Appl Radiat Isot ; 170: 109559, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33476941

RESUMO

From a commercial supplier, three independent lots of an aqueous solution containing 223Ra in equilibrium with its deteriorating progeny were considered for standardization, by using live-time anticoincidence counting (LTAC) in the Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI) Brazil. The ionization chamber calibration factors were obtained using measurements of independent lots of 223Ra in LTAC considering the absolute method in order to evaluate the constancy and reproducibility of the standardization. The calibration factors of three high-performance well-type ionization chamber systems and four commercial well-type ionization chambers were determined. The LTAC results showed that lots 2 and 3 were 1069.88 and 1097.44 kBq/kg, with corresponding relative standard uncertainties 0.12% and 0.20%, respectively. The spectrometry method results of each lot value were classified as positive by ANOVA hypothesis testing. The emission probabilities relating to the X- and γ-rays in region from 81 to 830 keV ware determined. Hence, LNMRI can provide calibration services for 223Ra.

2.
Appl Radiat Isot ; 166: 109323, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32795698

RESUMO

There are few long-lived radionuclides yielding high intensity gamma-rays emission with energies ranging from 100 keV to 500 keV that can be applied as radioactive gamma standard to calibrate HPGe detectors. Furthermore, this energy range represents the main emitted energies of the majority of radionuclides used in nuclear medicine. The Brazilian National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) has attempted to identify radionuclides that have the potential to be used as a calibration source due to their long half-life as well as their emission spectrum. Hence, LNMRI promotes standardization studies of gamma-emitting radionuclides that meet these criteria on order to disseminate them. Thorium-229, with its well-defined energies and relatively high intensities, is one such candidate radionuclide for the energy and full-energy peak efficiency calibration of high-purity gamma spectrometers. Thorium-229 was standardized by the method of 4παß(LS)-γ(NaI(Tl)) live timed anticoincidence counting. The emission intensities of gamma-rays associated with the decay of 229Th have been determined by HPGe gamma ray spectrometry with accuracy and precision. The results are in agreement with current literature data.

3.
Appl Radiat Isot ; 134: 64-67, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28942991

RESUMO

Traceability in Nuclear Medicine Service (NMS) measurements was checked by the Institute of Radioprotection and Dosimetry (IRD) through the Institute of Energy and Nuclear Research (IPEN). In 2016, IRD ran an intercomparison program and invited Brazilian NMS authorized to administer 131I to patients. Sources of 131I were distributed to 33 NMSs. Three other sources from the same solution were sent to IRD, after measurement at IPEN. These sources were calibrated in the IRD reference system. A correction factor of 1.013 was obtained. Ninety percent of the NMS comparisons results are within ±10% of the National Laboratory of Metrology of Ionizing Radiation (LNMRI) value, the Brazilian legal requirement.


Assuntos
Instituições de Assistência Ambulatorial , Radioisótopos do Iodo/análise , Serviço Hospitalar de Medicina Nuclear , Compostos Radiofarmacêuticos/análise , Brasil , Calibragem , Competência Profissional , Controle de Qualidade , Reprodutibilidade dos Testes , Fatores de Tempo , Incerteza
4.
Appl Radiat Isot ; 134: 316-320, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29107514

RESUMO

From a commercial supplier a solution containing 134Cs has been standardized at National Laboratory for Ionizing Radiation Metrology (LNMRI) for the first time using three Liquid scintillation based measurement. These measurement methods are 4πß-γ live-timed anticoincidence counting, 4πß-γ coincidence counting and 3H-standard efficiency tracing with the CNET methods. The results obtained by anticoincidence counting was adopted as reference value and its combined uncertainty was 0.38%. The agreement of this reference value with coincidence counting and CNET methods were 0.39% and 0.34% respectively and were in consistency with each uncertainty method. The weighted mean results coincidence counting and CNET methods are also in close agreement 0.03% with anticoincidence counting method and meets the requirement of primary and national standard. This standardization was made in order to reduce the uncertainty in 134Cs measurement in Brazil and also following a request made by Bureau International des Poids and Mesures for new submission to International Reference System. The LNMRI last submission was made in 1987. Therefore from a 134Cs master solution a NIST ampoules was prepared and LNMRI/IRD submitted it to the International Reference System, Bureau International of Poids and Measures (SIR/BIPM). In this paper will be analyzed the LNMRI measurement and performance each measurement methods and also take into account the reference value of KCDB, we determined also the 134Cs gamma emission probabilities of main energy.

5.
Appl Radiat Isot ; 134: 385-390, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29248210

RESUMO

An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)ß-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.

6.
Appl Radiat Isot ; 134: 307-311, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29153654

RESUMO

In this work, a 68(Ge+Ga) solution has been standardized at the National Institute of Ionizing Radiation Metrology (LNMRI), in Brazil, in the frame of an international key comparison CCRI(II)-K2.Ge-68 piloted by National Institute of Standards and Technology (NIST/USA). The 4πß(LS)-γ(NaI(Tl)) anticoincidence method with live-time and extended dead-time was used and its result was validated by 4πß(LS)-γ(NaI(Tl)) coincidence counting and liquid scintillation counting using the Triple to Double Coincidence Ratio (TDCR) method. The deviations of the activity concentration values of coincidence and TDCR measurements from the anticoincidence result were 1.7% and 0.63%, respectively, which were within experimental evaluated uncertainties at ~95% level of confidence (coverage factor k = 2). The combined relative standard uncertainties were 0.65%, 0.70% and 0.53% for anticoincidence, coincidence and TDCR methods, respectively. These values are consistent with the results reported by Cessna at the ICRM2017 conference.

7.
Appl Radiat Isot ; 134: 340-350, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29146526

RESUMO

The sum-peak method, an absolute measurement technique that uses coincidence counting and γ-ray spectrometry, was applied to activity standardization of 152Eu sources. The decay branch used was that of 152Sm, as it is almost entirely electron capture and exhibits X-rays with a high probability of coincidence with the 121.8keVgamma rays, as evidenced by the matrix technique used for complex decay schemes, a method for deriving counting rate equations describing coincidence summing of gamma and X-rays. The result was compared with the calibration performed by ionization chamber traceable to BIPM. The results presented uncertainty values of 0.50% (k = 1).

8.
Genet Mol Res ; 16(3)2017 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-28829901

RESUMO

Genetic variability of cassava (Manihot esculenta Crantz) in Brazil is wide, being this the result of natural and cultural selection during pre- and post-domestication of the species in different environments. Given the number of species of the genus found in the region (38 of a total of 98 species), the central region of Brazil was defined as the primary center of cassava diversity. Therefore, genetic diversity characterization of cassava accessions is fundamental, both for farmers and for plant breeders, because it allows the organization of genetic resources and better utilization of available genetic diversity. This research aims to assess genetic divergence of cassava accessions from the south-central region of the State of Mato Grosso, based on multi-categorical morphological traits. For this purpose, 38 qualitative and quantitative morphological descriptors were used. Genetic diversity was expressed by the genetic similarity index, with subsequent clustering of accessions by the modified Tocher's procedure and UPGMA. Of 38 descriptors, only growth habit of stem showed no variability. Tocher and UPGMA methods were efficient and corroborated on group composition. Both methods were able to group accessions of different localities in distinct group consistency.


Assuntos
Variação Genética , Manihot/genética , Brasil , Ecossistema , Manihot/anatomia & histologia , Característica Quantitativa Herdável
9.
Appl Radiat Isot ; 122: 37-40, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28092780

RESUMO

The absolute activity standardization measurement system of radionuclide by live-timed anticoincidence counting was implemented at LNMRI in 2008 to reduce the effects of some correction factors on the determination of activity with coincidence counting technique used for decades in the laboratory, for example, the corrections of dead time and resolution. With the live-timed anticoincidence system, the variety of radionuclides that can be calibrated by LNMRI was increased in relation to the type of decay. The objective of this study was to standardize the 106Ru activity, determine gamma emission probabilities by spectrometric method for some energies, and estimate measurement uncertainties.

10.
Appl Radiat Isot ; 109: 389-392, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26805708

RESUMO

(123)I is widely used for radiodiagnostic procedures. It is produced by reaction of (124)Xe (p,2n) (123)Cs →(123)Xe →(123)I in cyclotrons. (121)Te and (125)I appear in a photon energy spectrum as impurities. An activity of (121)Te was calibrated absolutely by sum-peak method and its photon emitting probability was estimated, whose results were consistent with published results.

11.
Hum Exp Toxicol ; 34(3): 300-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25005806

RESUMO

Diethylpropion has been available in the market for treating obesity for over 50 years. Refined studies are lacking to fully elucidate its action spectrum. The aim of our study was to evaluate possible toxic effects of anorectic diethylpropion in Chinese hamster ovary (CHO) cells. Comet assay (detects breaks in the DNA strand), micronucleus test (detects clastogenic/aneugenic damage), and cell survival test (detects cytotoxic damage) were used to evaluate the toxic effects. In comet assay, we found that the damage scores with diethylpropion treatments at the concentrations of 20 and 40 µg/mL were more significant ( p < 0.05) than that of the negative control. When assessing the possible aneugenic and/or clastogenic damage caused by the drug in CHO cells, we found no difference ( p > 0.05) in the values of micronucleated cells when comparing different diethylpropion treatments and the negative control. Regarding the cell viability, for all the diethylpropion concentrations tested, higher values ( p < 0.05) of apoptosis were found compared with those of the negative control. In relation to the number of necrotic cells, no difference ( p > 0.05) was noted between the means of the three concentrations of diethylpropion evaluated and the negative control. In the experimental conditions, we conclude that diethylpropion has weak genotoxic and cytotoxic activities.


Assuntos
Depressores do Apetite/toxicidade , Citotoxinas/toxicidade , Dietilpropiona/toxicidade , Mutagênicos/toxicidade , Animais , Células CHO , Sobrevivência Celular/efeitos dos fármacos , Ensaio Cometa , Cricetinae , Cricetulus , Dano ao DNA , Testes para Micronúcleos
12.
Appl Radiat Isot ; 70(9): 1825-30, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445396

RESUMO

An international Key Comparison of (177)Lu has recently been carried out. Twelve laboratories performed assays for radioactivity content on aliquots of a common master solution of (177)Lu, leading to eleven results submitted for entry into the Key Comparison Database of the Mutual Recognition Arrangement. A proposed Comparison Reference Value (CRV) was calculated to be 3.288(4)MBq/g using all eleven results. Degrees of equivalence and their uncertainties were calculated for each laboratory based on the CRV. Most of the values reported by the participating laboratories were within 0.6% of the CRV.


Assuntos
Lutécio/análise , Lutécio/química , Radioisótopos/análise , Radioisótopos/química , Radiometria/instrumentação , Radiometria/normas , Lutécio/normas , Doses de Radiação , Radioisótopos/normas , Padrões de Referência , Valores de Referência
13.
Appl Radiat Isot ; 70(9): 1924-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22406221

RESUMO

The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil participated in the last (57)Co activity measurement comparison organized by IAEA, in 2008. This was made in order to realize primary standardization of this radionuclide and to reduce the measuring uncertainties in the laboratory. Additionally, one sample with 2.6g was taken from the IAEA master solution of (57)Co and was prepared to be used in the measurement of the radionuclide's half-life in an ionization chamber system. The (57)Co half-life was measured to be 271.82 (17) days.


Assuntos
Radioisótopos de Cobalto/análise , Radioisótopos de Cobalto/química , Radiometria/instrumentação , Radiometria/normas , Brasil , Meia-Vida , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência
14.
Appl Radiat Isot ; 70(9): 2081-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22401938

RESUMO

The activities of (177)Lu, (111)In and (123)I solutions have been absolutely determined using three different measurement methods. (177)Lu solution was standardized using the 4πß(PC)-γ(NaI) coincidence and 4πß(LS)-γ(NaI) live-timed anticoincidence methods. For the (111)In and (123)I solutions, besides these two mentioned methods, the coincidence sum-peak method was also applied. The measured activities results using these different methods are consistent within the evaluated experimental uncertainties demonstrating the equivalence of these methods. As an additional contribution to nuclear data, the half-lives have been determined using a well type IG12 ionization chamber.


Assuntos
Radioisótopos/análise , Radioisótopos/normas , Radiometria/instrumentação , Radiometria/normas , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência
15.
Appl Radiat Isot ; 70(9): 2087-90, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22425414

RESUMO

A commercial solution of (65)Zn was standardized by the sum peak-method using a planar HPGe detector. The activity results were compared with measurements made with a well type 4πγ ionization chamber, which is traceable to BIPM.RI (II)-K2.Zn-65 key-comparison performed in 2002. The sum-peak value was 42.79 kBq/g and the ionization chamber value was 42.74 kBq/g both at the reference date. The uncertainty obtained in the sum peak standardization was 0.25% (k=1), and in the ionization chamber was 0.85% (k=1). The results showed that sum-peak method can be used in (65)Zn standardization and this method is easier, simpler and more practical than others methods.


Assuntos
Algoritmos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/instrumentação , Radiometria/normas , Radioisótopos de Zinco/análise , Radioisótopos de Zinco/normas , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência , Semicondutores , Radioisótopos de Zinco/química
16.
Appl Radiat Isot ; 70(9): 2056-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22417696

RESUMO

The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil acquired (166m)Ho and (243)Am/(239)Np solutions from commercial suppliers in order to realize primary standardization and therefore reducing the associated uncertainties. The method used in the standardization was the live-timed 4πß(LS)-γ(ΝaI(Tl)) anticoincidence counting. The live-timed anticoincidence system is operated since 2006 in LNMRI and is composed of two MTR2 modules donated by Laboratoire National Henri Becquerel (LNE-LNHB)/France. The data acquisition system uses a homemade LabView program and an Excel file for calculus. These systems have been used for primary standardization at LNMRI for many radionuclides and recently took part in the (124)Sb and (177)Lu International Key Comparisons with good performance.


Assuntos
Amerício/análise , Amerício/normas , Hólmio/normas , Netúnio/análise , Netúnio/normas , Radiometria/normas , Software/normas , Amerício/química , Brasil , Meia-Vida , Hólmio/análise , Internacionalidade , Linguagens de Programação , Doses de Radiação , Padrões de Referência , Valores de Referência
17.
Cephalalgia ; 30(9): 1133-6, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20713564

RESUMO

Tolosa-Hunt syndrome (THS) consists of a painful ophthalmoplegia with typical features in magnetic resonance imaging (MRI). The recurring nature of this affliction has been known since its first description. However, compromise of the contralateral cavernous sinus, known as alternating THS, is very rare and has never been examined using MRI. We report clinical data, laboratory data and imaging features of a patient with alternating THS. According to our literature review, this is the first MRI study of THS.


Assuntos
Artérias Carótidas/patologia , Seio Cavernoso/patologia , Imageamento por Ressonância Magnética , Órbita/patologia , Síndrome de Tolosa-Hunt/patologia , Feminino , Humanos , Adulto Jovem
18.
Appl Radiat Isot ; 68(7-8): 1207-10, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20153206

RESUMO

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.


Assuntos
Antimônio/análise , Antimônio/normas , Cooperação Internacional , Fótons , Valores de Referência , Reprodutibilidade dos Testes , Contagem de Cintilação , Soluções , Pesos e Medidas
19.
AJNR Am J Neuroradiol ; 31(6): 1059-62, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20053803

RESUMO

BACKGROUND AND PURPOSE: Hippocampal abnormalities are known as highly epileptogenic precursor lesions in the general population, primarily manifesting as MTS. The purpose of this study was to evaluate the occurrence of hippocampal abnormalities on MR imaging in patients with TS to explore the possible underlying mechanisms of the abnormalities and to identify the relationship between an abnormal HF and epilepsy. MATERIALS AND METHODS: We studied MR images and clinical data from 31 patients with TS. The MR imaging protocol was identical for all patients and included tilted coronal images of their temporal lobes. The diagnosis of TSC was made according to established criteria. The HFs of the patients were evaluated from coronal images according to size, morphology, and signal intensity. The data were submitted to statistical analysis, and P values < or = .05 were considered significant. RESULTS: We found HF abnormalities in 5 patients. Four had typical MTS, and 1 had HIMAL. We found a positive correlation between childhood febrile seizures and MTS in patients with TS. We also confirmed that patients with altered hippocampi had a tendency to exhibit more cortical tubers. CONCLUSIONS: Analysis of this series of patients demonstrated the presence of HF abnormalities, mainly MTS in patients with TS. We also found that the occurrence of febrile seizures during the first year of life appears to be one of the determining factors for MTS development in these patients.


Assuntos
Epilepsia do Lobo Temporal/patologia , Hipocampo/anormalidades , Hipocampo/patologia , Imageamento por Ressonância Magnética , Esclerose Tuberosa/patologia , Adolescente , Adulto , Atrofia , Criança , Pré-Escolar , Eletroencefalografia , Feminino , Humanos , Lactente , Masculino , Convulsões Febris/patologia , Lobo Temporal/patologia , Adulto Jovem
20.
Appl Radiat Isot ; 67(10): 1887-91, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19505830

RESUMO

The sum-peak method was applied to standardize a (57)Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.