result in fatalities. The purpose of this work is to design and develop an infrasonic array network for early warning of clear air turbulence. The infrasonic system consists of an infrasonic three-microphone array, compact windscreens, and data management system. Past experimental efforts to detect acoustic emissions from CAT have been limited. An array of three infrasonic microphones, operating in the field at NASA Langley Research Center, on several occasions received signals interpreted as infrasonic emissions from CAT. Following comparison with current lidar and other past methods, the principle of operation, the experimental methods, and experimental data are presented for case studies and confirmed by pilot reports. The power spectral density of the received signals was found to fit a power law having an exponent of -6 to -7, which is found to be characteristics of infrasonic emissions from CAT, in contrast to findings of the past.


Assuntos
Acústica , Pressão Atmosférica , Som , Vento , Acústica/instrumentação , Aviação , Desenho de Equipamento , Movimento (Física) , Espalhamento de Radiação , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Voo Espacial , Fatores de Tempo , Transdutores de Pressão
2.
Comput Methods Programs Biomed ; 108(1): 20-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22285458

RESUMO

A dual transmission model of the fetal heart sounds is presented in which the properties of the signals received on a sensor, installed on the maternal abdominal surface, depend upon the position of the fetus. For a fetus in the occiput anterior position, the predominant spectral content lies in the frequency band 16-50Hz ("impact" mode), but for a fetus in the occiput posterior position, it lies in the frequency band 80-110Hz ("acoustic" mode). Signal processing comprises digital bandpass filtering, matched filtering, Teager energy operator, autocorrelation, and figure of merit algorithms. The digital filter permits the user to select the frequency band that best conforms to the prevailing signal mode. Clinical tests on twelve patients, with some in the occiput anterior and some in the occiput posterior fetal positions, support the validity of the dual transmission model.


Assuntos
Monitorização Fetal/métodos , Coração/embriologia , Humanos , Processamento de Sinais Assistido por Computador
3.
J Acoust Soc Am ; 127(6): 3327-34, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20550233

RESUMO

The principle of the compact nonporous windscreen is based on the great penetrability of infrasound through matter. The windscreen performance is characterized by the ratio of the sound pressure at an interior microphone, located in the center of a windscreen, to the incident sound pressure in the free field. The frequency dependence of this pressure ratio is derived as a function of the windscreen material and geometric properties. Four different windscreen geometries are considered: a subsurface, box-shaped windscreen, a cylindrical windscreen of infinite length, a cylindrical windscreen of finite length, and a spherical windscreen. Results are presented for windscreens made of closed-cell polyurethane foam and for typical dimensions of each of the above geometries. The cylindrical windscreen of finite length, featuring evanescent radial modes, behaves as a unity-gain, low-pass filter, cutting off sharply at the end of the infrasonic range. The remaining geometries reveal a pass band that extends well into the audio range, terminated by a pronounced peak beyond which the response plummets rapidly.

4.
J Acoust Soc Am ; 126(3): 1107-10, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19739723

RESUMO

Crosstalk in electrostatic actuator calibrations is defined as the ratio of the microphone response to the actuator excitation voltage at a given frequency with the actuator polarization voltage turned off to the response, at the excitation frequency, with the polarization voltage turned on. It consequently contributes to the uncertainty of electrostatic actuator calibrations. Two sources of crosstalk are analyzed: the first attributed to the stray capacitance between the actuator electrode and the microphone backplate, and the second to the ground resistance appearing as a common element in the actuator excitation and microphone input loops. Measurements conducted on 1/4, 1/2, and 1 in. air condenser microphones reveal that the crosstalk has no frequency dependence up to the membrane resonance frequency and that the level of crosstalk lies at about -60 dB for all three microphones-conclusions that are consistent with theory. The measurements support the stray capacitance model. The contribution of crosstalk to the measurement standard uncertainty of an electrostatic actuator calibration is therewith 0.01 dB.

5.
J Acoust Soc Am ; 119(1): 320-9, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16454287

RESUMO

A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that can plague FF measurements. Calibrations were performed on 1/4-in. FF air-condenser, electret, and microelectromechanical systems (MEMS) microphones in an anechoic chamber. The uncertainty of this FF method is estimated by comparing the pressure sensitivity of an air-condenser FF microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration. The root-mean-square difference is found to be +/- 0.3 dB over the range 1-80 kHz, and the combined standard uncertainty of the FF method, including other significant contributions, is +/- 0.41 dB.

6.
J Acoust Soc Am ; 113(6): 3179-87, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12822790

RESUMO

Background noise studies have been extended from air condenser microphones to piezoresistive, electret condenser, and ceramic microphones. Theoretical models of the respective noise sources within each microphone are developed and are used to derive analytical expressions for the noise power spectral density for each type. Several additional noise sources for the piezoresistive and electret microphones, beyond what had previously been considered, were applied to the models and were found to contribute significantly to the total noise power spectral density. Experimental background noise measurements were taken using an upgraded acoustic isolation vessel and data acquisition system, and the results were compared to the theoretically obtained expressions. The models were found to yield power spectral densities consistent with the experimental results. The measurements reveal that the 1/f noise coefficient is strongly correlated with the diaphragm damping resistance, irrespective of the detection technology, i.e., air condenser, piezoresistive, etc. This conclusion has profound implications upon the expected 1/f noise component of micromachined (MEMS) microphones.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA