Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anesth Analg ; 126(2): 503-512, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28763357

RESUMO

BACKGROUND: The purpose of this study was to determine whether significant variation exists in the use of protective ventilation across individual anesthesia providers and whether this difference can be explained by patient, procedure, and provider-related characteristics. METHODS: The cohort consisted of 262 anesthesia providers treating 57,372 patients at a tertiary care hospital between 2007 and 2014. Protective ventilation was defined as a median positive end-expiratory pressure of 5 cm H2O or more, tidal volume of <10 mL/kg of predicted body weight and plateau pressure of <30 cm H2O. Analysis was performed using mixed-effects logistic regression models with propensity scores to adjust for covariates. The definition of protective ventilation was modified in sensitivity analyses. RESULTS: In unadjusted analysis, the mean probability of administering protective ventilation was 53.8% (2.5th percentile of provider 19.9%, 97.5th percentile 80.8%). After adjustment for a large number of covariates, there was little change in the results with a mean probability of 51.1% (2.5th percentile 24.7%, 97.5th percentile 77.2%). The variations persisted when the thresholds for protective ventilation were changed. CONCLUSIONS: There was significant variability across individual anesthesia providers in the use of intraoperative protective mechanical ventilation. Our data suggest that this variability is highly driven by individual preference, rather than patient, procedure, or provider-related characteristics.


Assuntos
Anestesia Geral/métodos , Anestesiologistas , Cuidados Intraoperatórios/métodos , Respiração Artificial/métodos , Adulto , Idoso , Anestesia Geral/tendências , Anestesiologistas/tendências , Estudos de Coortes , Feminino , Humanos , Cuidados Intraoperatórios/tendências , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/métodos , Respiração com Pressão Positiva/tendências , Estudos Prospectivos , Sistema de Registros , Respiração Artificial/tendências , Volume de Ventilação Pulmonar/fisiologia
2.
Ann Surg ; 264(2): 362-369, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26496082

RESUMO

OBJECTIVES: In this study, we examined whether (1) positive end-expiratory pressure (PEEP) has a protective effect on the risk of major postoperative respiratory complications in a cohort of patients undergoing major abdominal surgeries and craniotomies, and (2) the effect of PEEP is differed by surgery type. BACKGROUND: Protective mechanical ventilation with lower tidal volumes and PEEP reduces compounded postoperative complications after abdominal surgery. However, data regarding the use of intraoperative PEEP is conflicting. METHODS: In this observational study, we included 5915 major abdominal surgery patients and 5063 craniotomy patients. Analysis was performed using multivariable logistic regression. The primary outcome was a composite of major postoperative respiratory complications (respiratory failure, reintubation, pulmonary edema, and pneumonia) within 3 days of surgery. RESULTS: Within the entire study population (major abdominal surgeries and craniotomies), we found an association between application of PEEP ≥5 cmH2O and a decreased risk of postoperative respiratory complications compared with PEEP <5 cmH2O. Application of PEEP >5 cmH2O was associated with a significant lower odds of respiratory complications in patients undergoing major abdominal surgery (odds ratio 0.53, 95% confidence interval 0.39 - 0.72), effects that translated to deceased hospital length of stay [median hospital length of stay : 6 days (4-9 days), incidence rate ratios for each additional day: 0.91 (0.84 - 0.98)], whereas PEEP >5 cmH2O was not significantly associated with reduced odds of respiratory complications or hospital length of stay in patients undergoing craniotomy. CONCLUSIONS: The protective effects of PEEP are procedure specific with meaningful effects observed in patients undergoing major abdominal surgery. Our data suggest that default mechanical ventilator settings should include PEEP of 5-10 cmH2O during major abdominal surgery.


Assuntos
Abdome/cirurgia , Craniotomia/efeitos adversos , Cuidados Intraoperatórios , Respiração com Pressão Positiva , Complicações Pós-Operatórias/prevenção & controle , Transtornos Respiratórios/prevenção & controle , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA