Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Immunol ; 14: 1202630, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942335

RESUMO

Introduction: The humoral response after SARS-CoV-2 vaccination and boosters in kidney transplant recipients (KTRs) is heterogeneous and depends on immunosuppression status. There is no validated immune measurement associated with serological response in clinical practice. Multicolor flow cytometric immunophenotyping could be useful for measuring immune response. This study aimed to study B- and T-cell compartments through Standardized EuroFlow PID Orientation after SARS-CoV-2 vaccination and their association with IgG SARS-CoV-2 seropositivity status after two doses or boosters. Methods: We conducted a multicenter prospective study to evaluate humoral response after SARS-CoV-2 vaccination in KTRs. Heterologous regimen: two doses of inactivated SARS-CoV-2 and two boosters of BNT162b2 mRNA (n=75). Homologous vaccination: two doses of BNT162b2 mRNA and one BNT162b2 mRNA booster (n=13). Booster doses were administrated to KTRs without taking into account their IgG SARS-CoV-2 seropositivity status. Peripheral blood samples were collected 30 days after the second dose and after the last heterologous or homologous booster. A standardized EuroFlow PID Orientation Tube (PIDOT) and a supervised automated analysis were used for immune monitoring cellular subsets after boosters. Results: A total of 88 KTRs were included and divided into three groups according to the time of the first detected IgG SARS-CoV-2 seropositivity: non-responders (NRs, n=23), booster responders (BRs, n=41), and two-dose responders (2DRs, n=24). The NR group was more frequent on mycophenolate than the responder groups (NRs, 96%; BRs, 80%; 2DRs, 42%; p=0.000). Switched memory B cells in the 2DR group were higher than those in the BR and NR groups (medians of 30, 17, and 10 cells/ul, respectively; p=0.017). Additionally, the absolute count of central memory/terminal memory CD8 T cells was higher in the 2DR group than in the BR and NR groups. (166, 98, and 93 cells/ul, respectively; p=0.041). The rest of the T-cell populations studied did not show a statistical difference. Conclusion: switched memory B cells and memory CD8 T-cell populations in peripheral blood were associated with the magnitude of the humoral response after SARS-CoV-2 vaccination. Boosters increased IgG anti-SARS-CoV-2 levels, CM/TM CD8 T cells, and switched MBCs in patients with seropositivity after two doses. Interestingly, no seropositivity after boosters was associated with the use of mycophenolate and a lower number of switched MBCs and CM/TM CD8 T cells in peripheral blood.


Assuntos
COVID-19 , Transplante de Rim , Humanos , Vacinas contra COVID-19 , Vacina BNT162 , Células B de Memória , Estudos Prospectivos , COVID-19/prevenção & controle , SARS-CoV-2 , Imunossupressores/uso terapêutico , RNA Mensageiro , Imunoglobulina G
3.
Clin Kidney J ; 15(3): 527-533, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35198159

RESUMO

BACKGROUND: Antibody response against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) after mRNA or adenoviral vector-based vaccines is weak in kidney transplant (KT) patients. However, few studies have focused on humoral response after inactivated virus-based vaccines in KT. Here, we compare antibody response following vaccination with inactivated virus (CoronaVac®) and BNT162b2 mRNA. METHODS: A national multicentre cross-sectional study was conducted. The study group was composed of patients from all KT centres in Uruguay, vaccinated between 1 and 31 May 2021 (CoronaVac®, n = 245 and BNT162b2, n = 39). The control group was constituted of 82 healthy individuals. Participants had no prior confirmed coronavirus disease 2019 (COVID-19) test. Blood samples were collected between 30 and 40 days after the second dose. Serum-specific immunoglobulin G (IgG) antibodies against the receptor-binding domain (RBD) of SARS-CoV-2 Spike protein were determined using the COVID-19 IgG QUANT ELISA Kit. RESULTS: Only 29% of KT recipients showed seroconversion (36.5% BNT162b2, 27.8% inactivated virus, P = 0.248) in comparison with 100% in healthy control with either vaccine. Antibody levels against RBD were higher with BNT162b mRNA than with inactivated virus [median (interquartile range) 173 (73-554) and 29 (11-70) binding antibody units (BAU)/mL, P < 0.034] in KT and 10 times lower than healthy control [inactivated virus: 308 (209-335) and BNT162b2: 2638 (2608-3808) BAU/mL, P < 0.034]. In multivariate analysis, variables associated with negative humoral response were age, triple immunosuppression, estimated glomerular filtration rate and time post-KT. CONCLUSION: Seroconversion was low in KT patients after vaccination with both platforms. Antibody levels against SARS-CoV-2 were lower with inactivated virus than BNT162b mRNA. These findings support the need for strategies to improve immunogenicity in KT recipients after two doses of either vaccine.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA