Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Talanta ; 245: 123441, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35405444

RESUMO

Illicit-drug production, trafficking and seizures are on an all-time high. This consequently raises pressure on investigative authorities to provide rapid forensic results to assist law enforcement and legal processes in drug-related cases. Ideally, every police officer is equipped with a detector to reliably perform drug testing directly at the incident scene. Such a detector should preferably be small, portable, inexpensive and shock-resistant but should also provide sufficient selectivity to prevent erroneous identifications. This study explores the concept of on-site drugs-of-abuse detection using a 1.8 × 2.2 mm2 multipixel near-infrared (NIR) spectral sensor that potentially can be integrated into a smartphone. This integrated sensor, based on an InGaAs-on-silicon technology, exploits an array of resonant-cavity enhanced photodetectors without any moving parts. A 100% correct classification of 11 common illicit drugs, pharmaceuticals and adulterants was achieved by chemometric modelling of the response of 15 wavelength-specific pixels. The performance on actual forensic casework was investigated on 246 cocaine-suspected powders and 39 MDMA-suspected ecstasy tablets yielding an over 90% correct classification in both cases. These findings show that presumptive drug testing by miniaturized spectral sensors is a promising development ultimately paving the way for a fully integrated drug-sensor in mobile communication devices used by law enforcement.


Assuntos
Cocaína , Drogas Ilícitas , N-Metil-3,4-Metilenodioxianfetamina , Smartphone , Detecção do Abuso de Substâncias
2.
Drug Test Anal ; 13(5): 1054-1067, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33354929

RESUMO

Handheld Raman spectroscopy is an emerging technique for rapid on-site detection of drugs of abuse. Most devices are developed for on-scene operation with a user interface that only shows whether cocaine has been detected. Extensive validation studies are unavailable, and so are typically the insight in raw spectral data and the identification criteria. This work evaluates the performance of a commercial handheld Raman spectrometer for cocaine detection based on (i) its performance on 0-100 wt% binary cocaine mixtures, (ii) retrospective comparison of 3,168 case samples from 2015 to 2020 analyzed by both gas chromatography-mass spectrometry (GC-MS) and Raman, (iii) assessment of spectral selectivity, and (iv) comparison of the instrument's on-screen results with combined partial least square regression (PLS-R) and discriminant analysis (PLS-DA) models. The limit of detection was dependent on sample composition and varied between 10 wt% and 40 wt% cocaine. Because the average cocaine content in street samples is well above this limit, a 97.5% true positive rate was observed in case samples. No cocaine false positives were reported, although 12.5% of the negative samples were initially reported as inconclusive by the built-in software. The spectral assessment showed high selectivity for Raman peaks at 1,712 (cocaine base) and 1,716 cm-1 (cocaine HCl). Combined PLS-R and PLS-DA models using these features confirmed and further improved instrument performance. This study scientifically assessed the performance of a commercial Raman spectrometer, providing useful insight on its applicability for both presumptive detection and legally valid evidence of cocaine presence for law enforcement.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Cocaína/análise , Aplicação da Lei , Análise Espectral Raman/instrumentação , Estudos de Viabilidade , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Limite de Detecção , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA