Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 9577, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35688890

RESUMO

We present a compact multi-modal and multi-scale retinal imaging instrument with an angiographic functional extension for clinical use. The system integrates scanning laser ophthalmoscopy (SLO), optical coherence tomography (OCT) and OCT angiography (OCTA) imaging modalities and provides multi-scale fields of view. For high resolution, and high lateral resolution in particular, cellular imaging correction of aberrations by adaptive optics (AO) is employed. The entire instrument has a compact design and the scanning head is mounted on motorized translation stages that enable 3D self-alignment with respect to the subject's eye by tracking the pupil position. Retinal tracking, based on the information provided by SLO, is incorporated in the instrument to compensate for retinal motion during OCT imaging. The imaging capabilities of the multi-modal and multi-scale instrument were tested by imaging healthy volunteers and patients.


Assuntos
Pupila , Retina , Humanos , Oftalmoscopia/métodos , Óptica e Fotônica , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
2.
Eye Contact Lens ; 47(12): 631-637, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34797270

RESUMO

OBJECTIVES: As reported previously, tear film surface quality (TFSQ) should be considered in contact lens (CL) fitting. This study followed noninvasive keratograph tear film break-up time (NIKBUT) in CL wearers for 12 months to validate its clinical utility in predicting CL performance. METHODS: Fifty-five subjects (M/F=17/38) aged 26±4 years were prescribed silicone hydrogel or hydrogel CLs. The study included baseline measurements without CLs; 2 visits for CL fitting and control; follow-up after 3, 6, and 12 months of CL wear; and postwear visit without CLs. Ocular Surface Disease Index (OSDI), 8-Item Contact Lens Dry Eye Questionnaire (CLDEQ-8), first and mean NIKBUT (F/M-NIKBUT), fluorescein tear film break-up time (FBUT), and ocular surface staining were evaluated. RESULTS: Post hoc analysis of each pair of visits showed differences between baseline and all CL visits for F-NIKBUT, M-NIKBUT, FBUT, and corneal staining. No difference was reported in symptoms. In addition, differences between baseline and postwear visits were noted in OSDI, M-NIKBUT, FBUT, and corneal staining, with three of the latter parameters showing a downward trend. CONCLUSIONS: No changes in TFSQ and symptoms were reported over 12 months. Introducing NIKBUT as part of routine CL fitting is advised to improve CL fit and predict success.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Olho , Humanos , Lágrimas , Visão Ocular
3.
Alzheimers Res Ther ; 12(1): 144, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-33172499

RESUMO

INTRODUCTION: The eye offers potential for the diagnosis of Alzheimer's disease (AD) with retinal imaging techniques being explored to quantify amyloid accumulation and aspects of neurodegeneration. To assess these changes, this proof-of-concept study combined hyperspectral imaging and optical coherence tomography to build a classification model to differentiate between AD patients and controls. METHODS: In a memory clinic setting, patients with a diagnosis of clinically probable AD (n = 10) or biomarker-proven AD (n = 7) and controls (n = 22) underwent non-invasive retinal imaging with an easy-to-use hyperspectral snapshot camera that collects information from 16 spectral bands (460-620 nm, 10-nm bandwidth) in one capture. The individuals were also imaged using optical coherence tomography for assessing retinal nerve fiber layer thickness (RNFL). Dedicated image preprocessing analysis was followed by machine learning to discriminate between both groups. RESULTS: Hyperspectral data and retinal nerve fiber layer thickness data were used in a linear discriminant classification model to discriminate between AD patients and controls. Nested leave-one-out cross-validation resulted in a fair accuracy, providing an area under the receiver operating characteristic curve of 0.74 (95% confidence interval [0.60-0.89]). Inner loop results showed that the inclusion of the RNFL features resulted in an improvement of the area under the receiver operating characteristic curve: for the most informative region assessed, the average area under the receiver operating characteristic curve was 0.70 (95% confidence interval [0.55, 0.86]) and 0.79 (95% confidence interval [0.65, 0.93]), respectively. The robust statistics used in this study reduces the risk of overfitting and partly compensates for the limited sample size. CONCLUSIONS: This study in a memory-clinic-based cohort supports the potential of hyperspectral imaging and suggests an added value of combining retinal imaging modalities. Standardization and longitudinal data on fully amyloid-phenotyped cohorts are required to elucidate the relationship between retinal structure and cognitive function and to evaluate the robustness of the classification model.


Assuntos
Doença de Alzheimer , Tomografia de Coerência Óptica , Doença de Alzheimer/diagnóstico por imagem , Biomarcadores , Humanos , Curva ROC , Retina/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA