Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Rev Esp Enferm Dig ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39297589

RESUMO

We present the case of a 57-year-old woman with metastatic colorectal cancer being treated with Bevacizumab and FOLFOX, who came to the emergency department with haematemesis. Gastroscopy showed a duodenal ulcer without active bleeding. Subsequently, he suffered haemodynamic instability and an Angio-CT scan revealed an aortoenteric fistula, requiring urgent surgery. Bevacizumab can cause rare complications such as this, and early detection is crucial for effective treatment.

2.
Rev Esp Enferm Dig ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39297603

RESUMO

We present the case of a 75-year-old woman who presented to our hospital with upper gastrointestinal bleeding and altered liver function tests. MR cholangiography performed during hospitalization revealed a choledochoduodenal fistula. Gastroscopy confirmed the presence of this fistula, and after surgical correction, an adenocarcinoma at the biliopancreatic junction infiltrating the duodenum was diagnosed. This represents a rare and unusual presentation of biliopancreatic tumors, with endoscopy playing a crucial role in diagnosis.

3.
Shock ; 61(6): 885-893, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38662580

RESUMO

ABSTRACT: Sepsis is the most frequent risk factor for acute kidney injury (AKI) in critically ill infants. Sepsis-induced dysregulation of kidney microcirculation in newborns is unresolved. The objective of this study was to use the translational swine model to evaluate changes in kidney function during the early phase of sepsis in newborns and the impact of fluid plus norepinephrine resuscitation. Newborn pigs (3-7-day-old) were allocated randomly to three groups: 1) sham, 2) sepsis (cecal ligation and puncture) without subsequent resuscitation, and 3) sepsis with lactated Ringer plus norepinephrine resuscitation. All animals underwent standard anesthesia and mechanical ventilation. Cardiac output and glomerular filtration rate were measured noninvasively. Mean arterial pressure, total renal blood flow, cortical perfusion, medullary perfusion, and medullary tissue oxygen tension (mtPO 2 ) were determined for 12 h. Cecal ligation and puncture decreased mean arterial pressure and cardiac output by more than 50%, with a proportional increase in renal vascular resistance and a 60-80% reduction in renal blood flow, cortical perfusion, medullary perfusion, and mtPO 2 compared to sham. Cecal ligation and puncture also decreased glomerular filtration rate by ~79% and increased AKI biomarkers. Isolated foci of tubular necrosis were observed in the septic piglets. Except for mtPO 2 , changes in all these parameters were ameliorated in resuscitated piglets. Resuscitation also attenuated sepsis-induced increases in the levels of plasma C-reactive protein, proinflammatory cytokines, lactate dehydrogenase, alanine transaminase, aspartate aminotransferase, and renal NLRP3 inflammasome. These data suggest that newborn pigs subjected to cecal ligation and puncture develop hypodynamic septic AKI. Early implementation of resuscitation lessens the degree of inflammation, AKI, and liver injury.


Assuntos
Injúria Renal Aguda , Animais Recém-Nascidos , Hidratação , Norepinefrina , Ressuscitação , Sepse , Animais , Suínos , Sepse/terapia , Sepse/fisiopatologia , Ressuscitação/métodos , Hidratação/métodos , Injúria Renal Aguda/terapia , Injúria Renal Aguda/metabolismo , Inflamação , Rim/metabolismo , Circulação Renal , Taxa de Filtração Glomerular
4.
Eur J Intern Med ; 120: 99-106, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37872034

RESUMO

BACKGROUND AND AIMS: Controversial data have been reported regarding the prevalence of Non-Alcoholic Fatty Liver Disease (NAFLD) in Inflammatory Bowel Disease (IBD) population and IBD-related risk factors. The aim of the study was to assess the prevalence and risk factors associated with NAFLD and liver fibrosis in IBD participants compared with non-IBD controls. METHODS: Cross-sectional, case-control study including 741 IBD cases and 170 non-IBD controls, matched by sex and age. All participants underwent liver ultrasound, transient elastography and laboratory tests. A logistic regression multivariable analysis was performed adjusting for classic metabolic risk factors and history of systemic steroid use. RESULTS: The prevalence of NAFLD and significant liver fibrosis was 45 % and 10 % in IBD group, and 40 % and 2.9 % in non-IBD group (p = 0.255 and 0.062, respectively). Longer IBD duration (aOR 1.02 95% CI (1.001-1.04)) and older age at IBD diagnosis (aOR 1.02 95 % CI (1.001-1.04)) were independent risk factors for NAFLD in IBD group. Crohn´s Disease was an independent risk factor for significant liver fibrosis in participants with IBD and NAFLD (aOR 3.97 95 % CI (1.78-8.96)). NAFLD occurred at lower BMI levels in IBD group with NAFLD compared to non-IBD group with NAFLD (aOR 0.92 95 % CI (0.87-0.98)). CONCLUSIONS: Although we found no differences in the prevalence of NAFLD and liver fibrosis between IBD group and non-IBD group, our findings suggest that liver fibrosis progression should be closely monitored in patients with concomitant CD and NAFLD, more in particular in those with long standing active disease.


Assuntos
Doença de Crohn , Doenças Inflamatórias Intestinais , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Doença de Crohn/complicações , Doença de Crohn/epidemiologia , Estudos de Casos e Controles , Estudos Transversais , Fatores de Risco , Doenças Inflamatórias Intestinais/complicações , Cirrose Hepática/complicações , Prevalência
6.
Cancers (Basel) ; 15(13)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37444477

RESUMO

The aim of the systematic review is to assess the prevalence and risk factors of liver fibrosis in patients with Inflammatory Bowel Disease (IBD) and Non-Alcoholic Fatty Liver Disease (NAFLD) and to discuss the role of liver fibrosis in the progression to hepatocellular carcinoma (HCC). We performed a structured search in PubMed, Web of Science, Embase, and Scopus up to 3 March 2023 to identify observational studies reporting liver fibrosis in patients with NAFLD and IBD. Quality of studies was assessed using the Newcastle-Ottawa Scale (NOS) score. A total of 23 studies met our inclusion criteria, including 629,781 patients. A total of 10 cross-sectional, 3 case-control, and 10 cohort studies were included. Fourteen studies had a NOS score ≥ 7 points. NAFLD was diagnosed in 2162/6332 (34.1%) IBD participants. However, NAFLD diagnosis was established in 924/2962 (31.2%) healthy individuals without IBD. Advanced liver fibrosis was found in 116 (11.6%) of 992 IBD patients with NAFLD. Most studies found an association between NAFLD and classic cardiovascular risk factors such as older age, male sex, higher BMI, diabetes, hypertension and dyslipidemia. In addition, metabolic syndrome features were also associated with an increased risk of significant and advanced liver fibrosis. Although no strong association between NAFLD and IBD therapy was reported, some studies associated NAFLD with IBD diagnosis, Crohn's Disease, a complicated course of IBD, disease activity, and IBD duration. Advanced liver fibrosis was also associated with Crohn's disease in several studies. In conclusion, NAFLD and advanced liver fibrosis are prevalent and clinically relevant extraintestinal manifestations, so its diagnosis and potential progression to HCC should be carefully considered in daily clinical practice.

7.
Cancers (Basel) ; 15(3)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36765829

RESUMO

Chronic inflammation in patients with Inflammatory Bowel Disease (IBD) leads to an increased risk of colorectal cancer, small bowel cancer, intestinal lymphoma and cholangiocarcinoma. However, treatments for IBD have also been associated with an increased risk of neoplasms. Patients receiving Thiopurines (TPs) have an increased risk of hematologic malignancies, non-melanoma skin cancer, urinary tract neoplasms and cervical cancer. Anti-TNFs have been associated with a higher risk of neoplasms, mainly lymphomas and melanomas; however, the data are controversial, and some recent studies do not confirm the association. Nevertheless, other biologic agents, such as ustekinumab and vedolizumab, have not shown an increased risk of any neoplasm to date. The risk of malignancies with tofacitinib exists, but its magnitude and relationship with previous treatment with TPs is not defined, so more studies from daily clinical practice are needed. Although biologic therapy seems to be safe for patients with current cancer or a prior history of cancer, as has been demonstrated in other chronic inflammatory conditions, prospective studies in this specific population are needed. Until that time, it is crucial to manage such conditions via the combined clinical expertise of the gastroenterologist and oncologist.

8.
Polymers (Basel) ; 14(19)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36236029

RESUMO

Urothelial tumour of the upper urinary tract is a rare neoplasm, but unfortunately, it has a high recurrence rate. The reduction of these tumour recurrences could be achieved by the intracavitary instillation of adjuvant chemotherapy after nephron-sparing treatment in selected patients, but current instillation methods are ineffective. Therefore, the aim of this in vitro study is to evaluate the cytotoxic capacity of a new instillation technology through a biodegradable ureteral stent/scaffold coated with a silk fibroin matrix for the controlled release of mitomycin C as an anti-cancer drug. Through a comparative study, we assessed, in urothelial carcinoma cells in a human cancer T24 cell culture for 3 and 6 h, the cytotoxic capacity of mitomycin C by viability assay using the CCK-8 test (Cell counting Kit-8). Cell viability studies in the urothelial carcinoma cell line confirm that mitomycin C embedded in the polymeric matrix does not alter its cytotoxic properties and causes a significant decrease in cell viability at 6 h versus in the control groups. These findings have a clear biomedical application and could be of great use to decrease the recurrence rate in patients with upper tract urothelial carcinomas by increasing the dwell time of anti-cancer drugs.

9.
Rev. gastroenterol. Peru ; 42(4)oct. 2022.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1423952

RESUMO

Presentamos el caso de un varón de 64 años quien, tras un primer episodio de pancreatitis aguda necrotizante, reingresa a los 20 días por cuadro de dolor epigástrico intenso y posteriormente episodio de hemorragia digestiva alta en forma de hematemesis y melenas con inestabilización hemodinámica. Se realiza en ese momento gastroscopia urgente objetivándose probable fistula gastrointestinal en bulbo duodenal con coágulo adherido sin sangrado activo en ese momento por lo que se realiza angio-TC urgente que revela colección peripancreática necrótica con presencia de sangrado activo en su interior, procedente de la arteria pancreatoduodenal. La arteriografía urgente identificó imagen compatible con pseudoaneurisma arterial dependiente de la rama de arteria pancreatoduodenal, que fue embolizada con éxito. Desgraciadamente el paciente falleció en las horas posteriores, como consecuencia de un shock séptico secundario a colección pancreática infectada.


We present the case of a 64-year-old man who, after a first episode of acute pancreatitis, was readmitted 20 days later due to severe epigastric pain and later an episode of upper gastrointestinal bleeding in the form of hematemesis and melena with hemodynamic instability. An urgent gastroscopy was performed at that time, revealing a probable gastrointestinal fistula in the duodenal bulb with an adherent clot without active bleeding at that time, so an urgent CT angiography was performed that revealed a necrotic peripancreatic collection with the presence of active bleeding inside from the pancreatoduodenal artery. Urgent arteriography identified an image compatible with arterial pseudoaneurysm dependent on the pancreaticoduodenal artery branch, which was successfully embolized. Unfortunately, the patient died a few hours later as a result of septic shock secondary to an infected pancreatic collection.

10.
Polymers (Basel) ; 14(15)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35956574

RESUMO

A major limitation of the treatment of low-grade upper tract urothelial carcinoma is the difficulty of intracavitary instillation of adjuvant therapy. Therefore, the aim of this in vitro study was to develop and to assess a new design of biodegradable ureteral stent coated with a silk fibroin matrix for the controlled release of mitomycin C as a chemotherapeutic drug. For this purpose, we assessed the coating of a biodegradable ureteral stent, BraidStent®, with silk fibroin and subsequently loaded the polymeric matrix with two formulations of mitomycin to evaluate its degradation rate, the concentration of mitomycin released, and changes in the pH and the weight of the stent. Our results confirm that the silk fibroin matrix is able to coat the biodegradable stent and release mitomycin for between 6 and 12 h in the urinary environment. There was a significant delay in the degradation rate of silk fibroin and mitomycin-coated stents compared to bare biodegradable stents, from 6-7 weeks to 13-14 weeks. The present study has shown the feasibility of using mitomycin C-loaded silk fibroin for the coating of biodegradable urinary stents. The addition of mitomycin C to the coating of silk fibroin biodegradable stents could be an attractive approach for intracavitary instillation in the upper urinary tract.

11.
Polymers (Basel) ; 14(16)2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-36015581

RESUMO

The insertion of a ureteral stent provides acute care by restoring urine flow and alleviating urinary retention or dysfunction. The problems of encrustation, bacterial colonization and biofilm formation become increasingly important when ureteral stents are left in place for a longer period of time. One way to reduce encrustation and bacterial adherence is to modify the stent surface with a diamond-like carbon coating, in combination with copper doping. The biocompatibilities of the Elastollan® base material and the a-C:H/Cu-mulitilayer coating were tested in synthetic urine. The copper content in bladder tissue was determined by atomic absorption spectroscopy and in blood and in urine by inductively coupled plasma mass spectrometry. Encrustations on the materials were analyzed by scanning electron microscopy, energy dispersive X-ray spectroscopy and Fourier transform infrared spectroscopy. A therapeutic window for copper ions of 0.5-1.0 mM was determined to kill bacteria without affecting human urothelial cells. In the rat animal model, it was found that copper release did not reach toxic concentrations in the affecting tissue of the urinary tract or in the blood. The encrustation behavior of the surfaces showed that the roughness of the amorphous carbon layer with the copper doping is probably the causal factor for the higher encrustation.

12.
Am J Clin Exp Urol ; 10(1): 1-12, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35291418

RESUMO

OBJECTIVES: The control and predictability of degradation rates and the absence of obstructive phenomena are two main challenges for research regarding biodegradable ureteral stents. The objectives are to assess the degradation performance and safety of braided combinations of three synthetic biodegradable polymers and copolymers; and to evaluate the interference of a heparin dip coating on degradation and bacterial colonization. METHODS: The hydrolysis of polyglycolic acid (PGA), poly lactic-co-glycolic acid (PLGA) and Glycomer™ 631 is assessed in this in vitro study that comprises ten groups. Stent samples present a braided arrangement and are incubated in porcine urine that undergoes analysis and exchange every 48 h until degradation. Coating is carried out with sodium heparin via dip coating and determination of the heparin release is carried out by ELISA test. Variables of study are stent mass, mass fold change, degradation time, bacterial colonization and concentration of heparin released in artificial urine. RESULTS: There is statistical significance in degradation times between all materials except between the Glycomer™ 631 alone and combined with PGA. Mass fold change analysis of the Glycomer™ 631 evidences an increasing trend of its mass during degradation. The combination of Glycomer™ 631 and PGA presents a progressive and gradual degradation, where PGA degrades at week 3 while Glycomer™ 631 remains intact until its fragmentation at the late stage of degradation. Heparin coating has no significant impact on mean degradation times and trends in any group, nor on bacteriuria rates; heparin concentration decreases significantly after 72 h. Products of degradation are released steadily with minimum dimensions. CONCLUSIONS: The combination of synthetic biodegradable polymers and copolymers with different degradation rates provides a gradual staged degradation. Heparin dip coating is a safe and feasible technique to coat biodegradable ureteral stents without interfering in degradation rates although it does not have a significant effect on the onset of bacterial colonization.

13.
Rev Gastroenterol Peru ; 42(4): 261-263, 2022.
Artigo em Espanhol | MEDLINE | ID: mdl-36746468

RESUMO

We present the case of a 64-year-old man who, after a first episode of acute pancreatitis, was readmitted 20 days later due to severe epigastric pain and later an episode of upper gastrointestinal bleeding in the form of hematemesis and melena with hemodynamic instability. An urgent gastroscopy was performed at that time, revealing a probable gastrointestinal fistula in the duodenal bulb with an adherent clot without active bleeding at that time, so an urgent CT angiography was performed that revealed a necrotic peripancreatic collection with the presence of active bleeding inside from the pancreatoduodenal artery. Urgent arteriography identified an image compatible with arterial pseudoaneurysm dependent on the pancreaticoduodenal artery branch, which was successfully embolized. Unfortunately, the patient died a few hours later as a result of septic shock secondary to an infected pancreatic collection.


Assuntos
Falso Aneurisma , Pancreatite , Masculino , Humanos , Pessoa de Meia-Idade , Pancreatite/complicações , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico , Doença Aguda , Hemorragia Gastrointestinal/complicações , Duodeno/irrigação sanguínea
14.
Expert Rev Med Devices ; 18(7): 697-705, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34085555

RESUMO

Introduction: Urinary stents have been around for the last 4 decades, urinary catheters even longer. They are associated with infections, encrustation, migration, and patient discomfort. Research efforts to improve them have shifted onto molecular and cellular levels. ENIUS brought together translational scientists to improve urinary implants and reduce morbidity.Methods & materials: A working group within the ENIUS network was tasked with assessing future research lines for the improvement of urinary implants.Topics were researched systematically using Embase and PubMed databases. Clinicaltrials.gov was consulted for ongoing trials.Areas covered: Relevant topics were coatings with antibodies, enzymes, biomimetics, bioactive nano-coats, antisense molecules, and engineered tissue. Further, pH sensors, biodegradable metals, bactericidal bacteriophages, nonpathogenic uropathogens, enhanced ureteric peristalsis, electrical charges, and ultrasound to prevent stent encrustations were addressed.Expert opinion: All research lines addressed in this paper seem viable and promising. Some of them have been around for decades but are yet to proceed to clinical application (i.e. tissue engineering). Others are very recent and, at least in urology, still only conceptual (i.e. antisense molecules). Perhaps the most important learning point resulting from this pan-European multidisciplinary effort is that collaboration between all stakeholders is not only fruitful but also truly essential.


Assuntos
Pesquisa Interdisciplinar , Stents , Cateteres Urinários , Humanos
15.
Transl Androl Urol ; 10(4): 1700-1710, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33968658

RESUMO

BACKGROUND: We assessed an antireflux biodegradable heparin-coated ureteral stent (BraidStent®-H) in an animal model comparative study after endoscopic treatment of ureteral strictures. METHODS: A total of 24 female pigs underwent initial endoscopic, nephrosonographic, and contrast fluoroscopy assessment of the urinary tract. Afterward, unilateral laparoscopic ureteral stricture model was performed. Three weeks later, the animals underwent laser endoureterotomy and were randomly assigned to Group-I, in which a double-pigtail stent was placed for 6 weeks, or Group-II, in which a BraidStent®-H was placed. Follow-up was carried out by ultrasonography, contrast fluoroscopy, ureteroscopy, urinalysis and bacteriuria assessment at 3, 6, 12 and 5 months. Finally, a pathological study of the urinary system was performed. RESULTS: There were no animals in Group-II with vesicoureteral reflux, with significance at 6 weeks with Group-I. Distal ureteral peristalsis was maintained in 50-75% in Group-II at 1-6 weeks. The 91.7% of stents in Group-II were degraded between 3-6 weeks, without obstructive fragments. Bacteriuria in Group II was 33.3-50% at 3 and 6 weeks. The global success rate by groups was 91.6% and 87.5% in groups I and II, respectively, with no statistical significance. CONCLUSIONS: BraidStent®-H has been shown to be as efficacious as current ureteral stents in the treatment of benign ureteral strictures following laser endoureterotomy. In addition, it reduces the morbidity associated with current stents and has a homogeneous and predictable degradation rate of about 6 weeks, with no obstructive fragments. Future studies are required to improve the antibacterial coating to reduce BraidStent®-H contamination in view of the results obtained with the heparin coating.

16.
Urol Int ; 105(7-8): 554-559, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33951641

RESUMO

INTRODUCTION: The aim of this experimental study is to assess, in a porcine model, the onset and grades of vesicoureteral reflux associated with ureteral stents. METHODS: Twenty-four female porcine models were used. A 4.7-Fr ureteral stent was placed in all right ureters and kept in place for 6 weeks. Follow-ups were performed on weeks 1, 3, 6, and 12. Ultrasonography, cystoscopy, and fluoroscopy were used to analyze grade of hydronephrosis, presence and grade of vesicoureteral reflux, bacteriuria, and macroscopic changes of the ureteral orifices. Vesicoureteral reflux was classified using a modification of the International Reflux Study Committee grades. RESULTS: 91.7% animals present vesicoureteral reflux, 89.5% grade IA, 3.5% grade IB, and 7% grade II. There is a significant increase in reflux during follow-ups at 3 and 6 weeks, whereas 6 weeks after removal, 26.3% of the ureters still present vesicoureteral reflux. Hydronephrosis and macroscopic changes of the ureteral orifice increase significantly with stenting, but there is no significant association between them and vesicoureteral reflux; the relationship between bacteriuria and the presence of vesicoureteral reflux is not significant either. CONCLUSION: Vesicoureteral reflux caused by ureteral stents in an animal model is mostly low grade and mainly affects the distal ureter.


Assuntos
Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Stents/efeitos adversos , Ureter/cirurgia , Refluxo Vesicoureteral/diagnóstico , Refluxo Vesicoureteral/etiologia , Animais , Feminino , Complicações Pós-Operatórias/classificação , Índice de Gravidade de Doença , Suínos , Refluxo Vesicoureteral/classificação
17.
BMC Urol ; 21(1): 32, 2021 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33639905

RESUMO

BACKGROUND: Double J ureteral stents are widely used on urological patients to provide drainage of the upper urinary tract. Unfourtunately, ureteral stents are not free from complications, as bacterial colonization and require a second procedure for removal. The purpose of the current comparative experimental study is to evaluate a new heparin-coated biodegradable antireflux ureteral stent (BraidStent®-H) to prevent urinary bacterial colonization. METHODS: A total of 24 female pigs were underwent determination of bacteriuria and nephrosonographic, endoscopic and contrast fluoroscopy assessment of the urinary tract. Afterward, were randomly assigned animals to Group-I, in which a 5Fr double-pigtail ureteral stent was placed for 6 weeks, or Group-II, in which a BraidStent®-H was placed. Follow-up assessments were performed at 1, 3, 6, 8, 12 weeks. The final follow-up includes the above methods and an exhaustive pathological study of the urinary tract was accomplished after 20 weeks. RESULTS: Bacteriuria findings in the first 48 h were significant between groups at 6 h and 12 h. Asymptomatic bacteriuria does not reach 100% of the animals in Group-II until 48 h versus Group-I where it appears at 6 h. The weekly bacteriuria mean rate was 27.7% and 44.4% in Group I and II respectively, without statistical significance. In Group II there were no animals with vesicoureteral reflux, with statistical significance at 3 and 6 weeks with Group-I. The 91.2% of stents in Group-II were degraded between 3 and 6 weeks, without obstructive fragments. Distal ureteral peristalsis was maintained in 66.6-75% in Group-II at 1-6 weeks. CONCLUSIONS: The heparin coating of BraidStent® allows an early decrease of bacterial colonization, but its effectiveness is low at the long term. Heparin coating did not affect scheduled degradation rate or size of stents fragments. BraidStent®-H avoids the side effects associated with current ureteral stents, thus should cause less discomfort to patients.


Assuntos
Bacteriúria/prevenção & controle , Stents Farmacológicos , Heparina/análise , Ureter/cirurgia , Refluxo Vesicoureteral/prevenção & controle , Implantes Absorvíveis , Animais , Modelos Animais de Doenças , Feminino , Distribuição Aleatória , Suínos
18.
J Endourol ; 35(8): 1244-1249, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33626973

RESUMO

Objective: The aim is to assess the effectiveness of a biodegradable antireflux ureteral stent with heparin coating in a comparative study (BraidStent®-H) in an animal model for the treatment of iatrogenic ureteral perforation. Materials and Methods: A total of 24 female pigs underwent initial endoscopic, nephrosonographic, and contrast fluoroscopy assessment of the urinary tract. Afterward, unilateral iatrogenic perforation in proximal ureter model was performed. Then the animals were randomly assigned to Group-I, in which a double-pigtail stent was placed for 6 weeks, or Group-II, in which a BraidStent-H a biodegradable heparin-coated stent was placed. Follow-up assessments were performed at 1 and 6 weeks and 5 months. Results: In terms of therapeutic effectiveness, complete resolution was observed in 95.8% of Group-I animals and 87.5% in Group-II. No animals in Group-II showed vesicoureteral reflux (VUR) during the study; statistical significance was observed at 1 and 6 weeks versus Group-I. All stents in Group-II degraded without producing obstructive fragments and allowed distal ureteral peristalsis. Heparin coating was not efficient to reduce asymptomatic bacteriuria between groups. Pathologic assessment did not show any significance in the global score, but did in the "fibrosis in muscular layer" parameter, at the ureteral perforation healing area; Group-II showed higher healing quality. Conclusions: The biodegradable intraureteral BraidStent®-H is highly effective for the minimally invasive treatment of ureteral perforation, since it displays controlled and predictable degradation, avoiding the development of VUR as well as irritation of the bladder trigone. Unfortunately, heparin coating was not effective in avoiding stent-associated bacteriuria.


Assuntos
Ureter , Animais , Modelos Animais de Doenças , Feminino , Heparina/farmacologia , Doença Iatrogênica , Stents , Suínos , Ureter/cirurgia
20.
J Endourol ; 34(3): 359-365, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31931610

RESUMO

Objective: The aim was to assess a new biodegradable and antireflux intraureteral stent (BraidStent®) design in a swine model after ureteral laparoscopic operation. Materials and Methods: A total of 24 female pigs underwent initial endoscopic, nephrosonographic, and contrast fluoroscopy assessment of the urinary tract. Afterward, unilateral ureteropelvic junction obstruction was performed by laparoscopic approach. Six weeks later, the animals underwent laparoscopic Anderson-Hynes pyeloplasty, and were randomly assigned to Group-I, in which a double-pigtail ureteral stent was inserted for 6 weeks, or Group-II, in which a BraidStent®, a biodegradable intraureteral stent design, was placed. Follow-up assessments were performed at 3 and 6 weeks and 5 months. Results: In terms of therapeutic success, complete resolution was observed in 91.6% of Group-I animals and 88.8% in Group-II. No evidence of vesicoureteral reflux (VUR) was observed in Group-II animals and statistical significance in VUR and ureteral orifice damage were observed between groups. BraidStent® degradation occurred in a controlled manner between 3 and 6 weeks, without obstructive fragments. Distal ureteral peristalsis was maintained in 66.6% and 83.3% in Group-II at 3 and 6 weeks of follow-up, respectively. In Group-II, the positive bacteriuria rate was 41.6% and the migration rate 25%. Pathological assessment showed a significant improvement in ureteral healing in Group-II vs Group-I. Conclusions: The results of this comparative study in a porcine model indicate that the intraureteral BraidStent performed similarly to conventional ureteral stents. It avoids complete ureteral length intubation, the adverse effects associated with conventional ureteral stents, and maintains a high level of distal ureteral peristalsis. Moreover, the BraidStent® exhibited a predictable and controlled degradation rate and did not cause any obstructive fragments. However, further studies are needed to improve the anchoring system and reduce the risk of bacterial colonization.


Assuntos
Implantes Absorvíveis , Stents , Obstrução Ureteral/cirurgia , Animais , Modelos Animais de Doenças , Feminino , Laparoscopia , Complicações Pós-Operatórias/prevenção & controle , Suínos , Refluxo Vesicoureteral/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA