Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Abdom Radiol (NY) ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38900326

RESUMO

BACKGROUND AND AIMS: The placement of Transjugular intrahepatic portosystemic shunt (TIPS) results in a sudden increase in central circulating blood volume, which requires proper regulation of the cardiovascular system. We aimed to investigate the impact of TIPS on cirrhotic cardiomyopathy (CCM). METHOD: A consecutive case series of patients with cirrhosis who underwent TIPS were evaluated by echocardiography and pressure measurements before, immediately after TIPS and 2-4 days later (delayed). Furthermore, all patients underwent a one-year follow-up. RESULTS: In this study, 107 patients were enrolled, 38 (35.5%) with CCM. Echocardiography revealed an increase in postoperative left ventricular filling pressure accompanied by an elevation in left ventricular ejection fraction (LVEF). However, patients in the CCM group exhibited lower LVEF and mean arterial pressure (MAP) compared to the non-CCM group. Post-TIPS, CCM patients showed increased right atrium pressure (RAP) that normalized within 2-4 days, whereas non-CCM patients had lower RAP than baseline. Compared to patient without CCM, CCM patients revealed lower immediate (16.7 ± 4.4 vs. 18.9 ± 4.8, p = 0.022) and delayed 15.9 ± 3.7 vs. 17.7 ± 5.3, p = 0.044) portal vein pressures (PVP) and portal pressure gradients (PPG) (7.7 ± 3.4 vs. 9.2 ± 3.6, p = 0.032 and 10.1 ± 3.1 vs. 12.3 ± 4.9, p = 0.013). The 1-year mortality rates were 13.2% for CCM patients and 4.3% for non-CCM patients (log-rank test, p = 0.093), with MELD score, and preoperative RAP significantly associated with the mortality. CONCLUSION: Cirrhotic patients with CCM exhibit lower PVP and PPG immediately after TIPS and 2-4 days later, without significantly impacting one-year survival outcomes.

3.
Quant Imaging Med Surg ; 14(1): 160-178, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223056

RESUMO

Background: The 2-dimensional proximal isovelocity surface area (2D PISA) method underestimates tricuspid regurgitation (TR) severity. Previously proposed correction algorithms should be further scrutinized. Methods: Two correction algorithms were tested. One approach involves dividing the 2D PISA effective regurgitant orifice area by a constant of 0.7 (EROA0.7). Another approach involves multiplying the unadjusted EROA by Vorifice/(Vorifice - Valiasing), where Vorifice denotes the TR jet velocity, and Valiasing represents the color aliasing velocity (EROAVo-Va). In vitro validation was performed on a commercially available multifunctional valve tester with different size orifices and peak pressure gradients. A true EROA was derived through the regurgitant volume (RVol) calculated from the tester. For clinical validation, RVol was calculated as the difference between the overall stroke volume and the forward stroke volume of the right ventricle. Volumetric EROA was derived by dividing the RVol by the TR velocity-time integral (VTI). The vena contracta area (VCA) was obtained through direct planimetry with 3D echocardiography. The mean of volumetric EROA and VCA served as the reference in clinical validation. Results: Excellent correlation between the calculated EROAs and the true EROA was observed in vitro (r=0.98, r=0.97, and r=0.98 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively; all P values <0.0001). EROAVo-Va underestimated the true EROA and averaged 33% (P=0.3163), while EROA0.7 overestimated the true EROA and averaged 8% (P=0.0032). Clinically, these methods consistently exhibited a notable underestimation that varied with the reference EROA. This systematic underestimation was mitigated by both algorithms when either the VCA (biases of 19.6, 15.1, and 11.8 mm2 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively) or the volumetric EROA (biases of 10.1, 5.6, and 2.3 mm2 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively) served as the reference. Their ability to distinguish severe TR was similar, with area under the curve values of 0.905, 0.903, and 0.893 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively. No statistically significant differences were observed for diagnostic accuracy (all P values >0.05). Conclusions: Using a correction factor of 0.7 in quantifying TR provides similar accuracy when compared to other techniques. This represents a valuable clinical tool for quickly correcting the underestimation of the 2D PISA method in TR. This simple method may increase the frequency of applying the correction and earlier recognition of patients with severe TR.

4.
Quant Imaging Med Surg ; 13(8): 5089-5099, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37581071

RESUMO

Background: Current guidelines recommend integrating several echocardiographic indices to evaluate the severity of tricuspid regurgitation (TR). Discordance of indices, including qualitative and quantitative methods, commonly exists in practice. The discordance among these parameters has not yet been fully elucidated. Methods: A total of 127 patients with recognizable TR jets without pulmonary regurgitation or intracardiac shunt were prospectively enrolled. We evaluated 8 parameters by 2-dimensional (2D) echocardiography: proximal iso-velocity surface area (PISA)-derived regurgitant volume (RVol), PISA-derived effective regurgitant orifice area (EROA), PISA radius, vena contracta width (VCW), color Doppler jet area, tricuspid valve annular diameter, inferior vena cava (IVC) diameter, and peak E wave. According to current guidelines, each echocardiographic parameter was determined to represent either severe or non-severe TR. A concordance score was calculated as the number of concordant parameters divided by 8, with a higher score reflecting better concordance. Data were further categorized into 3 subgroups: complete concordance (0 discordant parameters), high concordance (1-2 discordant parameters), and low concordance (3-4 discordant parameters). Results: The mean concordance score was 81%±17% for the entire cohort. There were 48 (38%) patients with complete concordance, including 6 patients with severe TR. In contrast, the low concordance group (n=43, 34%) mostly comprised severe TR patients (36 patients). When considering only EROA, RVol, and VCW, concordance improved, with 98 patients (77%) in complete agreement. Conclusions: Concordance seems limited when using echocardiographic parameters to assess TR severity. Applying only EROA, RVol, and VCW results in better concordance, as recommended by the current guidelines.

5.
Eur Radiol ; 33(5): 3052-3063, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36629927

RESUMO

OBJECTIVES: To investigate the prognostic value of coronary CT angiography (CCTA) in heart failure patients with preserved ejection fraction (HFpEF). METHODS: Between January 2009 and December 2013, 6497 participants (mean age 63 ± 9.4 [range 32-86] years; 4111 men) who underwent CCTA and echocardiography were prospectively included. Participants were divided into HFpEF group and without HFpEF group. The primary endpoint was major adverse cardiovascular events (MACEs), including cardiovascular mortality, nonfatal myocardial infarction (MI), or hospitalization for heart failure (HF). RESULTS: Among those participants, 3096 were identified with HFpEF and 3401 were without HFpEF. Higher prevalence of coronary atherosclerosis was observed in HFpEF group than those without (78.3% vs. 64.9%, p < 0.001). During a median of 11.0 [IQR: 9.0-12.0] years follow-up, participants with HFpEF exhibit a heightened risk of MACEs in CAD-RADS = 0, 1-2, and ≥ 3 respectively (p < 0.001 for all). In the risk-adjusted hazard analysis among participants with HFpEF, CAD-RADS = 1-2 increased a 2.5-time risk for non-fatal MI (adjusted HR: 2.5, 95% CI: 1.5 to 4.3, p < 0.001), while CAD-RADS ≥ 3 conferred 3.9-fold and 3.1-fold higher risk for cardiovascular mortality (adjusted HR: 3.9, 95% CI: 2.2 to 7.1, p < 0.001) and hospitalization due to HF (adjusted HR: 3.1, 95% CI: 1.9 to 5.3, p < 0.001) with reference to CAD-RADS = 0 respectively. CONCLUSIONS: Coronary artery disease is common in participants with HFpEF and associated with MACEs. Among those participants, the presence of CAD-RADS = 1-2 increased the risk of nonfatal MI, while CAD-RADS ≥ 3 were correlated with cardiovascular mortality and hospitalization due to HF. KEY POINTS: • Higher median of CACS and higher CAD-RADS categories were observed in the HFpEF group than those without (p < 0.001 for both). • Participants with HFpEF exhibit a heightened risk of MACEs in CAD-RADS = 0, 1-2, and ≥ 3 respectively (p < 0.001 for all). • In the risk-adjusted hazard analysis among participants with HFpEF, CAD-RADS =1-2 increased a 2.5-time risk for non-fatal MI (adjusted HR: 2.5, 95% CI: 1.5 to 4.3, p < 0.001) with reference to CAD-RADS = 0 respectively.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Infarto do Miocárdio , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prognóstico , Insuficiência Cardíaca/complicações , Angiografia por Tomografia Computadorizada , Volume Sistólico , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Fatores de Risco
6.
J Am Soc Echocardiogr ; 34(3): 270-278.e1, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33166630

RESUMO

BACKGROUND: Previous studies found different cutoffs of vena contracta area (VCA) to define severe tricuspid regurgitation (TR). The aim of this study was to investigate the factors associated with such variability by comparing technical variables and vendors. METHODS: Sixty-nine patients with scheduled tricuspid surgery were included in this prospective study. For each patient, TR data sets were obtained on three-dimensional color Doppler transthoracic echocardiography on at least two of three systems: GE Vivid E95 (n = 39), Siemens SC2000 Prime (n = 64), and Philips EPIQ 7C (n = 60). VCA was measured using default settings or with color baseline shifted on all three platforms and with minimal color gain (10%-20%) on the GE platform. RESULTS: Color gain reduction and baseline shift caused significant change sin VCA measurement (-46% and 10%, respectively). Intervendor comparison exhibited wide limits of agreement (narrowest range, -74% to 167%), with either default or optimized settings. Different technical settings, platforms, and reference methods all produced different VCA cutoffs for severe TR. CONCLUSIONS: VCA measurement in TR is sensitive to technical factors and demonstrates intervendor variability. Technical variables in VCA measurement should be reported in detail to allow comparison among research studies. The same vendor and settings should be used for longitudinal analysis of TR VCA in the same patient in multivendor echocardiography laboratories.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Tricúspide , Ecocardiografia Doppler em Cores , Humanos , Laboratórios , Estudos Prospectivos , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/diagnóstico por imagem
7.
Cardiovasc Ultrasound ; 18(1): 41, 2020 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-33050922

RESUMO

BACKGROUND: The quantification of tricuspid regurgitation(TR) using three-dimensional(3D) proximal isovelocity surface area (PISA) derived effective regurgitant orifice area (EROA) is feasible in functional TR. The aim of our study was to explore the diagnostic accuracy and utility of 3D PISA EROA in a larger population of different etiologies. METHODS: One hundred and seven patients with confirmed TR underwent 2D and 3D transthoracic echocardiography (TTE). 3D PISA EROA was calculated and EROA derived from 3D regurgitant volume (Rvol) was used as the reference. RESULTS: 3D PISA EROA showed better correlation in primary TR than in functional TR(r = 0.897, P < 0.01). 3D PISA EROA differentiated severe TR with comparable accuracy in patients with primary and functional etiology (Z-value 16.506 vs 21.202), but with different cut-offs (0.49cm2 vs. 0.41 cm2). The chi-square value for incorporated clinical symptoms, positive echocardiographic results and 3D PISA EROA to grade severe TR was higher than only included clinical symptoms or incorporated clinical symptoms and positive echocardiographic results (chi-square value 137.233, P < 0.01). CONCLUSION: TR quantification using 3D PISA EROA is feasible and accurate under different etiologies. It has incremental diagnostic value for evaluating severe TR.


Assuntos
Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/fisiopatologia
8.
Eur Heart J Case Rep ; 4(5): 1-8, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33426438

RESUMO

BACKGROUND: Diastolic mitral regurgitation (DMR) is a type of functional mitral regurgitation. Its occurrence in the diastolic phase of cardiac cycle renders DMR an easily ignored entity. Confusing it with systolic mitral regurgitation occasionally happens. The reversal of left atrioventricular pressure gradient during diastole and the incomplete closure of mitral valve are the essential conditions for DMR. Diastolic mitral regurgitation develops under various situations, where the mechanisms of diastolic reversal of left atrioventricular pressure gradient differ. CASE SUMMARY: Patient 1 was a 50-year-old man diagnosed with 2:1 second-degree atrioventricular block (AVB). Patient 2 was a 70-year-old man diagnosed with first-degree AVB. Patient 3 was a 66-year-old man diagnosed with atrial fibrillation with long intermission and occasional atrial flutter with unequal conduction. Patient 4 was a 54-year-old woman diagnosed with dilated cardiomyopathy with complete left bundle branch block. Patient 5 was a 36-year-old man diagnosed with severe acute aortic regurgitation secondary to subacute bacterial endocarditis. DISCUSSION: Although the degree of DMR is relatively mild, its appearance generally prompts further clinical considerations. The appreciation of DMR has an incremental value for diagnosing and evaluating the underlying cardiovascular disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA